• Title/Summary/Keyword: 측정(measurement)

Search Result 20,142, Processing Time 0.049 seconds

Assessment of Adsorption Capacity of Mushroom Compost in AMD Treatment Systems (광산배수 자연정화시설 내 버섯퇴비의 중금속 흡착능력 평가)

  • Yong, Bo-Young;Cho, Dong-Wan;Jeong, Jin-Woong;Lim, Gil-Jae;Ji, Sang-Woo;Ahn, Joo-Sung;Song, Ho-Cheol
    • Economic and Environmental Geology
    • /
    • v.43 no.1
    • /
    • pp.13-20
    • /
    • 2010
  • Acid mine drainage (AMD) from abandoned mine sites typically has low pH and contains high level of various heavy metals, aggravating ground- and surface water qualities and neighboring environments. This study investigated removal of heavy metals in a biological treatment system, mainly focusing on the removal by adsorption on a substrate material. Bench-scale batch experiments were performed with a mushroom compost to evaluate the adsorption characteristics of heavy metals leached out from a mine tailing sample and the role of SRB in the overall removal process. In addition, adsorption experiments were perform using an artificial AMD sample containing $Cd^{2+}$, $Cu^{2+}$, $Pb^{2+}$ and $Zn^{2+}$ to assess adsorption capacity of the mushroom compost. The results indicated Mn leached out from mine tailing was not subject to microbial stabilization or adsorption onto mushroom compost while microbially mediated stabilization played an important role in the removal of Zn. Fe leaching significantly increased in the presence of microbes as compared to autoclaved samples, and this was attributed to dissolution of Fe minerals in the mine tailing in a response to the depletion of $Fe^{3+}$ by iron reduction bacteria. Measurement of oxidation reduction potential (ORP) and pH indicated the reactive mixture maintained reducing condition and moderate pH during the reaction. The results of the adsorption experiments involving artificial AMD sample indicated adsorption removal efficiency was greater than 90% at pH 6 condition, but it decreased at pH 3 condition.

Morphological comparison between aquaculture and natural populations for development of the new varieties of Ecklonia cava (감태(Ecklonia cava Kjellman) 신품종 개발을 위한 양식 개체군과 자연 개체군의 형태 비교)

  • Kim, Seung-Oh;Heo, Jin Seok;Hwang, Eun Kyoung;Hwang, Mi Sook;Lee, Sang-Rae;Oak, Jung Hyun
    • Korean Journal of Environmental Biology
    • /
    • v.37 no.4
    • /
    • pp.707-718
    • /
    • 2019
  • Ecklonia cava Kjellman, which has recently gained popularity due to the spread of farming techniques, is expected to be developed in various varieties in the future. There exist increased needs for research on the basis of natural populations and inter-regional morphological variations. We compared the morphology of the aquaculture and natural populations from 16 coastal areas in Korea. The 18 traits found suitable for distinguishing varieties were selected from 14 measurement traits and 4 ratios related to the main morphology and characteristics of primary blade, secondary blade, and stipe. In the cluster analysis, Janggil (E4) and Sorok (S7) showed significant differences from those of the same coastal region. Two groups, including Suyou (Q6, Q8, and Q10) which was the second year of farming, of the rest of the populations from East sea and southern coast were distinguished. Three populations of Jeju were divided into a regional group. In the principal component analysis (PCA), a large number of populations from East sea and Southern coast appeared in the center with aquaculture populations. PC1 and PC2 associated with traits of secondary blade index, stipe length and diameter, stipe length/primary blade length, primary blade length and width, secondary blade number, secondary blade length and width, divided E4, S7 and populations of Jeju region. As a result, the 18 characters of this study were found to be useful as criteria for discrimination of populations with significant differences in each coastal region, and these populations were expected to be candidates for new varieties.

Analysis of Correlation with Cross Sectional Area of Flow and Flow Rate Variation of Discharge Measurement Point in the Upper Stream of Seomjin River (섬진강상류 유량측정지점의 유수단면적과 유량변화에 따른 상관관계 분석)

  • Song, KwangDuck;Kim, KapSoon;Lee, DongJin;Ham, SangIn;Kim, DaeYoung;Oh, TaeYoun;Lee, JaeChoon;Lim, ByungJin
    • Korean Journal of Ecology and Environment
    • /
    • v.46 no.1
    • /
    • pp.94-102
    • /
    • 2013
  • This study was carried out to determine the variation of the water level and crosssection area for investigating changes of stream foreland, and to determine the correlation between the average flow velocity and cross-section area so as to understand the hydrological characteristics of the stream. The slope of the cross-sectional area was changed in water levels of 0.6~1.0 m and 1.8~2.0 m. The first change occurred in the low-water level season, and the second change occurred in the high-water level seasons. It is assumed that the changes occurred due to the geological transfigure. The correlation between the cross-sectional area and the average flow velocity was 0.22~0.86 in the exponential equation and 0.20~0.87 in the linear equation. The low water level had a higher correlation than the high water level, and free weirs in the upper stream showed a very low correlation. Therefore, this study provides novel information for the management of water quality in the riverside, using correlation equations of the water level and flow velocity with the cross section area.

