Efficacy and Accuracy of Patient Specific Customize Bolus Using a 3-Dimensional Printer for Electron Beam Therapy (전자선 빔 치료 시 삼차원프린터를 이용하여 제작한 환자맞춤형 볼루스의 유용성 및 선량 정확도 평가)

  • Choi, Woo Keun;Chun, Jun Chul;Ju, Sang Gyu;Min, Byung Jun;Park, Su Yeon;Nam, Hee Rim;Hong, Chae-Seon;Kim, MinKyu;Koo, Bum Yong;Lim, Do Hoon
    • Progress in Medical Physics
    • /
    • v.27 no.2
    • /
    • pp.64-71
    • /
    • 2016
  • We develop a manufacture procedure for the production of a patient specific customized bolus (PSCB) using a 3D printer (3DP). The dosimetric accuracy of the 3D-PSCB is evaluated for electron beam therapy. In order to cover the required planning target volume (PTV), we select the proper electron beam energy and the field size through initial dose calculation using a treatment planning system. The PSCB is delineated based on the initial dose distribution. The dose calculation is repeated after applying the PSCB. We iteratively fine-tune the PSCB shape until the plan quality is sufficient to meet the required clinical criteria. Then the contour data of the PSCB is transferred to an in-house conversion software through the DICOMRT protocol. This contour data is converted into the 3DP data format, STereoLithography data format and then printed using a 3DP. Two virtual patients, having concave and convex shapes, were generated with a virtual PTV and an organ at risk (OAR). Then, two corresponding electron treatment plans with and without a PSCB were generated to evaluate the dosimetric effect of the PSCB. The dosimetric characteristics and dose volume histograms for the PTV and OAR are compared in both plans. Film dosimetry is performed to verify the dosimetric accuracy of the 3D-PSCB. The calculated planar dose distribution is compared to that measured using film dosimetry taken from the beam central axis. We compare the percent depth dose curve and gamma analysis (the dose difference is 3%, and the distance to agreement is 3 mm) results. No significant difference in the PTV dose is observed in the plan with the PSCB compared to that without the PSCB. The maximum, minimum, and mean doses of the OAR in the plan with the PSCB were significantly reduced by 9.7%, 36.6%, and 28.3%, respectively, compared to those in the plan without the PSCB. By applying the PSCB, the OAR volumes receiving 90% and 80% of the prescribed dose were reduced from $14.40cm^3$ to $0.1cm^3$ and from $42.6cm^3$ to $3.7cm^3$, respectively, in comparison to that without using the PSCB. The gamma pass rates of the concave and convex plans were 95% and 98%, respectively. A new procedure of the fabrication of a PSCB is developed using a 3DP. We confirm the usefulness and dosimetric accuracy of the 3D-PSCB for the clinical use. Thus, rapidly advancing 3DP technology is able to ease and expand clinical implementation of the PSCB.

An Analysis on the Conditions for Successful Economic Sanctions on North Korea : Focusing on the Maritime Aspects of Economic Sanctions (대북경제제재의 효과성과 미래 발전 방향에 대한 고찰: 해상대북제재를 중심으로)

  • Kim, Sang-Hoon
    • Strategy21
    • /
    • s.46
    • /
    • pp.239-276
    • /
    • 2020
  • The failure of early economic sanctions aimed at hurting the overall economies of targeted states called for a more sophisticated design of economic sanctions. This paved way for the advent of 'smart sanctions,' which target the supporters of the regime instead of the public mass. Despite controversies over the effectiveness of economic sanctions as a coercive tool to change the behavior of a targeted state, the transformation from 'comprehensive sanctions' to 'smart sanctions' is gaining the status of a legitimate method to impose punishment on states that do not conform to international norms, the nonproliferation of weapons of mass destruction in this particular context of the paper. The five permanent members of the United Nations Security Council proved that it can come to an accord on imposing economic sanctions over adopting resolutions on waging military war with targeted states. The North Korean nuclear issue has been the biggest security threat to countries in the region, even for China out of fear that further developments of nuclear weapons in North Korea might lead to a 'domino-effect,' leading to nuclear proliferation in the Northeast Asia region. Economic sanctions had been adopted by the UNSC as early as 2006 after the first North Korean nuclear test and has continually strengthened sanctions measures at each stage of North Korean weapons development. While dubious of the effectiveness of early sanctions on North Korea, recent sanctions that limit North Korea's exports of coal and imports of oil seem to have an impact on the regime, inducing Kim Jong-un to commit to peaceful talks since 2018. The purpose of this paper is to add a variable to the factors determining the success of economic sanctions on North Korea: preventing North Korea's evasion efforts by conducting illegal transshipments at sea. I first analyze the cause of recent success in the economic sanctions that led Kim Jong-un to engage in talks and add the maritime element to the argument. There are three conditions for the success of the sanctions regime, and they are: (1) smart sanctions, targeting commodities and support groups (elites) vital to regime survival., (2) China's faithful participation in the sanctions regime, and finally, (3) preventing North Korea's maritime evasion efforts.

