• Title/Summary/Keyword: 치아 구조

Search Result 226, Processing Time 0.023 seconds

Flow Analysis of Vacuum Oral Cleaner Developed for Serious Patient (중증환자를 위한 진공 구강 세정기에 대한 유동해석)

  • Shin, Hyeon seok;Kim, Nam Woong;Kim, Kug Weon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.1
    • /
    • pp.121-126
    • /
    • 2018
  • The oral hygiene of patients admitted to the ICU (Intensive Care Unit) is very important. Critically ill patients are basically immunocompromised ones because of the high risk of infection by various pathogenic bacteria. The mouth is not only the primary site of infection, but also the site of systemic infections. The purpose of this study was to design a mouthpiece type vacuum oral cleaner for the oral care of seriously ill patients. A 3D CAD modeling and flow analysis model were established for a double structure type cleaner and standard tooth model, and their pressure and flow characteristics were analyzed. The pressure inside the oral cleaner was almost constant, but the velocity distribution showed a large difference between the inside and outside of the teeth. The velocity at the center region inside of the teeth was the highest, and the speed decreased as the distance from the center increased. In the analysis of the case where the suction tube was replaced by the drainage tube, the velocity at the center of the outer portion of the teeth was the highest. In order to increase the effectiveness of the oral cleaner, alternating between suction and drainage is proposed, and a design complement to increase the speed of the molar region is required.

Effect of Fluoridated 10% Carbamide Peroxide on Enamel Surface Change and Whitening (불소를 첨가한 10% Carbamide Peroxide의 법랑질표면 변화와 미백효과)

  • Lee, Hye-Jin;Kim, Hyun-Dae;Kim, Min-Young;Kwon, Tae-Yub;Kim, Kyo-Han
    • Journal of dental hygiene science
    • /
    • v.10 no.2
    • /
    • pp.95-100
    • /
    • 2010
  • The purposes of this study were to examine the effect of different fluoridated bleaching solution on the changes in physical and chemical characteristics of tooth. Forty-eight bovine incisors were divided into four groups to receive bleaching treatments, over a 14days period, as follows: no treatment; 10% carbamide peroxide (CP) bleaching; 10% CP containing 0.05% fluoride; and 10% CP containing 0.1% fluoride. All the specimens were highly polished and discolored with commercial COCK.Color and enamel changes were determined with colorimeter, microhardness tester, scanning electron microscope, atomic force microscopy. All the collected data were analyzed with one-way ANOVA. After the bleaching, bleached groups showed the color change(E*). Microhardness of 10% CP group decreased after tooth bleaching. But microhardness of containing fluoride bleached groups increased after tooth bleaching. Enamel surface of 10% CP bleached group showed any apparent morphology and roughness changes compared to the enamel which was stored in distilled water only. These results demonstrated that Fluoridated 10% Carbamide Peroxide have appreciable bleaching effect on bovine teeth and were not adversely affects enamel. Supporting influence of fluoride-containing bleaching solution on remineralization could be observed and further research must be carried out in various active environments to confirm these results clinically.

STRESS DISTRIBUTION OF ENDODONTICALLY TREATED MAXILLARY SECOND PREMOLARS RESTORED WITH DIFFERENT METHODS: THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS (상이한 방법으로 수복한 근관치료된 상악 제2소구치의 응력분포: 3차원 유한요소법적 분석)

  • Lim, Dong-Yeol;Kim, Hyeon-Cheol;Hur, Bock;Kim, Kwang-Hoon;Son, Kwon;Park, Jeong-Kil
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.1
    • /
    • pp.69-79
    • /
    • 2009
  • The purpose of this study was to evaluate the influence of elastic modulus of restorative materials and the number of interfaces of post and core systems on the stress distribution of three differently restored endodontically treated maxillary second premolars using 3D FE analysis. Model 1, 2 was restored with a stainless steel or glass fiber post and direct composite resin. A PFG or a sintered alumina crown was considered. Model 3 was restored by EndoCrown. An oblique 500 N was applied on the buccal (Load A) and palatal (Load B) cusp. The von Mises stresses in the coronal and root structure of each model were analyzed using ANSYS. The elastic modulus of the definitive restorations rather than the type of post and core system was the primary factor that influenced the stress distribution of endodontically treated maxillary premolars. The stress concentration at the coronal structure could be lowered through the use of definitive restoration of high elastic modulus. The stress concentration at the root structure could be lowered through the use of definitive restoration of low elastic modulus.

