• Title/Summary/Keyword: 코라

Search Result 2,739, Processing Time 0.029 seconds

Setting Time and Compressive Strength Gains of Glycocalix Coating Materials with Silica-based Accelerating Agents (실리케이트계 급결제를 혼입한 글라이코 캘릭스 코팅재의 응결시간 및 압축강도 발현 특성)

  • Jeong, Yun-Ji;Yoon, Hyun-Sub;Yang, Keun-Hyeok
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.8 no.1
    • /
    • pp.105-111
    • /
    • 2020
  • The present study examined the effect of the silica-based accelerating agents on the setting time and compressive strength gain of biomimetic glycocalix coating materials that has been developed for protecting the substrate of concrete exposed to chemical and microbiological attacks. The accelerating agent contents varied from 10mL/L to 40mL/L in the mixtures of glycocalix coating materials determined for shotcrete and lining techniques. Test results showed that the setting time of coating materials containing accelerating agents was affected by the contents of the bacteria carrier. When the accelerating agent content was 40mL/L, the final setting time was 80 minutes for shotcrete mixtures and 318 minutes for lining mixtures. Meanwhile, the compressive strength gain of coating materials with accelerating agents tended to be lower than that of counterpart materials without accelerating agents.

A Study on the Speech Recognition for DDD Area - Name Using Vector Quantization with Time Information (시간 정보와 VQ를 이용한 DDD 지역명 인식에 관한 연구)

  • LEE S. K.;LEE K. S.;ANN T. O.;CHO H. J.;BYON Y. C.;KIM S. H.
    • The Journal of the Acoustical Society of Korea
    • /
    • v.8 no.5
    • /
    • pp.102-112
    • /
    • 1989
  • In this paper, we proposed the study on speaker-independent isolated word recognition for DDD area-name using vector quantization and chose total 146 DDD area-name to recognize words for application of dialing system. We made the codebook using 12th LPC cepstrum coefficients and used the minsum and the minimax method to find the centroid and we applied 3 splitting rule to a codebook generation. The single section and the multi section with time information were used to generate the codebooks and the over-lapped section codebook was used, too. From the experiment result, we proved that the minsum method was better than the minimax method and the evaluation of the system yielded an accuracy of about 90 percents In case of speaker-independent.

  • PDF

Design of a compact coplanar waveguide-fed 2-element quasi-Yagi antenna (코플래너 도파관으로 급전되는 소형 2-소자 준-야기 안테나 설계)

  • Baek, Woon-Seok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.12
    • /
    • pp.2199-2205
    • /
    • 2016
  • In this paper, a design method for a coplanar waveguide (CPW)-fed 2-element quasi-Yagi antenna (QYA) is studied. A balun between CPW and coplanar strip (CPS) which feeds a planar dipole is implemented by connecting the one end of ground strips in a CPW to a signal strip. The antenna size is reduced by bent strip dipole and reflector, and an integrated balun. The proposed antenna was designed for the operation in a UHF radio frequency identification (RFID) band of 902-928 MHz, and the effects of various parameters such as dipole length, reflector length, distance between dipole and reflector, feed position were examined. The antenna with a size of $90mm{\times}80mm$ was fabricated on an FR4 substrate, and the experiment results reveal a frequency band of 885-942 MHz for a voltage standing wave ratio < 2, a gain > 4.3 dBi, and a front-to-back ratio > 7 dB over the frequency band for the UHF RFID.

Numerical Analysis on Temperature Characteristics of the Voice-Coil for Woofer Speaker Using Ferrofluid (자성유체를 이용한 우퍼 스피커의 보이스 코일 온도 특성에 관한 수치적 연구)

  • Lee, Moo-Yeon;Kim, Hyung-Jin;Lee, Woo-Young
    • Journal of the Korean Magnetics Society
    • /
    • v.23 no.5
    • /
    • pp.166-172
    • /
    • 2013
  • This article is to numerically investigate the temperature and heat transfer characteristics of the voice coil in the woofer speaker using ferrofluid with the input currents. The temperature and heat transfer of the major components of the woofer speakers with and without ferrofluid are calculated and analyzed with the increase of the input currents from 10 W to 50 W at an interval of 10W. As results, the temperature of voice coil is linearly increased with an increase of input currents. The temperature of the woofer speaker with ferrofluid is lower 51.0 % than that of the woofer speaker without ferrofluid at the condition of input current 40W and the required input current of the woofer speaker with ferrofluid is lower 42.5 % than that of the woofer speaker without ferrofluid at the condition of voice coil temperature 490 K. In addition, the heat transfer from voice coil to other components for woofer speaker with ferrofluid is higher 51.7 % than that for woofer speaker without ferrofluid.

Single Layer Array of Transmitting and Receiving Spiral Coils for Magnetostrictive Type Long-Range Ultrasonic Testing (자왜방식 원거리 초음파검사를 위한 단층 송수신 나선형 코일 배열)

  • Choi, Myoung Seon;Kim, Yoo Jin;Lee, Hyo Moon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.2
    • /
    • pp.219-225
    • /
    • 2013
  • Separate and layered transmitting and receiving spiral coil arrays had been used for the optimized individual applications of magnetostrictive type long-range ultrasonic testing. In this study, it was demonstrated that when taking advantages of the spiral coils with the leg width reduced to be half of the previous one and of the empty spaces due to the decrease of leg width, the transmitting and receiving coil array can be arranged to form a single layer structure allowing more easy use and fabrication. Because of the number of turns of the receiving coils that is proportional to their leg width, the sensitivity of the single layer coil array was about half that of the corresponding double layer coil array while it allowed the receiving amplifier to get faster recovery from a saturation due to the main bang echo. It was also found that the two types of coil arrays have almost the same performances in the view points of signal-to-noise ratio and directivity control.

Three-dimensional Locomotion and Drilling Microrobot Using Electromagnetic Actuation System (전자기 구동 시스템을 이용한 마이크로로봇의 3차원 이동 및 드릴링)

  • Li, Jie;Choi, Hyun-Chul;Cha, Kyoung-Rae;Jeong, Se-Mi;Park, Jong-Oh;Park, Suk-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.12
    • /
    • pp.1573-1578
    • /
    • 2011
  • In this study, a novel electromagnetic microrobot system with locomotion and drilling functions in threedimensional space was developed. Because of size limitations, the microrobot does not have actuator, battery, and controller. Therefore, an electromagnetic actuation (EMA) system was used to drive the robot. The proposed EMA system consists of three rectangular Helmholtz coil pairs in x-, y- and z-axes and a Maxwell coil pair in the z-axis. The magnetic field generated in the EMA coil system could be controlled by the input current of the EMA coil. Finally, through various experiments, the locomotion and drilling performances of the proposed EMA microrobot system were verified.