The tracking radars in NARO space center are precious, long-range tracking systems for tracking the launch vehicle (KSLV-1) and transmitting TSPI (Time, Space and Position Information) data to MCC (Mission Control Center). Because TSPI data from tracking radars to MCC are important information for the launch mission and flight safety control, TSPI data are required to be more accurate. In this paper, we analyzed theoretically the required specification of the random noise error in tracking radar and verified the real random noise error. In this analysis, we evaluated the TSPI data of several flight tests performed in NARO space center.
The measurement of RTT (Round Trip Time) can be used for the analysis of Internet congestion. However, simple measuring of RTT which measures only hun around time of a packet can not infer a packet forward/backward delay variation. In this thesis, we present a new algorithm which can be used for the estimation of forward/backward delay variation of packets. These delay variations are implication of network congestion state. In this algorithm, the reference forward/backward delay can be determined based on the minimum RTT value. The delay variation of each packet can be calculated by comparing reference delay with the packet delay. We verified our proposed algorithm by NS-2 simulation and delay measuring in a real network.
Ku, Ja-Hun;Kim, Jong-Dae;Kim, Yu-Seop;Park, Chan-Young;Lee, Wan-Yeon;Song, Hae-Jung
Proceedings of the Korean Information Science Society Conference
/
2010.06c
/
pp.221-225
/
2010
본 연구에서는 제한된 온도 영역에서 보통 정밀 온도 측정 소자로 많이 쓰이는 NTC 써미스터를 사용하여 전압 분배 회로(voltage divider circuits)를 구성하였다. 분압 저항이 온도측정 해상도에 미치는 영향을 분석하고, 회로의 분압 저항을 결정하는 방법으로서 측정하고자 하는 온도 구간의 최대 온도와 최저 온도의 NTC 써미스터 저항 값을 조화평균을 사용하여 분압 저항(divider resistance)으로 사용하였다. 선택한 분압 저항이 이상적인 저항인지에 대하여 조화평균으로 계산한 분압 저항과 대조군 저항으로 전압 분배 회로를 병렬로 구성하였다. 센서들을 항온조 넣어 설정온도($50^{\circ}C$, $70^{\circ}C$, $90^{\circ}C$)에서 각각의 온도를 측정한 후 측정 데이터의 표준편차를 구하여 평균 온도 분해능을 비교 하는 실험을 하였다. 실험결과 측정온도 구간의 최대 온도와 최소 온도에서의 NTC 써미스터 저항 값을 조화평균으로 계산한 분압 저항 값이 대조군 저항에 비해 설정온도에서 보다 높은 평균 온도 분해능(sensing resolution)을 보였다.
Journal of the Korea institute for structural maintenance and inspection
/
v.13
no.5
s.57
/
pp.101-108
/
2009
Mathematical basis of interpretation of data from nondestructive evaluation (NDE) methods in condition assessment of structures is presented. In structural inspection with NDE methods, NDE data are not directly used for the condition assessment. Instead, NDE data must be interpreted as condition of inspected element. Correct assessments of conditions depend on many factors such as the inaccuracy and the variability in NDE measurements and the uncertainty in correlation between attributes (what is measured) and conditions (what is sought in the inspection). A full description of the performance of NDE methods considers the relation of test data to conditions of elements. The quality of the test itself is important, but equally important is the interpretation that occurs after the test. The effects of variability in test data and uncertainty in correlations of attributes and conditions are presented in three examples of field testing methods.
