• Title/Summary/Keyword: 코어 재료

Search Result 248, Processing Time 0.03 seconds

Complication and Failure Analysis of Endodontically Treated Teeth Restored with Post and Cores (포스트로 수복한 근관 치료된 치아의 임상적 상태에 대한 평가)

  • Yun, Mi-Jung;Kim, Mu-Hyon;Jeong, Chang-Mo;Huh, Jung-Bo;Jeon, Yeong-Chan
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.4
    • /
    • pp.359-370
    • /
    • 2012
  • The endodontically treated tooth is generally restored with post and core, owing to the brittle and the loss of large amount of tooth structure. The purpose of this study was to evaluate the clinical status of fixed prostheses to improve the quality of dental care. In order to assess the clinical status of fixed prostheses, a total of 101 individuals (aged 30-89, 66 women and 35 men loaded with 125 fixed prostheses) who treated in the Department of Prosthodontics, Pusan National University Dental Hospital, between January 1990 to December 2005 were examined. The results of this study were as follows: 1. Length of service of fixed prostheses was $9.7{\pm}3.4$ years (mean), 11.1 years (median). 2. Age and sex of patient was found to have no statistically significant influence on longevity of fixed prostheses (P>.05). 3. Location of fixed prostheses was found to have statistically significant influence on longevity of fixed prostheses (P<.05). The longevity of fixed prostheses was low in anterio-posterior combination region (median:9.2 years). 4. Longevity of fixed prostheses made of base metal ceramic(median:12.0 years) and noble metal ceramic (median:11.3 years) is long (P<.05). 5. Number of units in fixed prostheses was found to have no statistically significant influence on longevity of fixed prostheses (P>.05). 6. Condition of opposing dentition was found to have no statistically significant influence on longevity of fixed prostheses (P>.05). 7. Dental caries, periapical disease, tooth fracture were frequent complications. In 51.9% of the cases, abutment state after removing fixed prostheses was needed to be extracted.

Evaluation using Replica Technique on the marginal and internal fitness of zirconia cores by several CAD/CAM systems (수종의 CAD/CAM 시스템으로 제작한 지르코니아 코어에서 Replica Technique을 이용한 변연 및 내면 적합도 평가)

  • Huh, Jung-Bo;Park, Cheong-Gil;Kim, Ha-Young;Park, Chan-Kyung;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.2
    • /
    • pp.135-142
    • /
    • 2010
  • Purpose: This study was aimed to compare the margin and internal fitness of single anterior all-ceramic crown zirconia core made by three deferent CAD/CAM systems. Material and methods: Five single zirconia cores were manufactured by three deferent CAD/CAM systems($Cerasys^{(R)}$system, KaVo $Everest^{(R)}$system, $LAVA^{TM}$system). The manufactured zirconia cores were duplicated through the use of replica technique, and a replicated sample was sectioned in the center of bucolingual and mesiodistal direction to measure the marginal and internal gap. Measurement was carried out by using measuring microscope ($AXIO^{(R)}$) and $I-Solution^{(R)}$ and analysed through the use of ANOVA. Results: As for the mean marginal fitness of the zirconia core, it was $84.74{\pm}27.57{\mu}m$, in $Cerasys^{(R)}$, $80.23{\pm}21.07{\mu}m$ in KaVo $Everest^{(R)}$ and $96.37 {\pm}11.45{\mu}m$ in $LAVA^{TM}$, and as for the mean internal gap, it was $94.11{\pm}30.07{\mu}m$ in $Cerasys^{(R)}$, $92.31{\pm}25.18{\mu}m$ in KaVo $Everest^{(R)}$, and $94.99{\pm}18.74 {\mu}m$ in $LAVA^{TM}$. There was no significant statistically deference among the total average gap of three systems. The internal gap in KaVo $Everest^{(R)}$ seemed to be smaller than $LAVA^{TM}$ (P < .05). The internal gap in the incisal area was larger in all of the three systems. Conclusion: There was no difference in marginal fitness in $Cerasys^{(R)}$, KaVo $Everest^{(R)}$ and $LAVA^{TM}$. As for the internal fitness, it was smaller in KaVo $Everest^{(R)}$ system than $LAVA^{TM}$ system. In all of the three systems, there was a larger gap in incisal area. The marginal and internal gap was within the clinically allowed range in all of the three systems.

