• Title/Summary/Keyword: 치과보조원

Search Result 13, Processing Time 0.019 seconds

Convergence analysis of safety management for radiation workers and diagnostic radiation-generator devices of animal hospital in Korea (국내 동물병원의 진단용 방사선 발생장치 및 방사선 관계종사자 안전관리에 관한 융복합적 분석)

  • Kang, Kyoung-Mook;Suh, Tae-Young;Kim, Yong-Sang;Yun, Seon-Jong
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.4
    • /
    • pp.55-61
    • /
    • 2020
  • The various types of radiation-generator devices have been used in animal hospitals, and the safety for radiation workers is becoming important in Korea. This study investigated and analyzed the radiation safety management for diagnostic radiation-generator devices and radiation workers of animal hospital. The number of radiation-generator devices and radiation workers of animal hospital increased from 2,138 to 2,972 and from 2,644 and 5,733 for six years. The number of general X-ray, CT, C-arm, portable and dental X-ray in 2019 were 2,204, 58, 67, 770, and 14. The number of veterinarian, veterinary nurse, veterinary assistant, and others in 2019 were 4,236, 1,080, 404, and 13. The average exposure dose of radiation workers in 2018 were 0.21mSv in surface dose, 0.18mSv in depth doses. This study is expected to be the basic data for the safety management of radiation-generating devices and radiation workers in animal hospital.

Removable implant-supported partial denture using milled bar with Locator® attachments in a cleft lip & palate patient: A clinical report (구순구개열 환자에서 Locator® 유지장치가 장착된 milled titanium bar를 이용한 가철성 임플란트 피개 국소의치의 보철수복증례)

  • Yang, Sang-Hyun;Kim, Kyoung-A;Kim, Ja-Yeong;Seo, Jae-Min
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.3
    • /
    • pp.207-214
    • /
    • 2015
  • Due to the limitations of conventional removable partial denture prostheses to treat a cleft lip & palate patient who shows scar tissue on upper lip, excessive absorption of the maxillary residual alveolar ridge, and class III malocclusion with narrow palate and undergrowth of the maxilla, 4 implants were placed on the maxillary edentulous region and a maxillary removable implant-supported partial denture was planned using a CAD/CAM milled titanium bar. Unlike metal or gold casting technique which has shrinkage after the molding, CAD/CAM milled titanium bar is highly-precise, economical and lightweight. In practice, however, it is very hard to obtain accurate friction-fit from the milled bar and reduction in retention can occur due to repetitive insertion and removal of the denture. Various auxiliary retention systems (e.g. $ERA^{(R)}$, $CEKA^{(R)}$, magnetics, $Locator^{(R)}$ attachment), in order to deal with these problems, can be used to obtain additional retention, cost-effectiveness and ease of replacement. Out of diverse auxiliary attachments, $Locator^{(R)}$ has characteristics that are dual retentive, minimal in vertical height and convenient of attachment replacement. Drill and tapping method is simple and the replacement of the metal female part of $Locator^{(R)}$ attachment is convenient. In this case, the $Locator^{(R)}$ attachment is connected to the milled titanium bar fabricated by CAD/CAM, using the drill and tapping technique. Afterward, screw holes were formed and 3 $Locator^{(R)}$ attachments were secured with 20 Ncm holding force for additional retention. Following this procedure, satisfactory results were obtained in terms of aesthetic facial form, masticatory function and denture retention, and I hereby report this case.

Study on Development in Professional Work of Radiological Technologists (방사선사 업무의 발전에 관한 조사 연구)

  • Choi, Jong-Hak;Kim, Chang-Kyun;Kim, Won-Chul;Kim, Seung-Chul
    • Journal of radiological science and technology
    • /
    • v.29 no.3
    • /
    • pp.197-210
    • /
    • 2006
  • This study explored several agenda related to license system, education, professional work of radiological technologists(RTs) and a transition process of law for them to investigate a developmental strategy of RTs as a professional career. The results are as followings : 1. The national license system for RTs was started from 1965, 1965-1972 x-ray technicians(medical assistance), 1973-present(2006) radiotechnologist(medical technologist) since then. 2. The average pass ratio of national license examination(1965-2006) for RTs was 46.6%. The method, subjects and level of the examination should be improved. 3. The education term for RTs has been changed since 1963 ; 1963-1990 two year college, 1991-1999 three year college, 2000-2006 four year and three year college depending on universities and colleges. As of 2006, there are twelve 4-year universities and eighteen 3-year colleges. The total number of new students were 1,956. 4. The new developmental paradigm should be made for technology education of RTs corresponding to the development of medicine and science. 5. The qualification system of clinical specialists in radio-technology field needs to be operated not by the non-governmental body(The Korean Radiological Technologists Association) but by the governmental body. 6. The vertical relationship among RTs, doctors and other medical workers should be rebuilt through the revision of law. Especially, doctors and dentists 'guidance authority' for RTs should be changed to 'request authority'. 7. The service extent of RTs should be extended in medical fields corresponding to professional work of RTs and a revision of the law needed for this situation.

  • PDF