• 제목/요약/키워드: 탁도 제거율

Search Result 92, Processing Time 0.023 seconds

Study on Removal of Artificial Radionuclide (I-131) in Water (물속의 인공방사성핵종(I-131) 제거율 연구)

  • Jeong, Gwanjo;Lee, Kyungwoo;Kim, Bogsoon;Lee, Suwon;Lee, Jonggyu;Koo, Ami
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.11
    • /
    • pp.747-752
    • /
    • 2014
  • Iodine-131, an artificial radionuclide, mostly exists as iodide ion ($^{131}I^-$) and iodate ion ($^{131}IO_3{^-}$) in the water, and When a short time contacted, it could not be removed by poly aluminum chloride (PACl) and powdered activated carbon (PAC). Although the removal rate of iodine-131 was not related with turbidity of raw water, it showed linear relationship with contact time with PAC. With the mixture of PACl (24 mg/L or more) and PAC (40 mg/L or more), about 40% of iodine-131 could be removed. Iodine-131 could be removed little by sand filtration, but approximately 100% by granular activated carbon (GAC), both virgin-GAC and spent-GAC. Microfiltration process could remove little iodine-131 while reverse osmosis process could remove about 92% of iodine-131.

유연성 섬유사 필터 모듈을 이용한 육상수조식 양식장 수처리

  • 최광수;한기백;이해군;김지원
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2003.05a
    • /
    • pp.81-82
    • /
    • 2003
  • 육상수조식 양식장 수처리를 위한 순환여과 시스템으로서의 유연성 섬유사 필터 모듈의 적용성을 평가하기 위하여, 여과기의 운전주기에 따른 처리성능의 변화 추이 및 넙치사육조의 급이주기에 따른 여과성능의 변화를 검토한 결과, 유기물 농도의 경우 20~70%의 제거육을 보였으며, 탁도는 평균 50% 이상의 제거율을 보여주었다.

  • PDF

Removal of Algae by Natural Coagulants of Soil Origin (천연 무기응집제를 이용한 조류 제거)

  • Kim, Seog-Ku;Kim, Dong-Kwan;Kang, Sungwon;Ahn, Jaehwan;Kim, Il-Ho;Yun, SangLeen;Lee, Sanghyup;Lee, Wontae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.12
    • /
    • pp.883-888
    • /
    • 2013
  • Coagulation and sedimentation tests were conducted with clay and three different coagulants of soil origin (AC-A, AC-B, AC-C) to determine optimal coagulant types and doses to remove algae in stagnant water bodies such as reservoirs. Raw water had an algal density of 2,950 cells/mL and was dominated by Cyanobacteria. Removal rates of algal density by clay (50 mg/L) were 49% and 85% after 10 and 30 minutes sedimentation, respectively. Other natural coagulants achieved 80-90% removal in 10 minutes and 89-94% removal in 30 minutes of sedimentation after adding 20 mg/L each. AC-A was the optimal coagulant from this study considering algal removal rates and other water quality parameters such as turbidity and pH. For the same removal rates of algae, raw waters with higher algal densities required higher coagulant doses although no strong corelation was observed. The coagulants of soil origin did not impact orgnic contents and pH of raw water, but remove phosphate up to 70%.

Advanced Water Treatment of High Turbidity Source by Hybrid Process of Ceramic Microfiltration and Activated Carbon Adsorption: Effect of GAC Packing Fraction (세라믹 정밀여과 및 활성탄 흡착 혼성공정에 의한 고탁도 원수의 고도정수처리: 입상 활성탄 충전율에 의한 영향)

