• 제목/요약/키워드: 크롬 도금

검색결과 141건 처리시간 0.024초

도금공정 크롬시료 분석을 위한 Microwave Oven Digestion/Atomic Absorption Spectrophotometry 방법의 정확도 및 정밀도 평가 (Accuracy and Precision of Microwave Oven Digestion/Atomic Absorption Spectrophotometry for Analyzing Airborne Chromium Collected on MCE Filter in Plating Operation)

  • 이병규;이지태;신용철
    • 한국산업보건학회지
    • /
    • 제11권1호
    • /
    • pp.48-55
    • /
    • 2001
  • The purpose of this study was to evaluate the analytical accuracy and precision of microwave oven digestion/atomi absorption spectrophotometry (AAS) for analyzing airborne chromium collected on mixed cellulose ester membrane (M filter from the work environment, and to compare the accuracy and the precision with those of the National Institute for Occupational Safety and Health (NIOSH) Method #7024 hot plate digestion/AAS method. For this study, field air sample pairs were collected from a electroplating process, and spiked samples in a laboratory were prepared and using these samples. Two digestion methods were comp; and evaluated in terms of recovery rate and bias as indices of accuracy and coefficient of variation as a index of precision. The results and conclusions are as follows. In spiked samples, the accuracies (% mean recoveries) of hot plate/AAS and microwave oven/AAS method were 97.19%, 97.1%, respectively, and the precisions (pooled respectively, and the precisions (pooled coefficient of variance, $CV_{pooled}$) 6.93% and 3.88%, respectively. The biases of hot plate ani microwave oven methods were 4.56 - 14.7% and 2.22 - 7.42% respectively. There was no statistically significant difference between hot plate and microwave oven methods recovery rates of spiked samples (p>0,05). Also, no statistically significant difference was shown among the concentrations of air samples determined by two method (p>0.05). In conclusion, microwave oven/AAS method h excellent accuracy and precision, and advantages such as time-saving and simple procedure in comparison with the classical NIOSH method. Therefore, this method can be use widely to analyze airborne chromium collected on MCE filter from the work environments.

  • PDF

도금공정 공기중 6가 크롬 시료채취여과지 비교에 관한 연구 (Comparison of Sampling Filters for Airborne Hexavalent Chromium in Plating Operation)

  • 이병규;신용철
    • 한국환경보건학회지
    • /
    • 제29권2호
    • /
    • pp.69-76
    • /
    • 2003
  • Hexavalent chromium may reduce on polyvinyl chloride (PVC) filter during sampling and storage of sample. Recently, new or modified filters for preventing Cr(VI) from the reduction has been introduced. Thus, this study was performed to compare the reduction behaviors of Cr(VI) on several sampling filters and to find the most appropriate filter for airborne Cr(VI) sampling in plating operation. The results were as follows. 1. There were statistically significant differences among PVC, polytetrafluoroethylene (PTFE). glass fiber (GF) and polyvinylidene fluoride (PVDF) filters in recovery rates of spiked Cr(VI) samples by storage time(p<0.05). There was no significant difference between PVC and PTFE filters(p>0.05). The PVC and PTFE filters showed higher recoveries than GF and PVDF filters(p<0.05). 2. The quartz fiber(QF) filter treated with an alkali solution(2% NaOH/3% Na$_2$CO$_3$, 1% NaOH) showed a significantly higher recovery of Cr(VI) by storage time than other filters(GF and QF filter)(p<0.05). There was no difference in recovery of Cr(VI) between alkali-treated and untreated GF it filters(p>0.05). But the QF filters treated with two alkali solution showed a significantly higher recovery than the untreated QF filter(p<0.05). There was no significant difference in recovery of Cr(VI) between QF filters treated with 1% NaOH and 2% NaOH/3% Na$_2$CO$_3$(p>0.05). In conclusion, treatment of QF fillers with alkali solution was most effective in protecting from the reduction of Cr(VI).

도금업 근로자의 혈청과 공기중 크롬 및 니켈 농도 (Chromium and nickel concentrations in air and in serum of workers in chromium and nickel electroplating plants)

