• Title/Summary/Keyword: 측정의 정확성

Search Result 1,290, Processing Time 0.033 seconds

Predicting Calcium and Phosphorus Concentrations in Imported Hay by near Infrared Reflectance Spectroscopy (근적외선분광법을 이용한 수입건초의 Ca과 P 함량 예측)

  • Lee, Bae Hun;Kim, Ji Hye;Oh, Mirae;Lee, Ki Won;Park, Hyung Soo
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.41 no.1
    • /
    • pp.29-34
    • /
    • 2021
  • Near infrared reflectance spectroscopy (NIRS) is routinely used for the determination of nutrient components of forages. However, little is known about the impact of sample preparation and wavelength on the accuracy of the calibration to predict minerals. This study was conducted to assess the effect of sample preparation and wavelength of near infrared spectrum for the improvement of calibration and prediction accuracy of Calcium (Ca) and Phosphorus (P) in imported hay using NIRS. The samples were scanned in reflectance in a monochromator instrument (680-2,500 nm). Calibration models (n = 126) were developed using partial least squares regression (PLS) based on cross-validation. The optimum calibrations were selected based on the highest coefficients of determination in cross validation (R2) and the lowest standard error of cross-validation (SECV). The highest R2 and the lowest SECV were obtained using oven-dry grinded sample preparation and 1,100-2,500 nm wavelength. The calibration (R2) and SECV were 0.99 (SECV: 468.6) for Ca and 0.91 (SECV: 224.7) for P in mg/kg DM on a dry weight, respectively. Results of this experiment showed the possibility of NIRS method to predict mineral (Ca and P) concentration of imported hay in Korea for routine analysis method to evaluate the feed value.

Work factor system에 기초한 MODAPTS의 정확성 분석과 "high task MODAPTS"의 동작시간 설정에 관한 연구

  • 박성학
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 1992.04b
    • /
    • pp.559-568
    • /
    • 1992
  • MODAPTS는 1966년 호주에서 MTM을 기초로 하여 개발되었으며, 이 시스템은 학습과 사용이 용이해서 널리 사용되고 있다. 그러나 본 논문의 연구결과, MODAPTS의 시간단위는 동작구간의 쇠대치를 기준으로 하고 MTM의 동작시간을 합성하여 설정된 것이 증명되었으며, MTM의 동작시간은 "낮은 과업 표준(Low Task Standard)"을 기준으로 하였기 때문에 MODAPTS는 그 정확성에 대하여 검증을 필요로 한다. 본 논문에서는 "높은 과업 표준(High Task Standard)"을 기준으로 하여 설정된 WF를 기초로 하여 MODAPTS의 구성과 정확성에 대하여 분석하였으며, "High Task MODAPTS"의 동작시간을 설정하였다. "High Task MODAPTS"(약칭 HITMAP)는 WF에 대한 정확도가 95%이상으로서 성과급용 표준시간 설정에 충분하므로 생산활동의 생산성을 측정하고 개선하는데 이바지할 것으로 기대된다.하므로 생산활동의 생산성을 측정하고 개선하는데 이바지할 것으로 기대된다.

Communication Overhead Analysis for Improving Reliability in Distributed Real-Time Systems (분산 실시간 시스템에서 신뢰성 향상을 위한 통신 부하 분석)