  • Park, Jin-Yong;Lee, Hyuk-Chan
    • Membrane Journal
    • /
    • v.18 no.3
    • /
    • pp.191-197
    • /
    • 2008
  • In this study, we used hybrid module that was composed of packing granular activated carbon (GAC) between module inside and outside of ceramic microfiltration membrane for advanced drinking water treatment. Instead of natural organic matters (NOM) and fine inorganic particles in natural water source, synthetic water was prepared with humic acid and kaolin. Packing fraction of GAC was changed from 0 to 24.05% to see effect of packing fraction. As a result, changing curves of resistance of membrane fouling ($R_f$) and permeate flux (J) during 3 h operation were almost overlapped independent of packing fraction of GAC. Treatment efficiencies of turbidity were very high above 99.46% at all packing fractions of GAC. And treatment efficiency of NOM, which was measured by $UV_{254}$ absorbance, was the highest value of 99.43% at packing fraction of 24.05%. Then, we operated the hybrid process during 13 h at packing fraction of 24.05%. As a result, J was rapidly dropped according to increase of membrane fouling within initial 1 h of operation, and almost constant after 3 h. And treatment efficiencies of turbidity and NOM were stable and high values of 99.52% and 96.63%, respectively.

무세미 조제시스템 개발

  • 최희석;박회만;정성근;홍성기;조광환;금동혁
    • Proceedings of the Korean Society of Postharvest Science and Technology of Agricultural Products Conference
    • /
    • 2003.10a
    • /
    • pp.174-175
    • /
    • 2003
  • 현재 유통되고 있는 일반백미의 경우 소비자가 밥을 짓기 위해서는 쌀을 씻어야하는 번거로움 뿐만아니라 쌀 중량의 약 15배의 물이 소요되고, 또한 이때 발생된 쌀뜨물이 수질오염의 원인이 되기 때문에 무세미가공 및 보급 필요성이 점차 높아지고 있다. 무세미 가공분야의 선진국인 일본의 경우 ‘92년부터 습식 무세미조제기가 실용화되기 시작, 현재 사다께 등 6개사에서 기계장치를 생산보급 하고 있으며, 무세미의 유통도 일반화되어가고 있는 추세이다. 국내의 경우 무세미조제기는 근래에서야 습식 무세미 조제설비가 국산화되어 보급초기 단계 있으며, 무세미의 안정적 가공 및 보급을 위해서는 앞으로 많은 연구가 이루어져야 할 것으로 생각된다. 특히 습식의 경우 쌀이 물에 접촉하는 시간이 길 경우 품질저하의 우려가 크고, 쌀중량의 1.4배에 해당하는 물이 가공과정에 필요하기 때문에 물사용량을 억제할수 있는 가공기술의 개발 필요성이 커지고 있다. 따라서 본 연구에서는 물사용량을 최소화 할 수 있는 무세미 조제시스템을 개발하고자 하였으며, 주요결과를 요약하면 다음과 같다. 시작기는 연마 및 공기세척부, 정전기 세척부, 미세가수세척부로 구성하여 쌀이 단계적으로 세척될 수 있도록 제작되었다. 성능시험 결과, 각 세척공정별 세척수의 탁도 감소효과는 연마 및 공기크리닝부에서 22.67ppm, 정전기 크리닝부에서 8.33ppm, 미세가수세척부에서 17.34 ppm이 감소되는 것으로 나타났다. 특히 정전기세척부의 탁도감소 효과는 다른 두공정에 비해 작지만 제거가 쉽지 않은 미세한 쌀겨들을 제거하여 탁도를 개선을 시켰기 때문에 미세가수세척장치에서 가수량을 적게 사용하는데 기여한 것으로 판단된다. 가공시 적정 탁도를 확보할 수 있는 가수량은 430cc/kg로 기존의 습식에 비해 약 69%정도 세척수 절감효과가 있었다. 이때 미세가수세척부의 원통스크린 회전수는 108, 205rpm범위가 적정한 것으로 나타났다. 쌀의 품위는 탁도가 가공전 97.33ppm(일반백미)에서 가공후 최대 48.00ppm으로 낮아졌으며, 백도도 가공전 36.80에서 42.80으로 향상되어 씻지 않고도 밥을 지을수 있는 무세미 가공이 가능하였다. 이밖에 쇄립률은 가공전 5.30%에서 7.37%로 다소 증가하는 것으로 나타났고, 함수율은 가공전 15.60%에서 15.80%로 약 0.2%가 증가하였으나 기존의 연구결과에 비춰볼 때 문제가 되지 않을 것으로 여겨진다.