  • 최호춘;김해정;정호근
    • 한국산업보건학회지
    • /
    • 제1권2호
    • /
    • pp.117-127
    • /
    • 1991
  • The exposure level of chromium and nickel for chrome and nickel plating workers were evaluated. Chromium and nickel concentrations in serum from 82 exposed workers and 66 controls, who were not exposed occupationally to metals, were analyzed by flameless atomic absorption spectrophotometry. The results were as follows : 1. The recovery percent of chromium and nickel concentrations in personal air samples were 95-108.2%, 88.0-107.7%, precisions (C.V., %) were 2.7-3.1%, 2.1-4.4%. respectively. 2. The recovery percent of chromium and nickel concentrations in serum were 93.6-106.4%, 91.3-107.9% and precisions (C.V. %) were 1.1-7.6%, 2.4-5.4% respectively. 3. The exposure level of chromium and nickel concentrations in the place of preparation process were $2.0{\pm}2.00{\mu}g/m^3$, chromplating were $35.7{\pm}53.07{\mu}g/m^3$, $2.8{\pm}3.42{\mu}g/m^3$, nickelplating were $4.6.0{\pm}5.8{\mu}g/m^3$, $18.62{\pm}4.41{\mu}g/m^3$, and covering were $2.9{\pm}2.02{\mu}g/m^3$, $1.1{\pm}0.47{\mu}g/m^3$ respectively. There were significant difference of concentrations for chromium and nickel in workplaces by groups statistically. 4. Chromium concentrations in serum of exposed group and control were $0.68{\pm}0.399{\mu}g/l$, $1.41{\pm}0.748{\mu}g/l$, respectively. There were significant difference of concentrations for chromium and nickel in serum by groups statistically. 5. Chromium and nickel concentrations in serum of exposed group were not significant by workplaces.

  • PDF

중소기업 도금공정에서의 6가 크롬 폭로에 관한 연구 (A Study on Worker Exposure to Hexavalent Chromium in Plating 0peration)

  • 정희경;백남원
    • 한국산업보건학회지
    • /
    • 제3권2호
    • /
    • pp.152-165
    • /
    • 1993
  • This study was performed at eleven small-sized plating factories located in Seoul, Incheon, Ansan, and Taejeon from July 21 to October 6, 1992. The major objectives of this study were to evaluate worker exposure to hexavalent chromium and local exhaust ventilation (L.E.V.) systems at the chromium plating operations. The most suitable L.E.V. systems for chromium plating tanks were designed as examples for recommendation to the industry. The results are summarized as follows. The range of chromium plating operations investigated included decorative, hard, and black chromium plating on several kinds of parts. Most of plating tanks were not equipped with proper control methods against emission of hexavalent chromium mists and workers were not wearing appropriate personal protectives. The ariborne hexavalent chromium concentrations showed an approximate lognormal distribution. The geometric means of both personal and area samples were within the Korean and ACGIH standards, $50{\mu}g/m^3$. However, in comparison with the NIOSH criterion, $1{\mu}g/m^3$, the geometric means of personal samples at two factories and the geometric means of area samples at two factories exceeded it. The geometric means of personal and area samples of high exposure groups (above the NIOSH criterion) were 7 and 27 times higher than those of low exposure groups (below the NIOSH criterion), respectively. The L.E.V. systems of high exposure groups were improperly designed, and the factory with the highest exposure level had no L.E.V. systems at all on chemical etching process. Whereas at factories of low exposure groups, mist control methods such as mist suppressants, tank cover, and/or auxillary L.E.V. systems were added to L.E.V systems. The evaluation of L.E.V. systems showed that there was no chromium plating operation satisfying the ACGIH criteria for capture velocity, slot velocity, and exhaust rate simultaneously. To increase performance of L.E.V. systems, it must be designed to minimize the impact of boundary layer separation. Push-pull ventilation hood and downward plenum ventilation hood were suggested for the Korean industry.

  • PDF

철소지 위에 형성된 니켈 및 니켈-크롬 도금층의 염수분무, 캐스, 전해부식시험법을 이용한 내식성평가 (Evaluation of the Corrosion Resistance of Plated Ni and Ni-Cr Layers on Fe Substrate by Using Salt Spray, CASS and EC Tests)

  • 신재호;이동훈;이재봉;신성호
    • 한국표면공학회지
    • /
    • 제36권4호
    • /
    • pp.307-316
    • /
    • 2003
  • Salt spray, CASS(copper accelerated acetic salt spray) and EC(electrolytic corrosion) tests were performed in order to evaluate the corrosion resistance of plated Ni and Ni-Cr layers on Fe substrate. Compared with the conventional methods such as salt spray and CASS, the electrochemical method such as EC test may be beneficial in terms of test time span and quantitative accuracy. Furthermore, EC test can also become the alternative method to evaluate the resistance to corrosion of coatings by measuring the corrosion potentials of the coated layers in the electrolyte during the off-time of EC cycles. Compared with the corrosion potentials of pure iron, nickel, chromium, those potentials of coated layers can be used to anticipate the extent of corrosion. Results showed that in terms of the test time span, EC test gave 14 times and 21 times faster results than the salt spray test in cases of $5\mu\textrm{m}$ Ni and $20\mu\textrm{m}$ Ni plated layers, respectively. In addition, EC test also offered the shorter test time span than CASS test in cases of $5 \mu\textrm{m}$ Ni + $0.5\mu\textrm{m}$ Cr, and $20\mu\textrm{m}$ Ni + $0.5\mu\textrm{m}$ Cr on Fe substrate by 78 times and 182 times, respectively. Therefore, EC test can be regarded as the better method to evaluate the resistance to corrosion of coated layers than the conventional methods such as salt spray and CASS.