Proceedings of the Korea Information Processing Society Conference
/
2011.11a
/
pp.1243-1247
/
2011
센서 네트워크는 많은 수의 센서들로 구성되며 물질세계와 상호작용하여 실시간 감시를 할 수 있는 큰 규모의 네트워크이다. 현실 세계의 물리적 변화를 지속적으로 감시하기 위하여 센서 네트워크에 속해 있는 각 센서들은 주기적으로 측정값을 읽어서 기지국(base station)에 전달하는 기능을 수행한다. 이러한 경우, 각 센서들의 지속적인 통신에 따른 에너지 낭비가 발생하여 센서 네트워크 전체의 수명을 단축시키게 된다. 따라서 데이터 모니터링에 있어서 예측을 통한 근사 데이터 수집을 통해 센서 네트워크의 수명을 연장하고자 하는 연구들이 진행되고 있다. 그러나 현재의 예측을 통한 근사 데이터 수집은 측정값의 변화가 클수록 예측 모델의 갱신이 잦다. 따라서 본 논문에서는 지연 갱신을 이용한 효율적인 예측 모델 갱신 기법을 제안한다. 제안된 기법에서는 예측이 실패하였을 경우 즉시 예측 모델을 갱신하는 대신 문제가 되는 구간의 측정값들을 지연, 근사화하여 전송함으로써 예측 모델의 잦은 갱신을 방지할 수 있다.
The performance of an electrometer directly affects on the accuracy and precision in radiation dosimetry. This study is to list of the quality control for maintaining performance and to perform evaluation tests of an electrometer. Performance tests selected include proper polarizing voltages, warm-up and equalization time, leakages, long-term stability, linearity, and effect of ambient conditions. An electrometer connected with a rigid stem ionization chamber was evaluated with a Strontium-90 check device. Bias voltage was measured directly on the input socket. Equalization time is the time required for reaching threshold of charged state after the power is on or the bias voltage is changed. Pre- and post-signal leakages are defined as the accumulation of signal with no exposure and after exposure, respectively. Over three months period, the electrometer's long-term stability was measured by comparison of the temperature-pressure corrected readings. Linearity was expressed as the deviation of readings from multiple short exposures from one continuous exposure. Effect of ambient conditions was expressed as the zero drift of the electrometer over 17-34$^{\circ}C$ temperature ranges. For two nominal values, 300 and 500 volts, measured voltages were lower by 2.5 and 5.8%, respectively. The warm-up time, 20 minutes, was longer than the lamp time by 9 minutes and the equalization time was less than 1 minute. Without exposure, the zero-drift was 0.002 scale-unit in 15 minutes and the leakage after 10 minutes exposure was minimal. The IQ-4 was stable over 99.4% for three-month periods. Deviation from the linearity was 0.9% for measurement scale, 0.000-9.991. Over 17-34$^{\circ}C$ temperature range, the zero-drift was minimal, less than 0.2%. For a clinically-used electrometer, a list for the basic peformance evaluations is proposed. By running this program, the measurement error using an electrometer can be reduced and in turn the improvement in accuracy and precision of radiation dosimetry can be achieved.
Marginal and internal fit is an important part of the longevity of dental restorations. The purpose of this study was to analysis the marginal and internal fit of zirconia core by dental CAD/CAM system using innovative and non-destructive methods such as optical coherence tomography(OCT) and compare with conventional method such as silicone replica technique(SRT). Ten dental stone models of abutment of maxillary right central incisal were manufactured and scanned. Ten zirconia cores were fabricated with commercial CAD/CAM system. To measure the marginal and internal fit of each sample, five point of fitness were measured using 2 different methods(OCT and SRT). Statistical analysis was performed using independent sample t-test(${\alpha}$=0.05). OCT and SRT groups were not significantly different(P>0.05). By this results, analysis the fitness of dental restorations using OCT were acceptable measuring method.
In general, acid rain is unbuffered solution with low ionic strength and high resistance. Therefore during the pH measurement of acid rain, error can be occurred due to the liquid junction potential difference between the sample and the standard solution. Actually the average conductivity of rain in Taeduk Science Town during 1998 is 12.8 ${\mu}S/cm$, while that of pH standmd solutions is about 5,980 ${\mu}S/cm$. There is a large difference in ionic strength. To compensate the bias due to residual liquid junction potentials, a quality control standard(QCS) of dilute sulfuric acid, which has the conductivity and pH values simikw to rain, was prepared. The pH of QCS solution was determined using the hydrogen electrode system without liquid junction, and compensation has been made for the bias terms by performing the pH measurements with glass electrode. On the basis of this compensation method, the pH vaiues of rain in Taeduk Science Town during 1998 were measured.
