• Title/Summary/Keyword: 케이블 화재

Search Result 97, Processing Time 0.027 seconds

A Study on the Safety Checking and Testing method of the underground power transmission line (OF Cable) (지중송전선로 안전관리 방안 (OF케이블))

  • Choi, Jong-Soo;Park, Kang-Seo;Jeon, Jun-Man
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.429-434
    • /
    • 2009
  • In this paper it was written about the safety management plan for underground power transmission cable, and it guarantees the reliable electric power supply and facility management to prevent an electric disasters according to that. Recently fires which happens on OF Cable lead to a breakdown of power system and cause a power outage of wide area and serious social problems. So it needs an improvement of inspection ability on OF cable as well as a strict inspection system to prevent that problems in advance and it will bring us the development of electric safety management and the reliable electric power supply.

  • PDF

Analysis of Monitored Insulation Data Using Standard Deviation of Leakage Current Data in High-Power Cables at a Thermoelectric Power Station (화력발전소 고전력 케이블의 누설 전류 측정 데이터의 표준 편차값을 사용한 절연감시 데이터 분석)

  • Kim, Bo-Kyeong;Um, Kee-Hong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.2
    • /
    • pp.245-250
    • /
    • 2017
  • From the instant of installation and operation, power cables start deteriorating. Cable systems can be maintained not only by monitoring the insulation status of the insulation layer and oversheath, but also the insulation status of the terminal and junction in high-voltage power cables. When the cable system (the cable itself and cable junctions combined) deteriorates, fire accidents happen due to dielectric breakdowns. We have invented a device to monitor the deteriorating status of cables, and installed it at Korea Western Power Co. Ltd. located in Taean, Chungcheongnam-do Province. In this paper, we present the results obtained using our device, through analysing and calculating the standard deviation of leakage current from cable insulators attached to the cables. When the standard deviation of analysed leakage current falls below a critical value, a cable system is deemed to be operating safely. But when the standard deviation of analysed leakage current is larger than the critical value, the insulation status of the terminal and junction in the cable system is considered to have seriously deteriorated. The terminal and junction in the relevant system should then be replaced preemptively in order to prevent blackout accidents of cables caused by the suspension of power supply.

CCDP Evaluation of the Eire Area of NPPs Using Eire Model CEAST (화재모델 CFAST를 이용한 원전 화재구역의 CCDP평가)

  • Lee Yoon-Hwan;Yang Joon-Eon;Kim Jong-Hoon;Noh Sam-Kyu
    • Fire Science and Engineering
    • /
    • v.18 no.4
    • /
    • pp.64-71
    • /
    • 2004
  • This paper describes the result of the pump room fire analysis of the nuclear power plant using CFAST fire modeling code developed by NIST. The sensitivity studies are performed over the input parameters of CFAST: the constrained or unconstrained fire, Lower Oxygen Limit (LOL), Radiative Fraction (RF), and the opening ratio of the fire doors. According to the results, a pump room fire is the ventilation-controlled fire, so it is adequate that the value of LOL is 10% which is also the default value. It is anlayzed that the Radiative Fraction does not affect the temperature of the upper gas layer. It is appeared that the integrity of the cable located at the upper layer is maintained except for the safety pump at the fire area and the Conditional Core Damage Probability (CCDP) is 9.25E-07. It seems that CCDP result is more realistic and less uncertain than that of Fire Hazard Analysis (FHA).

The cause analysis of explosion on junction termination of 345kV cable (345 kV 케이블 종단접속부에서의 폭발사고 원인분석)

  • Shong, Kil-Mok;Bang, Sun-Bae;Kim, Chong-Min;Kim, Young-Seok;Choi, Myeong-Il
    • Congress of the korean instutite of fire investigation
    • /
    • 2010.12a
    • /
    • pp.63-79
    • /
    • 2010
  • It is found to the arc trace on the junction termination of 345kV cable. According to the analysis of the cable material is judged to be good. Manufacturing and design problems are not considered. In construction defects, it was estimated to the low level of insulation oil. In the majority of the arc trace appeared XLPE is found. However, there is no Soots mark, yellow band has not been confirmed, not associated with a radial arc of the spider leg is not evidence. In other opinions, void, contamination or jut are not found on the inside of XLPE. Thus, by the attachment of the impurities in surface of XLPE insulation is judged to the breakdown.

