• Title/Summary/Keyword: 측정분해능

Search Result 161, Processing Time 0.065 seconds

Study on Coherent Anti-Stokes Raman Spectroscopy for Measuring Temperature Profile in a Flame (CARS를 이용한 화염내부 온도분포 측정연구)

  • 한재원;박승암;이은성;이충희;강경태;정석호
    • Korean Journal of Optics and Photonics
    • /
    • v.3 no.4
    • /
    • pp.266-272
    • /
    • 1992
  • A coherent anti-Stokes Raman spectroscopy (CARS) technique is applied to measure temperature profile in a flame. The CARS signal is obtained with BOXCARS phase matching to get better spatial resolution. A program routine for calculating temperature of the flame from the measured CARS spectra is studied. The routine includes the line broadening mechnism of the molecules described with a modified energy gap (MEG) law by using the perturbation theory. We have found that the temperature profile obtained with the MEG law is properly fit with the results measured with a thermocoulpe and calculated with the adiabatic theory.

  • PDF

SHRIMP V-Pb Zircon Age of a Felsic Meta-tuff in the Ogcheon Metamorphic Belt, Korea: Neoproterozoic (ca. 750 Ma) Volcanism (옥천변성대 규장질 변성응회암의 SHRIMP U-Pb 저어콘 연대: 신원생대(약 7.5억년전) 화산활동)

  • 조문섭;김태훈;김현철
    • The Journal of the Petrological Society of Korea
    • /
    • v.13 no.3
    • /
    • pp.119-125
    • /
    • 2004
  • Using a SHRIMP ion microprobe, we have dated zircon grains of a felsic meta-tuff from the so-cal1ed Munjuri Formation, Ogcheon metamorphic belt. The weighted mean $^{206}$ Pb/$^{238}$ U zircon ages obtained from 13 spot analyses of 10 grains provide an essentially concordant age of 747${\pm}$7Ma. This result corroborates the conventional U-Pb zircon age (756${\pm}$1Ma; Lee et al., 1998) for the Neoproterozoic bimodal volcanism in the Ogcheon belt. Thus, proto-basins associated with intracontinental, high-volcanicity rift in the Ogcheon belt are most likely to have formed at ca. 750 Ma.

System Design and Camera Calibration of Slit Beam Projection for Maximum Measuring Accuracy (슬릿광 3차원 형상측정에서 측정분해능 최적화를 위한 시스템설계 및 카메라보정)

  • 박현구;김명철;김승우
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.5
    • /
    • pp.1182-1191
    • /
    • 1994
  • This paper presents an enhanced method of slit beam projection intended for the rapid measurement of 3-dimensional surface profiles of dies and molds. Special emphasis is given to optimizing the design of optical system so that the measuring accuracy can be maximized by adopting two-plane camera calibration together with sub-pixel image processing techniques. Finally, several measurement examples are discussed to demonstrate that an actual measuring accuracy of $\pm$ 0.2 mm can be achieved over the measuring range of 500 mm{\times}300mm{\times}200mm$.

KSTAR 전자 사이클로트로 방출(ECE) 진단계

  • Jeong, Seung-Ho;Lee, Gyu-Dong;Kogi, Y.;Kawahata, K.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.411-411
    • /
    • 2011
  • KSTAR 토카막 플라즈마의 전자온도 측정을 위한 전자 사이클로트론 방출(ECE) 진단계가 완성되어 KSTAR 3차 운전기간 동안 전자온도를 측정하였다. ECE 진단계는 2단의 헤테로다인 수신기 2개와 75채널의 RF 검출기 그리고 비디오 증폭기로 이루어져있다. 2개의 헤테로다인 수신기의 주파수 범위는 각각 110 GHz~162 GHz, 164 GHz~196 GHz 이며 163 GHz multiplexer에 의해 ECE power를 나눠갖는다. 각 채널 사이의 주파수 간격은 1 GHz이며 토로이달 자장을 2.5T로 운전한다면 플라즈마 반경방향의 모든 위치에서 측정이 가능하다. 또한 시간분해능도 100 kHz로 우수하여 반경방향의 전자온도분포의 시간 변화를 측정할 수 있다. 이 포스터에서는 2010년 KSTAR 실험동안 반경위치에 대한 전자온도를 측정과 sawtooth, ELM 등 MHD 현상 관측 결과에 대해 발표하였다. 그리고 중성빔(NB) 가열을 하는 동안 나타난 H-mode 때 전자온도의 변화도 살펴보았다.

