• Title/Summary/Keyword: 카테터관련감염

Search Result 9, Processing Time 0.027 seconds

Imaging of Umbilical Venous Catheter-Related Hepatic Complications in Neonates (신생아의 제대 정맥 카테터와 관련된 간 합병증의 영상 소견)

  • Min Ju Kim;So-Young Yoo;Tae Yeon Jeon;Ji Hye Kim;Yu Jin Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.3
    • /
    • pp.586-595
    • /
    • 2023
  • An umbilical venous catheter (UVC) is commonly placed for central venous access in preterm or critically ill full-term neonates to provide total parenteral nutrition (TPN) and medication. However, UVCs can result in complications, including infection, portal vein thrombosis, and hepatic tissue injury. The inadvertent administration of hypertonic fluid through a malpositioned UVC can also cause hepatic parenchymal damage with mass-like fluid collection that simulates a tumorous condition during imaging. Ultrasonography and radiographic examinations play an essential role in detecting UVC-related complications. This pictorial essay aims to present the imaging findings of UVC-related hepatic complications in neonates.

Effects of a Short Message Service Intervention on Adherence to Maximal Sterile Barrier Precautions and Catheter-Related Blood Stream Infections (최대한의 멸균 차단법의 이행도와 중심정맥관 관련 혈류감염 발생에 대한 단문문자메시지 중재 효과)

  • Kang, Moon-Hee;Kim, Dong-Oak
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.18 no.2
    • /
    • pp.244-250
    • /
    • 2012
  • Purpose: The purpose of this study was to investigate the effect of a short message service intervention on adherence to maximal barrier precautions (MBP) and catheter-related blood stream infections. Method: The data were collected from March to September, 2008, at an 826-bed university-affiliated hospital in Daejeon. The study participants were 24 physicians who were inserting central catheters and 133 patients (control group 78 and intervention group 55) with central catheter insertions. The researcher sent the message (adherence to MBP and optimal recommendations) to each internal medicine doctor using the short message service (SMS) for cellular phones. Messages were sent monthly for 3 months. Data were analyzed by chi-square test and t-test using SPSS 12.0 windows program. Result: Adherence to maximal barrier precautions was significantly increased from 44.9% to 69.1% (p=.006) after the SMS intervention. But changes in the rate of CRBSI (catheter related blood stream infection) between the intervention group (1.89) and the control group (4.45) were not significant (p=.323). Conclusions: The results indicate that the SMS intervention is effective in increasing the adherence to maximal barrier precautions and the SMS intervention can be recommended for utilization in infection control nursing practice.

The Central Venous Catheter-related Infection of Chlorhexidine-silver Sulfadiazine Coated Catheters in Medical ICU (내과계 중환자실 환자에서 Chlorhexidine-silver Sulfadiazine Coated Catheter의 중심정맥관 감염에 대한 연구)

  • Jung, Young Ju;Koh, Younsuck;Lim, Chae-Man;Lee, Jae Seung;Yu, Mi Hyun;Oh, Yeon Mok;Shim, Tae Sun;Lee, Sang Do;Kim, Woo Sung;Kim, Dong Soon;Kim, Won Dong;Hong, Sang-Bum
    • Tuberculosis and Respiratory Diseases
    • /
    • v.59 no.4
    • /
    • pp.389-396
    • /
    • 2005
  • Background : Central venous catheters(CVCs) area major source of nosocomial infection. Chlorhexidine-silver sulfadiazine coated catheters (CHSS) were developed to reduce the rate of CVC infection. However, the clinical effectiveness of CHSS in comparison wth non-coated catheter (NCC) remains to be evaluated. Methods : From January 2004 to December 2004 in medical intensive care unit (ICU) of Asan Medical Center, CVCs were inserted in 446 cases. We retrospectively analyzed characteristics of patients and catheterization,the catheter-related infection rate and colonization, microbiologic findings, and insertion sites (subclavian, jugular, femoral) according to the type of inserted CVCs (NCC: 187 cases, CHSS: 259 cases). Catheter related infection is defined as catheter related bacteremia and catheter related non-bacteremic sepsis. Results : 1) The mean age of the patients in each group was $62{\pm}16$ years, $63{\pm}15$ years (p=0.42), and sex ratio 94:50, 141:69 (p=0.9) in NCC and CHSS. Duration of ICU admission ($29{\pm}37$, $26{\pm}44$ p=0.42), duration of mechanical ventilation ($17{\pm}22$, $15{\pm}19$ p=0.17), and APACHE III score at the time of CVC insertion ($81{\pm}34$, $82{\pm}37$ p=0.61) were not different between both groups. 2) Mean duration of catheterization was 118 in NCC and 119 in CHSS (p=0.98). Number of catheter-days was 2176 days in NCC and 3035 days in CHSS. Catheter-related infection occurred in 9 (4.8%) cases receiving NCC and 4 cases (1.5%) receiving CHSS. Catheterrelated infection incidence per 1000 catheter-days was 4.1 and 1.3, respectively (p=0.04). CHSS was associated with a significant reduction of infection in jugular catheters regarding to insertion sites (p=0.01). 3) Microorganisms causing infection were Staphylococcus aureus (n=3), Candida (n=3), coagulase-negative Staphylococci (n=2), and Klebsiella (n=1) in NCC, and Candida species (n=2), coagulase-negative Staphylococci (n=2), Proteus (n=1) in CHSS. Conclusion : CHSS has significantly reduced the episodes of infection compared to NCC in jugular catheterization in medical ICU.

