• Title/Summary/Keyword: 커브 피팅

Search Result 52, Processing Time 0.036 seconds

Effects of Base Curve on Fitting with the current Soft Contact Lenses (베이스 커브에 의한 콘택트렌즈 피팅 효과)

  • Choe, Oh Mok;Gang, Myoung Jin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.2
    • /
    • pp.65-72
    • /
    • 2000
  • The study investigated the effects of base curve radius art the fit of thin, mid-water contact lenses. It was found that central corneal curvature(as measured with the keratometer) was not predictive of the best fitting base curve. Proper lens fit may be the single most important factor that ultimately determines the success of contact lens wear. Comfort, vision, and physiological response are all dependent on the fit of the lens. The percent of optimal fits was highest with the 8.4 mm base curve lens for all three ranges of keratometry values. When fit with the 8.4 mm lens. For most eyes, fitting a flatter lens led to greater decentration, decreased comfort, and no increase in lens movement. The 8.4 mm lens was found to provide on "optimal" fit in over 60% of eyes tested and a fit of "good" or "better" in nearly 90% of eyes tested. Comparisons of different manufactures' lens found that similiar lenses do not always fit in the same way due to subtle design and production differences. Therefore, different products may require different base curve radii to fit the same patient. This is even true when water content, center thickness, and diameter are approximately the same. A praditioner fitting a new patient in this lenses should begin with the 8.4 mm base curve radius.

  • PDF

Comparison of preference and Empirical Fit Success Rates for Spheric and Aspheric RGP Lenses (구면 및 비구면 디자인 RGP 콘택트렌즈의 선호도와 경험적 피팅 성공률 비교)

  • Kim, Jai-Min;Kim, Soo-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.2
    • /
    • pp.9-16
    • /
    • 2008
  • To assess the preference and efficacy of empirical fitting methods with spheric and aspheric RGP lenses. Methods: Healthy 37 subjects were fitted with spheric design (diameter 9.3 mm) on right eye and aspheric design (dia 9.6 mm) on the left eye. Base curves which were fitted empirically (using on-K, Kavg-0.50D (or 1.00D) and manufacturer's recommended fitting guide) were compared with another base curve which obtained the best diagnostic fit with spheric and aspheric RGP lenses. The preference and fitting type (lid attachment or interpalpebral) for two design lenses were investigated 2 weeks after fitting RGP lenses. Results: Of 33 successful RGP lens-wearing subjects, 76% preferred spheric design compared with 24% of aspheric RGP lens wearers. Sixty seven percent were fitted with lid-attachment in spheric lenses, whereas 64% were fitted with lid-attachment in aspheric lenses. The acceptable fit success rates within ${\pm}$0.50D of base curves were 97% for the on-K fit, 100% for the Kavg-0.50D fit and 100% of the manufacturer's guide fit compared with the diagnostic fit in spheric design, whereas 91%, 79% and 94% reported on-K, Kavg-1.00D and manufacturer's guide, respectively, in aspheric design. Conclusions: Although aspheric RGP lenses are more popular in the Korean market, it is still preferable to fit subjects with spheric RGP lenses. Empirical fitting may be best accomplished with the spheric lenses using Kavg-0.50D fit and the manufacturer's fitting guide, whereas aspheric RGP lens designs are unacceptable lens fit based on empirical fitting.

  • PDF

Influence of Base Curve on the Fit of Soft Contact Lenses (소프트 콘택트렌즈의 피팅에서 베이스커브의 영향)

  • Seong, Jeong-Sub;Kim, Jae-Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.3 no.1
    • /
    • pp.33-37
    • /
    • 1998
  • Lens centration was the fitting variable that was most dependent on base curve radius. Flatter lenses tended to decenter more. A flatter contact lens will likely have to move into the periphery to reach this point of stability. In most cases, the decentration was in the superior and/or temporal direction. It was also found that comfort complains were more common with flatter lenses. The optimal fits was highest with the 8.4mm base curve lens for all three ranges fit eyes decreased as base curve radius was increased. These lenses with steeper radii lead to better centration and therefore to better fit and comfort for more patients than do thin lenses with flatter radii.