  • PDF

Comparison of Electrocoagulation and Chemical Coagulation in Removal on Water Treatment (정수처리에서 전기응집과 화학응집의 처리효율 비교)

  • Han, Moo-Young;Song, Jae-Min;Park, Sang-Cheol
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.5
    • /
    • pp.689-695
    • /
    • 2004
  • Electrocoagulation has been suggested as a promising alternative to conventional coagulation. The process is characterized by reduced sludge production, no requirement for chemical use, and ease of operation. However, this coagulation has scarcely been studied in water purifying process. This study was performed several batch experiments to compare turbidity removal between electrocoagulation and chemical coagulation. In addition, characteristics of floe were evaluated with zeta potential and particle size distributions. Electrocoagulation showed a relatively higher removal of turbidity (approximately 5%) with the same aluminum amount than conventional chemical coagulation. In addition, turbidity removal by electrocoagulation was less sensitive to pH and was greater for more extensive pH range than chemical coagulation. The results of zeta potential and floc size distributions illustrated that electrocoagulation provided the preferable conditions for coagulation such as zeta potential close to zero millivolt and increased portions of particles in the range of 40 and $100{\mu}m$.

Application of the Peel Extracts of Astringent Persimmon Fruits for Wastewater Treatment (폐기 떫은감 껍질 추출물의 생활하수 처리에의 적용)

  • Cho, Young-Je;Chun, Sung-Sook;An, Bong-Jeun
    • Applied Biological Chemistry
    • /
    • v.49 no.1
    • /
    • pp.30-34
    • /
    • 2006
  • The wastewater was quickly and fastly cleared by the peel extracts of astringent persimmon fruits. The degree of clearness increased with increasing concentrations (400-600 mg/l) of the peel extracts of astringent persimmon fruits. The removal rates of T-P and CODcr in wastewater with lime and the peel extracts of astringent persimmon fruits were lower than ferric chloride and aluminium sulfate at 100-200 mg/l concentration but higher at above 300 mg/l concentration. The removal rate of T-P increased with increasing concentration of the peel extracts of astringent persimmon fruits.

Water Treatment of Seawater Recirculating Aquaculture System by Using Three Phase Fluidized Bed Reactor (삼상 유동층 반응조를 이용한 해수 순환 여과 시설의 수처리)

  • Lee, Byung-Hun;Choi, Hyeok;Ryu, Jong-Soo
    • Journal of Aquaculture
    • /
    • v.13 no.2
    • /
    • pp.137-145
    • /
    • 2000
  • Capacity of water treatment of the three phase fluidized bed reactor as a biofilter in the seawater recirculating system was evaluated. The water treatment system consists of fluidized bed reactor for ammonia removal, cartridge filter for solid removal and ozone contactor for disinfection. Mean concentration of water quality parameters: COD, TAN, $NO_2$-N, $NO_3$-N, SS and alkalinity were 9.0, 0.22, 0.05, 20.0, 9.5 and 70.0 mg/l, respectively; the relevant values were 7.6 for pH and 3.64 NTU for turbidity. These indicate the maintenance of good water quality by the treatment system. The influent TAN loading rate in to the fluidized bed reactor ranged from 4.3 to 32.9 g/$m^3$/day, and averaged to 20 g/$m^3$/day. TAN removal efficiency of each phase of the fluidized bed reactor was 47-60%, indicating the effective ammonia removal. During operation the effluent of fluidized bed reactors also maintained the unionized ammonia nitrogen level below 0.002 mg/l.