A Study on Flame Retardant Treatment on Bamboo Nonwoven Fabric and Manufacturing of Sandwich Structure Composites (대나무 섬유의 난연화 및 샌드위치 구조 복합재료 제조연구)

  • Lee, Dong-Woo;Prabhakar, M.N.;Song, Jung-Il
    • Composites Research
    • /
    • v.33 no.6
    • /
    • pp.408-414
    • /
    • 2020
  • The present engineering sector focused on the sandwich composites and almost covered all engineering fields because of decent mechanical properties with a lightweight structure. It mainly consists of high strength fiber skin and porous structure core like corrugated, honeycomb, balsa wood, and foams which is playing a pivotal role in weight reduction. Recently researchers attention grabbed by Natural fiber sandwich composites due to biodegradability, renewable, low-cost, and environmentally friendly. However special focus is highly needed towards the flammability behavior of natural fibers used as reinforcement for composites. Herein, for the first time, the flame retardant natural fiber sandwich composite was fabricated by using flame retardant treated bamboo fabric and vinyl ester via the VARTM process. The impact of flame retardant treated bamboo fabric on mechanical and flame retardant properties were studied. The results concluded that the fabricated bamboo sandwich composites show structurally lightweight with significant mechanical strength and feasibility with respect to the flame.

Seismic Techniques for the Integrated Assessment of Structural Integrity of Concrete Runway (콘크리트 활주로 건전도상태의 종합평가를 위한 비파괴 탄성파기법)

  • Joh Sung-Ho;Kang Tae-Ho;Cho Mi-Ra;Suh Young-Chan;Kwon Soo-Ahn
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.4
    • /
    • pp.51-63
    • /
    • 2005
  • Concrete pavement may suffer from material deterioration or structural problems, which lead to surface cracks and deflection of a concrete pavement. Degraded concrete pavement, when it is still under operation, should be recovered by an urgent maintenance to avoid the discontinued service leading to the significant traffic problems and economic loss. Seismic techniques are good tools to assess the structural integrity of concrete runway. It is because seismic techniques can evaluate engineering properties nondestructively and quickly and the evaluation can be extended to subgrade. In this study, a series of numerical simulations of stress-wave propagation were performed to verify feasibility of seismic techniques as an assessment tool. Based on the results of the numerical simulation, a framework of using seismic techniques was presented fur the nondestructive integrated assessment fur structural integrity of concrete runway. And the presented framework was applied to $\bigcirc\bigcirc$ concrete runway with surface cracks, which required urgent maintenance, to identify the causes of the surface cracks. The results obtained from the structural integrity assessment were compared with the measurements of the cores collected from the same runway for verification of the presented framework.

A Study for In-situ Application of High Strength Antiwashout Underwater Concrete (고장도용 수중불분리성 콘크리트의 현장적용을 위한 연구)

  • 문한영;송용규;이승훈;정재홍
    • Journal of the Korea Concrete Institute
    • /
    • v.13 no.4
    • /
    • pp.336-345
    • /
    • 2001
  • The construction of underwater structures has been increased, but underwater concrete hassome problems of quality deterioration and contamination around in-situ of civil and architecture; therefore, new materials and methods for them are demanded. In this paper in-situ application of underwater antiwashout concrete which is manufactured for trio purpose of not only decreasing suspended solids and the heat of hydration but also increasing long term strength was studied. In the case of mock-up test(Ⅰ), when underwater antiwashout concrete, whose slump flow was 58 cm, was placed in the mock-up test at a speed of 24 ㎥/hr, it took about a minute to flow to the side wall, and the surface was maintained at horizontal level. In this case, compressive strength of the core specimens in each section was higher than the standard design compressive strength of 240 kgf/㎠. In the case of mock-up test(II), pH value and suspended solids of high strength underwater antiwashout concrete were 10.0∼11.0 and 51 mg/ℓ at 30 minutes later, initial and final setting time were about 30, 37 hr, and the slump flow of that was 53$\pm$2 cm. In the placement at a speed of 27 ㎥/hr, there was no large difference in flowing velocity, with or without reinforcement and flowing slope was maintained at horizontal level. In this case, compressive strength and elastic modulus of the core specimens somewhat decreased as flowing distance was far : however, those of central area showed the highest value.

Ultra Precision Machining of Optical Pick-up Aspheric Glass Objective Lens Molding Press Core for Optical Information Storing (I) (광정보저장용 광픽업 대물렌즈 성형용 코어 초정밀 형상가공 (I))

  • Kim, Min-Jae;Lee, Jun-Key;Hwang, Yeon;Kim, Hye-Jeong;Kim, Jeong-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.290-290
    • /
    • 2009
  • Blu-ray Disk, the next generation optical information storing equipment used Blu-ray is the next generation leading storing equipment that has capacity is about from six times to thirty-five times bigger than the existing CDs, DVDs. Especially, we need elaborate optical pick-Up equipment to record and recognize detailed date. Moreover, Blu-ray disk has so narrow track-pitch so it is used high NA(Numerical Aperture) aspheric glass objective lens. In this research, we processed optical pick-up aspheric glass objective lens molding press core by parallel grinding method with ultra precision machining and mold core surface measured form accuracy(PV), surface roughness(Ra).

