• Title/Summary/Keyword: 측정값

Search Result 14,436, Processing Time 0.041 seconds

Realization for Automatic Stock Cubic Measuring and Distributing Management Embedded System with 3D Ultrasonic Sensing (3D 초음파센싱 자동물류부피측정 및 분류관리 임베디드시스템 구현)

  • Lee, Eun-Eok;Ryu, Kwang-Rryol;Hur, Chang-Wu
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.10a
    • /
    • pp.285-288
    • /
    • 2007
  • A realization for automatic stock cubic measuring and distributing management embedded system with 3 dimensional ultrasonic sensing is presented in this paper. The height and width of cubic are measured by comparing the 3 values from 3 ultrasonic sensors with reference when an object is passing the conveyer and length is calculated by the passing time and velocity, compensate cubic values for error to vary with the environment temperature, and reduce the error by averaging the sensing data not to be right posture of object. The system enables to classify and load a packed stocks at the store and transportation practically based on the rectangular hexahedral objects.

  • PDF

석영의 파동소광을 이용한 포천-기산리 일대의 화강암 변형의 정량화

  • 정원석;윤현수;나기창
    • Proceedings of the Mineralogical Society of Korea Conference
    • /
    • 2003.05a
    • /
    • pp.80-80
    • /
    • 2003
  • 포천-기산리 일대에 분포하는 쥬라기의 대보화강암류의 변형정도를 결정하기 위해 석영의 파동소광의 강도(IWE : Intensity of Wavy Extinction)를 편광현미경, 디지털 카메라, NIH Image로 측정하였다. 파동소광이 나타나는 석영입자의 한 부분이 편광현미경 상에서 최대 소광이 될 때 IWE를 측정하고, 이 때 나타나는 파동소광의 아입자경계에 수직한 방향으로 측정을 시도하였다 본 연구에 사용된 NIH Image는 파동소광을 보여주는 각 부분의 광도를 256단계의 흑백 농담변화로 나타낼 수 있다. 이를 이용하여 측정 길이에 대한 농담변화로 IWE를 구하였다. 이렇게 획득한 IWE를 5$^{\circ}$ 단위로 묶어 돗수분포표로 처리하였으며, 자료의 분포특성상 히스토그램의 최빈값과 중간값 사이의 중간값을 그 암석의 대표 IWE로 정의하였다. 이를 다시 5단계의 변형대(무변형, 저변형, 중변형, 고변형, 최고변형)와 각각의 변형지수(D1, D2, D3, D4, D5)로 묶었다. 본 연구지역에 분포하는 화강암류는 흑운모화강암(Gb), 동부의 석류석흑운모화강암(Ggb) 그리고 북부의 복운모화강암(Gtm)으로 구성되어 있는 바 본 연구에는 크게 포천읍을 기준으로 서부에 분포하는 Gb와 동부에 분포하는 Ggb에서 파동소광의 강도 측정이 이루어 졌다. 연구결과 Gb는 D2 이하의 낮은 변형도가 나타났고, Ggb는 D3이상의 고변형이 나타나, 전반적으로 조사지역의 북서부에서 남동부로 갈수록 변형도가 증가하는 양상을 보여주었다.

  • PDF

Indoor position finder using Wi-Fi (Wi-Fi를 이용한 실내 위치 측정)

  • Park, Jong-Hyun;Kim, Seong-Guk;Oh, Hee-Su;Lee, Sang-Hee;Lee, Seong-Yeul;Hwang, Young-Sup
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2015.10a
    • /
    • pp.362-365
    • /
    • 2015
  • 우리나라는 현재 코엑스, 백화점 같은 대형 건물들이 늘어나고 있다. 대형 건물은 실내 구조가 복잡해서 방문하는 사람들이 원하는 길을 찾기 어렵다. 기존 실외에서 길을 찾아주는 네비게이션의 발달은 단말기와 스마트폰의 발달과 함께 성장하였고, 모든 사람들이 사용할 수 있는 대중적인 서비스다. 하지만 기존 네비게이션에 위치 측정 방법인 위성 GPS신호는 실내에서는 사용이 불가해 실내 위치 측정을 위해 Wi-Fi, Beacon, Magnetic Field등 다른 기술을 사용하여 실내 위치 측정을 해야 한다. 그중에서도 이미 설치되어 있는 것을 사용하기 위해 Wi-Fi의 신호 값인 RSS값을 활용하였고, 일정하지 앉은 RSS값을 Kalman Filter와 EH Filter로 보정하여 정확한 실내 위치 측정이 된다는 것을 실험을 통해 보였다.

