• Title/Summary/Keyword: 측정값 선별

Search Result 127, Processing Time 0.025 seconds

Fast Systemic Evaluation of Amylose and Protein Contents in Collected Rice Landraces Germplasm Using Near-Infrared Reflectance Spectroscopy (NIRS) (근적외선 분광분석기를 이용한 국내외 재래종 벼 유전자원의 아밀로스 및 단백질에 관한 대량 평가 체계구축)

  • Oh, Sejong;Lee, Myung Chul;Choi, Yu Mi;Lee, Sukyeung;Rauf, Muhammad;Chae, Byungsoo;Hyun, Do Yoon
    • Korean Journal of Plant Resources
    • /
    • v.30 no.4
    • /
    • pp.450-465
    • /
    • 2017
  • This study was conducted to characterize the amylose and protein contents of 4,948 rice landrace germplasm using the NIRS model developed in the previous study. The average amylose content of the germplasm was 20.39% and ranged between 3.97 and 37.13%. The amylose contents in the standard rice were 4.99, 18.63 and 20.55% in Sinseonchal, Chucheong and Goami, respectively. The average protein content was 8.17% and ranged from 5.20 to 17.45%. Protein contents in Sinseonchal, Chucheong and Goami were 6.824, 6.869 and 7.839%, respectively. A total of 62% germplasm were distributed between 20.06% and 27.02% in amylose content. Germplasm of 81.60% represented protein content of 6.78-9.75%. The distinguishable ranges of amylose contents according to origin were 16.58-20.06% in Korea, 20.06-23.25% in Japan, 23.25-27.02% in North Korea, and 27.02-37.13% in China. In the protein content, approximately 30% of Chinese resources ranged from 9.75 to 17.45%, whereas less than 10% were detected in other origin accessions. Fifty resources were selected with low and high amylose ranging from 3.97-6.66% and 30.41-37.13%, respectively. Similarly, fifty resources were selected with low and high protein ranging from 5.20-6.09% and 13.21-17.45%, respectively. Landraces with higher protein could be adapted to practical utilization of food sources.

Measurement of Absorbed Dose for High Energy Electron using $CaSO_4$:Tm-PTFE TLD ($CaSO_4$:Tm-PTFE TLD를 이용한 고에너지 전자선의 흡수선량 측정)

  • Park, Myeong-Hwan;Kim, Do-Sung;Doh, Sih-Hong;Kim, Wan;Kang, Hee-Dong
    • Journal of Sensor Science and Technology
    • /
    • v.10 no.5
    • /
    • pp.314-319
    • /
    • 2001
  • In this study, the highly sensitive $CaSO_4$:Tm-PTFE TLDs has been fabricated for the purpose of measurement of high energy electron. $CaSO_4$:Tm phosphor powder was mixed with polytetrafluoroethylene(PTFE) powder and moulded in a disk type(diameter 8.5mm, thickness $90mg/cm^2$) by cold pressing. The batch uniformities were average deviation 3.1%. The TLDs were applied to measurement of absorbed dose distribution for high energy electron, the ranges were determined to be $R_{100}=14.5mm$, $R_{50}=24.1mm$ and $R_p=31.8mm$, respectively. The beam flatness were 4.5% as the variation of dose relative to the central axis over the central 80% of the field size at a maximum dose depth in a plane perpendicular to the central axis.