Quality of Life Changes in Patients Admitted to the Hospice Unit (호스피스 병동 입원 환자의 삶의 질 변화)

  • Park, Theresia;Song, Hae-Hiang;Seo, In-Ok;Cho, Young-Yee;Park, Myung-Hee;Heo, Jeong-Hee;Kim, Eun-Kyung;Park, Sun-Ju;Ra, Jeong-Ran
    • Journal of Hospice and Palliative Care
    • /
    • v.3 no.1
    • /
    • pp.18-27
    • /
    • 2000
  • Purpose : This study aims to find out the quality of life of patients admitted to the hospice unit at Kangnam St. Mary's Hospital, at admission and after weeks hospice service and to assess the effects of hospice service on the quality of life of terminal cancer patients. Methods : This study subjects were 100 patients admitted to the hospice unit at Kangnam St. Mary's Hospital, Catholic University between October 1999 and March 2000, and their primary caregivers. Quality of life data were collected using a questionnaire revised by the authors and were analyzed by means of repeated measures ANOVA. Results : 1) Patient's quality of life as perceived by the primary caregiver was significantly improved and the mean score was 3.31, 3.68, 3.56, 3.73, 3.75 at admission and week 1, 2, 3, 4. With the detailed item analysis, the following items were shown to be significantly improved: "clean bodies"(F=6.50, P=0.0001) "pain control"(F=18.01, P=0.0001) constipate"(F=2.96, P=0.0237) "sleep"(F=3.99, P=0.0048) "nausea/vomiting"(F=4.50, P=0.0022) "medical team's comfortable care" (F=3.95, P=0.0051) "family's care"(F=2.76, P=0.0317) "anxiety" (F=3.14, P=0.0177) "comfort"(F=3.63, P=0.0085) "treat with dignity"(F=3.32, P=0.0136). The item of "death is not the end of life rather the beginning" was significantly decreased(F=2.54, P=0.0450). 2) Patient's quality of life as perceived by the patient showed an improvement but statistically insignificant and the mean score was 3.63 and 3.83 at admission and week 1. With the detailed item analysis, the item of "pain control" was shown to be significantly improved(F=9.19, P=0.0251). 3) The quality of score in the last week of life of patient were 3.48, 3.51, 3.44, 3.46, 3.50, respectively, from 5 week prior to 1 week prior to death and these changes were insignificant. Conclusion : The findings of this study showed a positive effect of hospice service on quality of life of the terminal cancer patients admitted to the hospice unit. To improve the quality of life, we need first of all to develop hospice interventions with a particular emphasis on the spiritual aspect of patient. Secondly, measurement instruments need to be developed to collect the quality of life of the hospice patients who become weakened especially in the last weeks of their life and with this effort more representative data of hospice patients may be collected.

  • PDF

MEASUREMENT OF ADHESION OF ROOT CANAL SEALER TO DENTINE AND GUTTA-PERCHA (상아질과 Gutta-Percha에 대한 근관충전용 Sealer의 결합강도의 측정)