  • PDF

비정질/결정질 실리콘 이종접합 태양전지 특성에 있어 ZnO 투명전도산화막의 영향

  • Gang, Min-Gu;Ok, Yeong-U;Tak, Seong-Ju;Lee, Jeong-Cheol;Yun, Gyeong-Hun;Kim, Dong-Hwan
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2007.06a
    • /
    • pp.211-214
    • /
    • 2007
  • 차세대 태양전지로 많은 연구가 이루어지고 있는 비정질/결정질 실리콘 태양전지 제작 과정 중에 투명 전극으로 사용되는 ZnO의 증착에 따른 태양전지 특성변화에 대한 연구를 시행하였다. 벌크 실리콘 웨이퍼 위에 비정질 실리콘을 증착한 후 공기 중에 노출된 경우와 노출 이후 산화막을 제거한 후 투명 전극으로 ZnO을 증착했을 경우 태양전지의 특성에 큰 영향을 미침이 확인되었다. 산화막 제거하지 않을 경우 개방전압 및 충진율의 저하를 가져 왔으며, 산화막이 제거된 경우 개방전압과 충진율의 증가로 인한 태양전지 특성이 향상되었음을 보여주었다.

  • PDF

Performance Evaluation for Water Quality Enhancement (수질향상을 위한 정수장 성능평가)

  • Simpson Stephen-L;Singer Charlie
    • 수도
    • /
    • v.24 no.4 s.85
    • /
    • pp.30-38
    • /
    • 1997
  • County는 비용과 부지소요는 최소화하면서도 증가하는 지역적 물수요에 부합되는 높은 유량에서 정수장의 성능을 최대화해야하는 필요성에 직면해있다. 개선사항을 찾아내기 위하여 시설물에 대한 상세한 성능평가가 행해졌다. 성능평가는 여과와 소독공정이 운전방식의 조정과 함께 추가시설의 건설에 의하여 개선될 수 있음을 나타내었다. Pilot test는 실험된 여러 가지 대안들 중에서 혼화, 응집, 이중 여과방식이 입자의 제거와 정수 수질에 가장 좋은 것임을 보여주었다. 소독에 대한 분석 결과는 소독방법을 교정하고 추가적인 염소접촉시간을 주는 것이 소독의 안전성을 확보함과 동시에 정수의 소독부산물 농도를 최소한으로 하고 강화되는 규제치와 부합할 수 있는 최선의 방법이 될 것이라는 것을 보이고 있다. Pilot test는 저수두 자동역세척여과지가 1차여과지(roughing filter)로서 효과적이라는 것을 보여주었다. 실험결과는 이중여과가 최종유출수의 탁도를 평균 0.1NTU이하로 감소시키며 입자의 제거율을 3 log로 증가시킴을 나타내고 있다. 정수공정 전반에서의 입자의 제거는 여러 개의 공정의 개별적 성과의 합이 아니므로 시설물들을 건설하기 전에 정수장 전체적으로 예상되는 개선정도를 수량화하기 위하여 Pilot 실험이 필요하였다. Pilot test중에 탁도보다는 입자측정이 유량, 응집제의 주입량, 및 여타 운전조건의 변화에 훨씬 민감함을 보여주었다. 이러한 점이 입자측정이 특히 저탁도 원수에서 처리공정의 성능을 나타내 주는 적절한 추가적 수질인자라는 결론을 보강하여 주었다. 물수요에 부합하기 위하여 Freedom District 정수장을 성공적으로 개선하는 데는 원수의 수질, 단위공정의 성능, 활용가능한 수리학적 수두, 현시설의 배치, 운전양태 등과 같은 기술적 사항에 대한 고려가 필요하였다. 비록 모든 사항들이 각각 일정정도의 영향을 가지고 있으나, 상기의 모든 것들이 수질에 영향을 미쳤으며 수질의 성공적인 개선은 정수장 운전의 모든 부분을 파악할 수 있는 상세한 성능평가를 통하여 가장 잘 달성될 수 있다.

  • PDF