  • Goo Hyun-Woo;Hong Young-Sik
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2005.07a
    • /
    • pp.769-771
    • /
    • 2005
  • 실시간 시스템은 논리적 정확성뿐만 아니라 시간적 정할성을 요구한다. 시간적 정확성을 만족시키기 위해 실시간 시스템의 설계자는 작업들의 스케줄 가능성에 대한 연구를 선행해야만 한다. 그리고 스케줄 가능성 분석을 위해 프로그램들에 대한 실행 시간 예측이 필요하다. 작업들의 실행 시간 예측을 위한 방법으로 측정과 정적 분석이 연구되었다. 측정 및 정적 분석은 비용 핀 확장성에 문제점을 지니고 있고 실시간 시스템의 발전을 따라가지 못하여 분석 결과의 정확성 밀 신뢰성이 만족스럽지 못하다. 본 논문에서는 정적 분석을 단일 실시간 시스템이 아닌 분산 실시간 시스템에 적용할 수 있는 확장된 정적 분석 도구의 개발에 초점을 둔다. 먼저 확장된 정적 분석 도구의 개발을 위해 통신 영향 요소의 분석 과정을 설계한다. 특히, 통신 부하의 영향 요소 중 통신 준비에 필요한 과정을 선행 예측 테이블로 작성하여 원시 프로그램 분석에 이용하고자 한다. 실행 시간에 영향을 미치는 요소들의 분석을 통해 원시 프로그램에서 자동적으로 예측된 실행 시간의 정확도와 신뢰도를 높인다.

  • PDF

Efficiency Evaluation of CT Simulator QA Phantom (전산화 단층촬영 모의치료기 정도관리 팬텀의 유용성 평가)

  • Hwang, Se-Ha;Min, Je-Sun;Lee, Jae-Hee;Park, Heung-Deuk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.2
    • /
    • pp.89-95
    • /
    • 2009
  • Purpose: The purpose is to evaluate efficiency of the CT simulator QA phantom manufactured for daily QA. Materials and Methods: We made holes ($1{\times}100{\times}1\;mm$) to verify accuracy between image and real measurement in polystyrene phantom and made 1 mm holes to verify table movement accuracy at superior and inferior 100 mm to the center of the phantom and inserted radiopacity material. To evaluate laser alignment, we made cross mark on the right and left side at phantom and to evaluate CT number accuracy we made 3 cylindrical holes and inserted equivalence material of bone, water, air in them. After CT scanning the phantom, We evaluated accuracy between image and real measurement, accuracy of table movement, laser, and CT number using exposed image. Results: It was measured that the accuracy between image and real measurement was ${\pm}0.3\;mm$, table movement accuracy was ${\pm}0.3\;mm$, laser accuracy was ${\pm}0.5\;mm$ from 7th January to 7th March in 2008 as within the reference point ${\pm}1\;mm$. In the CT number accuracy of bone was ${\pm}10\;HU$, air was ${\pm}5\;HU$, water was ${\pm}5\;HU$ as within the reference point is ${\pm}10\;HU$. Conclusion: We was able to perform CT simulator QA and laser equipment QA more conveniently and fast using manufactured phantom at the same time. We will be able to make more accurate treatment plan that added to QA procedures using images at previous daily QA.

  • PDF

Entropy Extracting Method of Li-ion Battery Using Commercial Equipment (상용 장비를 이용한 리튬이온 배터리의 엔트로피 추출방법)

  • Park, Cheol-heui;Lee, Sang-Gug
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.318-320
    • /
    • 2017
  • 본 연구는 리튬이온 배터리의 엔트로피를 측정하는 방법인 ETM(Electro Thermodynamics Measurement)을 상용 장비에 적용하는 방법에 관한 것이다. 그리고 엔트로피 측정에 필요한 온도변경시간과 배터리의 relaxation 시간을 최소화함으로써, 측정의 정확성을 유지하면서 측정 시간을 최소화 했다.

  • PDF

Particle Size Distribution of Seoul Metropolitan Area (수도권지역 미세입자의 입경분포)

