• Title/Summary/Keyword: 치료 선량 확인

Search Result 510, Processing Time 0.029 seconds

Lymph Node Failure Pattern and Treatment Results of Esophageal Cancer Patients Treated with Definitive Radiotherapy (근치목적 방사선치료를 받은 식도암 환자의 림프절 재발양상과 치료성적)

  • Lee, Sun-Young;Kwon, Hyoung-Cheol;Lee, Heui-Hwan;Kim, Jung-Soo;Kim, Soo-Geon
    • Radiation Oncology Journal
    • /
    • v.26 no.2
    • /
    • pp.77-82
    • /
    • 2008
  • Purpose: We evaluated the failure pattern of the celiac axis, gastric lymph node, and treatment outcome in the upper and mid-esophageal region of cancer patients treated by definitive radiotherapy, except when treating the celiac axis and gastric lymph node for treatment volume, retrospectively. Materials and Methods: The study constituted the evaluation 108 patients with locally advanced esophageal cancer receiving radiotherapy or a combination of radiotherapy and chemotherapy at Chonbuk National University Hospital from January 1986 to December 2006. In total, 82 patients treated by planned radiotherapy, except when treating the celiac axis and gastric lymph node for treatment volume, were analysed retrospectively. The study population consisted of 78 men and 2 women(mean age of 63.2 years). In addition, 51 patients received radiotherapy alone, whereas 31 patients received a combination of radiation therapy and chemotherapy. The primary cancer sites were located in the upper portion(17 patients), and mid portion(65 patients), respectively. Further, the patients were in various clinical stages including T1N0-1M0(7 patients), T2N0-1M0(18 patients), T3N0-1M0(44 patients) and T4N0-1M0(13 patients). The mean follow up period was 15 months. Results: The various treatment outcomes included complete response(48 patients), partial response(31 patients) and no response(3 patients). The failure patterns of the lymph node were comprised of the regional lymph node(23 patients) and the distance lymph node which included celiac axis and gastric lymph node(13 patients). However, metastasis was not observed in the regional and distant lymph node in 10 patients, whereas 36 patients were not evaluated. Furthermore, of the 13 patients who developed celiac axis and gastric lymph node metastases, 3 were in stage T1N0-1M0 and 10 were in stage T2-4N0-1M0. A complete response appeared in 12 patients, whereas a partial response appeared in 1 patient. The mean survival time of the patients who appeared for regional and distant lymph node metastasis was 14.4 and 7.0 months, respectively. Conclusion: In locally advanced esophageal cancer patients, who were treated by definitive radiotherapy without celiac axis and gastric lymph node irradiation, the distant lymph node metastasis rate was high and the overall survival rate was lower compared to the regional lymph node metastasis. The incidence of regional and distant lymph node metastasis was high in patients who appeared beyond clinical stage T2 and received radiotherapy alone.

Statistical Analysis of Operating Efficiency and Failures of a Medical Linear Accelerator for Ten Years (선형가속기의 10년간 가동률과 고장률에 관한 통계분석)

  • Ju Sang Gyu;Huh Seung Jae;Han Youngyih;Seo Jeong Min;Kim Won Kyou;Kim Tae Jong;Shin Eun Hyuk;Park Ju Young;Yeo Inhwan J.;Choi David R.;Ahn Yong Chan;Park Won;Lim Do Hoon
    • Radiation Oncology Journal
    • /
    • v.23 no.3
    • /
    • pp.186-193
    • /
    • 2005
  • Purpose: To improve the management of a medical linear accelerator, the records of operational failures of a Varian CL2l00C over a ten year period were retrospectively analyzed. Materials and Methods: The failures were classified according to the involved functional subunits, with each class rated Into one of three levels depending on the operational conditions. The relationships between the failure rate and working ratio and between the failure rate and outside temperature were investigated. In addition, the average life time of the main part and the operating efficiency over the last 4 years were analyzed. Results: Among the recorded failures (total 587 failures), the most frequent failure was observed in the parts related with the collimation system, including the monitor chamber, which accounted for $20\%$ of all failures. With regard to the operational conditions, 2nd level of failures, which temporally interrupted treatments, were the most frequent. Third level of failures, which interrupted treatment for more than several hours, were mostly caused by the accelerating subunit. The number of failures was increased with number of treatments and operating time. The average life-times of the Klystron and Thyratron became shorter as the working ratio increased, and were 42 and $83\%$ of the expected values, respectively. The operating efficiency was maintained at $95\%$ or higher, but this value slightly decreased. There was no significant correlation between the number of failures and the outside temperature. Conclusion: The maintenance of detailed equipment problems and failures records over a long period of time can provide good knowledge of equipment function as well as the capability of predicting future failure. Wore rigorous equipment maintenance Is required for old medical linear accelerators for the advanced avoidance of serious failure and to improve the qualify of patient treatment.

