Determination of Explosive Weight for Cable Cutter through Impact Test (Impact Test를 통한 케이블커터의 화약량 산정)

  • Choi, Chang-Sun
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.16 no.4
    • /
    • pp.16-22
    • /
    • 2012
  • We performed impact test to estimate necessary explosive charge weight for cutting the cable whose diameter is 22 mm. The impact test results were analyzed by Probit method. The cutting energy was calculated 37.7 J with 99.99% probability at 99% reliability compared to the average energy of 24.9 J. The cable was cut 3 times without failure with 150 mg of Zirconium Potassium Perchlorate (ZPP), which was considered to generate 24.5 J of mechanical energy with assumption that only 10% of explosive energy converts to mechanical energy. The calculated energy from measured pressure with 150 mg ZPP was 26.1 J, which is almost same with both impact test result and expected mechanical energy. We can argue that the cable can be cut with 99.99% probability at 99% reliability by 230 mg of ZPP.

Statistical analysis of the energy for cable cutting (케이블 절단에 필요한 에너지 통계적 분석)

  • Choi, Chang-Sun;Kang, Won-Kyu
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.400-403
    • /
    • 2011
  • We performed Instron and Impact tests to estimate necessary explosive charge weight for cutting the cable whose diameter is 22 mm. The cutting energy measured by Instron was 21.3 J. Impact test were performed 8 times each at 5 different energies. The Impact test results were analysed by Probit methods. The cutting energy was calculated 37.7 J with 99.99% probability at 99% confidence, which is roughly equivalent to 250 mg of Zirconium potassium Perchlorate (ZPP).

  • PDF