• Title/Summary/Keyword: 컴퓨터 단층촬영기

Search Result 7, Processing Time 0.011 seconds

Resolution Improvement of the Positron Computerized Tomography with a New Positron Camera Tomographic System (분해능 향상을 위한 새로운 양전자 단층 촬영기의 제안)

  • Hong, Ki-Sang;Ra, Jong-Beom
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.16 no.6
    • /
    • pp.22-30
    • /
    • 1979
  • A new circular ring position camera tomographic system termed "Oscillatory Dichotomic Ring" system is proposed and its performance is simulated. It is basically a circular ring system, composed of two half rings, which has the capability of scanning so that any sampling intervals can be obtained. Since finer sampling means poorer photon statistcs, simulations with varous signal dependent statistical noise effects, ray sampling and arrangement as well as related artifacts peculiar to the proposed Dichotomic Ring system are made.

  • PDF

An Experience Type Virtual Reality Training System for CT(Computerized Tomography) Operations (컴퓨터 단층 촬영기(CT)의 가상 실습을 위한 3차원 체험형 교육 시스템)

  • Shin, Yong-Min;Kim, Young-Ho;Kim, Byung-Ki
    • The KIPS Transactions:PartD
    • /
    • v.14D no.5
    • /
    • pp.501-508
    • /
    • 2007
  • Simulation system was introduced and used a lot in the fields of aviation, vessel, and medical treatment. 3D Simulation system has been used quite insufficiently as it requires a lot of system resource and huge amount of computer calculation. As the graphic card performance and simulation function developed, however, PC based simulation has been activated and is verified of its possibility as an educational software. However, educational institutions need to invest huge amount of budget and manpower to purchase and maintain CT Equipment. For such a reason, educational institutions entrust their students to hospitals for indirect experience of operation or for mere observation. This study, therefore, developed a CT Virtual reality education system with which medical CT Equipment can be directly operated in PC based 3D Virtual environment.

The Efficacy of Detecting a Sentinel Lymph Node through Positron Emission Tomography/Computed Tomography (근골격계 악성 종양 환자의 림프절 전이 발견을 위한 양전자 방출 컴퓨터 단층 촬영기(Positron Emission Tomography/Computed Tomography)의 유용성)

  • Shin, Duk-Seop;Na, Ho Dong;Park, Jae Woo
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.6
    • /
    • pp.509-518
    • /
    • 2019
  • Purpose: Lymph node metastasis is a very important prognostic factor for all skin cancers and some sarcomas. A sentinel lymph node (SLN) biopsy is the most useful technique for identifying SLNs. Recently, a new generation of diagnostic tools, such as single photon emission computed tomography/computed tomography (SPECT/CT) and positron emission tomography/CT (PET/CT) enabled the detection of SLNs. This study compared the efficacy of PET/CT for detecting lymph node metastases with a SLN biopsy in a single medical center. Materials and Methods: From 2008 to 2018, 72 skin cancers of sarcoma patients diagnosed with some lymph node involvement in a whole body PET/CT reading were assessed. Patients suspected of lymph node metastasis were sent to biopsy and those suspected to be reactive lesions were observed. The analysis was performed retrospectively using the medical records, clinical information, PET/CT readings, and pathology results. Results: The age of patients ranged from 14 to 88 years and the mean follow-up period was 2.4 years. Twenty-two patients were suspected of a lymph node metastasis and confirmed. The sensitivity, specificity, positive predictive value and negative predictive value of PET/CT images in sarcoma and non-sarcoma tumors were increased significantly when the expert's findings were considered together. Conclusion: PET/CT is effective in detecting lymph node metastases.

Acquisition of High Resolution Images and its Application using Synchrotron Radiation Imaging System (방사광 X-선을 이용한 고해상도 영상획득과 응용)

  • 홍순일;김희중;정해조;홍진오;정하규;김동욱;제정호;김보라;유형식
    • Progress in Medical Physics
    • /
    • v.12 no.1
    • /
    • pp.51-58
    • /
    • 2001
  • Synchrotron radiation (SR) has several advantages over convetional x-rays, including its phase, collimation, and high flux. A synchrotron radiation beamline 5C1 at Pohang Light Source (PLS) was recently built for imaging applications. We have shown that a SR imaging system is useful in imaging microscopic structures. SR with broad-band energy spectrum were adjusted to an object by Si wafers and their energy were approximately ranging from 6 keV to 30 keV. SR were passed through an object and finally transformed into visible lights by CdWO$_4$ scintillator screen. The visible lights which were reflected at an angle of 90 degrees by gold plated mirror were detected by a CCD camera and the image data were acquired using image acquisition system. A high-resolution phantom, capacitor, adult tooth, child tooth, cancerous breast tissue, and mouse lumbar vertebra were imaged with SR imaging system. The Objects were rotated within the field of view of the CCD detector, and their projection image data were obtained at 250 steps over 180 degrees rotation. Image reconstructions were carried out in a PC by using IDLTM(Research systems, Inc., US) program. The spatial resolution of the images acquired by the SR imaging system was measured with a high-resolution chart manufactured for several micrometer resolution. The specimens were also imaged with conventional x-ray radiography system to compare the image quality of radiography obtained with the SR imaging system. The results showed more structural details and high contrast images with SR imaging system than conventional x-ray radiography system. The SR imaging system may have a potential for imaging in biological researches, material applications, and clinical radiography.

