• Title/Summary/Keyword: 측정값 선별

Search Result 127, Processing Time 0.024 seconds

Relationship Between Vergence Facility and Fusional Vergence (버전스용이와 융합버전스의 관계)

  • Shin, Hoy-Sun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.3
    • /
    • pp.37-42
    • /
    • 2009
  • Purpose: There is uncertainty if the vergence facility would provide clinically significant supplementary information to the fusional vergence measurements. The purpose of this study was to determine the relationship between vergence facility and fusional vergence in a group of symptomatic subjects. Methods: A total of 114 symptomatic subjects aged 9 to 13 years, who passed the vision screening test, participated in this study. Vergence facility was measured with 8$\Delta$ BI/8$\Delta$ BO flipper lenses and a suppression control target, the 20/30 letter line on Vectogram 9 (Bernell, USA). Near fusional vergence was measured with a single 20/30 vertical line target by Von Graefe technique. In order to avoid excessive convergence stimulation, negative fusional vergence (NFV) range (blur, break and recovery) was measured followed by positive fusional vergence (PFV) ranges (blur, break and recovery). Results: Pearson correlations were calculated and showed no correlations between vergence facility and any of fusional vergence measurements (p>0.05). Also, there were no significant differences of vergence facility measurements on the compensating vergence that passed or failed Sheard and Morgan's criterion for comfortable vision (p>0.05). Conclusions: There was no correlation between vergence facility and fusional vergence among symptomatic subjects. Hence, both vergence facility and fusional vergence should be assessed for those with binocular dysfunction in order to make an accurate diagnosis and management plan.

  • PDF

Laboratory Test of CLSM with Botton Ash (Bottom ash를 이용한 유동성 뒤채움재의 실내모형실험)

  • Lee, Kwan-Ho;Lee, Kyung-Joong;KIm, Yun-Tae;Cho, Jae-Yun
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.197-197
    • /
    • 2011
  • 최근 들어 전력 사용량의 증가로 인한 화력발전소의 부산물인 석탄회 중 바텀애시와 각종 공공사업과 관련하여 해마다 현장발생토의 발생량이 지속적으로 증가하고 있는 추세이다. 바텀애시와 현장발생토사를 효과적으로 재활용하는 방법 중 유동성 뒤채움재를 개발하여 활용하는 방안을 모색하기 위한 연구이다. SP로 분류된 흙 현장발생토와 서천 화력발전소에서 발생하는 석탄회 중 입경이 0.9~1.5mm의 바텀애시만을 선별하여 현장발생토와 바텀애시의 비율을 7 : 3으로 변환한 최적배합을 선정하여 강재로 제작된 가로 80cm, 세로 60cm, 높이 90cm의 모형토조를 이용하여 실험을 진행하였으며, 사용상 지하 매설이 되는 관의 거동 특성은 확인하기 위하여 내경 30cm, 두께 8mm의 연선관 중 하나인 PVC관을 원형지하매설관으로 선정하여 배합을 타설하는 과정과 타설 후 7일간의 양생기간을 거친 후 차량하중으로 가정할 수 있는 하중을 가하여 원형지하매설관의 관외부에서 수직방향과 수평방향의 토압과 관내부의 수직 수평방향 변위 그리고 관 자체의 횡 종단 변형을 측정하여 원형지하매설관의 거동특성을 파악하였다. 타설시 지하매설관은 유동성 뒤채움재의 특성으로 인하여 시간이 지남에 따라 안정화되는 것을 확인할 수 있었으며, 최대하중을 3300kgf로 하여 하중 재하 후 지하매설관의 거동특성은 대체적으로 일반 모래를 사용하여 실험한 값보다 적은 변형 특성을 보이고 있으나 수평토압의 경우 일반적인 흙의 변형과 전혀 상이한 결과값을 보이는 경우도 있어 추가적인 실험 및 고찰의 필요하다. 본 실험에서 사용한 최적배합비 이외의 배합으로 같은 실험을 수행하여 바텀애시 량의 가감 및 재활용 재료인 폐타이어 고무칩등을 첨가한 실험을 계획하고 있으며 추후 실내시험과 모형실험을 토대로 유한요소해석을 추가로 시행하여 실험값과 해석값의 비교를 할 예정이다.

  • PDF

Fractional Anisotropy of Diffuse Tensor Imaging of Normal Subjects in the Regions of the Brain White Matter According to Age and Body Mass Index (BMI) (연령과 체질량지수(BMI)에 따른 뇌 백질 부위의 정상인 확산텐서영상 비등방도에 대한 연구)

  • Jeong, Jae Beom;Kwak, Jong Hyeok;Kim, Dong Hyeon
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.2
    • /
    • pp.253-260
    • /
    • 2018
  • Diffusion tensor images were obtained to investigate the damage of brain white matter in non-smokers and an adequate drinking group (less than 10 points) selected by scores of the Korean versions of alcohol use disorders identification test questionnaire. Factional anisotropy (FA) values, according to the variables of age and body mass index (BMI), were not statistically significant in all regions of the brain white matter after measurement of factional anisotropy (FA) values by the tract-based spatial statics (TBSS) method. In other words, age and body mass index (BMI) do not significantly affect the microstructural changes of the brain white matter.

