• Title/Summary/Keyword: 쿨러

Search Result 115, Processing Time 0.041 seconds

A study on optimization design of sealing for sprinkler fire pipe system (스프링쿨러 소방 배관용 시일의 최적설계에 관한 연구)

  • Kim, Kyung-Seob;Kim, Chung-Kyun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.302-307
    • /
    • 2010
  • 본 연구는 최적설계 기법의 하나인 다구찌 방법을 이용하여 소방용 스프링클러 배관용 밀봉부에 대한 유한요소해석을 수행하고, 이를 통하여 소방용 배관의 밀봉안전성을 확보하고자 한다.

  • PDF

Performance Design of Aluminum EGR Cooler Consisting of Extruded Tubes for LPL EGR System (LPL EGR 시스템용 압출 튜브 구조의 알루미늄 EGR 쿨러 성능 설계)

  • Heo, Hyungseok;Bae, Sukjung;Kang, Taegu;Lee, Junyong;Seo, Hyeongjun
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.25 no.1
    • /
    • pp.42-50
    • /
    • 2017
  • A study has been conducted to develop an aluminum EGR cooler for the LPL EGR system of a diesel engine. Aluminum has a much lower density and thermal conductivity that is about 12 times or more than that of stainless steel, so it is advantageous for use in an EGR cooler for weight reduction and cooling performance effects. A design process has been carried out to ensure heat dissipation performance in a restricted space to investigate the geometric parameters and satisfy the requirements for pressure drops at both fluid sides. The tubes of exhaust gas have been designed as extruded tubes. An aluminum EGR cooler consisting of extruded tubes entails a simpler manufacturing process compared to a stainless steel EGR cooler with conventional heat transfer fins. A prototype has been manufactured from the final model selected through the design process. The performance of the aluminum EGR cooler was evaluated and compared with that of the conventional one. The weight of the aluminum EGR cooler is reduced by 22.9%, while performance is significantly improved.

고습도 유닛쿨러를 사용하는 저온저장고의 배 저장효과

  • Yoon, Hong-Sun;Lee, Won-Ok;Jung, Hoon;Lee, Hyun-Dong
    • Proceedings of the Korean Society of Postharvest Science and Technology of Agricultural Products Conference
    • /
    • 2003.04a
    • /
    • pp.140-140
    • /
    • 2003
  • 신선한 채소나 과일은 무게의 74~94%에 상당하는 수분을 함유하고 있는데, 이러한 수분은 자칫하면 빠져나가기 쉽다. 품질이 우수한 채소나 과일이라도 수분손실이 생기면 다시는 보충할 수 없기 때문에 겉껍질을 마르고 쭈글쭈글하게 되어 품질등급과 가격결정에 손해가 된다. 또 무게의 5~l0%까지 수분이 줄어들면 상품성을 잃게되고, 무게단위로 판매되는 채소와 과일은 수분손실이 곧 무게감소이므로 총수입도 줄어드는 원인이 된다. 따라서 채소나 과일을 수확 한 후에 수분손실이 생기지 않도록 잘 관리하는 것은 농가소득과 직결되는 중요한 일이다. 그러나 기존의 저온저장고들은 저장고 내의 상대습도가 70~85%의 범위로 조성되고 있으며, 이러한 저습도의 문제를 해결하기 위하여 저장고의 바닥에 물을 뿌리는 등의 작업을 하고 있으나 문제가 해결되지는 않는다. 이에 따라 농업기계화연구소에서는 저온저장고 내의 상대습도를 90% 이상으로 유지할 수 있는 유닛쿨러를 '01년에 개발하였고,'02~'03년에 이것을 실제로 농가의 저온저장고에 설치하여 그 효과를 실증하였는데 그 결과를 요약하면 다음과 같다. 1. 현장연구에 사용된 저온저장고는 천안시에 있는 이진기 농가의 25평형 배 저온저장고 2동이었으며, 한 동은 시험구로 한 동은 대조구로 사용하였다. 2. 배의 저장온도는 0~-0.2$^{\circ}C$이었고, 상대습도는 대비 저온저장고의 경우 75~90% 범위에 있었으나 신기술투입 저온저장고에서는 98%로 유지되었다. 또 냉각기에 생기는 얼음을 제거하기 위해 작동되는 전기히터의 작동시간은 대비 저온저장고에서는 하루에 7회, 회당 45분 씩 이었고, 신기술 투입 저온저장고에서는 하루에 1회, 회당 30분 씩 이었다. 3. 배를 플라스틱 상자에 담아 저장할 때 대비 저온저장고에서는 111일 동안에 11.7%의 중량감모가 발생하였으나, 신기술투입 저온저장고에서는 5.6%의 중량감모만이 발생하여 약 50%의 중량감모를 줄일 수 있었으며, 배의 색깔이나 경도도 대비구 보다 우수하였다. 4. 배를 비닐로 포장하여 대비 저온저장고에 저장한 경우와 비닐로 포장하지 않고 신기술투입 저온저장고에 저장한 경우를 비교할 때 11월~다음해 1월 까지는 중량감모, 과피색깔 및 경도에 큰 차이가 없었으나, 2월부터는 비닐로 포장하여 대비 저온저장고에 저장한 배의 품질변화가 급격히 증가되어 중량감모, 과피색깔 및 경도가 신기술 투입시 보다 급속하게 나빠졌다.

