• Title/Summary/Keyword: 컴퓨터 단층 영상

Search Result 377, Processing Time 0.042 seconds

Immunoglobulin G4-Related Lung Disease with Waxing and Waning Pulmonary Infiltrates: A Case Report (호전과 악화를 반복하는 폐 병변을 가진 면역글로불린 G4 관련 폐 질환: 증례 보고)

  • John Baek;Jongmin Park;Byunggeon Park;Jae-Kwang Lim;Chun Geun Lim;An Na Seo
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.6
    • /
    • pp.1373-1377
    • /
    • 2023
  • Immunoglobulin G4 (IgG4)-related lung disease can have various clinical courses. To our knowledge, reports of IgG4-related lung disease with waxing and waning pulmonary infiltrates only are very rare. A few lung nodules and ground glass opacities were incidentally found in a pre-operative evaluation in a 36-year-old female. The lung lesions showed waxing and waning in the follow-up chest CT. She underwent a surgical biopsy, and IgG4-related lung disease was confirmed.

Primary Malignant Peripheral Nerve Sheath Tumor of the Pulmonary Vein: A Case Report (폐정맥의 원발성 악성 말초신경초종: 증례 보고)

  • Hyun Woo;Hyeyoung Kwon;Jin Hwan Kim;Song Soo Kim;Hyung Kyu Park;Younju Rhee;Jae-Hyeong Park
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.6
    • /
    • pp.1384-1390
    • /
    • 2023
  • Primary masses rarely originate from the heart and great vessels, and a malignant peripheral nerve sheath tumor (MPNST) is extremely rare. A 76-year-old male with pleural effusion underwent contrast-enhanced computed tomography, which revealed a hypoattenuating mass involving the right pulmonary vein and left atrium. Ultrasonography showed that the mass originated from the right pulmonary vein. Surgical resection confirmed an MPNST that originated from the pulmonary vein. We report the first Korean case of a primary MPNST originating from the pulmonary vein. We have also described the radiologic findings suggestive of a pulmonary vein mass.

Ciliated Foregut Cyst and Accessory Spleen in the Pancreas: A Case Report and Literature Review (췌장에서 발생한 부비장과 동반된 섬모성 전장낭: 증례 보고와 문헌고찰)

  • Hyun Jin Kim;Heejin Kwon;Kyungjae Lim;Jinhan Cho;Min Gyoung Pak;Kwan Woo Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.1
    • /
    • pp.263-269
    • /
    • 2023
  • Ciliated foregut cyst is a relatively rare disease; thus, most reports are in the form of case studies. This benign cyst is usually found in the mediastinum and account for approximately 20% of all mediastinal masses. However, it is rarely found in the hepatobiliary and peripancreatic regions. Approximately 20 cases of ciliated foregut cysts involving the pancreas have been reported in the Enlgish literature. Here, we present a case of ciliated foregut cyst that occurred in the tail of the pancreas in a 29-year-old female. The patient's ultrasonography, CT, and MRI findings are presented, along with a review of the literature.

Micro-CT System for Small Animal Imaging (소동물영상을 위한 마이크로 컴퓨터단층촬영장치)

  • Nam, Ki-Yong;Kim, Kyong-Woo;Kim, Jae-Hee;Son, Hyun-Hwa;Ryu, Jeong-Hyun;Kang, Seoung-Hoon;Chon, Kwon-Su;Park, Seong-Hoon;Yoon, Kwon-Ha
    • Progress in Medical Physics
    • /
    • v.19 no.2
    • /
    • pp.102-112
    • /
    • 2008
  • We developed a high-resolution micro-CT system based on rotational gantry and flat-panel detector for live mouse imaging. This system is composed primarily of an x-ray source with micro-focal spot size, a CMOS (complementary metal oxide semiconductor) flat panel detector coupled with Csl (TI) (thallium-doped cesium iodide) scintillator, a linearly moving couch, a rotational gantry coupled with positioning encoder, and a parallel processing system for image data. This system was designed to be of the gantry-rotation type which has several advantages in obtaining CT images of live mice, namely, the relative ease of minimizing the motion artifact of the mice and the capability of administering respiratory anesthesia during scanning. We evaluated the spatial resolution, image contrast, and uniformity of the CT system using CT phantoms. As the results, the spatial resolution of the system was approximately the 11.3 cycles/mm at 10% of the MTF curve, and the radiation dose to the mice was 81.5 mGy. The minimal resolving contrast was found to be less than 46 CT numbers on low-contrast phantom imaging test. We found that the image non-uniformity was approximately 70 CT numbers at a voxel size of ${\sim}55{\times}55{\times}X100\;{\mu}^3$. We present the image test results of the skull and lung, and body of the live mice.

  • PDF

Development of Physical Human Bronchial Tree Models from X-ray CT Images (X선 CT영상으로부터 인체의 기관지 모델의 개발)

  • Won, Chul-Ho;Ro, Chul-Kyun
    • Journal of Sensor Science and Technology
    • /
    • v.11 no.5
    • /
    • pp.263-272
    • /
    • 2002
  • In this paper, we investigate the potential for retrieval of morphometric data from three dimensional images of conducting bronchus obtained by X-ray Computerized Tomography (CT) and to explore the potential for the use of rapid prototype machine to produce physical hollow bronchus casts for mathematical modeling and experimental verification of particle deposition models. We segment the bronchus of lung by mathematical morphology method from obtained images by CT. The surface data representing volumetric bronchus data in three dimensions are converted to STL(streolithography) file and three dimensional solid model is created by using input STL file and rapid prototype machine. Two physical hollow cast models are created from the CT images of bronchial tree phantom and living human bronchus. We evaluate the usefulness of the rapid prototype model of bronchial tree by comparing diameters of the cross sectional area bronchus segments of the original CT images and the rapid prototyping-derived models imaged by X-ray CT.

