• Title/Summary/Keyword: 측정센서

Search Result 5,738, Processing Time 0.041 seconds

Signal Processing System of Multi-Fiber Bragg Grating Strain Sensor using Wavelength Scanning-Locking of a Fabry-Perot (Fabry-Perot 필터의 파장 스캐닝-로킹을 이용한 다중 Fiber Bragg Grating Strain 센서의 신호처리 시스템)

  • 이성은;한대우;이호준;김기수
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.24 no.8B
    • /
    • pp.1472-1479
    • /
    • 1999
  • In this paper, e proposed and implemented multi-FBG strain sensor system which used both wavelength scanning and locking of Fabry Perot filter for improve the performance of sensor system. The resolution of the sensor system is 3 and 10 $\mu$strain for the single and multi sensor system respectively.

  • PDF

IP Colum 특허기술 평가결과 활용사례 - 하중측정장치의 지각변동 예약한 NGWS - 기술가치평가 결과가 NGWS 완성의 중요한 토대

  • 한국발명진흥회
    • 발명특허
    • /
    • v.34 no.7
    • /
    • pp.38-42
    • /
    • 2009
  • (주)인벤티오는 신개념 하중측정 기술인 NGWS(Next Generation's Weighing Sensor)를 개발하고 있다. 이 기술은 기존 하중센서인 로드셀(Load Cell)과 마그네틱밸런스용 하중센서(Magnetic Balance)의 장점을 두루갖춰 현재 측정 곤란한 고하중, 고정밀 분야의 측정을 가능케 하는 등 기존 하중센서 시장을 재편할 것이라 예상되고 있다. (주)인벤티오는 이 기술의 완성도를 높이기 위해 기술보증기금으로부터 기술가치평가를 받았으며, 중소기업청에서 추진하는 2007년 신기술아이디어 사업으로 채택되어 기술개발 자금을 지원 받았다.

  • PDF

습도센서의 기술동향

  • 박찬복
    • 전기의세계
    • /
    • v.41 no.2
    • /
    • pp.12-21
    • /
    • 1992
  • 현재 습도측정분야는 측정의 정화도 향상 및 저온, 저습, 고온 등 특수 환경에서 측정을 위한 연구와 응답속도가 빠르고 정확도가 높으며 신뢰성 있는 습도센서 및 측정기기 개발연구가 진행되고 있다. 습도센서의 개발연구는 감습물질, 제조기술, 성능평가 연구를 포함하고 있으며, 물질 연구에서 고분자 감습재료에 대해 연구한 결과에 의하면, 고분자 감습물질에서 -OH기나 C=O기와 같은 친수성기와 탄화수소계열의 소수성기의 적절한 조합을 통하여 감습특성을 개선할 수 있으며 그한가지 방법으로 플라즈마중합이 시도되었다.

  • PDF

A Study of Improvement of Living Conditions Using Module-Type Sensor (모듈형 센서를 이용한 주거환경 개선 연구)

  • Cha, Jin-man
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.10a
    • /
    • pp.851-853
    • /
    • 2014
  • 현대 사회는 모든 분야에서 다양한 분야들의 기술들이 융합되는 사회이며, 이로 인해 각종 환경적 위험 요소 등이 존재한다. 그중 한가지는 유해 가스에 의한 피해이다. 산업이 발전하고, 편의 시설등이 늘어나면서 다양한 시설들이 설치되고 있다. 하지만 이와 함께 시설물들이 가지는 위험도 또한 높아지고 있다. 이에 본 연구에서는 센서를 이용한 위험요소 탐지와 환경측정 자료를 기반으로 일상 생활에 접할 수 있는 위험요소를 파악하고 개선하고자 하였다. 진행은 유해성분을 측정할 수 있는 센서를 이용한 시스템을 구성하고, 자료 분석을 통한 개선사항를 도출하는 방식을 취하였다.

  • PDF

Development of Multi-scale Model for Concrete Strength Estimation using Intelligent Self-diagnostic sensor (지능형 자가진단센서를 이용한 콘크리트 강도추정을 위한 다중스케일모델 개발)