  • PDF

Compared Performance of Semiconductor SPECT in Myocardial Perfusion SPECT: Phantom study (범용 신틸레이터 감마카메라와 심근전용 반도체 감마카메라의 성능 비교 연구)

  • Bahn, Young Kag;Hwang, Dong Hoon;Kim, Jung Yul;Kang, Chun Koo;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.49-53
    • /
    • 2016
  • Purpose Recently, Cadmium-zinc-telluride (CZT) semiconductor myocardial SPECT (Single Photon Emission Computed Tomography) has been used myocardial scintigraphy. In this study, the performance of Semiconductor SPECT and conventional SPECT systems was compared by a comprehensive analysis of phantom SPECT images. Materials and Methods Methods: We evaluated the DSPECT CZT SEPCT (Spectrum-dynamic) and INFINA conventional (GE). Physical performance was compared on reconstructed SPECT images from a phantom. Results For count sensitivity on cardiac phantom images ($counts{\cdot}sec^{-1}{\cdot}MBq^{-1}$), DSPECT had a sensitivity of conventional SPECT. This classification was similar to that of myocardial counts normalized to injected activities from phantom images (respective mean values, $counts{\cdot}sec^{-1}{\cdot}MBq^{-1}$: 195.83 and 52.83). For central spatial resolution: DSPECT, 9.47mm; conventional SPECT, 16.90mm. For contrast-to-noise ratio on the phantom: DSPECT, 4.2; conventional SPECT, 3.6. Conclusion The performance of CZT cameras is dramatically higher than that of conventional SPECT. However, CZT cameras differ in that spatial resolution and contrast-to-noise ratio are better with conventional SPECT, whereas count sensitivity is markedly higher with the DSPECT.

  • PDF

An Estimate of Image Quality and Radiation Doses of Coronary Artery in MDCT Using Prospective and Retrospective ECG Gating Scan Mode (MDCT 관상동맥 조영 검사에서 전향적 동조화 및 후향적 동조화 기법의 화질과 선량 관계)

  • Oh, Jong-Kap
    • Journal of radiological science and technology
    • /
    • v.34 no.4
    • /
    • pp.315-321
    • /
    • 2011
  • The goal of this study is to reduce patient exposure dose by providing image quality and radiation dose according to inspection methods. Volume Computed Tomography Dose Index(CTDIvol) and Dose Length Product(DLP) of prospective and retrospective ECG gating snapshot segment of Coronary CT angiography(CTA) were measured each snapshot segment methods. CT number, noise, uniformity, and resolution were also measured using phantom under the same condition of coronary CTA. The results showed that CT number, noise, uniformity and resolution are similar to each other. In terms of CTDIvol and DLP, however, measurement dose of prospective ECG gating snapshot segment was lower than the retrospective case by 37.5% and 40.3%. Therefore, it is highly recommended that in the coronary CTA, prospective ECG gating scan mode should be chosen to reduce patient dose.

Development of Non-contacting Module for CRT Measurement (비접촉식 CRT 계측용 모듈개발)

  • 강성구;김정기;권진혁
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2000.02a
    • /
    • pp.204-205
    • /
    • 2000
  • 본 연구에서는 반도체 레이저 LD 혹은 백색광로부터 조사되는 빔을 CRT 모니터의 측정부에 입사시켜 패널 glass와 섀도우 마스크에서 반사되는 빔을 PSD에 조사하여 섀도우 마스크의 진동을 측정하였으며, CCD를 사용하여 열적변형과 패널 glass의 아랫면과 섀도우 마스크사이의 간격 Q값을 측정하였다. 사용한 PSD는 검출 영역은 12mm, 센서의 위치분해능은 0.2$mu extrm{m}$이며, 실시간적으로 처리할 수 있는 장점을 갖고 있다. CRT의 경우 전자빔의 충돌에 의한 섀도우 마스크의 열적 변형과 진동에 의한 섀도우 마스크의 떨림이 발생하여 화질이 저하된다. Q값의 정확한 계측과 섀도우 마스크의 열적변형 및 진동의 측정을 통하여 이들 현상이 발생되는 근본적인 취약구조를 발견함으로써 우수한 섀도우 마스크를 설계하고 제품의 성능을 향상시킬 수 있다. (중략)