Facile [11C]PIB Synthesis Using an On-cartridge Methylation and Purification Showed Higher Specific Activity than Conventional Method Using Loop and High Performance Liquid Chromatography Purification (Loop와 HPLC Purification 방법보다 더 높은 비방사능을 보여주는 카트리지 Methylation과 Purification을 이용한 손쉬운 [ 11C]PIB 합성)

  • Lee, Yong-Seok;Cho, Yong-Hyun;Lee, Hong-Jae;Lee, Yun-Sang;Jeong, Jae Min
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.2
    • /
    • pp.67-73
    • /
    • 2018
  • $[^{11}C]PIB$ synthesis has been performed by a loop-methylation and HPLC purification in our lab. However, this method is time-consuming and requires complicated systems. Thus, we developed an on-cartridge method which simplified the synthetic procedure and reduced time greatly by removing HPLC purification step. We compared 6 different cartridges and evaluated the $[^{11}C]PIB$ production yields and specific activities. $[^{11}C]MeOTf$ was synthesized by using TRACERlab FXC Pro and was transferred into the cartridge by blowing with helium gas for 3 min. To remove byproducts and impurities, cartridges were washed out by 20 mL of 30% EtOH in 0.5 M $NaH_2PO_4$ solution (pH 5.1) and 10 mL of distilled water. And then, $[^{11}C]PIB$ was eluted by 5 mL of 30% EtOH in 0.5 M $NaH_2PO_4$ into the collecting vial containing 10 mL saline. Among the 6 cartridges, only tC18 environmental cartridge could remove impurities and byproducts from $[^{11}C]PIB$ completely and showed higher specific activity than traditional HPLC purification method. This method took only 8 ~ 9 min from methylation to formulation. For the tC18 environmental cartridge and conventional HPLC loop methods, the radiochemical yields were $12.3{\pm}2.2%$ and $13.9{\pm}4.4%$, respectively, and the molar activities were $420.6{\pm}20.4GBq/{\mu}mol$ (n=3) and $78.7{\pm}39.7GBq/{\mu}mol$ (n=41), respectively. We successfully developed a facile on-cartridge methylation method for $[^{11}C]PIB$ synthesis which enabled the procedure more simple and rapid, and showed higher molar radio-activity than HPLC purification method.

Packing effects on the intracavitary radiation Therapy 3-Dimension plan of the uterine cervix cancer (자궁경부암 강내조사 3차원 치료계획 시 Packing의 유용성 분석)

  • Si, Chang-Keun;Jo, Jung-Kun;Lee, Du-Hyun;Kim, Sun-Yeung;Kim, Tae-Yoon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.1
    • /
    • pp.1-8
    • /
    • 2005
  • Purpose : An effect of a packing to uterine treatment of a cervical cancer using a dose-volume histogram for a point dose and a volume dose of the bladder and the rectum was analyzed by establishing a three-dimensional treatment plan using a CT image. Materials and methods : Reference points of the bladder and the rectum were marked, respectively at a treatment plan device (plato brachytherapy V14.2.4) by photographing CT(marconi, USA) when the packing was used and removed under the same condition and a treatment plan was performed to Apoint depending on ICRU38. However, in case of the rectum, a maximum point was looked up and compared with the above point because the point presented from the ICRU is not proper as a representative value of a rectum point dose. Further, the volume dose depending on volume of $50\%,\;80\%,\;and\;100\%$ point doses of the rectum and the bladder was measured. The measured values were used to analyze the effect of the packing through a Wilcoxon Signed Rank Test (a SAS statistical analysis process program). Result : The reference points at the bladder and rectum doses when the packing was removed were $116.94\;35.42\%$ and $117.59\;21.08\%$, respectively. The points when the packing was used were $107.08\;38.12\%$ and $95.19\;21.32\%$, respectively. After the packing was used, the reference points at the bladder and the rectum were decreased by $9.86\%$ and $22.4\%$, respectively. When the packing was removed, the maximum points at the bladder and the rectum were $164.51\;50.89\%,\;128.81\;33.05\%$, respectively. When the packing was used, the maximum points at the bladder and the rectum were $142.31\;44.79,\;110.08\;37.03\%$, respectively. After the packing was used, the maximum points at the bladder and the rectum were decreased by $22.2\%$ and $18.73\%$, respectively. When the packing was removed, the bladder volume at $50\%,\;80\%,\;and\;100\%$ point doses of the rectum and the bladder were $48.62{\pm}18.09\%,\;16.12{\pm}11.15\%,\;and\;7.51{\pm}6.63\%$, respectively and its rectum volume were $23.41{\pm}14.44\%,\;6.27{\pm}4.28\%,\;2.79{\pm}2.27\%$, respectively. When the packing was used, the bladder volume at $50\%,\;80\%,\;and\;100\%$ point doses of the rectum and the bladder were $40.33{\pm}16.72,\;11.63{\pm}8.72,\;and\;4.87{\pm}4.75\%$, respectively and its rectum volume were $18.96{\pm}8.37\%,\;4.75{\pm}2.58\%,\;and\;1.58{\pm}1.06\%$, respectively. After the packing was used, the bladder volume at $50\%,\;80\%,\;and\;100\%$ point doses of the rectum and the bladder were decreased by $8.29\%,\;4.49\%,\;and\;2.64\%$, respectively and its bladder volume were decreased by $4.45\%,\;1.52\%,\;and\;1.21\%$, respectively. Conclusion : Values at Reference point doses of the bladder and the rectum recommended from the ICRU 38 were 0.0781 and 0.0781, respectively and values of their maximum point doses were 0.0156 and 0.0156, respectively, as a result of which an effect of the packing using at the uterine intracavitary treatment of an uterine cervical cancer through the three-dimensional treatment plan used CT were measured. That is, the values at reference point doses and the values at maximum point doses show similar difference. However, P value was 0.15 at over $50\%,\;80\%,\;and\;100\%$ volume doses and the value shows no similar difference. In other words, the effect of the packing looks like having a difference at the point dose, but actually shows no difference at the volume dose. The reason is that the volume of the bladder and the rectum are wide but the volume of the packing is only a portion. Therefore, the effect of decreasing the point dose was not great. Further, the farer the distance is, the more weak the intensity of radiation is because the intensity of radiation is proportional to inverse square of a distance. Therefore, the effort to minimize an obstacle of the bladder and the rectum by using the packing should be made.