  • 유민경;조석연;한진석;이석조
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.05b
    • /
    • pp.195-196
    • /
    • 2003
  • 대기에서 입경에 따른 먼지의 무게농도를 측정하는 방법은 cascade impactor와 MOUDI(Micro-Orifice Uniform Deposit Impactor) 등이 비교적 잘 정립되어 있는 반면, 입경에 따른 먼지 개수를 측정하는 방법에 대한 연구는 아직 미진한 상태이다(McMurry, 2000). 현재 시도되고 있는 먼지 입경별 개수 측정방법은 SMPS와 APS를 결합하여 직경 0.005~10 $\mu\textrm{m}$에 이르는 먼지의 입경에 따른 개수를 측정하는 방법이다. 그러나, 일반대기 조건에서 SMPS와 APS의 정확성이 문제시되는데, 특히0.5~10$\mu\textrm{m}$의 먼지를 대상으로 하는APS는 대기에서 포집 효율이 낮을 수 있으며 또한 저농도에 대한 정확성도 문제시될 수 있다(Shen et al, 2002; Kim et al., 2002) (중략)

  • PDF

Worse Case Execution Time Analysis Tool Using The Run-Time Information (실행정보를 적용한 최악실행시간 분석도구)

  • Moon, In-Chul;Park, Hyun-Hee;Yang, Seung-Min
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2007.06b
    • /
    • pp.255-260
    • /
    • 2007
  • 내장 실시간 시스템은 논리적 정확성과 시간적 정확성을 모두 만족해야 하는 내장 시스템이다. 시스템의 시간적 정확성을 위해서는 해당 시스템에서 동작하는 태스크들의 스케줄링 가능성을 검사해야 한다. 스케줄링 가능성을 분석하기 위해서는 태스크의 실행 시간 분석이 선행 되어야 한다. 하지만 태스크의 실행 시간은 실행 시점에 따라 가변적이기 때문에 태스크의 정확한 실행 시간을 알아내기는 힘들다. 따라서 가능한 모든 경우를 고려하여 해당 태스크를 구성하는 코드 경로 중 최악의 경로일 경우의 실행 시간인 최악 실행 시간을 이용한다. 기존의 정적 최악 실행 시간 분석을 하는 도구의 경우 동적인 상황의 정보 부재로 인해 최악 실행 시간의 과대 측정 비율이 높다는 문제점이 있다. 본 논문에서는 정적 최악 실행 시간 분석 시 과대 측정 비율을 줄이기 위해 대상 기기에 실행 정보를 적용한 RunInfo(WCET analysis tool using the Run-Time Information) 분석 도구를 설계하고 구현한다. 실행 정보를 정의하고, RunInfo 분석 도구의 구조에 대해 설명한다. 그리고 실행 정보를 적용할 때, 고려할 점에 대해 알아본다. 성능 평가를 위해 RunInfo 분석 도구의 과대 측정 비율을 기존의 분석도구와 비교한다.

  • PDF

Development of Ultrasound Phantom for Volume Calibration (부피 측정을 위한 초음파 팬텀 개발)

  • Kim, Hye-Young;Lee, Ji-Hae;Lee, Kyung-Ja;Suh, Hyun-Suk;Lee, Re-Na
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.227-230
    • /
    • 2008
  • The purpose of this study was to design and construct an ultrasound phantom for volume calibration and evaluate the volume measurement accuracy of a 2 dimensional ultrasonic system. Ultrasound phantom was designed, constructed and tested. The phantom consisted of a background material and a target. The background was made by mixing agarose gel with water. A target, made with an elastic material, was filled with water to vary its volume and shape and inserted into background material. To evaluate accuracy of a 2 dimensional ultrasonic system (128XP, ACUSON), three different shapes of targets (a sphere, 2 ellipsoids and a triangular prism) were constructed. In case of ellipsoid shape, two targets, one with same size length and width (ellipsoid 1) and another with the length 2 times longer than width (ellipsoid 2) were examined. The target volumes of each shape were varied from 94cc to 450cc and measurement accuracy was examined. The volume difference between the real and measured target of the sphere shape ranged between 6.7 and 11%. For the ellipsoid targets, the differences ranged from 9.2 to 10.5% with ellipsoid 1 and 25.7% with ellipsoid 2. The volume difference of the triangular prism target ranged between 20.8 and 35%. An easy and simple method of constructing an ultrasound phantom was introduced and it was possible to check the volume measurement accuracy of an ultrasound system.

  • PDF