탄화수소계 냉매의 증발 열전달 및 압력강하 특성 (Characteristics on Evaporating Heat Transfer and Pressure Drop of HCs Refrigerants)

  • 이광배;이호생;김재돌;윤정인
    • 설비공학논문집
    • /
    • 제17권7호
    • /
    • pp.681-687
    • /
    • 2005
  • Experimental results for heat transfer characteristic and pressure gradients of HCs refrigerants R-290, R-600a, R-1270 and HCFC refrigerant R-22 during evaporating inside horizontal double pipe heat exchangers are presented. The test sections which has one tube diameter of 12.70 m with 0.86 mm wall thickness, another tube diameter of 9.52 mm with 0.76 mm wall thickness are used for this investigation. The local evaporating heat transfer coefficients of hydrocarbon refrigerants were higher than that of R-22. The average evaporating heat transfer coefficient increased with the increase of the mass flux. It showed the higher values in hydrocarbon refrigerants than R-22. Hydrocarbon refrigerants have higher pressure drop than R-22 in 12.7 mm and 9.52 mm. This results form the investigation can be used in the design of heat transfer exchangers using hydrocarbons as the refrigerant for the air- conditioning systems.

탄화수소계 냉매의 응축 열전달 및 압력강하 특성 (Characteristics of Condensing Heat Transfer and Pressure Drop of Hydrocarbon Refrigerants)

  • 이호생;성광훈;;윤정인
    • 설비공학논문집
    • /
    • 제18권12호
    • /
    • pp.977-983
    • /
    • 2006
  • Experimental results for heat transfer characteristic and pressure gradient of hydrocarbon refrigerants (R-290, R-600a, R-1270) and HCFC refrigerant (R-22) during condensation inside horizontal double pipe heat exchangers are presented. The test sections which have one tube diameter of 12.70 mm with 0.89 mm, 9.52 mm with 0.76 mm, 6.35 mm with 0.13 mm wall thickness are used for this investigation, respectively. The local condensing heat transfer coefficients of hydrocarbon refrigerants were higher than those of R-22. The average condensing heat transfer coefficient increased with the increase of the mass flux. It showed the higher values in hydrocarbon refrigerants than R-22. Hydrocarbon refrigerants have higher pressure drop than R-22 in 10.92 mm, 8 mm and 6.1 mm inner diameters. These results from the investigation can be used in the design of heat transfer exchangers using hydrocarbons as the refrigerant for the air-conditioning systems.

$CO_2$ 냉매 이응 냉동사이클

  • 김용찬;김민수
    • 대한설비공학회지:설비저널
    • /
    • 제31권7호
    • /
    • pp.4-9
    • /
    • 2002
  • 환경문제에 대한 관심이 높아짐에 따라, 냉동공조 산업에서 다양하게 이용되는 냉매에 대하여도 많운 시각이 집중되고 있다. 특히, 몬트리얼 의정서와 교토의정서에 의한 지구온난화 물질에 대한 규제로 CFCs와 HCFCs 냉매를 사용하지 못하게 펌에 따라 냉동공조업계에서는 열역학적 물성치가 우수하고 환경친화적인 대체냉매의 개발에 관한 연구를 활발히 진행하고 있다. 이러한 문제의 근본적인 해결책은 자연상태로 존재하는 자연냉매를 이용하는 것이디. 이산화탄소, 암모니아, 탄화수소계열, 물, 공기 등이 대표적으로 거론되고 있는 자연냉매이다. 이 중에서 도 이산화탄소는 인체에 무해하며, 독성이 없고, 화 학적으로 안정하며,기존의 냉동기 재료를 그대로 사용할 수 있는 장점이 있다. 또한 열역학적 성질 및 전달물성이 우수하고, 냉통기에 적용할 때 성능이 개선될 가능성이 많다는 점도 매우 고무적이다. 본 고에서는 최근 가장 주목을 받고 있는 이산화탄소를 이용한 냉동사이클의 특성과 성능향상 방안에 대하여 기존 연구결과를 정리하여 설명하고자 한다.

  • PDF

탄화수소 및 불화탄화수소 혼합냉매의 기상-액상 평형에 관한 실험적 연구 (An Experimental Study on Vapor-Liquid Equilibria of HFC and HC Refrigerant Mixtures)

  • 강병복;김민수;김영일
    • 설비공학논문집
    • /
    • 제12권11호
    • /
    • pp.1031-1037
    • /
    • 2000
  • Isothermal vapor-liquid equilibrium(VLE) data have been obtained for the systems of propane(R290)+1,1,1,2-tetrafluoroethane(R134a) and 1,1,1,2-tetrafluoroethane(R134a)+isobutane(R60A) in the temperature range of 253.15 to 323.15K. Experiments were performed in a circulation type apparatus by injecting vapor through liquid pool using a magnetic pump. Both systems form azeotropes in the temperature range of this study. The experimental results were estimated with the Peng-Robinson equation of state. When the temperature-dependent binary interaction parameter was used in the Peng-Robinson equation of state, the absolute average deviation of the measured bubble point pressures from the values correlated by the Peng-Robinson equation was 0.65% and 0.78% for R290+R134a and R134a+600a, respectively. Azeotropic compositions for both systems were presented.