  • PDF

HDR 비디오의 플리커 저감효과를 위한 톤 안정화 알고리즘 연구

  • Kim, Jeong-Tae;Lee, Hyeon-Gyu;Lee, Sang-Cheol
    • Information and Communications Magazine
    • /
    • v.33 no.9
    • /
    • pp.24-29
    • /
    • 2016
  • 영상의 화질 개선과 높은 대비를 얻기 위한 방법으로 최근 HDR(High Dynamic Range)영상을 디스플레이 장치에 매핑시키기 위한 톤매핑 기술이 널리 이용되고 있다. 하지만 단일프레임이 아닌 다중프레임으로 구성되어 있는 비디오에 이러한 톤매핑기술을 적용할 경우, 프레임 간 명암도 차이로 인하여 시각적으로 깜빡이는 현상인 플리커(Flicker)가 발생할 수 있으며, 이로 인해 사용자의 눈에 피로도를 증가시키고, 영상의 품질이 감소할 수 있다. 본 논문에서는 플리커 판별을 위해 영상의 명암도 측정법을 제안하여, 프레임별 명암값을 학습하기 위한 다양한 특징벡터를 정의한다. 학습된 SVM(Support Vector Machine) 분류기를 이용하여 플리커 발생 프레임을 선별하고 플리커 제거를 위한 톤 안정화 방법을 제안한다. 실험에서 제안한 방법을 통해 86.7%의 플리커를 검출하였으며, 프레임 간 톤 안정화 알고리즘의 최적화를 통해 플리커 발생빈도를 69.8% 감소시켰다.

STUDIES ON ANTITUMOR AGENTS PRODUCED BY STREPTOMYCES spp. ISOLATED IN KOREA

  • Ryeom, Kon;Kwon, Hyuk-Ku;Hong, Bum-Soo;Shin, Y.H.;Chang, S.J.
    • Proceedings of the Korean Society of Applied Pharmacology
    • /
    • 1995.04a
    • /
    • pp.61-61
    • /
    • 1995
  • 1993년 국내토양으로부터 분리동정된 Streptomyces속 균주중 항종양성이 우수한 균주 3주(DKM104, DKM117, DKM409)를 선정하고 이들을 대량 배양하여 종양억제인자를 분리하고 시험관내 종양세포 독성능 및 생체내 항암활성능과 이들 물질생산과 PLASMID DNA와의 관련성, $LD_{50}$등을 시험하여 새로운 항종양물질의 개발을 목적으로 하였다. 분리선별균주의 배양조건을 확립하였으며 배양여액을 국성이 적은 유기용매로부터 큰쪽으로 단계적으로 유효성분을 추출하여 Gel Chromatography를 이용하여 유효성분을 분획하였다. 시험관내 항종양능 시험은 MTT colorimetric검정법을 이용하여 $IC_{50}$값을 산정하였으며 생체내 항종양능은 마국의 NIC에서 권장하는 tumor panel system에 따랐다. 선정된 균주의 plasmid 분리는 alkalin lysis법을 채택하였으며 agarose gel electrophoresis로 plasmid profile을 시험하였다. Novobiocin등을 이용하여 Curing test를 시행하였고 독성실험은 $LD_{50}$량을 구해 항암효과 측정시에 Maximum dost로 투여하였고 최고용량을 기준으로 일정한 공비를 적응하여 3단계의 투여량을 설정하였다.(중략)

  • PDF

Development of a Smartphone-based Total Bilirubin Measuring System for Screening of Jaundice (황달 선별검사를 위한 스마트폰 기반의 총빌리루빈 측정시스템의 개발)

  • Kim, Won-Jung;Song, Eunji;Rhee, Joowon
    • Journal of Appropriate Technology
    • /
    • v.7 no.2
    • /
    • pp.206-210
    • /
    • 2021
  • Hyperbilirubinemia is the most common neonatal disease and is observed in about 80% of newborns worldwide in neonatal period within a week after birth. Untreated infant hyperbilirubinemia may lead to brain damage and even death, so it is very important to diagnose it quickly and accurately. In this study, a total bilirubin measurement system was developed that is portable and easy to use without pre-processing using a commercial smartphone. This system measures using the LED and camera of the smartphone without the need for additional devices, and because a small amount of blood is injected without pre-treatment, anyone can easily measure it in the field. In a comparative study with Cobas c111 results, accuracy meets CLIA guidelines with 94% (17/18) within ±0.4 mg/dL below 3 mg/dL and 98% within ±20% above 3 mg/dL (276/282). This system offers a simple, fast and accurate diagnosis for jaundice in infants and young children in low-resource settings.