  • PDF

Prognostic Value of Preoperative Positron Emission Tomography-Computed Tomography in Surgically Resected Stage I and II Non-Small Cell Lung Cancer (I, II병기 비소세포폐암의 예후에 대한 수술 전 양전자방출 컴퓨터 단층촬영기의 임상적 의의)

  • Song, Sung-Heon;Sohn, Jang-Won;Kwak, Hyun-Jung;Kim, Sa-Il;Kim, Sang-Heon;Kim, Tae-Hyung;Yoon, Ho-Joo;Shin, Dong-Ho;Choi, Yoon-Young;Park, Sung-Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.71 no.6
    • /
    • pp.425-430
    • /
    • 2011
  • Background: High 2-[$^{18}F$] fluoro-2-deoxy-D-glucose (FDG) uptake on positron emission tomography-computed tomography (PET-CT) is a prognostic factor for poor survival in non-small cell lung cancer (NSCLC), especially in Stage I. We determined whether the high FDG uptake value of a primary tumor was associated with recurrence and death in patients with resected Stage I and Stage II NSCLC. Methods: We identified consecutive patients who underwent complete surgical resection for Stage I and II NSCLC between 2006 and 2009, who had preoperative PET-CT, and reviewed clinical records retrospectively. FDG uptake was measured as the maximal standardized uptake value (SUVmax) for body weight. Patients were divided into two groups based on SUVmax: (i) above or (ii) below the cut-off value (SUVmax=5.9) determined by a receiver operating characteristic (ROC) curve. Results: Of 57 patients who were enrolled consecutively, 32 (56%) had Stage I NSCLC and 25 (44%) had Stage II. The 5-year recurrence-free survival (RFS) for patients with high (${\geq}5.9$) and low (<5.9) SUVmax were 31% and 57%, respectively (p=0.014). The 5-year overall survival (OS) rates were 39% and 60%, respectively (p=0.029). In univariate analyses, SUVmax (p=0.014), T staging (p=0.025), and differentiation of tumor tissue (p=0.034) were significantly associated with RFS. But, multivariate analyses did not show that SUVmax was an independently significant factor for RFS (p=0.180). Conclusion: High FDG uptake on PET-CT is not an independent prognostic factor for poor outcomes (disease recurrence in patients with resected Stage I and II NSCLC).

The Influence of Microwave Sintering Process on the Adaptation of CAD/CAM Zirconia Core (마이크로 웨이브 소결 과정이 CAD/CAM 지르코니아 코아의 적합도에 미치는 영향)

  • Kim, Keun Bae;Kim, Jee Hwan;Lee, Keun-Woo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.2
    • /
    • pp.95-107
    • /
    • 2009
  • The purpose of this research was to examine the fitness of zirconia cores that were made by different sintering methods; generic electricity furnace and microwave furnace. Firstly, 12 cores for each group were made by using each different sintering process and attached them to a metal die with silicon. The internal and marginal gap of sintered zirconia was measured by using Skyscan 1076 micro-CT, then it was reorganized by CT-An software. To each samples, we extracted B-L image, M-D image of cutting side, and cross-sectional side of tooth long axis and calculated the mean value of marginal, axial, and occlusal gap each side. Results: 1. The mean marginal gap of sintered zirconia was $36.20{\mu}m$ for EVE, $47.67{\mu}m$ for LAV, $52.47{\mu}m$ for DEN, and $54.63{\mu}m$ for CER. 2. For the axial wall, the research showed the largest value of $63.49{\mu}m$ for EVE, but there were no statistical significance. 3. In related to the occlusal internal measurement, DEN showed the smallest value ($77.06{\mu}m$), EVE and CER showed significantly high value. From this study, it is suggested that CAD/CAM zirconia core which was made in the process of microwave sintering has clinically acceptable values in marginal and internal gap.

Development of a Small Animal Positron Emission Tomography Using Dual-layer Phoswich Detector and Position Sensitive Photomultiplier Tube: Preliminary Results (두층 섬광결정과 위치민감형광전자증배관을 이용한 소동물 양전자방출단층촬영기 개발: 기초실험 결과)

  • Jeong, Myung-Hwan;Choi, Yong;Chung, Yong-Hyun;Song, Tae-Yong;Jung, Jin-Ho;Hong, Key-Jo;Min, Byung-Jun;Choe, Yearn-Seong;Lee, Kyung-Han;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.5
    • /
    • pp.338-343
    • /
    • 2004
  • Purpose: The purpose of this study was to develop a small animal PET using dual layer phoswich detector to minimize parallax error that degrades spatial resolution at the outer part of field-of-view (FOV). Materials and Methods: A simulation tool GATE (Geant4 Application for Tomographic Emission) was used to derive optimal parameters of small PET, and PET was developed employing the parameters. Lutetium Oxyorthosilicate (LSO) and Lutetium-Yttrium Aluminate-Perovskite(LuYAP) was used to construct dual layer phoswitch crystal. $8{\times}8$ arrays of LSO and LuYAP pixels, $2mm{\times}2mm{\times}8mm$ in size, were coupled to a 64-channel position sensitive photomultiplier tube. The system consisted of 16 detector modules arranged to one ring configuration (ring inner diameter 10 cm, FOV of 8 cm). The data from phoswich detector modules were fed into an ADC board in the data acquisition and preprocessing PC via sockets, decoder block, FPGA board, and bus board. These were linked to the master PC that stored the events data on hard disk. Results: In a preliminary test of the system, reconstructed images were obtained by using a pair of detectors and sensitivity and spatial resolution were measured. Spatial resolution was 2.3 mm FWHM and sensitivity was 10.9 $cps/{\mu}Ci$ at the center of FOV. Conclusion: The radioactivity distribution patterns were accurately represented in sinograms and images obtained by PET with a pair of detectors. These preliminary results indicate that it is promising to develop a high performance small animal PET.