Evaluation on the Accuracy of Targeting Error Correction Through the Application of Target Locating System in Robotic CyberKnife (로봇 사이버나이프에서 위치인식시스템을 이용한 Targeting Error값 보정의 정확성 평가)

  • Jeong, Young-Joon;Jung, Jae-Hong;Lim, Kwang-Chae;Cho, Eun-Ju
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.1
    • /
    • pp.1-7
    • /
    • 2009
  • Purpose: The purpose is to evaluate the accuracy of correcting the targeting error through the Target Location System (TLS) for the location change error of the reference point which arises from the movement or motion of patient during the treatment using the CyberKnife. Materials and Methods: In this test, Gafchromic MD-55 film was inserted into the head and neck phantom to analyze the accuracy of the targeting, and then the 6 MV X-ray of CyberKnife (CyberKnife Robotic Radiosurgery System G4, Accuray, US) was irradiated. End to End (E2E) program was used to analyze the accuracy of targeting, which is provided by Accuray Corporation. To compute the error of the targeting, the test was carried out with the films that were irradiated 12 times by maintaining the distance within the rage of $0{\pm}0.2\;mm$ toward x, y, z from the reference point and maintaining the angle within the rage of $0{\pm}0.2^{\circ}$ toward roll, pitch, yaw, and then with the films which were irradiated 6 times by applying intentional movement. And the correlation in the average value of the reference film and the test film were analyzed through independent samples t-test. In addition, the consistency of dose distribution through gamma-index method (dose difference: 3%) was quantified, compared, and analyzed by varying the distance to agreement (DTA) to 1 mm, 1.5 mm, 2 mm, respectively. Results: E2E test result indicated that the average error of the reference film was 0.405 mm and the standard deviation was 0.069 mm. The average error of the test film was 0.413 mm with the standard deviation of 0.121 mm. The result of independent sampling t-test for both averages showed that the significant probability was P=0.836 (confidence level: 95%). Besides, by comparing the consistency of dose distribution of DTA through 1 mm, 1.5 mm, 2 mm, it was found that the average dose distribution of axial film was 95.04%, 97.56%, 98.13%, respectively in 3,314 locations of the reference film, consistent with the average dose distribution of sagittal film that was 95.47%, 97.68%, 98.47%, respectively. By comparing with the test film, it was found that the average dose distribution of axial film was 96.38%, 97.57%, 98.04%, respectively, at 3,323 locations, consistent with the average dose distribution of sagittal film which was 95.50%, 97.87%, 98.36%, respectively. Conclusion: Robotic CyberKnife traces and complements in real time the error in the location change of the reference point caused by the motion or movement of patient during the treatment and provides the accuracy with the consistency of over 95% dose distribution and the targeting error below 1 mm.

  • PDF

Preliminary Study for Imaging of Therapy Region from Boron Neutron Capture Therapy (붕소 중성자 포획 치료에서 치료 영역 영상화를 위한 예비 연구)

  • Jung, Joo-Young;Yoon, Do-Kun;Han, Seong-Min;Jang, HongSeok;Suh, Tae Suk
    • Progress in Medical Physics
    • /
    • v.25 no.3
    • /
    • pp.151-156
    • /
    • 2014
  • The purpose of this study was to confirm the feasibility of imaging of therapy region from the boron neutron capture therapy (BNCT) using the measurement of the prompt gamma ray depending on the neutron flux. Through the Monte Carlo simulation, we performed the verification of physical phenomena from the BNCT; (1) the effects of neutron according to the existence of boron uptake region (BUR), (2) the internal and external measurement of prompt gamma ray dose, (3) the energy spectrum by the prompt gamma ray. All simulation results were deducted using the Monte Carlo n-particle extended (MCNPX, Ver.2.6.0, Los Alamos National Laboratory, Los Alamos, NM, USA) simulation tool. The virtual water phantom, thermal neutron source, and BURs were simulated using the MCNPX. The energy of the thermal neutron source was defined as below 1 eV with 2,000,000 n/sec flux. The prompt gamma ray was measured with the direction of beam path in the water phantom. The detector material was defined as the lutetium-yttrium oxyorthosilicate (Lu0,6Y1,4Si0,5:Ce; LYSO) scintillator with lead shielding for the collimation. The BUR's height was 5 cm with the 28 frames (bin: 0.18 cm) for the dose calculation. The neutron flux was decreased dramatically at the shallow region of BUR. In addition, the dose of prompt gamma ray was confirmed at the 9 cm depth from water surface, which is the start point of the BUR. In the energy spectrum, the prompt gamma ray peak of the 478 keV was appeared clearly with full width at half maximum (FWHM) of the 41 keV (energy resolution: 8.5%). In conclusion, the therapy region can be monitored by the gamma camera and single photon emission computed tomography (SPECT) using the measurement of the prompt gamma ray during the BNCT.