THE EFFECT OF LEUCONOSTOC LACTIS 51 AGAINST THE PLAQUE FORMATION OF STREPTOCOCCUS MUTANS (Streptococcus mutans의 치태형성에 대한 Leuconostoc lactis 51의 영향)

  • Kim, Tae-Geun;Yang, Kyu-Ho;Oh, Jong-Suk
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.27 no.4
    • /
    • pp.549-557
    • /
    • 2000
  • Dental caries is a bacterial disease of the dental hard tisssus, characterized by a localized, progressive, molecular disintegration of tooth structure. The action of Leuconostoc lactis 51 about plaque formation and replication by Streptococcus mutans was studied as follows. 1. Lower amount of plaque was produced at the mixed culture of S. mutans and L. lactis 51 than S. mutans alone on the wires in the beaker. 2. Fewer cells of S. mutans were replicated at the mixed culture of S. mutans and L. lactis 51 than S. mutans alone. 3. In M17Y broth, viable cells of S. mutans and L. lactis 51 increased for 12 hours, and decreased for 24 hours. In M17YS broth, viable cells of S. mutans showed time-dependent decrease at mixed culture of S. mutans and L. lactis 51. 4. The culture supernatant of L. lactis 51 didn't inhibit the replication of S. mutans and the formation of artificial plaque. 5. Sucrose and frutose were extracted from the culture supernatant of L. lactis 51 in M17YS broth. These results suggest that L. lactis 51 isolated from the oral cavity inhibits the replication of S. mutans and the formation of artificial plaque.

  • PDF

Computer-aided design and manufacturing-based full mouth rehabilitation for a patient with excessive attrition and restricted vertical dimension: A case report (심한 치아 마모와 수복 공간 부족을 보이는 환자에서 CAD/CAM 기술을 활용한 완전 구강 회복: 증례 보고)

  • Cho, Jun-Ho;Yoon, Hyung-In;Yeo, In-Sung;Han, Jung-Suk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.4
    • /
    • pp.495-505
    • /
    • 2019
  • This study reported the treatment of a patient with excessive worn dentition and limited maxillo-mandibular space for restoration, utilizing the computer-aided design and computer-aided manufacturing (CAD/CAM) technology. After the thorough examination of the patient's occlusal vertical dimension (OVD), full mouth rehabilitation was planned with increase of the OVD. The patient was satisfied with the provisional restorations establishing the increased OVD. The horizontal and vertical data of the patient's jaw relation that the provisional restorations contained were transferred to the definitive metal ceramic fixed prostheses by double scanning and three-dimensional printing. After the fixed restorations were cemented to the abutments, electronic surveying and three-dimensional printing were used to fabricate metal frameworks for the patient's removable partial dentures. The mandibular definitive removable prostheses were delivered to the patient's mouth and the full mouth rehabilitation procedures were completed. The digital technologies used for this case produced fixed and removable restorations satisfactory in masticatory, phonetic and aesthetic functions to both the patient and the dental clinician.

IMMOBILIZATION OF LOWER MANDIBULAR ALVEOLAR BONE FRACTURE USING RESIN-WIRE OPEN CAP SPLINT (하악 유전치부 치조골 골절시 resin-wire open cap splint를 이용한 고정)

  • Kwon, Joung-Hyun;Choi, Byung-Jai;Choi, Hyung-Jun;Kim, Seong-Oh;Son, Heung-Kyu;Lee, Jae-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.1
    • /
    • pp.175-180
    • /
    • 2008
  • Traumatic injuries to the primary dentition are commonly encountered problems in dental practice. It is found that 30% of the children had injuries to the primary dentition and 22% to the permanent dentition. The greatest incidence of trauma to the primary dentition occurs at the ages of 2 and 3 as children start to learn motor coordination. Because teeth and alveolar bone are traumatized simultaneously, alveolar bone fractures are likely to occur when multiple teeth are involved in injuries. Dental splints are indicated for the management of maxillofacial fractures. They enable anatomic reduction of fractured segments and help immobilization and maintenance of the fragments after reduction. They also act as a stabilizer during rehabilitation. Various types of dental splints are available. In this case, routine resin-wire splint technique could not be applied because of the child's uncooperative behavior. Oral sedation was not indicated because N.P.O. had not been preceded. Therefore, we decided to use open-cap acrylic splint instead. Stabilization using open cap acrylic splint requires minimum chair time with reduced discomfort to both patient and dentist. It is an effective means of splint for uncooperative children and especially useful when other means of fixation have been failed. Because trauma on the primary dentition can affect the underlying permanent tooth germ, it is important to monitor eruption process of the permanent dentition.

  • PDF

The Effect of an Interocclusal Appliance on Head and Neck Posture (교합장치물이 두경부 자세에 미치는 영향)