  • PDF

A Study on Fluidized Bed Process Powder Coating Insulation and Electrical Degradation Properties for Bus Duct (부스닥트용 유동침적방식의 절연 및 열화 특성연구)

  • Kang, Chul-Hwa;Choi, Ji-Hyun;Park, Ji-Kun;Ju, Hyun-Don;Kim, Hyun-Hee
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.413-416
    • /
    • 2011
  • 대용량 기기의 효율적인 전력 공급을 위해 부스닥트의 수요가 급증하고 있으며, 특히 컴팩트형 부스닥트는 케이블에 비해 무게와 부피가 가볍고 전력 효율도 25% 이상 우수하며, 기술의 핵심은 에폭시분체도료의 절연 특성 향상과 제작공정의 최적화와 안정화이다. 따라서 본 연구에서는 유동침적방식(Fluidized Bed Process)에 대한 최적화와 에폭시 분체도료의 절연설계 및 열화특성에 대해 실험 검토 하였다. 또한 전기화재의 주된 원인인 아크방전특성과 절연파괴 특성에 대한 분석과 더불어 다양한 상용제품들의 특성을 비교하였다.

  • PDF

A Study on the Automatic Fire System Development using the PIC Chip (PIC를 사용한 자동 소화 시스템 개발에 관한 연구)

  • Kim, Hyeon-Ho;Jang, In-Gab
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2006.11a
    • /
    • pp.291-294
    • /
    • 2006
  • 본 연구는 화재로부터 인명과 재산을 보호하기 위한 자동 소화 시스템으로서 마이컴을 사용하여 고신뢰성, 고정밀도, DIGITAL화를 추구하는 시스템을 개발 하였다. 기존의 소화 방제 시스템들은 스프링클러를 사용하여 물로 화재를 진압하고 있으며 이러한 시스템은 비용이 많이 들고 대량의 물을 사용하고 있기 때문에 수손피해($80{\sim}120{\ell}/min$)가 있고 대용량 펌프 및 $47,000{\ell}$의 저장시설이 필요하다. 이러한 문제점을 해결하기 위하여 본 시스템은 이산화탄소($CO_2$ 가스나 하론1301 가스 또는 질소 가스를 분사하여 대기 중의 산소를 희석시키거나 질소의 양을 증가시키는 방법으로 화재를 진압하는 시스템을 개발 하였다. 개발된 시스템은 고가의 장비 즉, 전산실, 통신기기실, 전기실, 발전기실, 케이블실, 제어실, 필름 보관실 등에 사용되어 장비를 보호하고 인명의 피해를 최소화하는데 사용될 것 있다.

  • PDF

Development of Cable Tunnel Monitoring System (통신구 원격감시 시 스템 개발 및 시범운용)

  • Park, Jung-Kwon;Han, Jin-Woo;Park, Jong-Ho
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.306-309
    • /
    • 2007
  • 지하구에는 국 가의 신경이라 할 수 있 는 전력, 통신, 상수도 등 주요시설물들이 수용되어 있으며, 지 하구는 화재, 집중호우에 의한 침수, 외부침입 등의 재난에 항상노출되어 있다. 2006년 12월에 발생된 구리 전력구 화재와 2000년 여의도 공동구 화재 등에서 보듯이 화재가 발생하면 화염과 연기, 유독가스로 인해 내부로 진입할 수 없으므로 조기경보 및 조기 대처가 매우 중요하다. 따라서 본 논문에서는 지하구 중에서 통신케이블을 수용하는 통신구의 재난에 조기 대처할 수 있는 통신구 원격감시 시스템에 대해 기술하고자 한다. 통신구 원격감시 시스템은 통신구내의 침입, 침수, 화재 등을 모니터링하여 재난을 미연에 방지할 수 있도록 하고, 각 감지기 및 장치에 설정된 임계치를 초과한 경우 경보 현황을 운용자에게 알려 신속하게 조치할 수 있도록 하였으며, 시스템의 안정성과 확장성, 유지보수의 용이성 등을 고려하여 통합/분산 서버, 데이터 수집장치, 감지기 등 으로 구성 하였고, 시스템간의 연동과 호환성을 위해 표준화된 통신 프로토콜을 사용하였으며, 필요에 따라 감지기 및 장치를 수정, 추가할 수 있도록 개발하였다. 그리고 이를 검증하기 위해 부산지역의 지하철병행통신구 3.8km에 대해 시범설치하여 운용함으로써 시스템의 안정성, 운용성 등에 대해 검증하였다.

  • PDF