  • PDF

수평관내 HC계 냉매의 증발 압력강하 특성 (Characteristics on Evaporating Pressure Drop of HCs Refrigerants inside a horizontal tube)

  • 최준혁;이호생;김재돌;윤정인
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2006년도 전기학술대회논문집
    • /
    • pp.63-64
    • /
    • 2006
  • Chracteristics on evaporating pressure drop of HCs refrigerants inside a horizontal tube were studied experimentally. Experimental results were presented for pressure drops of hydrocarbon refrigerants R-290, R-600a, R-1270 and HCFC refrigerant R-22 inside a horizontal double pipe heat exchanger. Three tubes with a tube diameter of 12.70mm, 9.52mm and 6.35mm were used for this study. Hydrocarbon refrigerants showed higher evaporating pressure drop than that of R-22 in all tubes. The highest pressure drop was founded in R-600a. The highest evaporating perssure drop of all refrigerants was shown in a tube diameter of 6.35mm with same mass flux. The results can be used as the basic data for the design of heat exchanger using hydrocarbon refrigerants as an alternatives.

  • PDF

탄화수소계 냉매의 응축 열전달 및 압력강하 특성 (Characteristics of Condensing Heat Transfer and Pressure Drop of HCs Refrigerants)

  • 이호생;이광배;문춘근;김재돌;윤정인
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 전기학술대회논문집
    • /
    • pp.1143-1148
    • /
    • 2005
  • Experimental results for heat transfer characteristic and pressure gradient of HCs refrigerants R-290, R-600a, R-1270 and HCFC refrigerant R-22 during condensing inside horizontal double pipe heat exchangers are presented. The test sections which have one tube diameter of 12.70 mm with 0.86 mm wall thickness, another tube diameter of 9.52 mm with 0.76 mm wall thickness are used for this investigation. The local condensing heat transfer coefficients of hydrocarbon refrigerants were higher than those of R-22. The average condensing heat transfer coefficient increased with the increase of the mass flux. It showed the higher values in hydrocarbon refrigerants than R-22. Hydrocarbon refrigerants have higher pressure drop than those of R-22 in 12.7 mm and 9.52 mm. This results from the investigation can be used in the design of heat transfer exchangers using hydrocarbons as the refrigerant for the air-conditioning systems.

  • PDF

탄화수소계 냉매의 풀비등 열전달 상관식 개발 (Development of Pool Boiling Heat Transfer Correlation for Hydrocarbon Refrigerants)

  • 박기정;백인철;정동수
    • 설비공학논문집
    • /
    • 제18권3호
    • /
    • pp.247-253
    • /
    • 2006
  • In this work, pool boiling heat transfer coefficients (HTCs) of hydrocarbon refrigerants are measured from a horizontal smooth tube of 19.0 mm outside diameter. Tested pure refrigerants are Propylene, Propane, Isobutane, Butane and Dimethylether (DME). The pool temperature was maintained at saturation temperature of $7^{\circ}C$ and heat flux was varied from $10kW/m^2$ to $80kW/m^2$ with an interval of $10kW/m^2$. Wall temperatures were measured directly by thermocouple hole of 0.5 mm out-diameter, 152 mm long and inserting ungrounded sheathed thermocouples from the side of the tube. Tested results show that HTCs of Propane, Propylene are 2.5%, 10.4% higher than those of R22 while those of Butane and Isobutane are 55.2%, 44.3% lower than those of R22 respectively. For pure refrigerants, new correlation can be applied to all of CFCs, HCFCS, HFCs, as well as hydrocarbons was developed. The mean deviation was 4.6%.

$CO_2$ 냉매의 증발열전달 특성

  • 정시영
    • 대한설비공학회지:설비저널
    • /
    • 제31권7호
    • /
    • pp.15-23
    • /
    • 2002
  • 환경친화적인 냉매를 탐색하는 과정에서 자연냉매 $CO_2$는 1990년대 초에 많은 사람들의 관심을 다시 끌게 되었고, 그 이후 구미 선진국 위주로 많은 연구가 이루어지고 있다. 특히 $CO_2$는 탄화수소계 냉매가 안전상의 이유로 사용되기 어려운 차량용 냉방 시스템과 온수제조용 열펌프 시스템에 대하여 많은 연구가 이루어져 왔으며 최근에는 가정용 냉난방 시스템에 대한 연구도 진행되고 있다. $CO_2$를 냉매로 사용하는 냉동 시스템에 있어서 증발기는 시스템의 중요한 구성 요소이므로 제품 개발을 위해서는 증발기에서의 열전달 및 압력손실 특성에 대한 연구가 선행되어야 한다. $CO_2$의 증발 열전달에 있어서 작동매채인 $CO_2$의 비체적, 비열, 점성계수, 표면장력 등의 물성치가 크게 변화하므로 기존에 널리 사용되던 냉매의 중발열전달과는 상당히 다른 결과가 나타난다. 예를 들면 기존의 냉매에서는 건도가 증가함에 따라 열전달계수가 증가하는 것으로 알려져 있으나 $CO_2$의 경우에는 오히려 열전달계수가 감소하는 것으로 보고되고 있다. 이처럼 $CO_2$는 증발열전달 과정에서 기존 냉매의 경향으로부터 예측하기 힘든 결과가 나타나므로 다양한 형상의 증발기에 대하여 실험적으로 압력손실과 열전달계수를 구하는 연구는 성공적인 $CO_2$ 냉동 시스템의 개발을 위하여 필수 불가결하다. 본고에서는 $CO_2$ 냉동 시스템의 개발에 도움이 될 수 있도록 지금까지 국내외에서 수행된 $CO_2$ 증발 열전달에 관한 문헌조사를 통하여 연구결과들을 비교, 분석하고 향후의 연구 방향을 제시하고자 한다.