  • PDF

Subjective Symptoms according to Fitting Test in Soft Contact Lens Wearers (소프트콘택트렌즈 착용자의 피팅 상태 확인 유무에 따른 자각적 증상)

  • Kim, Jung-Hee;An, Youngju
    • The Korean Journal of Vision Science
    • /
    • v.20 no.4
    • /
    • pp.431-442
    • /
    • 2018
  • Purpose : The purpose of this study was to investigate subjective symptoms according to the wearing, purchase and fitting status of soft contact lens wearers, and consumer perception of base curve. Methods : A survey was conducted for those who visited optical shops and lens shops in Seoul from June to August 2018. A total of 98 answer sheets they submitted were used for the analysis. The chi-square test and Fisher's exact test were used to compare subjective symptoms (dryness, glare, uncomfortable fitting, and decreased vision) according to whether fitting condition is screened (case history and push-up test, ect relevant to wearing sensation), and the odds ratio (OR) was obtained by the logistic regression analysis. Results : When the contact lenses were purchased, the rate of which the visual acuity test was performed was 86.6% at optical shop and 64.7% at lens shop. When purchasing contact lens and the contact lens was not tested for fitting, they more experienced dryness (OR 4.41, 95% CI 1.25-15.62) and uncomfortable fitting (OR 2.68, 95% CI 1.08-6.64) than testing for fitting. In addition, it was investigated that 87.8% of contact lens wearers did not know about the term base curve, 92.9% did not listen to an explanation related to the base curve when purchasing contact lenses, and 96.9% did not experience with base curve test. Conclusion : It would be thought that satisfaction of the contact lens fitting of existing consumers should be improved by changing a proper base curve by confirming the fitting condition when prescribing soft contact lens.

Additive Noise Reduction Algorithm for Mass Spectrum Analyzer (질량 스펙트럼 분석기를 위한 부가잡음제거 알고리즘)

  • Choi, Hun;Lee, Imgeun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.1
    • /
    • pp.33-39
    • /
    • 2018
  • An additive noise reduction algorithm for a mass spectrum analyzer is proposed. From the measured ion signal, we first used an estimated threshold from the mode of the measured signal to eliminate background noises with the white Gaussian characteristics. Also, a signal block corresponding to each mass index is constructed to perform a second order curve fitting and a linear approximation to signal block. In this process, the effective signal block composed of only the ion signal can be reconstructed by removing the impulsive noises and the sample signals which are insufficient to be viewed as normal ion signals. By performing curve fitting on the effective signal block, the noise-free mass spectrum can be obtained. To evaluate the performance of the proposed method, a simulation was performed using the signals acquired from the development equipment. Simulation results show the validity of the threshold setting from the mode and the superiority of the proposed curve fitting and linear approximation based noise canceling algorithm.

Study on The Suggested Curve Fitting Algorithm for Bolt Clamping Force Measurement (볼트 체결력 측정을 위해 제안한 커브피팅 알고리즘에 관한 연구)

  • Lee, Ki-Won
    • Journal of Satellite, Information and Communications
    • /
    • v.7 no.3
    • /
    • pp.94-98
    • /
    • 2012
  • In order to serve the exact torque clamping force, the torque measurement system use the curve fitting algorithm by the least square. The corrected least square curve fitting algorithm which suggested in this paper can surpport more exact clamping force for fastner in variable industry field using the torque. At first, This paper introduces mathematical modeling for curve fitting algorithm, and simulate it. As a result, the corrected least square algorithm have shown lower standard error value than that of the used algoritm with torque, and so this corrected least square algorithm prove high accuracy than nomal least square algorithm. The suggested algorithm will contribute to improvement of cost and safety on industry field with bolt clamping force for precision industry parts, electronics parts, aircraft, aerospace, etc.

