Analysis on the Performance Degradations of Chung-Ju DGPS Reference Station by Radio Environment (전파환경에 의한 DGPS 충주 기준국의 성능저하 분석)

  • Park, SulGee;Han, YoungHoon;Park, SangHyun;Choi, YongKwon;Lee, Sang Jeong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.9
    • /
    • pp.1822-1829
    • /
    • 2016
  • DGPS Reference station is established in Korea for improvement of GPS navigation accuracy and needs of integrity. Recently, DGPS stations provide user positioning information on land as well as ocean. However, this paper investigated visibility and interference environment for performance degradation of Chung-ju DGPS reference station. In case of Young-do reference station, visibility and interference environment were satisfied with reference standard. In case of Chung-ju reference station, visibility was satisfied with 7 degree elevation angle. However, interference environment was not satisfied with reference standard of -50dBm. This paper proposed time differential measurement analysis method excluding error of signal noise for analyzing measurement error. Chung-ju reference station measurement analysis result is three times the error than on Young-do in Dec, 2015. In addition, this paper has confirmed measurement performance degradations because of reference station equipment problem. Future study will be carried out performance analysis of 17 DGPS reference station.

단기 측정용 오존 간이 측정기의 실험 챔버 내에서 성능에 관한 연구

  • Jeong, Sang-Jin
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2007.05a
    • /
    • pp.31-33
    • /
    • 2007
  • 본 연구에서 개발한 단기측정용(1시간) 오존 간이측정기는 $40ppm{\ast}min$(1시간 환경기준 농도(0.15ppm)에 266분(약 4.4시간) 노출되는 경우)까지 선형 변화를 나타내었으며 그 이상에서는 비선형적으로 변화하였다. 본 연구에서 개발한 단기측정용 오존 간이측정기의 현장 적용을 위해서는 현장측정에 대한 검증이 필요하며 기준성 오염물외 다른 오염물질과 실외 기상현상(예; 풍향, 풍속, 온도 등)의 영향 검토에 대한 이후의 연구가 필요하며 간이측정기의 장기간 보관을 위한 저장법에 대한 장래 연구가 필요하다.

  • PDF

Evaluation of Strength and Concentration of Odor according to the Air Sampling and Measuring Methods (악취 측정과 시료채취기법이 악취세기 및 성분농도 평가에 미치는 영향)

  • 양성봉;김현정;김석민
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2000.04a
    • /
    • pp.127-128
    • /
    • 2000
  • 악취 측정은 악취의 배출 허용을 판정하는데 대단히 중요한 기술이라 할 수 있다. 우리나라의 경우 악취배출 허용기준은 대기환경보전법에 명시되어 있으며 그 규제기준의 준법성 여부는 직접 관능법에 의한 악취 세기, 희석배율(악취농도) 및 기기측정에 의한 악취성분의 농도에 의해 판정하고 있다. 최근 악취민원이 전국으로 확산되면서 악취 배출원을 갖는 사업장과 악취오염의 피해를 입는 주민의 입장에서 악취의 허용배출의 정도에 대한 견해차이가 부각되면서 악취의 측정이나 시료채취에 대한 합리성이 요구되고 있다.(중략)

  • PDF

Analysis of Measurement Accuracy Based on Confidences for Narrow-Band Underwater Acoustic Measurement (협대역 수중음향측정을 위한 신뢰도 기반의 측정정확도 분석)

  • 도경철;최재용;이용곤
    • The Journal of the Acoustical Society of Korea
    • /
    • v.19 no.4
    • /
    • pp.16-22
    • /
    • 2000
  • In order to predict the performance and the usefulness of the narrow-band underwater acoustic measurement system at design stage, whose error variance is not clearly described, in this study a boundary equation to estimate the measurement accuracy is proposed based on the confidency as SNR variation. The boundary is presented as a function of SNR and the number of samples. In this paper, the measurement performance for narrow-band signal is simulated by the proposed boundary equation and the results are reviewed in the biased noise condition and separately in the background noise rejected condition.

  • PDF

The Status and Improvement of Hydrological Survey Standardization (수문조사 표준화 현황 및 개선방안)