  • PDF

초정밀 표면측정기술의 동향

  • 김승우
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.10 no.1
    • /
    • pp.22-27
    • /
    • 1993
  • 산업기술의 발달에 따라 각 분야마다 정밀한 부품을 요구하고 있다. 이는 이들 부품이 시스템의 성능에 영향을 미치고 있기 때문이다. 부품의 정도는 길이정도와 표면의 정도를 모두 의미한다. 길이정도는 부품의 상대적 크기정도를, 표면정도는 3차원 형상정도를 나타낸다. 이들 부품의 정도를 평가하기 위해서는 반드시 측정이라는 방법이 수행되어야 하며, 측정은 요구되는 측정정도에 따라 이에 상용되는 방법으로 행해지게 된다. 요구되는 측정정도는 시간이 지남에 따라 점차 증가되고 있다. 이 러한 경향은 그림1의 시대에 따른 측정정도를 보면 확인할 수 있다. 시대에 따라 측정정도는 급격히 증가하고 있고 현재의 측정은 초정밀측정이라 말하는 약 0.1nm의 정밀도를 갖고 있다. 측정정도에 따라 표면측정기술도 여러가지 방법이 행해지고 있는데 이들 측정방법은 크게 접촉식 측정방법과 비접촉 측정 방법으로 나눌 수 있다. 대표적인 접촉식 측정방법으로는 촉침식 측정방법을 들 수 있다. 이 방법은 다이아몬드 촉침을 표면상에 접촉하여 주사이동하게 하고 이때 표면의 요철에 따른 촉침의 상하운동을 고성능 변위센서를 이용하여 표면형상을 측정하는 것이다. 이는1nm의 수직분해능을 갖고 측정이 가능 하다. 이 방법은 표면에 접촉함으로 인해 신뢰성이 높지만, 표면의 접촉압력으로 인해 표면의 손상 우려가 있다. 이런 이유로 현재 비접촉 측정방법이 주목받고 있다. 표면측정을 실현하는 데에는 광학 기술이 적극적으로 활용되고 있으며, 최근에는 물리학의 원리들이 도입되고 있다. 본 글에서는 이러한 측정기술의 기본원리를 소개하고 각 기술이 응용되는 예를 소개하고자 한다.

  • PDF

Determination of the Position and Velocity of the Solid-Liquid Interface During Directional Solidification of Metals based on Guided Ultrasonic Waves (유도초음파를 이용하여 금속의 방향성 고체화과정에서 고체-액체 경계면의 위치와 속도결정)

  • 김태진;슈마크텔미샤엘;그릴볼프강;쉬벤부쉬안드레;찜머만게르하르트
    • The Journal of the Acoustical Society of Korea
    • /
    • v.17 no.2
    • /
    • pp.79-83
    • /
    • 1998
  • 높은 온도에서 금속물질이 응고되는 동안에 물질의 구조는 결정성장속도비율에 따 라 크게 좌우된다. 유도초음파를 기초로 한 펄스-에코 초음파실험기술과 함께 고체-액체 경 계면의 위치와 속도를 실시간으로 측정할 수 있어 고체화되는 동안의 용광로 파라메터들을 조절하는데 사용될 수 있다. 실험은 Bridgman형의 용광로에서 CuMn-막대시료에 대하여 서로 다른 냉각비율로 수행되었다. 열적평형상태에서 경계면의 위치에 대한 측정분해능은 약10㎛이다.

  • PDF

Design of DOI Detector Module for PET through the Light Spread Distribution (빛 분포를 통한 양전자방출단층촬영기기의 반응 깊이 측정 검출기 모듈 개발)

  • Lee, Seung-Jae;Baek, Cheol-Ha
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.5
    • /
    • pp.637-643
    • /
    • 2018
  • A depth of interaction(DOI) detector module using a block scintillator and a pixellated scintillator was designed, and layer discrimination ability was calculated using DETECT2000. The block scintillator was used to improve the sensitivity and the spatial resolution was improved by measuring the DOI. The DOI was measured by analyzing the signal characteristics of each channel of the changed distribution of light. The detector module was composed to the block scintillator in the top layer and the pixellated scintillator in the bottom layer, which changes the distribution of light generated from a scintillator interacting with a gamma ray. In the flood image, the top layer was able to acquire the image at the position similar to the position of the bottom layer because the bottom layer consist of the pixellated scintillator. By using the Anger algorithm, the 16 channel signal was reduced to 4 channels to facilitate the analysis of the signal characteristics. The layer discrimination was measured using a simple algorithm and the accuracy was about 84% for each layer. When this detector module is used in preclinical PET, the spatial resolution at the outside of the field of view can be improved by measuring the DOI.