Sequential CT Findings in Two Cases of Immunoglobulin G4-Related Lung Disease: Focused on Disease Progression (Immunoglobulin G4 관련 폐 질환의 질병 경과에 따른 순차적 CT 소견: 증례 보고)

  • Lee, Dong-Kyu;Ham, Soo-Youn
    • Journal of the Korean Society of Radiology
    • /
    • v.79 no.5
    • /
    • pp.276-281
    • /
    • 2018
  • Immunoglobulin G4 (IgG4)-related lung disease has been actively studied over the past few years. Radiologic findings of IgG4-related lung disease vary among patients, but there are no long-term follow up studies regarding variations in imaging features over the course of disease progression. In two cases with relatively long-term follow up, diverse early and late computed tomography (CT) findings of IgG4-related lung disease are reviewed in this report. In contrast to nodular or diffuse ground-glass opacity, which was predominantly noted in CT scans at earlier stages of disease, honeycombing and traction bronchiectasis were regarded as late radiologic manifestations. Solid nodules might be visible in both early and late stages; however, development of new solid nodules and enlargement of preexisting nodules could occur during disease progression. Interlobular septal thickening and mediastinal/hilar lymphadenopathy were persistent, even in later stages of the disease. These findings might be useful in making an accurate and timely diagnosis of IgG4-related lung disease.

Giant Intramyocardial Aneurysm in a Patient with Intercoronary Communication between the Left Circumflex Artery and Right Coronary Artery: A Case Report (우관상동맥과 좌회선지간 교통이 있는 환자에서 나타난 거대 심근내 동맥류: 증례 보고)

  • Yu Hyun Lee;Noh Hyuck Park;Ji Yeon Park;Seon-Jeong Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.1
    • /
    • pp.213-218
    • /
    • 2020
  • Coronary artery aneurysm is a rare disease. It occurs in the epicardial space, mostly along the course of major coronary arteries. Here, we report a case of a giant incidental aneurysm embedded in the basal posterior wall of the left ventricle. A 43-year-old woman was referred to our institution for the evaluation of cardiac palpitations that had been present from the previous 2 months. She reported no medical history (such as Kawasaki's disease or hypertension) or previous operative history. Echocardiogram and subsequent cardiac CT revealed a giant aneurysm in the left ventricle, with a direct fistulous connection to a dilated and tortuous left circumflex artery, which showed direct communication with the straight right coronary artery.

A Proposal of New Method for EICT Image Reconstruction A Hybrid Approach Using Genetic Algorithm and Newton-Raphson Method - (전기적 임피던스에 의한 컴퓨터 단층촬영 영상의 재구성의 위한 새로운 방법의 제안 - 유전알고리즘과 뉴으튼-랩슨법을 이용한 복합방법 -)

  • 조경호;고성택;고한석
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.4
    • /
    • pp.91-99
    • /
    • 1996
  • A hybrid approach employing both the genetic algorithm and the newton-raphson method is proposed for the electrical impedance computed tomography (EICT) image reconstruction. Computational experiments based on the new concept have shown promising results for several noise-free models. In particular, the resistance distribution of the tested models having resistivity ratio up to 100:1 has been reconstructed sucessfully. Using the proposed mehtod, it is also possible to get the reconstruction by the conventional iterative approaches be difficult to vonverge to a robust solution. If the compution power is enhanced further, the proposed method is expected to stimulate the practical applications of the EICT technology in the near future.

  • PDF

Radiographic and CT Diagnosis Of Otitis Media In a Dog (개에서 컴퓨터 단층촬영상을 통한 중이염의 진단)

  • 이기창;서은정;권정국;송경진;윤정희;최민철
    • Journal of Veterinary Clinics
    • /
    • v.21 no.2
    • /
    • pp.184-186
    • /
    • 2004
  • A castrated male, 6 year-old Shih-Tzu, weighing 4.6 kg with a discharge from the external ear canal and a mal-odor was referred to Verterinary Medical Teaching Hospital, Seoul National University. Radiographic findings were narrowing and focal loss of an air density in the left ear canal and bilateral thickening of the osseous bullae. For more detail examination, computed tomography was used. In computed tomographic findings, bilateral thickening of the bulla wall and increased opacity of the bulla space were observed. Thus this dog was diagnosed as bilateral otitis media. Then surgical correction, total ear canal ablation, was performed successfully and the patient showed a good prognosis thereafter. It is considered that computed tomography might serve as an useful imaging tool for otitis media and that it supplies information not obtained with a conventional radiography.

Development of Three-dimensional Tomography Technique for Analysis of Impinging Jet (충돌 제트 분석을 위한 3차원 토모그래피 기법 개발)

  • Kim Yong-Jae;Ahn Seong Soo;Ko Han Seo
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2004.11a
    • /
    • pp.34-35
    • /
    • 2004
  • Three dimensional density distributions of impinging and eccentric flames have been investigated by digital speckle tomography. The flames have been ignited by a mixture of butane and air from a circular nozzle and impinged against a plate located at the upper side of the burner exit. For comparison with experimental data, computer synthesized phantoms of impinging and eccentric flames have been reconstructed by a developed three-dimensional multiplicative algebraic reconstruction technique (MART). The advanced reconstruction in the stagnation flow region involved the sharp change of the flow direction and pressure gradient has been developed using a cross-correlation method and new scanning technique for the speckle displacement.

  • PDF