고방열 세라믹 기판을 이용한 LED 방열 특성에 대한 고찰

  • Kim, Min-Seon;Jo, Hyeon-Min;Go, Sang-Gi;Jang, Min-Gyeong;Lee, Geon-Hyeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.127-127
    • /
    • 2010
  • 최근 Light-emitting diodes (LEDs: 발광다이오드) 디바이스의 고휘도, 저전력, 긴 수명, 다양한 색연출 가능, 친환경 소자 등의 장점으로 LED 디바이스가 flat panel display(FPD)의 back light unit (BLU) 를 비롯해 실내 외 조명과 자동차 전조등 분야 이외에도 의료, 인테리어 사업을 비롯한 각종 전자 통신 기기의 정보 처리 기기의 표시소자 등, 여러 제품 군에 적용되는 가운데 큰 관심을 받고 있다. 하지만 이러한 여러 가지 장점에도 불구하고 LED 모듈에서의 junction temperature가 높은 방열 특성이 나쁘다는 단점은 아직 해결되지 않고 있는 실정이다. LED 소자 모듈에서의 junction temperature가 높을 경우 소비되는 에너지가 많을 뿐만 아니라 LED 소자의 발광효율이 떨어지고 수명이 급격히 저하 되어, 결국에는 신뢰성 특성이 현저히 저하 되는 결과가 초래되기 때문이다. 따라서 본 논문에서는 LED 디바이스의 열저항을 낮추기 위해 고방열 세라믹 기판을 이용해 LED 디바이스의 방열 특성을 향상시킨 결과를 제시한다. 고방열 세라믹 기판을 제작하여 LED 칩을 실장시킨 다음 LED 열저항 특성을 측정하였다. 이때 고방열 세라믹 기판은 Al2O3와 AlN이 사용되었으며 제작한 세라믹 기판의 강도, 표면 roughness, 미세구조 등을 살펴보고 이 기판들의 열전도도를 측정하였다. 제작 공정방법에 따라 세라믹 기판의 미세구조를 비롯한 기계적, 열적 특성이 현저히 변하였으며 이때 LED 칩을 실장 하여 측정한 열저항 특성 값도 함께 변하였다. Al2O3의 열저항 값은 3.003 K/W 으로 측정 되었으며, AlN의 열저항 값은 3.003k/W 으로 측정되었다.

  • PDF

Simultaneous Sensing of Failure and Strain in Composites Using Optical Fiber Sensors (광섬유 센서를 이용한 복합재의 파손 및 번형률 동시 측정)

  • 방형준;강현규;홍창선;김천곤
    • Composites Research
    • /
    • v.14 no.5
    • /
    • pp.12-19
    • /
    • 2001
  • In aircraft composite structures, structural defects such as matrix cracks, delaminations and fiber breakages are hard to detect if they are breaking out in operating condition. Therefore, to assure the structural integrity, it is desirable to perform the real-time health monitoring of the structures. In this study, a fiber optic sensor was applied to the composite beams to monitor failure and strain in real-time. To detect the failure signal and strain simultaneously, laser diode and ASE broadband source were applied in a single EFPI sensor using wavelength division multiplexer. Short time courier transform and wavelet transform were used to characterize the failure signal and to determine the moment of failure. And the strain measured by AEFPI was compared with the that of strain gage. From the result of the tensile test, strain measured by the AEFPI agreed with the value of electric strain gage and the failure detection system could detect the moment of failure with high sensitivity to recognize the onset of micro-crack failure signal.

  • PDF

Monte Carlo Simulation for the Measurement of Entrance Skin Dose on Newborn and Infants (영·유아의 입사피부선량 측정을 위한 몬테카를로 시뮬레이션)

  • Kim, Sang-Tae
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.6
    • /
    • pp.346-352
    • /
    • 2012
  • Radiation dose estimation on the newborn and infants during radiation examinations, unlike for the adults, is not actively being progressed. Therefore, as an index to present exposure dose during radiation examinations on newborn and infants, entrance skin dose was measured, and the result was compared with results of monte carlo simulation to raise reproducibility of entrance skin dose measurement, and it was proved that various geometry implementation was possible. The resulting values through monte carlo simulation was estimated using normalization factors for entrance skin dose to calibrate radiation dose and then normalized to a unit X ray radiation field size. Average entrance skin dose per one time exposure was $78.41{\mu}Gy$ and the percentage error between measurement by dosimeter and by monte carlo simulation was found to be -4.77%. Entrance skin dose assessment by monte carlo simulation provides possible alternative method in difficult entrance skin dose estimation for the newborn and infants who visit hospital for actual diagnosis.

Compression of Medical Examination Data Based on Modified Gamma-Coding (수정된 감마 코딩 기반 의료 검진 데이터 압축)

  • Ku, Dong Youn;Park, Jae Wook;Lee, Yong Kyu
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.2
    • /
    • pp.133-142
    • /
    • 2014
  • According to the development of medical information systems, shortened examination time per patient could increase the number of treatments, resulting in the rapid growth of the amount of medical data. Studies on how to efficiently compress and store medical text data of increasing patients are in progress. However, previous methods have the shortcoming of compressing medical text data as it is, resulting in low compression rate. This research tries to overcome the problem by using the gamma coding method which enables compression in bit unit. We propose a new compression scheme which encodes the deviations between measured values and normal range values. Furthermore, we suggest to use the previous value with the least deviation from the measurement as the standard value to encode that deviation. Even though the suggested methods are simple, they have high compression rates. Through performance evaluation, we show that the suggested methods are more efficient than the previous methods.

