• Title/Summary/Keyword: 태양광 시스템

Search Result 1,894, Processing Time 0.028 seconds

A Study on PV Power Generation System Adding the Function of Shunt Active Filler Using DSP (DSP를 이용한 엑티브 필터 기능 추가형 태양광발전시스템의 운전특성에 관한 연구)

  • Seo, Hyo-Ryong;Park, Young-Gil;Kim, Jong-Hyun;Park, Min-Won;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.1169-1170
    • /
    • 2006
  • Grid connected PV(Photovoltic) generation systems are becoming and actual and general. The power output of PV system is directly affected by the weather conditions. And when AC power supply is needed, power conversion by an inverter and a MPPT control are necessary. The PV power generation system can be treated to a harmonics source for the power distribution system. So, the PV system combined the function of active filter system can be useful applied in power distribution system. AF(Active Filters) intended for harmonic solutions are expending their functions from harmonic compensation of nonlinear loads into harmonic isolation between utilities and consumer. With the test analysis of the proposed control strategy of PV-AF system, the outcome of the test shows the stability and effectiveness of the proposed PV-AF system. The various capability of AF has been proved in previous research and usage. In this paper, authors present a DSP controlled PV-AF system for power conditioning in three-phase industrial or commercial power systems and verify it through experimental results.

  • PDF

Characteristics analysis of Residential 3kW PV System (주택용 3kW 태양광발전시스템의 구성요소법 특성 분석)

  • Bian, W.J.;Piao, Z.G.;Lim, H.W.;Lee, K.Y.;Cho, G.B.;Baek, H.L.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.1181-1182
    • /
    • 2006
  • The solar power system comprises a solar battery that directly converts light energy to electrical energy with a photovoltaic effect and a power converter system, that is, inverter that converts direct current power, which is generated from solar battery to common alternating current. In this paper, database was constituted through remote monitoring supervision measurement for the long-time positive operation of 3kW solar power system installed within the solar energy positive research complex of Chosun University. As a result of analyzing the reduction of the efficiency of solar battery and inverter that are compositional components of PV system through an analysis on the acquired data, the PV output was proven over 65% of the total output when insolation intensity exceeded 600W/m2 in 2005, and the array conversion efficiency dropped much more than rating; meanwhile, insolation intensity dropped below 600W/m2. Therefore, it has been demonstrated that approximately 35% of the entire amount of PV output operated under the condition that the inverter efficiency rate dropped rapidly by 60 to 70%.

  • PDF

The unbalance compensation methode of PWM converter in a Utility interactive Photovoltaic Generation System (계통연계형 태양광발전 시스템의 불평형 보상기법)

  • Lee, J.H.;Shin, C.J.;Jeon, K.Y.;Bak, C.W.;Chun, J.Y.;Lee, S.C.;Oh, B.H.;Chung, C.B.;Han, K.H.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.1008-1009
    • /
    • 2006
  • There is an application which uses smoothing reacter connecting each of the phases in order to make the system smaller comparison with an application using the insulating transformer in the utility interactive photovoltaic generation system using the PWM converter. In this case, there might be the occurence of the unbalance of output voltage, by the difference of smoothing reactor, connected on each of the lines. Therefore this study proposes that the method which maintains the balance and compensates the unblance which occured by the different volume of the smoothing reactor connected on each of the lines.

  • PDF

A Study on the Energy Saving Capacity of Solar Power Generation System using Economic Evaluation (경제성 평가를 통한 태양광발전시스템 연계형 에너지저장장치 용량 선정에 관한 연구)

  • Lee, Yeo-Jin;Kim, Sung-Yul;Han, Se-Kyung
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.67 no.1
    • /
    • pp.21-26
    • /
    • 2018
  • Due to the international environmental regulations and changes in policies, the demand for generators using the renewable energy is increasing. However, renewable energy generators with intermittent output characteristics such as solar and wind power generators, need the buffer facilities such as ESS during system operations. However, because of low price competitiveness in energy storage system, it is difficult to operate the renewable energy generator with ESS. Therefore, the government has recently proposed a policy to compensate the REC for renewable energy system with ESS. For all this, since the initial cost of the ESS is high, it is the most important to calculate and operate the optimal capacity of the ESS through an economic analysis. In this paper, we proposed the method of calculation the optimal capacity of ESS and analyzed economic feasibility of renewable energy system using the ESS according to depreciation in ESS price.

Optimum MPPT Control Period for PV Panel based on Real Insolation Profile (실제 일사프로파일에 근거한 PV 패널의 최적 MPPT 제어주기)

  • Ryu, Danbi;Kim, Yong-Jung;Jeong, Woo-Yong;Kim, Hyosung
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.123-125
    • /
    • 2018
  • 태양광발전시스템은 낮은 효율의 PV 패널을 사용하여 최대의 전력을 생산하기 위해 PV 패널의 최대전력점에서 운전하는 MPPT(Maximum Power Point Tracking) 제어가 반드시 필요하다. 기존의 MPPT 알고리즘은 대부분 경사법에 기초하고 있으며 그 중 대표적인 방법이 P&O(Perturb and Observe) 알고리즘이다. P&O 알고리즘의 MPPT 성능을 좌우하는 두 가지 인수는 MPPT 제어주기와 변량전압의 크기이다. MPPT 제어기의 빠른 동특성과 극대화된 효율을 위한 최적의 MPPT 제어주기와 변량전압의 크기를 결정하기 위해서는 실제 날씨 환경에서 다양한 일사량 프로파일 패턴에 대한 MPPT 제어기의 성능분석이 필수적이다. 본 논문에서는 대한민국 중부지역의 전형적인 맑은 날씨와 흐린 날씨에서 실제 일사량을 측정하고, 취득한 일사량데이터를 기초로 저자가 개발한 다이오드 등가모델을 적용하여 시뮬레이션을 수행하였다. 이를 기반으로 MPPT 제어주기의 설정값에 따른 PV 패널의 전력생산량을 예측하여 MPPT 목표 효율을 극대화할 수 있는 최적의 MPPT 제어주기를 제시한다.