흑색 황산3가크롬을 이용한 태양열 흡열판 선택흡수막 도금기술 (Technology of selective absorber coatings on solar collectors using black chromium+3 sulfate acid on substrates)

  • 엄태인;여운택;김동찬
    • 한국태양에너지학회 논문집
    • /
    • 제33권3호
    • /
    • pp.27-35
    • /
    • 2013
  • One of the most important factors that have a large influence on performance of the solar water heater system is performance of the solar collector, more detailedly, coating technology on the surface of the solar collector, which can provide high solar absorptance and low emittance. The core of the coating technology is to coat solar selective surfaces. In this study, various performance experiments are carried out using $Cr_2(SO_4)_3{\cdot}15H_2O$ coating technology. Here, IGBT(Insulated Gate Bipolar Transistor) of 5000A-15V was used as the surface processing rectifier which can stably output power and also can control voltage and current. The plating solution mainly contains black chrome$^{+3}$ concentration, H-y Conductivity, N-u Complex, NF Additive and NC-2 Wetter. Before applying the black chrome coating on the copper plate, optimal conditions are provided by using various preprocessing methods such as removal of fat, activation, electrolytic polishing, nickel strike, copper sulfate plating and bright neckel plating, and then the automatic continuous coating experiment are performed according to plating time and cathode current density. In the experiment, after the removal of fat, chemical polishing, nickel strike and activation processes as the preprocessing methods, the black chrome coating was performed in a plate solution temperature of $28^{\circ}C$ and a cathode current density of $18A/cm^2$ for 90 seconds. The thickness of chrome and nickel on the coated plate is $0.389{\mu}m$, $159{\mu}m$ respectively. As a result of the coating experiment, it showed the most excellent performance having a high solar absorptance of 98% and a low emittance of $5{\pm}1%$ when the black chrome surface had a thickness of $0.398{\mu}m$.

금속연료-피복재 상호확산 방지를 위한 크롬 도금법 적용 연구 (Cr Electroplating Technology to prevent Interdiffusion between Metallic Fuel and Clad Material)

  • 김준환;이강수;양성우;이병운;이찬복
    • 대한금속재료학회지
    • /
    • 제49권12호
    • /
    • pp.937-944
    • /
    • 2011
  • Studies have been carried out in order to reduce fuel-cladding chemical interaction (FCCI) behavior of metallic fuel in sodium-cooled fast reactors (SFR) using an electroplating technique. A $20{\mu}m$ thick Cr layer has been plated by the electrochemical method in the Sargent bath over the HT9 (12Cr-1Mo) clad material and diffusion couple tests of the U-10Zr metallic fuel as well as the rare earth alloy (70Ce-29La) have been conducted. The results show that the Cr plating can prevent FCCI behavior along the fuel-clad interface. However, cracks developed through the thickness during plating, which resulted in the migration of some fuel constituents. Variation of bath temperature, application of pulse current, and post heat treatment have been conducted to control such cracks. We found out that some conditions like the pulse current and the post heat treatment enhanced the layer property by reducing the internal cracks and improving the diffusion couple test.

우리나라 중소기업 도금공정 근로자의 크롬 및 세척제 폭로에 관한 연구 (A Study on Worker Exposure to Chromium and Degreasing Solvent at Eleetroplating Operation in Small Industry in Korea)

  • 백남원;정문식;이흥근;윤충식;정회경;이경희;이나루
    • 한국산업보건학회지
    • /
    • 제3권1호
    • /
    • pp.110-126
    • /
    • 1993
  • Worker exposures to total chromium, hexavalent chromium (VI), sulfuric acid and alkaline dust at electroplating operations and worker exposures to trichloroethylene (TCE) and methyl chloroform (MCM) at degreasing operations in eleven small industrial plants were evaluated. Appropriate local exhaust ventilation systems for both operations were designed and recommended. Results of the study are summarized as follows ; 1. Out of 134 measurements for airborne hexavalent chromium concentrations, seven were exceeding the Korean occupational health standard of $50{\mu}g/m^3$ and 45 were exceeding the NIOSH standard of $1{\mu}g/m^3$. With an exception of one measurement, concentrations of total chromium were below the Korean standard of $500{\mu}g/m^3$. 2. Worker exposures to chromium were closely related to the existing control methods at the electroplating operations. Local exhaust systems, partial coverage of the tank surface, and antifoaming agents on liquid surface were adopted as control methods. 3. With an exception of one sample, airborne concentrations of sulfuric acid and alkaline dusts were below the applicable occupational heatlth standards. 4. Three plants indicated that airborne concentrations of TCE and MCM were exceeding the Korean standards. Other plants showed lower concentrations than the standards. It should be noted that generally, the activities and workloads on the day of surveys were less than normal. 5. Since the most existing ventilation systems did not satisfy the ACGIH criteria, the ventilation systems should be improved. Some examples for designing appropriate ventilation systems are presented.