  • PDF

유전체장벽 방전구조의 비접촉식 저온 대기압 면방전 플라즈마를 이용한 빵곰팡이의 살균효과

  • Yu, Yeong-Hyo;Kim, Seong-Hui;Park, Gyeong-Sun;Choe, Eun-Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.519-519
    • /
    • 2013
  • 본 연구에서는, 전기적 충격이 없고 넓은 면적을 동시에 처리할 수 있는 형태의 유전체 장벽 방전(DBD: Dielectric Barrier Discharge)을 이용한 대기압 저온 플라즈마 장치를 제작하고 이를 이용하여 빵 곰팡이(Neurospora crassa) 살균에 대한 기본 분석을 하였다. 실험에 사용한 저온 대기압 면방전 플라즈마의 파워는 사인파 교류전압을 인가하여, 방전전압은 1.4~2.3 kV, 방전전류는 20~30 mA의 값을 가지며, 전압과 전류의 위상차는 약 80도의 기울기 차이가 난다. 이때의 출력은 약 4 W를 가지며, 공랭식 쿨러를 이용하여 유전체의 열을 배출하였다. 시료대의 온도 측정결과 방전과 동시에 쿨러를 작동할 경우 최대 10분에서 37도를 넘지 않았다. 장치에서 발생하는 플라즈마에 의한 O3의 양은 플라즈마 발생부로부터 10 mm 이내에서 약 25~30 ppm 이 측정되었으며, NO나 NO2 는 거의 검지되지 않았다. 증류수(Deionized water)속에 담긴 빵 곰팡이(Neurospora crassa) 포자를 면방전 플라즈마 발생장치로 처리하였을 때, 포자의 발아율은 처리시간 및 출력파워가 증가함에 따라 급격히 감소하였으나 VM (Vogel's Minimal) 배양액에 넣고 플라즈마 처리를 한 경우에는, 증류수의 결과와 달리 살균효과가 미비함을 보였다. MTT 측정법 또한 같은 경향성을 보였으며, 이를 통해 포자를 둘러싸고 있는 환경이 플라즈마의 살균효과에 영향을 미치는 것으로 보인다. 본 실험을 통해, 유전체 장벽을 이용한 면방전 플라즈마 발생장치가 플라즈마 제트(jet)와 달리 직접적인 플라즈마 접촉 없이도 미생물 살균이 가능하다는 것을 보았으며, 처리대상의 생체용액과 같은 주변 환경에 영향을 받음을 알 수 있었다. 또한 면방전 플라즈마 장치로부터 발생하는 O3과 같은 활성종들이 빵 곰팡이의 비활성화에도 역할을 할 수 있음을 알 수 있었다.

  • PDF

Precise Temperature Control of Oil Coolers with Hot-gas Bypass Manner for Machine Tools Based on PI and Feedforward Control (PI와 피드포워드 제어를 이용한 공작기계용 오일쿨러의 핫가스 바이패스 방식 정밀 온도 제어)

  • Jeong, Seok-Kwon;Byun, Jong-Yeong;Kim, Sang-Ho;Yoon, Jung-In
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.2
    • /
    • pp.111-119
    • /
    • 2011
  • Recently, the performances of speed and accuracy are enhanced in machine tools. The high speed of the machine tools usually causes harmful thermal displacements on the objects. To reduce the thermal displacements, machine tools generally adopt oil coolers with precise temperature control function. This study aims at precise control of oil outlet temperature in the oil coolers with hot-gas bypass manner based on PI control logic. The control system was designed for obtaining steady state error within ${\pm}0.1^{\circ}C$ and maximum overshoot with 0.8% even though abrupt disturbances are added to the system. We showed that the PI gains could be easily decided by numerical simulations using practical transfer function which got experiments. Also, transient characteristics could be improved significantly by reflecting the inlet temperature of an evaporator to the output of a controller feedforwardly considering periodic abrupt disturbances. Through some experiments, excellent control performances were established by the suggested control.