  • PDF

A Study on Influence of PV and Ra with Re-Ir Coating of WC Core Surface for Glass Molding Lens (성형용 초경합금(WC) 코어면의 Re-Ir 코팅이 형상정도와 표면조도에 미치는 영향에 관한 연구)

  • Kim, Hyun-Uk;Kim, Sang-Suk;Kim, Hye-Jeong;Kim, Jeong-Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.9
    • /
    • pp.808-811
    • /
    • 2007
  • Aspheric glass lens have recently been used in camera phone module because they are more effective than spherical ones. In this paper, the grinding condition of the tungsten carbide molding core has been found after applying DOE to the development of the aspheric glass lens for the 3 Megapixel and 2.5x camera-phone module. Also, the ultra precision grinding process was investigated under this condition by experiment. Re-Ir coating was applied on the ground surface of the tungsten carbide molding core. The influence of Re-Ir coating on the form accuracy and surface roughness of molding core was compared and evaluated. The form accuracy and surface roughness of the molding core were improved by application of Re-Ir coating on the surface of the tungsten carbide molding core.

Impact Damage of Honeycomb Sandwich Antenna Structures (통신 안테나용 허니콤 샌드위치 구조물의 충격 손상에 관한 연구)

  • 조성재;김차겸;박현철;황운봉
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2001.05a
    • /
    • pp.74-77
    • /
    • 2001
  • The impact response and damage of CLAS panel was investigated experimentally. The facesheet material used was RO4003 woven-glass hydrocarbon/ceramic and the core material was Nomex honeycomb with a cell size of 3.2mm and a density of 96 kg/$\textrm{m}^{3}$. The shield plane used was RO4003 and 2024-T3 aluminum. Static indentation and impact test was conducted to characterize the type and extent of the damage observed in two CLAS panels, and the performance of antenna used in a wireless LAN system. Correlation of peak contact force, residual indentation and the delamination area shows impact damage of the panel with an aluminum shield plane is larger than that of the panel with RO4003 shield plane, although tile former is more penetration resistant. The damage was observed by naked eye, ultrasonic inspection and cross sectioning. The shape and size of delamination was estimated by ultrasonic inspection, and the area of delamination linearly increases as impact energy increases. The performance of impact damaged antenna was estimated by measuring return loss and radiation pattern.

  • PDF

Dependence of Round type electrodeless lamp according to ferrite core and cold spot temperature (둥근형 무전극 램프의 페라이트 코어와 냉점의 온도 의존성)

  • Oh, Seul-Yi;Kim, Nam-Goon;Yang, Jong-Kyung;Jung, Young-Il;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.04a
    • /
    • pp.65-69
    • /
    • 2009
  • Generally Lighting system consists of lamp and luminaire. When a fluorescent lamp is installed in luminaire, power and light output is changed by ambient temperature. Particularly electrodeless lamp depends on the changes that are mercury pressure with amalgam temperature and magnetic properties with ferrite temperature. It has finally influence on optical efficiency. In this study, the temperature change of ferrite and cold spot, vessel are measured at transitional state and then same characteristics are measured with increase of ambient temperature. At transitional state, luminous flux is related to temperature change of cold spot that compare with behavior of mercury pressure and light output. At increase of ambient temperature, we analyzed change that efficiency and electrical, optical characteristics of electrodeless lamp are related to ferrite core and cold spot temperature.

  • PDF

Hydrothermal Reduction of $\Co(OH)_2$ to Cobalt Powder Preparation ($Co(OH)_2$로부터 수열법에 의한 코발트 분말제조)

  • Kim, Dong-Jin;Chung, Hun-Saeng;Yu Kening
    • Korean Journal of Materials Research
    • /
    • v.9 no.7
    • /
    • pp.675-679
    • /
    • 1999
  • An investigation was performed to prepare spherical cobalt powder with about particle size of 400nm from aqueous cobalt hydroxide slurry under hydrothermal reduction conditions using palladium chloride as a catalyst. The reduction kinetics was in good agreement with a surface reaction core model equation. and the activation energy obtained from Arrhenius plots was 55.6 KJ/mol at the temperature range of $145~195^{\circ}C$. Additionally, the study showed that the cobalt reduction rate is proportional to the initial hydrogen pressure with a reaction order of n=0.63. which corresponds to the gas chemisorption reaction type.

  • PDF