Improvement of Spectrum Detection Algorithm for Mass Spectrometer (질량분석기를 위한 스펙트럼 검출 알고리즘의 개선)

  • Lee, Young Hawk;Choi, Hun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.1
    • /
    • pp.47-54
    • /
    • 2019
  • An improved method of spectrum detection algorithm for mass spectrum analysis system is proposed. In the conventional spectrum detection algorithm that utilizes the results of the linear approximation and quadratic curve fitting on the ion signal block of each mass index, it is possible to reduce the detection error in the mass spectrum detection by further improving the condition of eliminating the invalid ion signals. Also, the proposed method can reduce the estimation error of the peak value of the mass spectrum by using the result of quadratic curve fitting for the effective ion signal block in which the peak position error is corrected. To evaluate the effectiveness of the proposed method, computer simulations were carried out step by step using the measured ion signal. Also, by comparing the rate of false detection for several inputs, the proposed method showed better detection performance than the conventional method.

Fitting of Soft Contact Lenses (소프트 콘택트 렌즈의 피팅)

  • Lee, Eun-Hee;Kim, Dae-Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.1
    • /
    • pp.173-180
    • /
    • 2000
  • To determine the effect of base curve and diameter of soft contact lenses on the fitting under the various corneal curvature, the model eyes which was made of either stainless steel or ordinary wood, were used as the substitutes for human eyes. The evaluations of fit of the soft contact lenses on both wood model eyes and human eyes were found to be very similar to each other. All the contact lenses except very thin ones became flat after fit on the stainless steel model eyes because the model eye could not preserve enough moisture to hold the edge of contact lenses on the steel ball's surface. The relationships between the base curves of contact lenses and radii of cornea for the optimum (normal) fit were measured as follows : corneal curvature (C.C)<7.6 mm : base curve(B.C) 8.4 mm, C.C 7.6~7.8 mm : B.C 8.4~8.5 mm. C.C 7.8~8.1 mm : B.C 8.6 mm. It is concluded that larger base curve is required for the eyes which have abnormal bulge on its cornea. It is found that very thin soft contact lenses can be easily twisted or folded regardless of moisture content when they were fit on the relatively dry eyes(corneas).

  • PDF

Performance evaluation of Edge-based Method for classification of Gelatin Capsules (젤라틴 캡슐의 분류를 위한 에지 기반 방법 성능 평가)

  • Kwon, Ki-Hyeon;Choi, In-Soo
    • Journal of Digital Contents Society
    • /
    • v.18 no.1
    • /
    • pp.159-165
    • /
    • 2017
  • In order to solve problems in automatic quality inspection of tablet capsules, computation-efficient image processing technique, appropriate threshold setting, edge detection and segmentation methods are required. And since existing automatic system for quality inspection of tablet capsules is of very high cost, it needs to be reduced through the realization of low-price hardware system. This study suggests a technique that uses low-cost camera module to obtain image and inspects dents on tablet capsules and sorting them by applying TLS curve fitting technique and edge-based image segmentation. In order to assess the performance, the major classifications algorithm of PCA, ICA and SVM are used to evaluate training time, test time and accuracy for capsule image area and curve fitting edge data sets.

A Development of Prediction Model for Traffic Opening Time of Epoxy Asphalt Pavement Using Nonlinear Curve Fitting (비선형 커브피팅을 이용한 에폭시 아스팔트 포장의 교통개방 예측 모델 개발)

  • Jo, Shin Haeng;Kim, Nakseok
    • Journal of the Society of Disaster Information
    • /
    • v.9 no.3
    • /
    • pp.324-331
    • /
    • 2013
  • Epoxy asphalt concrete is used to reduce dead load and to increase durability on long-span steel bridge overlay. The strength development properties of epoxy asphalt concrete are affected by time and temperature because epoxy asphalt is two-phase reactive materials. The strength development of epoxy asphalt concrete should be predicted precisely to decide traffic opening time. Based on this background in mind, the prediction model for traffic opening time for epoxy asphalt pavement was proposed in this research. The developed model using nonlinear curve fitting revealed R2 value of 0.943 while the R2 value of the existing model using chemical kinetics was 0.806. An improved precise prediction result is to be obtained when the prediction model uses accurate temperature data of pavement.