  • Shim, Eun Jeung;Kim, Sam Eun;Jang, Bok Jin;Jung, Sung Won
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.471-471
    • /
    • 2018
  • 국가 수자원 관리에 가장 기초가 되는 수문조사는 측정과 자료 분석을 위해 행해지는 모든 과정에서 자료의 정확성과 신뢰성이 담보되어야 한다. 현재 수문조사는 국토교통부를 비롯하여 환경부, 수자원공사 등 다양한 부처와 기관에서 수행하고 있으며, 수문조사 방법 및 기준표준화 연구(2009), 수문조사 관련 법정 행정규칙 마련, 수자원 조사법 제정, 수문자료 공인 및 저장, 배포, 활용, 기준고시 등을 통해 수문조사 발전 및 표준화를 위한 노력을 해오고 있다. 하지만 국가차원의 표준화(기준과 매뉴얼)가 아직 미진하여 기관별 생산 자료의 품질차이가 발생하고 있다. 국내의 현장여건은 식생, 공사, 모래하상 등으로 과거와 다르게 점차 다양화 되고 있으며, 국외와 차별화 된 국내 하천만의 특성으로 반영되고 있다. 또한 최근 ADCP와 같은 첨단장비 활용이 증대되는 추세인데 비해 첨단장비 관련 기준은 아직 미비한 부분이 많다. 국내 측정환경이 고려된 수문조사 표준화를 위해서는 USGS와 같은 선진국의 국제기준 검토와 함께 각 하천 환경에 맞는 유량측정 방법 및 기술을 개발하고, 다양한 현장 특성이 반영된 측정방법의 적용과, 자료 분석을 통한 기준제시가 필요하다. 첨단 장비 및 관련 기술을 활용한 수문조사 선진화를 위해서는 정확한 첨단장비 활용에 대한 표준이 필요하다. 즉 수문조사 전반에 대한 표준화와 이를 통한 공유와 활용이 이루어져야 한다. 한국수자원조사기술원(구 유량조사사업단)에서는 2007년부터 수문조사를 수행하면서 국내 하천유량조사 경험과 기술 노하우를 바탕으로 수문조사 분야별 측정방법, 장비, 레이팅, 자료 분석 등에 대한 수문조사매뉴얼과 가이드라인을 발간하여 실무에 적용, 활용하고 있다. 이러한 노력은 국내 수문조사 표준화를 정착, 발전시키고 국제 표준화에 기여할 수 있는 계기가 될 것으로 생각된다.

  • PDF

Service analysis and propagation measurement for DGPS land-based reference station in Korea (국내 DGPS 내륙 기준국 전파 측정 및 서비스 분석)

  • Jeon, Joong Seong;Kim, Young Wan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.4
    • /
    • pp.437-443
    • /
    • 2014
  • Based on the radio wave propagation measurement of DGPS land-based reference stations, the DGPS service coverage and signal quality in the receiving points are analyzed in this paper. The DGPS signal strength and SNR in the receiving point are measured in the winter and summer season, respectively. In case of DGPS reference station that can not provide the designed service coverage, the solution to improve the service coverage is presented in this paper. Almost all DGPS reference station except reference station with low ground conductivity or mountainous terrain provide the DGPS service coverages of 80% or more of the designed service area. The service coverages of DGPS reference stations can be improved to pre-designed service area in case of installation management of DGPS site on the plain terrain and good ground conductivity. It is necessary to get the high efficiency of transmitting antenna to improve the service area.

A Plan of SLA for Internet Phone Service (영상전화서비스의 SLA 방안)

  • Hong, Jae-Hwan;Nam, Ki-Dong;Min, Gyeong-Ju;Lee, Jong-Kok
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.111-116
    • /
    • 2007
  • 본 논문에서는 인터넷전화 품질평가를 위한 국내 동향에 대하여 기술하고, BcN영상전화 서비스에 대한 SLA 품질지표 및 품질기준을 국내외 동향 및 기준표준화에 근거하여 마련하고 이를 검증하기 위한 품질측정 방법을 제시하고자 한다. 이를 통해서 영상전화 서비스의 SLA 품질기준이 조기에 마련되어 국내 통신사업자들의 이용약관에 반영되기를 기대한다. 따라서 본 논문의 목차는 서론, SLA 개요, 영상전화 서비스의 품질지표 및 기준, 품질지표별 측정방법 및 시험측정 결과에 대하여 기술하였다.

  • PDF

A study on acoustical environment of classrooms (강의실 내 음환경에 관한 연구)

  • Lee Chai-Bong;Kim Yong-Man
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.501-504
    • /
    • 2002
  • 본 논문에서는 최근 건축공간에 있어서 음환경에 대한 관심이 놓아지면서 학교 건축물에 있어서 강의실내의 음환경을 측정하고, 학교건축물에 대한 음환경 기준을 확립하는 데에 기초자료와 필요한 제안을 하는 것이 목적이다. 현재 음환경 기준은 단순히 소음fp밸이나 잔향 시간과 같은 단순한 물리특성만을 기준으로 하고 있다. 여기서는 강의실 내의 잔향시간, D, STI 등외 물리지표와 설문조사 등 주관적 평가를 통해 새로운 음환경 기준을 제시하려고 한다. 여기서 사용되는 물리지표로는 TSP(Time-Streched-Pulse)신호를 사용하여 잔향시간과 D(Deutlichkeit), STI(Speech Transmission index)를 산출하였다. 강의실의 화자의 위치에서 1.5m 높이에 스피커를 놓고 청취자의 위치인 여섯 점에서 무지향성 마이크로폰을 1.2m 높이에 놓고 마이크로폰으로 들어온 임펄스 응답을 측정하고, 강의실 내의 잔향시간과 D, STI를 산출하였다. 다음에 설문조사를 실시하여, 앞에서 측정한 물리지표와 설문조사를 통해 얻은 주관적 평가와의 상관관계를 파악하였다.