  • Kim, Dong-Jin;Park, Woong-Ki;Lee, Chang-Gil;Hong, Seok-Inn;Park, Seung-Hee
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.303-306
    • /
    • 2011
  • 본 논문은 콘크리트의 양생 강도 발현을 모니터링하기 위하여 매립형 압전 센서를 이용하여 콘크리트 내부의 임피던스 및 유도초음파 신호를 측정함으로써, 콘크리트의 양생 강도를 실시간 추정할 수 있는 기법을 개발하였다. 임피던스 및 유도초음파 신호는 구조물의 물성을 나타내며 특히 양생 기간 중 임피던스 및 유도초음파의 변화는 해당 콘크리트 구조물의 강도변화를 나타낼 수 있다. 이를 이용하여 매립형 압전 센서로부터 저비용의 셀프 센싱 기반 임피던스 및 유도초음파를 계측하여 콘크리트의 임피던스 공진 주파수 및 유도초음파의 전달 강도를 측정하고 측정된 신호를 통하여 콘크리트 양생 강도를 추정할 수 있게 된다. 제안된 기법의 적용가능성을 검증하기 위하여 설계 압축강도 30MPa의 콘크리트 슬라브 내부에 매립형 압전 센서를 매립하고 양생기간 동안 임피던스 및 유도초음파 신호를 측정, 비교 분석 하였다. 측정된 신호 및 압축강도를 통하여 임피던스 및 유도초음파 기반 강도 추정 모델을 도출하고 보다 높은 정확도를 얻기 위해 다중스케일 강도 추정 모델을 개발하였다. 결과적으로 본 연구를 통해 매립형 압전 센서를 이용하여 콘크리트의 양생 강도를 실시간 모니터링할 수 있음이 검증되었다.

  • PDF

Development of Blood Pressure Measuring System using piezoelectric and photo sensor (광센서와 압력센서를 이용한 맥박측정시스템 개발)

  • Choi, Young-Suk;Kim, Kyung-Jae;Hong, Woo-Heon;Ryu, Jeong-Tak
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.14 no.5
    • /
    • pp.149-154
    • /
    • 2009
  • By increasing people's average life span, interest for health is highly growing. According to hoping to check their body condition, people have a medical checkup periodically to check their condition. But, they can prevent disease or are able to make a health care through checking people's pulse or blood pressure. In this paper, two different pulse measurement systems were developed, one system using a photosensor which is able to measure transmissivity's change through blood volume and another system using a piezo-electric sensor which can measure pulse when it measures radial artery's pressure in the wrist are realized. We compared two systems each other.

Magnetic Signals Analysis for Vehicle Detection Sensor and Magnetic Field Shape (자기신호분석을 통한 차량의 감지센서와 자기형상에 관한 연구)

  • Choi, Hak-Yun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.2
    • /
    • pp.349-354
    • /
    • 2015
  • This paper is about utilizing magnetic sensor to measure magnetic signal and analyze the form of magnetic signal for vehicle detection. For magnetic sensor, MR sensor from Honeywell company was used, and Helmholtz coil of which 3 axis' length is 1.2 m was manufactured to check the capability of the sensor and estimate its ability to detect the magnetic field. Vehicle detection was performed in following steps: installing sensor in road lane and non-road lane; estimating magnetic field when the vehicle is run by the driver; and estimating magnetic field of 7 different vehicles with different sizes. Also, sensor was installed at SUV and small-sized vehicle's park and non-park area to analyze the form of magnetic field. Lastly, the form of magnetic field made by different parts of the vehicle was analyzed. Based on the analysis, the form of magnetic field's magnetic peak value was bigger for road lane than non-road lane, complicated form was useful to distinguish the road lane above the installed sensor and the location of the running car, and the types of vehicle could be sorted because the variance of the magnetic field was bigger for bigger size of the vehicle. Also, it was confirmed that the forms of vehicle in parts-by-parts estimates.

공진반사 및 플렉시블 광 바이오센서 기술

  • Heo, Cheol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.106-106
    • /
    • 2012
  • 인체 내 소량의 생체성분을 감지하는 바이오센서 기술은 질병 진단뿐만 아니라 예방 및 관리로 의료서비스 확대 및 의료비 감소 효과를 가져올 수 있는 기술이다. 광 바이오센서는 광학적인 측정방법을 이용하여 다양한 생화학물질들의 상호 반응을 검출해 낼 수 있는 바이오센서로 현재 활발하게 연구가 진행되고 있다. 일반적으로 형광물질, 발색물질 등의 발광물질을 인식물질에 표지하여 인식물질과 분석물질과의 반응 유무를 표지된 발광물질의 광 신호를 감지하여 분석물질을 검출해내는 표지식 광 바이오센서 기술이 상용화되고 있다. 그러나 이러한 분석 방법은 민감도는 우수하지만 분석 시간이 매우 느리고, 고가의 분석 장비를 필요로 하는 단점들을 가지고 있다. 이러한 단점들을 극복하기 위하여 생화학 반응 유무를 표지물질 없이 광학적 방식으로 직접 측정해내는 비 표지식 광 바이오센서 기술이 최근 들어 많이 연구되고 있다. 본 논문에서는 비표지식이면서 분광기 없이 분석 가능한 공진 반사광 바이오센서 기술에 관한 내용을 소개하고자 한다. 공진 반사광 바이오센서는 광파장 이하의 주기를 가진 주기적 공진 격자 표면에서 일어나는 항원-항체 반응에 대한 공진 반사 파장을 측정하여 원하는 바이오물질을 고감도로 검출할 수 있는 바이오센서이다. 또한, 인체 내장을 위하여 플렉시블 기판 상에 GaN LED를 집적하여 전립선암 바이오 마커 검출에 대한 결과를 소개하고자 한다.