  • PDF

MPPT Control of Photovoltaic System using HBPI Controller (HBPI 제어기를 이용한 태양광발전 시스템의 MPPT 제어)

  • Ko, Jae Sub;Chung, Dong-Hwa
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.12
    • /
    • pp.1864-1871
    • /
    • 2012
  • This paper proposes the hybrid proportional integral(HBPI) controller for maximum power point tracking(MPPT) control of photovoltaic system. The output characteristics of the solar cell are a nonlinear and affected by a temperature, the solar radiation and influence of a shadow. The MPPT control is a very important technique in order to increase an output and efficiency of the photovoltaic system. The conventional constant voltage(CV), perturbation and observation(PO) and incremental conductance(IC) are the method which finding maximum power point(MPP) by the continued self-excitation vibration, and uses the fixed step size. If the fixed step size is a large, the tracking speed of maximum power point is faster, but the tracking accuracy in the steady state is decreased. On the contrary, when the fixed step size is a small, the tracking accuracy is increased and the tracking speed is slower. Therefore, in order to solve these problems, this paper proposes HBPI controller that is adjusted gain of conventional PI control using fuzzy control, and the maximum power point tracks using this controller. The validity of the controller proposed in this paper proves through the results of the comparisons.

Development of DC Leakage Current Sensor for Solar Power Generation System (태양광발전시스템용 직류 누설전류 센서 개발)

  • Kim, Hee-Sun;Hahn, Song-Yop;Han, Hoo-Sek
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.6
    • /
    • pp.828-833
    • /
    • 2014
  • Grid connected transformerless solar power generation system is frequently used with the benefits of cost and efficiency. However, significant DC leakage current can flow from the DC line into the ground with dielectric breakdown in the transformerless solar power generation system. The leakage current occurred in the DC line causes accidents such as fire and electric shock on human. To resolve this problem, high sensitivity DC leakage current sensor is needed. But recently the studies on safety of DC line are not performed. In this paper, a high sensitivity DC leakage current sensor that can detect DC leakage current in solar power generation system, is proposed. Based on the studies, DC leakage current sensor is fabricated and characteristic tests are carried out. Finally, the accuracy of sensor performance is verified by leakage current experiments in solar power generation system.

Maximum Efficiency Point Tracking Control Algorithm for Improving Electric Power Transmission Efficiency between Photovoltaic Power Generating system and the Grid (태양광발전시스템과 계통간의 전력 전송 효율 개선을 위한 최대효율점 추적 제어 알고리즘)

  • Kwon, Cheol-Soon;Kim, Kwang Soo;Do, Tae Young;Park, Sung-Jun;Kang, Feel-Soon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.3
    • /
    • pp.342-348
    • /
    • 2013
  • It proposes an efficient control algorithm to increase electric power transmission efficiency between photovoltaic power generating system and the grid. The main controller finds a maximum efficiency condition by considering the quantity of power generated from PV arrays, the number of inverters, and efficiency of PV inverter. According to the condition, a relay board arranges a point of contract of PV arrays. By the disposition of PV arrays, it assigns the optimized power on each PV inverter. Operational principle of the proposed maximum efficiency point tracking algorithm is given in detail. To verify the validity of the proposed approach, computer-aided simulation and experiment carried out.

DC-link Voltage Control of Grid Connected PV System using Quasi Z-Source Inverter (QZSI를 이용한 계통연계형 태양광발전 시스템의 직류단 전압제어)

  • Park, Jong-Hyoung;Kim, Heung-Geun;Nho, Eui-Cheol;Chun, Tae-Won;Cha, Honnyong
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.3
    • /
    • pp.201-210
    • /
    • 2014
  • In this paper, dc-link voltage control of a grid-connected QZSI is presented. Since the input current of the ZSI is discontinuous, a capacity with relatively large capacitance should be connected to the output of the PV array in order to reduce the current ripple. Due to the presence of the impedance network inductor in series with the PV array, the QZSI can achieve continuous input current flow. Several dc-link voltage control methods are compared and the method for power quality improvement is also presented. The performance of the proposed method is verified through both simulation and experimental results.

A Utility Interactive Photovoltaic Generation System Using PWM Converter (PWM 컨버터를 이용한 계통연계형 태양광발전 시스템)

  • Chung, J.H.;Jho, J.M.;Jeon, K.Y.;Lee, S.H.;Oh, B.H.;Kim, S.N.;Kim, Y.J.;Han, K.H.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1253-1255
    • /
    • 2003
  • Since the residential load is an AC load and the output of solar cell is a DC Power, the photovoltaic system needs the DC/AC converter to utilize solar cell. In case of driving to interact with utility line, in order to operate at unity power factor, converter must provide the sinusoidal wave current and voltage with same phase of utility line. Since output of solar cell is greatly fluctuated by insolation. it is necessary that the operation of solar cell output in the range of the vicinity of maximum power point. In this paper DC/AC converter is three phase PWM converter with smoothing reactor. And then, feedforward control used to obtain a superior characteristic for current control and digital PLL circuit used to detect the phase of utility line.

  • PDF