Risk Factors of Catheter-related Bloodstream Infection Due to Methicillin-resistant Staphylococcus aureus in Very Low Birth Weight Infants (극소저체중 출생아에서 메티실린 내성 포도상구균으로 인한 카테터 연관 혈류감염의 위험인자)

  • Cho, Il-Hyun;Jung, Tae-Woong;Lee, Ju-Young;Moon, Se-Na;Bin, Joong-Hyun;Lee, Hyun-Seung;Lee, Jung-Hyun;Kim, So-Young;Sung, In-Kyung
    • Neonatal Medicine
    • /
    • v.18 no.2
    • /
    • pp.288-292
    • /
    • 2011
  • Purpose: The incidence of methicillin-resistant Staphylococcus aureus (MRSA) infection has increased in children and in neonates, and is particularly associated with frequent use of central venous catheter in very low birth weight (VLBW) infants. It is known that the morbidity and mortality of MRSA infection are low in neonates, as compared with adults. The objective of this study was to examine the difference in clinical characteristics between VLBW infants that survived and those that did not, a catheter-related bloodstream infection (CRBSI) of MRSA. Methods: Thirty-four VLBW infants had laboratory-confirmed bloodstream infection with S. aureus. We examined the incidence, mortality and morbidity of CRBSI, and predictive factors associated with mortality. Results: Twenty-six infants had same pathogen (24 MRSA, 2 Methicillin-sensitive Staphylococcus aureus) in the blood and in the catheter tip. Eight infants (25.8%) died in the CRBSI and they all had MRSA blood infections. Sex ratio, gestational age, duration between blood collection and identification of pathogens, and WBC and platelet count were not significantly different between patients that died from and patients that survived CRBSI of MRSA. C-reactive protein (CRP) was significantly higher in VLBW infants that died. Mean age of onset and hospital day was earlier (9.1${\pm}$6.6 vs. 26.9${\pm}$20.2; P=0.005) and shorter for patients that died (10.1${\pm}$7.0 vs. 73.0${\pm}$32.4; P=0.000). Two survivors had complications of pyogenic arthritis of the lower extremities and soft tissue infection, respectively. Conclusion: Mortality of CRBSI was likely to be high in VLBW infants and might be anticipated by CRP and early onset of disease.

Safety and Efficacy of Peripherally Inserted Central Catheters in Terminally Ill Cancer Patients: Single Institute Experience

  • Park, Kwonoh;Lim, Hyoung Gun;Hong, Ji Yeon;Song, Hunho
    • Journal of Hospice and Palliative Care
    • /
    • v.17 no.3
    • /
    • pp.179-184
    • /
    • 2014
  • Purpose: We investigated the safety and efficacy of peripherally inserted central catheters (PICCs) in terminally ill cancer patients. Methods: A retrospective review was conducted on patients who underwent PICC at the hospice-palliative division of KEPCO (Korea Electric Power Corporation) Medical Center between January 2013 and December 2013. All PICCs were inserted by an interventional radiologist. Results: A total of 30 terminally ill cancer patients received the PICC procedure during the study period. Including one patient who had had two PICC insertions during the period, we analyzed a total of 31 episodes of catheterization and 571 PICC days. The median catheter life span was 14.0 days (range, 1~90 days). In 25 cases, catheters were maintained until the intended time (discharge, transfer, or death), while they were removed prematurely in six other cases (19%; 10.5/1000 PICC days). Thus, the catheter maintenance success rate was 81%. Of those six premature PICC removal cases, self-removal due to delirium occurred in four cases (13%; 7.0/1000 PICC days), and catheter-related blood stream infection and thrombosis were reported in one case, each (3%; 1.8/1000 PICC days). Complication cases totaled eight (26%; 14.1/1000 PICC days). The time to complication development ranged from two to 14 days and the median was seven days. There was no PICC complication-related death. Conclusion: Considering characteristics of terminally ill cancer patients, such as a poor general condition, vulnerability to trivial damage, and a limited period of survival, PICC could be a safe intravenous procedure.