Optimization of a PI Controller Design for an Oil Cooler System with a Variable Rotating Speed Compressor (가변속 압축기를 갖는 오일쿨러의 최적 PI 제어기 설계)

  • Kwon, Taeeun;Jeong, Taeyoung;Jeong, Seokkwon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.12
    • /
    • pp.502-508
    • /
    • 2016
  • An optimized PI controller design method is presented to promote the control performance of an oil cooler system for high precision machine tools. First, a transfer function model of the oil cooler system with a variable rotating speed compressor was obtained by the perturbation method as the first order system with a negligible dead time. Then, the closed-loop control system was described as the second order system with a zero. Its dynamic behaviors are mostly governed by characteristic parameters, the damping ratio, and the natural frequency which is incorporated in PI gains. Next, an optimum integral of the time-weighted absolute error (ITAE) criterion was applied to the second order system. The characteristic parameters can be determined by the given design specifications, percent overshoots and settling times and comparisons with the ITAE criterion. Hence, the PI gains were plainly identified in a deterministic way. Finally, the PI gains were fine-tuned to obtain desirable dynamics in real systems, considering the zero effect and parameter variations. The validity of the proposed method was proven by computer simulations and real experiments for selected cases.

Performance Characteristics of Natural Gas Liquefaction Process using Liquid-gas Heat Exchanger (액-가스 열교환기를 적용한 천연가스 액화공정 성능 특성)

  • Yoon, Jung-In;Yoo, Sun-Il;Oh, Seung-Taek;Lee, Ho-Saeng;Lee, Sang-Gyu;Choi, Keun-Hyung
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.6
    • /
    • pp.44-48
    • /
    • 2009
  • In this paper, two different types of natural gas liquefaction cycle with 2 staged compression were designed and simulated to develop liquefaction process which is the core technology in the Industry of natural gas liquefaction plant. These include the cascade cycle with inter-cooler which is consisted of propane, ethylene and methane cycle. One of these is that liquid-gas heat exchanger is applied to between methane and ethylene cycles, and another is that liquid-gas heat exchanger is added to between ethylene and propane on the above process. Also, these cycles are compared with two staged cascade process using an inter-cooler. The COP of process2 is shown about 14.0% higher than that of process1, respectively. Also, the yield efficiency of LNG improved comparing with process1 with 11.5% lower specific power.

  • PDF

Durability Analysis through the Radiation of Heat of a Laptop (노트북에서의 방열을 통한 내구성 해석에 관한 연구)

  • Han, Moon-Sik;Cho, Jae-Ung
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.15 no.1
    • /
    • pp.89-94
    • /
    • 2016
  • This study investigates the durability of the radiator and cooler of a laptop through a thermal analysis. In the result of this study, the maximum deformation happened at the part holding up the support stand at the radiator and cooler. The maximum thermal stress of the cooler was 60.939 Mpa, as low as that of the radiator. In addition, the safety factor of the cooler was 1.64 times as high as that of the radiator. The radiator of the laptop was less durable than the cooler. The result of this study could help with designing a laptop model with a durable radiator and cooler.

PI Controller Design Based on Characteristic Parameters and Zero Position Adjustment for an Oil Cooler System (오일쿨러시스템의 특성근과 영점 조절에 의한 고성능 PI 제어기 설계)

  • Choi, Do-Kyung;Jeong, Seok-Kwon
    • Journal of Power System Engineering
    • /
    • v.20 no.4
    • /
    • pp.83-90
    • /
    • 2016
  • This study proposes a high-performance PI controller design method for an oil cooler system in conjunction with zero position adjustment and the characteristic parameters in its closed loop control system. The characteristic parameters included PI gains are decided by design specifications such as settling time and overshoot. The fine tuning on decided gains was performed by adjustment the zero position to get more desirable control performances. The simulations and experimental results show that the proposed PI controller design for an oil cooler system was possible to accomplish good control performances and to satisfy the design specifications.

A Study of the Temperature-Rise effects according to Firewall Installation in a Power Transformer (방화벽 설치 환경에 따른 초고압변압기 온도상승 영향 연구)

  • Kim, Chul-Sook;Lee, Seung-Ho;Kim, Joong-Kyoung
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.860-861
    • /
    • 2011
  • 방화벽은 변압기 폭발, 파열 사고 이후 주변 주/보조변압 기로의 2차 사고를 방지하는 목적으로 설치되고 있다. 변압기는 열교환기(방열기 또는 쿨러)를 통해 외부 대기와 열교환을 하므로 방화벽의 설치로 인하여 주위 대기의 흐름이 저하되어 냉각 성능에 악영향을 미칠 수 있다. 본 연구는 방화벽 설치 위치 및 변압기 주위 설치 환경에 따른 공기 온도상승 효과가 변압기의 온도상승에 미치는 영향에 대하여 분석하였다. 시험과 해석을 수행한 결과 방화벽을 2면으로 설치 할 경우 방화벽의 설치 거리는 방열기에서 1m 이상, 방화벽을 3면으로 설치 할 경우 변압기 본체에서 2.5m 이상으로 유지하였을 때 변압기의 온도상승에 큰 영향을 미치지 않음을 확인하였으며, 방화벽의 높이는 본체의 높이를 고려하여 설치하여야 한다.

  • PDF