A Study on the MDS Blasting Method Applicability by Test Field Construction (시험시공을 통한 MDS 발파공법의 현장 적용성에 관한 연구)

  • Bong-Hyun Lee;Sung-Oong Choi
    • Explosives and Blasting
    • /
    • v.42 no.1
    • /
    • pp.23-33
    • /
    • 2024
  • Recently, various techniques and patented methods on blasting operation are being newly developed. In this study, test construction of the MDS blasting method was performed, and the fragmentation size and the occurrence rate of rocks exceeding 300mm were measured and analyzed in comparing to normal blasting method. Test construction was performed three times each for normal and the MDS at the same bench for each round, and fragmentation size(P80) and occurrence rate of rocks exceeding 300mm(S30) were measured using digital image processing. A sieve bucket was also manufactured on-site to sort oversized rock particles from muck piles, and their weights and equivalents were measured to calculate actual values. As a result, the fragmentation size decreased of 21.0% with the MDS compared to normal, and 100-S30 decreased of 10.1%, with actual values decreasing of 7.6%. Although there were variations in blasting effects for each round due to differences in rock quality at site, overall, the MDS proved to be more effective compared to normal blasting method under equivalent conditions.

Diagnostic Utilization of Laser Fluorescence for Resin Infiltration in Primary Teeth (유치의 레진침투법을 위한 레이저 형광법의 진단적 활용)

  • Park, Soyoung;Jeong, Taesung;Kim, Jiyeon;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.46 no.3
    • /
    • pp.265-273
    • /
    • 2019
  • This study was performed to evaluate clinical use of laser fluorescence (LF) to identify early childhood caries lesions suitable for applying resin infiltration. 20 exfoliated primary molars with proximal caries were selected and cut buccolingually cross the central pit for regarding the mesial and distal surfaces respectively. 27 specimens corresponding to ICDAS code 1 and 2 were selected and the LF values were measured. When infiltrant resin was applied, double staining for microscopy detection has done simultaneously. Tooth samples were sliced with 0.7 mm thick. The maximum lesion depth, maximum penetration depth, and average penetration rate were measured from the confocal scanning laser microscope image. Pearson correlation analysis was performed. The intraclass correlation coefficient of LF values shows excellent agreement. LF values had positive correlation with penetration rate, but not lesion depth and penetration depth. Significant correlation between LF readings and penetration rate was verified in deep enamel caries and dentin caries except shallow enamel caries. Infiltrant resin could penetrate with a higher rate and LF values could be increased in more active caries lesions. In assessing radiologically similar caries lesion, laser fluorescence might be useful for identifying caries activity.

Region Query Reconstruction Method Using Trie-Structured Quad Tree in USN Middleware (USN 미들웨어에서 트라이 구조 쿼드 트리를 이용한 영역 질의 재구성 기법)

  • Cho, Sook-Kyoung;Jeong, Mi-Young;Jung, Hyun-Meen;Kim, Jong-Hoon
    • Journal of Korea Spatial Information System Society
    • /
    • v.10 no.1
    • /
    • pp.15-28
    • /
    • 2008
  • In ubiquitous sensor networks(USN) environment, it is essential to process region query for user-demand services. Using R-tree is a preferred technique to process region query for in-network query environment. In USN environment, USN middleware must select sensors that transfers region query with accuracy because the lifetime of sensors is that of whole sensor networks. When R-tree is used, however, it blindly passes the region query including non-existent sensors where MBR(Minimum Boundary Rectangle) of R-tree is Intersected by region of query. To solve in this problem, we propose a reconstruction of region query method which is a trie-structured Quad tree in the base station that includes sensors in region of query select with accuracy. We observed that the proposed method delays response time than R-tree, but is useful for reducing communication cost and energy consumption.