Electromagnetic Wave in all Base Stations (다기지국 환경에서 전자파 노출량)

  • Cho, Euy-Hyun;Park, Jeong-Kyu
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.9
    • /
    • pp.26-44
    • /
    • 2011
  • The Study was carreid out to see whether the intensity of electromagnetic waves in each floor of a building where the sharing base station has been established is harmful to a human body, and to expect the intensity of the waves in the building. The investigate was performed on both of sharing base station either with many scatterers or without any of them. To satisfy the international standard and the domestic TTA standard, rms for each of the electromagnetic wave of every floor in the building with the station was measured from 3 location of 3 heights(1.1m,1.5m, and 1.7m). Max of the measured rsm from the each of the frequencies in the nine location was confirmed to be 48.12%(the rooftop measured value) at most, compared to the human body protection standard. The value was confirmed to satisfy the human body protection standard for each frequency. And the total value of the calculated exposure indexes for each frequency was determined to be more than 7 times lower at most, which was 0.1445, compared to the 1 standard. Since P value in both of 868MHz and 2.14GHz electromagnetic waves intensity for each base station and floor was less than 0.05, it was revealed to be meaningful, and since R-Sq(adj) value showed a value more than 50%, the regression equation was determined to fully absorb the data information. However, although the P value of both of 868MHz and 2.14GHz electromagnetic waves intensities under the integrating terms of the base station data and the floor data was showed to be less than 0,05, since R-Sq(adj) value of 868MHz electromagnetic waves intensity presented a value smaller than 50%(34.15%), it was determined that the 868MHz electromagnetic waves intensity is very much influenced by an environment with a base station. Because the electromagnetic waves intensity of 2.14GHz show R-Sq(adj) value bigger then 50%(51.8%), The regression equation model of 2.14GHz electromagnetic waves intensity was confirmed to be proper. It also turned out not to be effected by the surrounding environment near a building with the base station and the intensity of electromagnetic waves for each floor of such building was expectable by the regression equation.

The Correlation between Uneven Ripening and Respiration Rate of Tomato at Breaker Stages (Breaker 단계 토마토의 착색불량과 호흡률간 상관관계)

  • Kang, Ho-Min;Kim, Young-Shik
    • Journal of Bio-Environment Control
    • /
    • v.19 no.2
    • /
    • pp.93-96
    • /
    • 2010
  • Breaker stage tomato fruits that were stored at low temperatures show typical chilling symptoms such as uneven ripening and a high respiration. Experiments were performed to assess and compare these chilling injury symptoms of breaker stage tomato fruits, and to gather basic data that can be used to decide whether horticultural crops receive chilling injuries. Tomato fruits that had been sorted in the breaker stage were stored at $2^{\circ}C$ for 0, 3, 6, and 9 days, and then their respiration rates were measured at 3, 6, 9, 12, 24, 36, and 48 h after moving them to room temperature. This treatment was repeated twice on the same procedures, except the storage periods, which were changed to 0, 1, 2, 3, and 10 days. The respiration rate was increased in a 1 day storage treatment, and the increasing rate rose higher with extended storage periods. The $a^*$ value, which represents the surface color of tomato fruits, was measured 10 days after moving to them into room temperature. Those with an increased $a^*$ value rate got dull and showed uneven coloring after 2 days' storage treatment. These two factors, the respiration rate and $a^*$ value of the surface, showed a high correlation (r = 0.9716, p < 0.001). Therefore, the chilling injury of breaker stage tomato fruits can be diagnosed by measuring the respiration rate after moving them into room temperature, and the degree of chilling injury can also be assessed in terms of the respiration increase rate.

Development of Sludge Concentration Estimation Method using Neuro-Fuzzy Algorithm (뉴로-퍼지 알고리즘을 이용한 슬러지 농도 추정 기법 개발)

  • Jang, Sang-Bok;Lee, Ho-Hyun;Lee, Dae-Jong;Kweon, Jin-Hee;Chun, Myung-Geun
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.25 no.2
    • /
    • pp.119-125
    • /
    • 2015
  • A concentration meter is widely used at purification plants, sewage treatment plants and waste water treatment plants to sort and transfer high concentration sludge and to control the amount of chemical dosage. When the strange substance is contained in the sludge, however, the attenuation of ultrasonic wave could be increased or not be transmitted to the receiver. At that case, the value of concentration meter is higher than the actual density value or vibrated up and down. It has also been difficult to automate the residuals treatment process according to the problems as sludge attachment or damage of a sensor. Multi-beam ultrasonic concentration meter has been developed to solve these problems, but the failure of the ultrasonic beam of a specific concentration measurement value degrade the performance of the entire system. This paper proposes the method to improve the accuracy of sludge concentration rate by choosing reliable sensor values and learning them by proposed algorithm. The prediction algorithm is chosen as neuro-fuzzy model, which is tested by the various experiments.