One of recent topics in the case of hepatits B virus(HVB) is the value of hepatitis B surface antigen(HBsAg) concentration as a prognostic maker. We developed uantitative method of rapid immunochromatographic assay(ICA) kit for HBsAg using computer image analysis (CIA) for the purpose of home diagnosis. uantitative ICA using CIA demonstrated integrated optical density(IOD) values proportional to log of reference HBsAg concentrations in the range of 2-200 ng/mL and enzyme-linked immunosorbent assay(ELISA) demonstrated the same in the range of 0.1-100 ng/mL however the test results with sample sear showed the same concentration on both kits. Furthermore repeated tests with the same samples revealed that this quantitative ICA using CIA would be reproducible and coefficient of variation(CV) of the results was 1.38~6.30%.
Proceedings of the Korea Crystallographic Association Conference
/
2002.11a
/
pp.40-41
/
2002
차세대 반도체 및 나노소자 산업에 대한 국제적 기술은 고밀도 직접화의 추세에 따라서 .게이트 산화막의 두께가 급속히 작아지는 추세이다. 지금까지 이산화규소(A1₂O₃)가 게이트 산화막으로 주로 사용되어 왔으나 점차 SiON 혹은 high k 박막으로 바뀌고 있다. 본 연구에서는 차세대 반도체 소자에 사용될 게이트 산화막 물질인 SiON 박막과 Al₂O₃박막에 대한 SE(Spectroscopic Ellipsometry)분석 모델을 확립하였고, SE 측정결과를 TEM, MEIS, XRR의 결과들과 비교하였다. SiON 박막의 굴절률 값은 Si₃N₄와 SiO₂가 물리적으로 혼합되어 있다고 가정하여 Bruggeman effective medium approximation을 사용하여 구하였다. 동일한 시료를 절단하여 TEM, MEIS, 그리고 XRR에 의하여 SiON 박막의 두께를 측정하였으며, 그 결과 SE와 XRR에 의해 얻어진 박막두께가 TEM과 MEIS의 결과 값보다 약 0.5 nm 크게 주어짐을 알 수 있었다(Table 1 참조). 본 연구결과는 비파괴적이며 비접촉식 측정방법인 SE가 2~4nm 두께의 초미세 SiON 박막의 두께와 N 농도의 상대적 값을 빠르고 쉽게 구할 수 있는 유용한 측정방법 임을 보여주었다. 기존의 게이트 산화물인 SiO₂를 대체할 후보 물질들 중의 하나인 A1₂O₃의 유전함수를 구하기 위하여 8 inch, p-type 실리콘 기판 위에 성장된 5 nm, 10 nm, 및 20 nm 두께의 A1₂O₃ 박막의 유전함수와 두께를 측정하였다. 이 시료들에 대한 SE data는 vacuum-UV spectroscopic ellipsometer를 사용하여 세 개의 입사각에서 0.75 eV에서 8.75 eV까지 0.05 eV 간격으로 측정되었다. A1₂O₃ 박막의 유전함수와 두께를 얻기 위하여 공기층/A1₂O₃ 박막/Si 기판으로 구성된 3상계 모델을 사용하였다. Si 기판에 대한 복소 유전함수는 문헌상의 값(1)을 사용하였고, A1₂O₃ 박막의 유전함수는 5개의 미지상수를 갖는 Tauc- Lorentz(TL) 분산함수(2)를 사용하였다. A1₂O₃ 박막의 경우 두께가 증가함에 따라서 굴절률이 커짐을 알 수 있었다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.