The reliability of the cephalogram generated from cone-beam CT (Cone-beam CT로부터 제작된 측모 두부계측방사선사진의 정확도 평가)

  • Kang, Ji-Young;Kim, Kwang-Won;Lim, Sung-Hoon
    • The korean journal of orthodontics
    • /
    • v.37 no.6
    • /
    • pp.391-399
    • /
    • 2007
  • Three-dimensional approaches for the diagnosis and analysis of the dentofacial area are becoming more popular in accordance with the development of cone-beam CT (CBCT). The purposes of this study were to evaluate the reliability of cephalometric measurements of lateral cephalograms generated from a CBCT image by making comparisons with the traditional digital lateral cephalogram, and to evaluate the possibility of the clinical application of CBCT generated cephalogram images. Methods: Twenty patients whose external auditory meatus could be identified in the CBCT image were selected, and both CBCT and digital cephalograms were taken. Differences between the measurements of both cephalograms were tested by paired t-test. Results: Among the 22 measurements used, only U1-FH, Mx6 to PTV, and maxillomandibular difference showed statistically significant differences between the CBCT generated cephalogram and the digital cephalogram. Conclusions: The results suggest that the CBCT generated cephalogram can be used for some cephalometric measurements not requiring porion, PTV, condylion as a landmark (SNA, SNB, U1 to SN, IMPA, interincisal angle, etc.).

Results of Concurrent Chemoradiotherapy and Intraluminal Brachytherapy in Esophageal Carcinoma - Retrospective Analysis with Respect to Survival - (식도암에서 동시 항암화학방사선요법과 관내근접치료의 결과 -생존율을 중심으로 한 후향적 분석-)

  • Nam Taek-Keun;Nah Byung-Sik;Chung Woong-Ki;Ahn Sung-Ja;Song Ju-Young
    • Radiation Oncology Journal
    • /
    • v.22 no.1
    • /
    • pp.25-32
    • /
    • 2004
  • Purpose : Evaluate the efficacies and toxicities of concurrent chemoradiotherapy (CCRT), with or without intraluminal brachytherapy (ILB), using a retrospective analysis in esophageal carcinomas with respect to survival. Materials and Methods : From April 1995 to July 2001, a total of 65 patients, diagnosed with an esophageal carcinoma, were treated by CCRT, with 21 also treated by ILB after CCRT. External radiotherapy was peformed using 6 or 10 MV X-rays, with a dose range of $46.8~\69.6$ Gy (median; 59.4). The ILB was peformed using high-dose-rate brachytherapy with Ir-192. The fractionation of ILB was 3 Gy by 4, or 5 Gy by 2 fractions. Cisplatin $(75\;mg/m^2)$ was given on each first day of weeks 1, 5, 9 and 13, and 5-FU $(1,000\;mg/m^2)$ as a continuous infusion for the first 4 days of each course. Results : The median survival time of all patients was 15 months, and the 1, 2 and 3-year survival rates were 55.4, 29.2 and $20.7\%$, respectively. The 2-year survival rates of the patients with and without ILB were 33.3 and $27.3\%$, respectively (p=0.80). The 2-year survival rates of the patients with a complete, partial and no response were 44.1, 13.8 and $0\%$, respectively (p=0.02). The response to treatment was the only significant factor affecting the overall survival from a multivariate analysis. Conclusion : This study has shown that the survival outcomes of CCRT were much better than previous results with radiotherapy alone. However, the addition of ILB after CCRT showed no advantage over that of CCRT alone.