Analysis of Central Line-associated Bloodstream Infection among Infants in the Neonatal Intensive Care Unit: A Single Center Study

  • Kim, Minhye;Choi, Sujin;Jung, Young Hwa;Choi, Chang Won;Shin, Myoung-jin;Kim, Eu Suk;Lee, Hyunju
    • Pediatric Infection and Vaccine
    • /
    • v.28 no.3
    • /
    • pp.133-143
    • /
    • 2021
  • Purpose: This study aimed to determine the incidence of central line-associated bloodstream infection (CLABSI) in the neonatal intensive care unit (NICU), evaluate the patients' clinical characteristics, and identify the etiologic agents for guidance in prevention and treatment. Methods: A retrospective chart review study of infants classified as having CLABSI was conducted at the NICU of Seoul National University Bundang Hospital from January 2016 to December 2020. Results: Of the 45 infants, 53 had CLABSIs within a follow-up period of 18,622 catheter days. The incidence of CLABSIs was 2.85 per 1,000 catheter days. The most common catheter type was a peripherally inserted central catheter (n=47, 81%). A total of 57 pathogens were isolated, of which 57.9% (n=33) were Gram-positive bacteria, 36.8% (n=21) were Gram-negative bacteria, and 5.3% (n=3) were Candida spp. The most common pathogens were Staphylococcus aureus (n=12, 21%) and coagulase-negative staphylococci (n=12, 21%), followed by Klebsiella aerogenes (n=8, 14%). The median duration of bacteremia was 2 days, and 19 episodes showed bacteremia for 3 days or more. The mortality rate of infants within 14 days of CLABSI was 13.3% (n=6). Conclusions: This study analyzed the incidence of CLABSI and the distribution of pathogens in the NICU. Continuous monitoring of CLABSI based on active surveillance serves as guidance for empiric antibiotic use and also serves as a tool to assess the necessity for implementation of prevention strategies and their impact.

The Incidences of Catheter Colonization and Central Line-Associated Bloodstream Infection According to Tegaderm vs. Chlorhexidine Gluconate (CHG)-Tegaderm Dressing (중심정맥관 번들이행에 따른 중심정맥관 균집락과 중심정맥관 관련 혈류감염: CHG테가덤과 일반테가덤 드레싱비교연구)

  • Kim, Eunji;Lee, Haejung
    • Journal of Korean Academy of Nursing
    • /
    • v.50 no.4
    • /
    • pp.541-553
    • /
    • 2020
  • Purpose: In spite of the recent application of a general infection control method, central line-associated infections is still relatively high in Korea. Central line bundle with Chlorhexidine gluconate (CHG) tegaderm dressing was reported to be effective in reducing catheter colonization and central line-associated bloodstream infections (CLABSI). Therefore, this study aimed to examine the incidences of catheter colonization occurrence and CLABSI while using Tegaderm vs. CHG Tegaderm dressings. Methods: We used a descriptive design. 400 patients who had central venous catheters were selected from four hospitals in the Korean National Healthcare-associated Infections Surveillance System. Of all subjects, 200 used Tegaderm™ (Tegaderm group), and the remaining 200 used CHG Tegaderm (CHG Tegaderm group) dressing at the catheter insertion site. Data were analyzed using the χ2 test or Fisher's exact test, t-test, and logistic regression analysis using SPSS WIN 21.0. Results: In the Tegaderm and CHG Tegaderm groups, CLABSI incidences were 5.89 and 1.79 per 1,000 catheter-days, catheter colonization incidences were 3.93 and 1.43 per 1,000 catheter-days, and central line bundle compliance rates were 26.0% and 49.0%, respectively. Catheter colonization risk factors were 'reinsertion after failure' and 'Tegaderm dressing' at the central line insertion site. CLABSI risk factors were 'incomplete performance of 7 central line bundle items' and 'Tegaderm dressing' at the central line insertion site. Conclusion: A further prospective study is needed to examine the effects of central line bundle with CHG Tegaderm dressing, avoiding central line reinsertion after failure, and improving the bundle compliance in reducing catheter colonization and CLABSI.