  • Eun-Ha Kim;Keum-Back Shin;Ik-Jun Lim
    • Journal of Oral Medicine and Pain
    • /
    • v.19 no.2
    • /
    • pp.81-97
    • /
    • 1994
  • 두개하악장애는 환자의 신체적 소인, 관련조직의 구조적 변화, 정신적 스트레스 등의 복합적 요인에 의 발생하는 다인성 질환으로 최근 대두되는 원인중의 하나가 신체, 특히 두경부의 자세이상이다. 비정상적인 두경부자세는 하악의 위치변화를 수반하여 종종 두개하악장애를 야기시키게 되나 이를 설명할 수 있는 과학적 증거는 아직 부족한 실정이다. 저자는 두경부 자세가 교합장치물에 의해 변화되는지를 저작근의 근전도학적 측면에서 규명하고자 21세에서 26세의 치과대학생으로 치아상실 및 교합간섭이 없고 두 개하악장애의 증후 및 경부운동제한을 가지지 않은 정상인 20명을 대상으로 각도계를 사용하여 시상면상에서 인위적으로 유도한 세 가지의 두경부자세변화 (0$^{\circ}$, 30$^{\circ}$ 굴절, 45$^{\circ}$ 신전)에 따른 교합안정장치의 장착(1시 간) 전후 및 안정위와 근접촉위(초기치아접촉위)에서의 두경부 근육(측두근, 교근, 악이복근)의 근전도를 Bioelectric Microprocessor EM2ⓡ를 사용하여 측정한 후 통계학적으로 비교, 분석, 평가하여 다음과 같은 결과를 얻었다. 1. 교합안정장치 장착전 하악 안정위 및 근접촉위에서 두부의 30$^{\circ}$굴절은 악이복근의 근활성도를, 45$^{\circ}$신전은 교근 및 악이복근의 근활성도를 증가시켰다.(p<0.05) 2. 교합안정장치 장착후 하악 안정위에서 두부의 30$^{\circ}$굴절은 악이복근의 근활성도를, 45$^{\circ}$신전은 교근 및 악이복근의 근활성도를 증가시켰으며, 하악 근접촉위에서 두부의 45$^{\circ}$신전은 악이복근의 근활성도를 증가시켰다(p<0.05). 3. 교합안정장치 장착 전후 및 두부의 30$^{\circ}$굴절, 45$^{\circ}$신전에 따른 측두군 및 교근의 하악 근접촉위에서의 근활성도가 안정위에서의 근활성도에 비해 유의한 증가를 나타냈다(p<0.05).

  • PDF

Full mouth rehabilitation of a severely worn dentition using intraoral scanner and the CAD/CAM double scanning technique (중증도의 치아 마모 환자를 구내 스캐너와 이중스캔을 이용해 수복한 완전구강회복 증례)

  • Yoon, Se-Na;Han, Jung-Suk;Yeo, In-Sung;Yoon, Hyung-In
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.1
    • /
    • pp.67-76
    • /
    • 2020
  • With the evolution of the computer-aided design/computer-aided manufacturing (CAD/CAM) technology, the intraoral scanners are playing an increasingly important role, as they are the first step towards a completely digital workflow. The CAD/CAM double scanning technique has been used to transfer the information from provisional restorations to definitive restorations. In this case, a 67-year-old male with esthetically compromised anterior teeth, generalized severe attrition of teeth, and reduced vertical dimension was treated with full mouth rehabilitation including a re-establishment of the lost vertical dimension of occlusion assisted by the crown lengthening procedure. The provisional restorations were fabricated using an intraoral scanner and the CAD/CAM double scanning technique. After the period of adaption, the definitive monolithic zirconia restorations were delivered. The CAD/CAM double scanning technique successfully transferred the occlusal and morphological characteristics, obtained from the provisional restorations, to the definitive restorations.

MANAGEMENT OF DENS EVAGINATUS IN PREMOLAR (소구치에 발생한 치외치의 치험례)

  • Ra, Eun-Sun;Kim, Jong-Soo;Kwon, Soon-Won
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.1
    • /
    • pp.110-115
    • /
    • 2003
  • Dens evaginatus is an anomalous tooth development arising during morphodifferentiation. It is most often reported in premolar, and familial occurrence has been reported. The primary dental complication of dens evaginatus is fracture or wear of the tubercle which leads to pulp exposure, pulpal necrosis and periapical infection. Pathosis of the pulp can occur before complete root formation with cessation of root development. A rational and conservative approach to the management of dens evaginatus in vital teeth includes early diagnosis and treatment to prevent fracture or attrition of the tubercle. This treatment would include careful sequential grinding, pulp capping, preventive resin restoration. When presented with a case of dens evaginatus in a nonvital tooth with incomplete root development, the treatment of choice has been extraction, apexification. We report two cases of dens evaginatus that appear in two sisters. In the elder, a periapical lesion on radiographs is shown, and it is treated by calcium hydroxide apexification. The other sister is early recognized of dens evaginatus, it is treated using glass ionomer cement reinforcing with sequential grinding.

  • PDF

Induction Heating Device for Dental Implant Removal (인공치아의 임플란트 탈착을 위한 유도가열장치 연구)

  • Lee, Sang-Myung;Seo, Young;Song, Chang-Woo;Lee, Seung-Yop
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.5
    • /
    • pp.305-311
    • /
    • 2016
  • Induction heating is the process in which an electrically conducting object (usually a metal) is heated by electromagnetic induction through heat generated in the object by eddy currents. The main advantage of an induction heating device is the generation of the heat inside the target object itself. Hence, non-contact and safe heating devices are widely used in many industrial and medical fields. Recently, a new dental implant system was developed using a shape-memory alloy, wherein an artificial tooth could be easily removed from the dental implant by heating. This paper discusses the development of an induction-heating device to remove the dental crown in the new implant system. First, the finite element simulation of electromagnetic and thermal coupling analysis was implemented to obtain the temperature distributions of the target object for various frequencies, input currents, and coil shapes. Based on the simulation results, experiments were conducted by using prototypes, and an induction heating device was developed to remove the dental crown from the implant.