  • PDF

Rate-Distortion Characteristics in Low Bit-rate Video Coder (낮은 비트율 동영상 부호기의 율-왜곡 특성)

  • Hwang, Jae-Jeong;Jee, Seok-Sang;Huh, Young
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.26 no.3B
    • /
    • pp.295-301
    • /
    • 2001
  • 전송과정에서 발생하는 왜곡량에 따라 전송률의 하한이 결정되는 율-왜곡 이론은 시간적으로 민감한 부분을 왜곡없이 부호화하여 전송하는 영상 시스템에서 기본이 되는 중요한 요소이다. 율-왜곡 이론은 정보량의 개념으로부터 시작되어 원 신호의 확률분포와 왜곡의 측정기준에 의해 결정되는데, 이 논문에서는 가우시안과 라플라시안 분포함수에 절대치 오차기준과 자승 오차기준을 적용하여 율-왜곡 함수를 각각 구하였다. 나아가서 저전송률 부호기로 개발된 H.263 부호기에 이 함수를 적용하여 분석하였다. 비교를 위해 자승 오차기준에 위한 이론치와 실제 측정치를 제시하였다. H.263 부호기는 엔트로피 부호화, 부호화를 블록 패턴 등 다양한 기법을 사용하여 율-왜곡 함수에 의한 이론치보다 주어진 MSE에서 정규화 비트율이 최대 0.55만큼 더 낮은 전송률을 얻을 수 있었다.

  • PDF

Comparative study on experimental measurements of discharge using various flow meters (유속측정 기기별 측정성과에 대한 실험적 비교분석)

  • Lee, Jae-Hyug;Kang, Kyang-Min;Jung, Sung-Won;Kim, Tae-Woong
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.1908-1912
    • /
    • 2009
  • 유량자료는 물의 순환과정을 규명하고 효율적인 수자원 개발 및 이수 치수 계획 등에 매우 귀중하게 이용된다. 그러나 이러한 유량자료를 확보하는 데는 많은 시간과 경비 등이 요구되기 때문에 주요 수위의 유량측정자료로 수위-유량관계 곡선식(Stage-Discharge Curve)을 개발하여 유량자료를 환산하고 있다. 따라서 수위-유량관계 곡선식의 신뢰도는 유량자료의 품질에 절대적인 영향을 미치는 요인으로 작용된다. 수문학을 연구하는 많은 학자들은 고품질의 유량자료를 생산하여 신뢰성 있는 곡선식을 개발하고자 유량측정 방법과 기준, 장비개량 등에 관한 연구를 수행하고 있다. 측정하고자 하는 기기별 측정 성과에 대한 연구 자료가 거의 없이 국내에 보급된 다양한 유속측정기기를 사용하여 유량자료를 생산하여 활용하고 있다. 본 연구에서는 규격화된 콘크리트 수로에 일정한 유량을 흘려보내고 다양한 측정기기를 이용하여 유속을 측정하였다. 그리고 이 측정성과를 이용하여 유량을 산정하고 비교분석하였다. 실험을 위해서 국내에서 일반적으로 사용되고 있는 측정기기로 마그네틱유속계(Electromagnetic Current Meter), 휴대용유량계(Flow Meter), 프라이스유속계(USGS Type AA Current Meter), 갈수기용유속계(USGS Pygmy Meter)등의 장비를 사용하였으며, 동일한 조건에서 유량을 얻음으로 측정 기기가 제시하는 유량을 알 수 있었다. 비교검토에 적용하고자 측정한 수심으로는 0.25m, 0.30m, 0.35m, 0.40m의 4개 Case로 진행이 되었으며, 측정방법으로는 도섭법(Wading Measurement)에 의하거나 케이블웨이(Cableway), 교량법(Bridge Measurement), 보트법(Boat Measurement)등이 있으나, 신뢰성과 정확도를 높이기 위해 도섭법으로 수면에서 0.6d 지점의 유량측정방법(1점법)을 적용하였다. USGS Type AA Current Meter, USGS Pygmy Meter는 유속측정기기의 검교정을 받았으므로 다른 실험유속측정치의 비교를 위한 기준값으로 사용하였다. 따라서 국내에서 널리 사용되는 측정기기(Electromagnetic Current meter, Flow Meter, USGS Type AA Current Meter, USGS Pygmy Meter)별 검토 결과 프라이스유속계를 기준으로 마그네틱유속계는 ${\pm}$10% 이상, 갈수기용 유속계 및 휴대용 유량계는 ${\pm}$5% 미만의 차이가 있음을 확인할 수 있었다.