The Analysis of Expression of Autoinducer Synthesis Genes Involved in Quorum Sensing among Catheter Associated Bacteria (요로감염에 관여하는 카테터 내 박테리아의 Quorum Sensing 관련 autoinducer 합성 유전자의 발현분석)

  • Lee, Mi-Hye;Seo, Pil-Soo;Lee, Ji-Youl;Peck, Kyong-Ran;Lee, Sang-Seob
    • Korean Journal of Microbiology
    • /
    • v.42 no.4
    • /
    • pp.277-285
    • /
    • 2006
  • The most biofilm forming bacteria in catheter, Esctherichia coli, Pseudomonas aeruginosa, and Staphylococcus aureus were isolated and identified from a patient's catheter occuring catheter-associated urinary tract infection (CA-UTI). We examined mRNA expression and its quantification of AIs synthetic genes encoding signal substance of quorum sensing from each bacterial species in order to elucidated quorum sensing mechanism. Both pure cultures for each bacterial strains and a mixed cultures with three were grown for 24 hr and 30 days. Initial densities to be able to detect mRNA expression oil single strains culture were shown at $2.4{\times}10^5$ CFU/ml, $5.4{\times}10^6$ CFU/ml of E. coli for ygaG and S. aureus for luxS, and at $6.9{\times}10^4$ CFU/ml of P. aeruginosa for rhlI and lasI. Also, in mixed culture of three, initial cell densities of mRNA expression were appear to at $7.3{\times}10^5$ CFU/ml, $1.6{\times}10^7$ CFU/ml of E. coli for ygaG and S. aureus for luxS, and at $2.1{\times}10^5$ CFU/ml of P. aeruginosa for rhlI and lasI. Each AIs synthetic gene was expressed in initial cell density and the mRNA expression of the genes were detected continously during 30 days. And then, the quantification of mRNA expression level of ygaG, rhlI, last, and luxS which were related AIs synthesis was done each time point by real-time RT-PCR. Interestingly, the mRNA levels of ygaG, rhlI, lasI, and luxS from the mixed culture was higher than those from each single strain culture. In the case of E. coli ygaG, the amount of transcript from the mixed culture was at least 30 times for that from single culture. In the case of P. aeruginosa rhlI and lasI, the amount of transcript from the mixed culture was at least 40 times and 250 times for that from single strain culture. In the case of S. aureus luxS, the amount of transcript from the mixed culture was at least 5 times for that from single strain culture. And specially, the mRNA expression of rhlI and lasI of P. aeruginosa showed the highest efficency among four AIs synthetic genes.

Systemic Candida Infection in Very Low Birth Weight Infants : Epidemiological Features Over 5 Years (극소 저체중 출생아에서 전신성 칸디다 감염 : 5년간의 역학적 특성)

  • Lee, Seung-Woo;Lee, Jeong-Eun;Lee, Ju-Young;Lee, Hyun-Seung;Lee, Jung-Hyun;Sung, In-Kyung
    • Neonatal Medicine
    • /
    • v.16 no.2
    • /
    • pp.190-196
    • /
    • 2009
  • Purpose: Candida infection has increased in neonatal intensive care units (NICU). However, recent reports on systemic candida infections in preterm newborns are rare in Korea. The aim of this study was to examine the epidemiological features of systemic candida infection in very low birth weight infants (VLBW) over the past five years. Methods: We retrospectively reviewed the medical records of 19 patients with systemic candida infections in VLBW that were admitted to the neonatal intensive care units of three hospitals affiliated with the College of Medicine, The Catholic University of Korea from January 2004 to December 2008. We analyzed the birth weight, gestational age, age at diagnosis, risk factors, co-morbidity, antifungal treatment, and mortality rates among the 19 patients. Results: Systemic candida infections occurred in 19 cases (4.7%) among the VLBW infants. The mean birth weight and gestational age were 959.0$\pm$255.9 g and 26.7$\pm$2.1 weeks. The isolated Candida species were C. albicans (4), C. parapsilosis (9), C. glabrata (2), C. famata (2), and unkown subspecies (2). Most patients had various associated risk factors, including a central venous catheter, broad spectrum antibiotics, parenteral nutrition, intravenous lipid emulsion, endotracheal intubation and $H_2$ blocker therapy. There was no significant difference in the risk factors between newborns that survived and those that died with regard to the systemic candida infection, except for gestational age. Nine (47.4%) out of 19 patients with a candida infection died and four cases (21.2%) were directly related to the candida infection. Conclusion: The prevalence of systemic candida infection is increasing in VLBW infants. The majority of Candida species has shifted to C. non-albicans, especially C. parapsilosis. Because of the high mortality associated with candida infection in the NICU, prophylaxis and early treatment based on epidemiological features is necessary.