Evaluation of Usability Both Oblique Verification for Inserted Fiducial Marker of Prostate Cancer Patients (Fiducial Marker가 삽입된 전립선암 환자를 대상으로 한 양사방향 촬영의 유용성 평가)

  • Kim, Koon Joo;Lee, Jung Jin;Kim, Sung Gi;Lim, Hyun Sil;Kim, Wan Sun;Kang, Su Man
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.123-129
    • /
    • 2013
  • Purpose: The way check the movement of the fiducial marker insertion in the treatment of patients with prostate cancer. However the existing methods of fiducial marker verification process difficult to identify the specific location of the marker behind the femur and pelvic bone. So to study the evaluation of maker match with using kilo voltage (KV) X-ray by On-board imager to both oblique verification method. Materials and Methods: Five patients were selected for rectal ballooning and inserted fiducial marker. Compare the position of the fiducial marker of reference plan 2D/2D Anterior/Posterior verification method and 2D/2D both oblique verification method. So to measurement the shift score of X, Y, Z (axis) and measure exposure dose given to patients and compare matching time. Results: 2 dimensional OBI KV X-ray imaging using two-dimensional matching image are orthogonal, so locating fiducial marker matching clear and useful DRR (digital reconstruction radiography) OBI souce angle ($45^{\circ}/315^{\circ}$) matching most useful. 2D/2D both oblique verification method was able to see clearly marker behind the pelvic bone. Also matching time can be reduced accordingly. According to the method of each matching results for each patient in each treatment fraction, X, Y, and Z axis the Mean $value{\pm}SD$ (standard deviation) is X axis (AP/LAT: $0.4{\pm}1.67$, OBLIQUE: $0.4{\pm}1.82$) mm, Y axis (AP/LAT: $0.7{\pm}1.73$, OBLIQUE: $0.2{\pm}1.77$) mm, Z axis (AP/LAT: $0.8{\pm}1.94$, OBLIQUE:$1.5{\pm}2.8$) mm. In addition, the KV X-ray source dose radiation exposure given to the patient taking average when AP/LAT matching is (0.1/2.1) cGY, when $315^{\circ}/45^{\circ}$ matching is (0.27/0.26) cGY. Conclusion: In conclusion for inserted fiducial marker of prostate cancer patients 2D/2D both oblique matching method is more accurate verification than 2D/2D AP/LAT matching method. Also the matching time less than the 2D/2D AP/LAT matching method. Taken as the amount of radiation exposure to patients less than was possible. Suggest would improve the treatment quality of care patients more useful to establish a protocol such as case.

  • PDF

Short-Term Results of Non-Small Cell Lung Cancer with Curative Radiotherapy (비소세포성 폐암의 방사선 치료 성적)

  • Ahn Sung Ja;Park Seung Jin;Chung Woong Ki;Nah Byung Sik
    • Radiation Oncology Journal
    • /
    • v.8 no.2
    • /
    • pp.213-218
    • /
    • 1990
  • A retrospective analysis was performed or 102 patients with non-small cell lung cancer who received the curative radiotherapy from August 1985 to October 1988 at the Department of Therapeutic Radiology of Chonnam University Hospital. The follow-up period was ranged from 1 to 37 months and the median follow-up time was 15 months. The acturial 1 and 2 year survival rate of all the patients was $28\%\;and\;5\%$, respectively. The median survival was 10 months for stage II, 6 months for stage IIIA, and 9 for IIIB and the actuarial 2 year survival tate was $12.5\%,\;12.1\%,\;and\;0\%$ respectively. The treatment failure was identified in 32 patients and the locoregional failure was seen in 9 patients ($28\%$) and the distant failure in 23 patients ($72\%$). The initial performance status was related to the survival with statistical significance (p<0.01), but the survival difference by the radiation dose was not statistically significant (p>0.05).

  • PDF

Biological Activities of Extracts from Gamma-irradiated Aralia elata Cortex (감마선 조사한 총목피(Aralia elata Cortex) 추출물의 생리활성)