Multidetector Computed Tomography in Patients with Femoral Neck Fracture for Assessing Osteoporosis: Comparison with Dual Energy X-Ray Absorptiometry (대퇴골 경부 골절 환자에서 골다공증 평가를 위한 다중검출 CT의 이용: 이중에너지 X-선 흡수계측법과의 비교)

  • Hyo Jeong Lee;Ji Young Hwang
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.1
    • /
    • pp.173-181
    • /
    • 2021
  • Purpose To evaluate the ability of the Hounsfield unit (HU) measurement of the femoral neck during multidetector computed tomography (MDCT) for assessing osteoporosis compared with dual-energy X-ray absorptiometry (DXA). Materials and Methods Forty-two patients with femoral neck fractures who underwent MDCT and DXA from July to December 2016 were included in this study. HU measurements were made of the cancellous portions of the normal contralateral femoral neck on MDCT. Bone mineral density (BMD) and T-scores were obtained at the femur DXA. Correlations of HU values with BMD and T-scores were analyzed using Spearman's correlation test. Results The mean BMD and T-score of the femoral neck were 0.650 g/cm2 and -2.4, respectively. The mean HU values for the normal, osteopenia, and osteoporosis groups were 131.9, 98.9, and 41.3, respectively. HU values at the femoral neck were positively correlated with BMD (r2 = 0.670; p < 0.001) and T-scores (r2 = 0.676; p < 0.001). Conclusion The HU values of the femoral neck on MDCT are significantly correlated with BMD and T-scores of femur DXA. The HU values may serve as a diagnostic tool for the screening of regional bone quality when MDCT is performed for other reasons.

Effects of Water Extract from Omija (Schizandra chinensis Baillon) on Nabak Kimchi Preservation (오미자 물추출물이 나박김치의 저장성에 미치는 영향)

  • 문성원;장명숙
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.29 no.5
    • /
    • pp.814-821
    • /
    • 2000
  • In order to investigate the possible use of omija extract as natural preservatives for nabak kimchi omija extract was tested for antioxidation and electron-donating ability and further more antimicrobial activites against lactic acid bacteria of nabak kimchi. The concentration of the test sample used were 0.5, 1.0, 1.5, 2.0%. Antioxidative activity measured the TBA value, when omija extract concentration % is higher the antioxidation effect were more evident with the increased omija extract concentrations, and showed a high electron donating activity more than 1.0%. As the result of isolated lactic acid bacteria from nabak kimchi the primary separation tool 117 strains, of these 4 strains which had excellent growth and a strong acid formation capability was selected the second time and Lactobacillus brevis, Lactococcus faecalis, Leuconostoc mesenteriodes, Lactobacillus palantarum were identified. After measuring the antimicrobial activity of the four lactid acid bacteris, except Lactobacillus brevis the other three bacteria showed strong antimicrobial activities. The results suggest the possible use of the omija extract as natural preservative for nabak kimchi.

  • PDF

A Study on the Relative Positioning Technology based on Range Difference and Root Selection (신호원과의 거리 차이와 실근 선택 알고리즘을 이용한 상대위치 인식 기술 연구)

  • Oh, Jongtaek
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.13 no.5
    • /
    • pp.85-91
    • /
    • 2013
  • For location based service and context awareness services, accurate indoor positioning technology is essential. The TDOA method that uses the range difference between signal source and receivers for estimating the location of the signal source, has estimation error due to measurement error. In this paper, a new algorithm is proposed to select the real root among calculated roots using the range difference information, and the estimated position of the signal source shows good accuracy compared to the existing method.

Analyze dosimetry with and without shielding when amplifying scattered rays (산란선 증폭시 차폐체 유무에 따른 선량 분석)

  • Chang Ho Cho;Jeong Lae Kim
    • The Journal of the Convergence on Culture Technology
    • /
    • v.10 no.3
    • /
    • pp.819-825
    • /
    • 2024
  • The reason for recording dose data when using a diagnostic radiation source is to record and manage the dose to healthcare personnel and patients. The purpose of this study was to verify the difference in radiation dose when using diagnostic radiation generating devices and to inform users' awareness of dose reduction through measurement and analysis of dose in situations with and without shielding. The dose analysis of each equipment for two Korean C-arms and two German C-arms showed that the Korean FPD type C-arm had the highest dose value, followed by the German I.I type C-arm, German FPD type C-arm, Korean, and I.I type C-arm. The results of the dose analysis with and without shielding showed that the dose to the human phantom in a normal atmosphere increased by about 2 times due to scattered radiation, but the dose to the human phantom was reduced by about 5 times by wearing a shield (0.5mm/lead apron). More important than the management of radiation dose is the study of how to reduce exposure when using radiation, and since the radiation dose output from different equipment is different, it is necessary to provide dose information with and without shielding.