Signal-to-noise Ratio in Time- and Frequency-domain Photoacoustic Measurements by Different Frequency Filtering (주파수 필터링 함수에 따른 시간 및 주파수 영역 광음향 측정에 대한 신호 대 잡음비 분석)

  • Kang, DongYel
    • Korean Journal of Optics and Photonics
    • /
    • v.30 no.2
    • /
    • pp.48-58
    • /
    • 2019
  • We investigate the signal-to-noise ratios (SNRs) of time-domain (i.e. pulsed illumination) and frequency-domain (i.e. chirped illumination) photoacoustic signals measured by a spherically focused ultrasound transducer for spherical absorbers. The simulation results show that the time-domain photoacoustic SNR is higher than that of frequency-domain photoacoustic signals, as reported in the previous literature. We understand the reason for this SNR gap between the two measurement modes by analyzing photoacoustic-signal spectra, considering the incident beam energy controlled by the maximum permissible exposure. As the result of this approach, we find that filtering off the DC term in the chirped signal's spectrum improves frequency-domain photoacoustic SNRs by up to approximately 5 dB. In particular, it is observed that photoacoustic SNRs are highly sensitive to an upper-frequency value of frequency filtering functions, and the optimal upper-frequency values maximizing the SNR are different in time- and frequency-domain photoacoustic measurements.

New Method of Volume Measurement for Reference Weights of a Pressure Balance Using a Gas Pycnometer (기체용적계를 이용한 분동식 압력계용 기준분동의 새로운 부피측정 방법)

  • Lee, Yong Jae;Lee, Woo Gab;Mohammed, Mohammed Abdurahman;Park, Yon-Kyu;Oh, Chae Yoon
    • Journal of the Korean Vacuum Society
    • /
    • v.22 no.5
    • /
    • pp.231-237
    • /
    • 2013
  • New method of volume measurement for reference weights of a pressure balance using a gas pycnometer is proposed. The result of volume measurement of proposed method shows the uncertainties of approximately 0.2% at the level of confidence of 95% for reference weights in the ranges of 1 kg, 2 kg, and 5 kg. This measuring system consists of a sample chamber, an expansion chamber, a precision pressure gage, a precison thermometer, a vacuum pump, and helium as a medium gas. The measurement principle of this proposed method is based on Boyle's law. This method will contribute a reliability of the volume measurements of reference weights for a pressure balance to the national measurement standard.

진공펌프 배기속도 측정 방식에 따른 구조적 오차 및 보정

  • In, Sang-Ryeol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.169-169
    • /
    • 2011
  • 진공펌프의 성능을 나타내는 여러 파라미터가 있지만 가장 중요한 성능지표는 역시 배기속도라고 할 수 있다. 배기속도는 물리적으로 체적유량(volume flow rate, L/s 또는 m3/hr) 즉 단위시간당 펌프 흡기구에 들어오는 기체의 체적을 가리킨다. 펌프 흡기구 단면을 지나가는 체적을 직접 측정하는 것은 거의 불가능하므로 진공 전문가들은 흡기구로 들어가는 기체 유량(flow rate, mbar${\cdot}$L/s 또는 Pa${\cdot}$m3/s)과 흡기구 압력(mbar 또는 Pa)을 측정한 후 유량을 압력으로 나누어 주는 방식으로 배기속도를 측정한다. 유량은 표면 기체 방출을 고려하더라도 실용적인 측면에서 보면 위치에 상관없이 불변하는 값으로 볼 수 있어서 유량을 어떻게 정밀하게 잴 것인가 하는 방법만 있으면 편리한 위치에서 측정하면 된다. 반면에 압력을 정밀하게 측정하는 방식은 확립되어 있지만 막상 어디서 측정하는 것이 옳은가 하는 것은 의외로 쉽지 않다. 펌프의 배기속도를 측정하는 상황을 몇 가지로 가정해 보면, 규격에 입각한 표준용기에 달아 정식으로 재는 것, 게이지가 부착된 마구리판을 달고 간이로 재는 것, 펌프가 사용되고 있는 시스템 현장에서 재는 것이 있을 수 있고 펌프가 달려 있는 상태도 직접 용기에 달거나, 도관 또는 어댑터 및 밸브를 통해 달리는 경우가 있다. 앞에서 펌프 배기속도 계산 시 사용하는 흡기구 압력이란 엄밀히 말하면 흡기구를 바라보는 방향으로 가해지는 압력을 말하는데 이는 진공 게이지를 펌프 흡기구 면에서 상류를 향하도록 놓을 때 얻을 수 있는 값으로 막상 실행하는 것은 어렵다. 표준용기의 구조는 진공 게이지를 특정 위치에 달 때 마치 흡기구 면에 놓인 게이지처럼 흡기구 압력을 정확하게 측정할 수 있도록 고안된 것이지만 때에 따라서는 여러 변형된 측정 방식을 사용할 수밖에 없는 상황이 만들어지므로 어떤 보정을 거치면 올바른 배기속도 값을 구할 수 있는지 살펴볼 필요가 있다.

  • PDF