  • PDF

일부 영세 도금사업장의 국소배기성능과 공기중 총크롬, 6가 크롬 및 니켈농도와의 관계분석 (Evaluation on the Efficiencies of Local Exhaust Systems and Airborne Concentrations of Total Chromium, Hexa-valent Chromium and Nickel in Some Electroplating Plants)

  • 박동욱;박두용;신용철;오세민;정규철
    • 한국산업보건학회지
    • /
    • 제3권1호
    • /
    • pp.68-77
    • /
    • 1993
  • To evaluate efficiencies of the local exhaust systems installed in chromiun and nickel eletroplating tanks, specifications of each tank and general performances of the local exhaust systems were measured in 16 electroplating plants from July 3 to November 24, 1992. Airborne concentrations of total chromium, hexa-chromium and nickel were also measured, Most of the local exhaust systems installed in electroplating plants were inadequately designed. Average capture velocities of local exhaust systems in chromium and nickel tanks were 0.45 m/sec and 0.29 m/sec. Average slot velocities in chromium and nickel tanks were 7.30 m/sec and 2.87 m/sec repectively. Both average capture and solt velocities were in noncompliance with the standards recommened by American Conference of Governmental Industrial Hygienists (ACGIH) and National Institute for Occupational Safety and Health (NIOSH), Exhausted air volume was insufficient in all local exhaust systems surveyed. Worker exposure levels to total chromium, hexa-chromium and nickel were $43.0{\mu}g/m^3$, $1.7{\mu}g/m^3$ and $9.3{\mu}g/m^3$, which were below the Korean Standard and U.S. Occupational Health and Safety Administration (OHSA) Permissible Exposure Limit(REL). However, Worker exposure level to hexa-chromium exceeded the NIOSH Recommended Exposure Limit(REL) of $1{\mu}g/m^3$. As the result of Scheffee's multiple comparions, worker exposure levels to all metals were significantly different between two groups by the management state of existing local exhaust systems (p<0.05). However, Difference between a group with local exhaust systems which were poorly managed and another group without local exhaust system was satatistically non-significant.

  • PDF

30mm 자동포용 폐쇄기의 내구성 향상에 관한 연구 (A Study on Durability Improvement of Breech Block for 30mm Automatic Gun)

  • 박영민;김성훈;노상완;김성진
    • 한국산학기술학회논문지
    • /
    • 제21권5호
    • /
    • pp.47-53
    • /
    • 2020
  • 본 연구는 30mm 자동포에 적용 중인 폐쇄기의 내구성을 향상시킴으로서 제품의 신뢰성을 증가시키는 것을 목적으로 하고 있다. 연구 대상인 폐쇄기는 왕복운동을 통해 탄의 장전, 약실 폐쇄, 탄피 추출 등의 기능을 하는 포의 주요 구성품으로 높은 신뢰성이 요구되지만 운용 중 폐쇄기 균열이 조기에 발생됨에 따라 개선이 필요하였다. 개선을 위해 원인 분석을 수행하여 균열은 반복적인 충격에 의해 발생함을 확인하였다. 그러하여 다음과 같은 개선방안을 연구하고 입증 사격을 통해 효과를 증명하였다. 개선방안으로 소재 변경으로 충격 흡수에너지를 증가시켰으며 균열 부위의 R 값을 증대하여 응력 집중을 완화하였다. 또한, 쇼트피닝 추가, 크롬도금 삭제, 단조 방법 변경으로 피로수명을 증가시켰다. 개선품의 입증 사격 결과 5,000발까지 사격 장애가 발생하지 않았고 균열의 시작이 늦춰졌으며 그 깊이가 작아졌다. 따라서 개선방안이 적용된 폐쇄기는 기존 제품 보다 내구성이 향상됨을 확인하였다. 본 연구는 유사제품의 내구성 향상, 폐쇄기 균열 성장 속도 예측(수명 연구) 및 균열 허용 기준 설정을 추진할 때 유용한 참고 자료로 활용될 수 있을 것으로 기대된다.