  • PDF

산소농도 측정을 위한 $UO_{2}$ 펠릿 공기산화로 장치의 갈바닉 센서와 지르코니움 센서의 특성 연구

  • Kim, Yeong-Hwan;Jeong, Jae-Hu;Lee, Hyo-Jik;Park, Byeong-Seok;Yun, Ji-Seop
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2007.05a
    • /
    • pp.151-152
    • /
    • 2007
  • ACP(Advanced Spent Fuel Conditioning Process)의 금속전환로에 $U_{3}O_{8}$을 공급하기 위하여 20 kgHM/batch의 $UO_{2}$ 펠릿(pellets)을 처리할 수 있는 공기산화로가 개발되고 있다. 그림 1은 산소농도 조절이 가능한 공기산화로이다. 공기산화로 이전의 공정인 슬리팅 장치에서 탈피복된 $UO_{2}$ 펠릿은 공기산화로로 운반되고, $500^{\circ}C$온도에서 공기를 공급하여 일정한 입도범위의 균질한 $U_{3}O_{8}$을 만든다. 그리고 다음공정의 금속전환장치로 이동된다. 본 논문에서는 모의연료의 산화에 대한 정확한 산소농도를 측정하고자 한다. 이를 위해서 갈바닉 센서와 지르코니움 센서가 사용되었고, 그 특성이 비교되었다. 14종의 금속 산화물이 혼합된 모의연료를 제조하여 산화실험이 수행되었으며, 시간변화에 따라 산소농도가 측정되었다. 산소농도 컨트롤러와 산소 센서를 사용한 공기산화로는 산소조절기에 의해 산소농도 100%까지 측정될 수 있다. 그림 2는 공기산화로의 산소농도를 조절할 수 있는 산소농도 측정시스템이다. 유량조절기(Mass Flow Controller)를 사용하여 질소와 산소의 혼합비를 변화시킬 수 있다. 또한 산소농도 측정시스템은 측정된 산소농도 값을 이용하여 $UO_{2}$의 산화시간을 계산하기 위하여 제작하였다. 산화시간 계산방법은 다음과 같다. 산소와 질소의 가스는 각각 40 L의 압력 봄베에 의해서 산소농도를 조절할 수 있는 공기산화로의 산소농도 측정시스템 안으로 유입된다. 유입된 산소와 질소의 배합은 컨트롤시스템 안에 있는 산소 유량조절기와 질소 유량 조절기를 사용하여 조절하며, 일정하게 혼합된 산소농도는 장치의 입구와 출구에서 산소 센서에 의해서 측정된다. 투입된 $UO_{2}$ 펠릿이 $500^{\circ}C$에서 반응하면서 공기산화로의 내부에 있는 산소농도가 감소된다. 이때 초기에 같았던 입력과 출력 농도가 시간의 흐름에 따라 감소되며, 펠릿이 완전히 산화됨과 동시에 출력 산소농도가 입력농도와 다시 같아질 때까지 소요된 구간이 산화시간이 된다.

  • PDF

Development of experimental water level measuring device using an Arduino and an ultrasonic sensor (아두이노와 초음파 센서를 이용한 실험용 수위 측정 장치 개발)

  • Yoo, Moonsung
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.18 no.4
    • /
    • pp.143-147
    • /
    • 2018
  • Water levels are measured in various fields such as sewage treatment plants, water treatment plants, rivers, dams, factory storages' tanks. Ultrasonic instruments for water level measurement are expensive and are used for industrial field. Rapid advances in electronics have made it possible to build a wide variety of measurement, monitoring and control functions at low cost. This study was started to make ultrasonic level measurement system at low price. The system was constructed with an Arduino, an ultrasonic sensor and a temperature sensor for use in the experiment. The ultrasonic sensor measures the time from the sensor to the liquid surface. The temperature sensor measures the atmospheric temperature and improves the accuracy of the ultrasonic distance measurement by correcting the sound speed. Arduino controls measurements and calculates the water level. All components of the system are assembled into a device holder. Experiments with this system show that the water level measured by the system is very close to the actual value. This system is also inexpensive and easy to install and maintain, making it suitable for laboratory use.