  • PDF

Design of Standard Value Intracranial Translucency of Fetus in Early Pregnancy Using Ultrasound (초음파를 이용한 임신초기 태아의 두개내투명대 표준치 제시)

  • Yang, Sung-Hee;Kim, Changsoo
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.131-137
    • /
    • 2021
  • The purpose of this study was to present the reference value of the intracranial translucency(IT) of the fetus using the mid sagittal plane of the post brain in the early pregnancy ultrasound screening test and to find the clinical significance. From August 2018 to February 2020, the IT of 1529 singleton fetus whose crown lump length were 40.6 mm to 78.3 mm in length among the mothers undergoing regular checkups at Hospital I were measured and analyzed retrospectively. As the crown lump length increased, the IT showed a 54.3% explanatory power and tended to increase(p<0.001). In addition, through frequency analysis, the standard value for the percentile of the IT by gestational weeks was calculated. As a result, it was possible to establish a standard value for Koreans with an IT, and it will be usefully applied as an auxiliary screening test for spina bifida in the evaluation of fetal post brain in early pregnancy.

저점착 코팅의 접합특성 평가방법 개발

  • Kim, Yu-Seop;Jo, Hui-Jae;Lee, Hak-Yeong;Jeong, Yong-Chan;Lee, Su-Yeol
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.42.2-42.2
    • /
    • 2018
  • 신도시 및 대규모 도시 개발이 진행됨에 따라 안정적이고 효율적인 전력 공급을 위해 다수의 지상 배전함이 설치되고 있으며, 이에 따라 불법 광고물 및 스티커의 부착으로 인한 문제가 발생하고 있다. 이를 해결하기 위하여 여러 기관 및 산업체에서는 부착 방지용 코팅 도료 및 시트에 대하여 다양한 연구개발을 진행하고 있으며, 현장에 적용 된 다수의 제품이 존재한다. 하지만 현재 대부분의 제품들은 약 1년 정도의 시간이 지나면 부착 방지 기능을 상실하며, 도료와 기판 또는 시트와 기판 사이의 박리가 일어나 도시의 미관을 더욱 해치는 결과를 초래하고 있다. 이러한 원인으로는 부착력(Peel resistance, N/cm)을 측정하는 기존의 제시된 방법(KS T 1028, Peel test)으로는 정확한 측정이 어렵기 때문에 제품 선별에 어려움이 있다. 일반 기판의 경우 규격에서 요구하는 각도($90^{\circ}$, $180^{\circ}$)가 잘 유지되어 정밀한 부착력 측정이 가능하지만, 저점착 기능성 코팅소재(Anti-adhesion coating)의 경우 부착 자체가 어렵기 때문에 요구 각도를 유지하기 어려워 정밀한 측정을 할 수 없다. 이러한 문제점들을 해결하고자 압입자(Probe)를 이용한 새로운 평가 장치와 방법(Tack test)을 개발 및 제시하였다. 평가 지표로는 최대 점착력(Adhesive force, N), 최대 점착력일 때 점착제가 늘어난 총 길이(Extension of adhesive, mm), 탈착 에너지(Energy, J)가 있으며, 인가하는 힘(N)이 커질수록, 탈착 속도(Velocity)가 빨라질수록 평가 지표 모두 값이 상승하는 경향성을 보인다. 각 시험방법(Peel test, Tack test)에 대한 테이프류 점착제와 기판과의 결합이 끊어지는(Debonding, 탈착) 메커니즘(Mechanism)은 점착제 기공(Cavity)의 형성, 결합이 끊어지는 힘(Debonding force, N), 힘의 평형(Force balance)로 설명 가능하며, 상호간의 관계성을 도출한다. 이와 같은 평가 지표를 활용하여 저점착 기능성 코팅소재에 대해 정밀한 평가를 하는 것으로, 향후 개발될 다양한 제품에 대한 성능 분별력을 높이고, 현장에 적용 될 제품들의 성능을 끌어 올려 기존에 발생한 다양한 문제점들을 해결 할 수 있다.

  • PDF