  • Park, Hye-Jin;Lee, Eun-Ho;Kim, Myung-Uk;Lee, Seon-Ho;An, Dong-Hyun;An, Bong-Jeun;Kwon, Joong-Ho;Cho, Young-Je
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.43 no.8
    • /
    • pp.1236-1247
    • /
    • 2014
  • Gamma irradiated-treatment of natural medicinal plants can be used to improve extraction transference number and for qualitative improvement of color when applied to functional material exploration. This study investigated the biological activities of Aralia elata cortex extracts upon gamma irradiation. In addition, different physical techniques [photostimulated luminescence (PSL) and thermoluminescence (TL)] were used for irradiation identification of Aralia elata cortex. In PSL analysis, non-irradiated (0 kGy) sample showed a negative result of 400 photon counts (PCs), whereas irradiated (5, 10, and 30 kGy) samples showed positive results of 90,100.00, 312,614.33, and 321,661.67 PCs, respectively. In the TL method, growth curve showed very unusual behaviors around $200^{\circ}C$ upon natural-irradiation of the non-irradiated (0 kGy) sample and around $150{\sim}250^{\circ}C$ for the irradiated (5, 10, and 30 kGy) samples. The TL ratio was 0.1 in non-irradiated samples at 0.011, whereas the values of irradiated samples (5, 10, and 30 kGy) were 0.1 at 1.105, 1.009, and 2.206, respectively. For phenolics of gamma-irradiated Aralia elata cortex, water and 50% ethanol extracts had the highest amounts, $17.30{\pm}0.40mg/g$ and $18.87{\pm}0.46mg/g$ at 10 kGy irradiation, respectively. The inhibitory activities of angiotensin-converting enzyme and xanthin oxidase were higher in both irradiated water and 50% ethanol extracts than in non-irradiated ones. For pancreatin ${\alpha}$-amylase and ${\alpha}$-glucosidase inhibitory activities, water and 50% ethanol extracts containing $200{\mu}g/mL$ of phenolics showed high inhibitory activities of 60~100% at all irradiation doses (0~30 kGy). This result confirmed that Aralia elata cortex extracts have greater anti-diabetic effects than acabose as a diabetic remedy. Gamma-irradiated Aralia elata cortex extracts are useful as a functional material with anti-diabetic effects. Thus, Aralia elata cortex extracts can be used as a functional material with various biological activities, and gamma-irradiation can be used to amplify biological activities in plants.

Preoperative Radiotherapy of Maxillary Sinus Cancer (상악동암에서 수술 전 방사선 치료의 효과)

  • Kim, Jae-Chul;Park, In-Kyu
    • Radiation Oncology Journal
    • /
    • v.16 no.3
    • /
    • pp.259-264
    • /
    • 1998
  • Purpose : This study was to evaluate the effectiveness of preoperative radiotherapy in maxillary sinus cancer. Materials and Methods : A retrospective analysis was done for 42 patients with maxillary sinus cancer who were treated with radiation with or without surgery from April 1986 to September 1996. There were 27 male and 15 female patients. Patients' age ranged from 24 to 75 years (median 56 years). Stage distribution showed 2 in T2, 19 in T3, and 21 in T4 lesions The histologic type was squamous cell carcinoma in 38, undifferentiated carcinoma in 1, transitional cell carcinoma in 1, and adenoid cystic carcinoma in 2 patients. All patients were treated with radiation initially with a dosage range of 50.4-70.2 Gy (median 70.2 Gy) before further evaluation of remnant disease. Eleven patients were given induction chemotherapy (2cycles of 5-fluorouracil and cisplatin) concurrently with radiotherapy. Six to eight weeks after radiotherapy with or without chemotherapy computerized tomography (CT) of paranasal sinus was taken to evaluate remnant disease. If the CT finding showed remnant disease, a Caldwell-Luc procedure was done to get the specimen of suspicious lesions. A radical maxillectomy was done if the specimen was proven to contain malignancy. In contrast periodic follow-up examination was done without any radical surgery if the tissue showed only granulation tissue. Follow-up period ranged from 3 to 92 months with a median 16 months. Results : Nine (21.4$\%$) patients showed complete response (CR) and 33 patients (78.6$\%$) showed persistent disease (PER) to initial radiotherapy. Among the 9 CR patients, 7 patients had no evidence of disease (NED), 1 patient had local failure, and 1 patient had regional failure. Among 33 PER patients, salvage total maxillectomy was done in 10 patients, and the surgery was not feasible or refused in 23 patients. Following the salvage radical surgery, 2 patients were NED and 8 patients were PER status. Overall and disease- free survival rate at 5 years was 23.1$\%$ and 16.7$\%$, respectively. The only factors associated with the overall survival rate was the response to radiotherapy (P<0.01). Conclusion : The only factors associated with the overall survival rate was the response to radiotherapy. We could omit a radical mutilating surgery by preoperative irradiation in 7 of 42 patients (21.4$\%$) so as to preserve their facial integrity.

  • PDF