  • Her, Mi-Ja;Yu, Mi-Kyung;Lee, Se-Joon;Lee, Kwang-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.1
    • /
    • pp.89-99
    • /
    • 2003
  • The purpose of this study was to investigate the bonding of resin- based root canal sealer, AH26 when the sealer was applied as a thin layer between dentine and gutta-percha surface. In this study forty non-caries extracted human molars and resin-based root canal sealer(AH 26, DeTrey/Dentsply, Germany) were used. Disks of gutta-percha, 6mm in diameter.6mm thick (Diadent/Dentsply, Korea) for thermoplastic obturation were used and dentin surfaces were treated with 2% NaOCl(Group 1) or 2%NaOCl+17% EDTA(Group 3). Disks of gutta-Percha, 6mm in diameter.6mm thick (Diadent/Dentsply, Korea) for conventional obturation were used and dentin surface were treated with 2% NaOCl(Group 2) or 2%NaOCl+17% EDTA(Group 4). Enamel was removed by a horizontal section 1mm below the deepest portion of the central occlusal groove by using a watercooled low speed diamond saw. A second horizontal section was done around cementoenamel junction. Exposed dentin surface was cut to approximately $8{\times}8{\;}mm$ rectangular shape and was ground against 320, 400, 600 grade silicon carbide abrasive paper serially. After grinding, the dentine surface were soaked in a solution of 2% NaOCl for 30 minutes and twenty of specimens were treated with 17% EDTA solution for 1 minute. The treated specimens were washed and dried, Root canal sealer, AH26 was prepared according to the manufacture's instructions The Gutta-percha and dentin surface were coated with a thin layer of the freshly mixed seal or. The specimens were left overnight at room temperature. After their initial set, they were transferred to an incubator at $37$^{\circ}C$ for 72 h. After 72 hours, resin blocks were made. The resin block was serially sectioned vertically into stick of $1{\cdot}1mm$. Twenty sticks were prepared from each group. After that, tensile bond strength f3r each stick was measured with Microtensile Tester Failure patterns of the specimens at the interface between gutta-percha and dentin were observed under the SEM(x1000) and Stereomicroscope (LEICA M42O, Meyer Inst., TX U.S.A) at 1.25 x25 magnification. The results were statistically analysed by using a One-way ANOVA and Tukey's test. The results were as follows; 1. Tensile bond strengths($mean{\pm}SD$) were expressed with ascending order as follows: Group 1, $3.09{\pm}$ 1.05Mpa : Group 2, $6.23{\pm}1.16MPa$ : Group 3, $7.12{\pm}1.07MPa$ : Group 4, $10.32{\pm}2.06MPa$. 2. Tensile bond strengths of the group 2 and 4 used disks of gutta-percha for conventional obturation were significantly higher than that of the group 1 and 3 used fir thermoplastic obturation. (p < 0.05). 3. Tensile bond strengths of the group 3 and 4 treated with 2% NaOC1+17% EDTA were significantly higher than that of the group 1 and 2 treated with 2% NaOCl. (p < 0.05). 4. In analysis of failure patterns at the interface between sealer and gutta-percha, there were observed 49 (61%)cases of adhesive failure patterns and 31 (39%) cases of mixed failures patterns.

Texture characteristics of Angdo Pyun as affected by ingredients (재료배합비에 따른 앵도편의 Texture 특성)

  • 류재영;이효지
    • Korean journal of food and cookery science
    • /
    • v.2 no.1
    • /
    • pp.45-53
    • /
    • 1986
  • This study was conducted to investigate the effects of the properties of sugar (20%, 30%) and starch (l5%, 20%, 25%) to Angdo on Angdo Pyun's preference, texture and color_ Textural characteristics were examined through sensory evaluation, Rheometer. Color test by Color and color difference meter. The properties through sensory evaluation were appearance, color, flavor, hardness, thickness and acceptability. With Rheometer, compression force, work ratio, adhesive work and gumminess were measured. With Color and Color difference meter, L, a ana b were measured. The results were as follows: 1. Sensory evaluation indicated that with the increase of starch addition, the Angdo Pyun maintained a worse apperance and got hardened and thickened. As the amount of suger increased, the Angdo fyun maintained better in color and flavor as well as its acceptability. 2. Rheometer measurement indicated that a compression force, work ratio, adhesive work and gumminess tended to increase, as the starch proportion increased. As the amount of sugar increased, the Angdo Pyun maintained a greater adhesive work, work ratio and gumminess. 3. Color and Color difference meter indicated that figure L ana a tended to increase and b, ΔE and ΔC decrease, as the starch proportion increased. 4. In the analysis of correlation between hardness and compression force, it was found that they are highly related. In view of the above results, it came to the conclusion that Angdo Pyun with the addition of 30% sugar and 15% starch could give the best result among the groups studied.

  • PDF

Experimental Performance Evaluation of Steel Mesh as Maintenance and Reinforcement Materials (Steel Mesh Cement Mortar의 보수⋅보강 성능 평가)

  • Kim, Yeon-Sang;Choi, Seung-Jai;Kim, Jang-Ho Jay
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.4
    • /
    • pp.50-58
    • /
    • 2014
  • Due to the cost burden of new construction, the necessity of repair and retrofitting of aged structures is sharply increasing as the domain of repair and retrofitting construction is expanding. Because of the necessity, new technologies for repair and retrofitting are continuously studied in Korea and foreign countries. Steel adhesive method, fiber reinforced plastic (FRP) surface adhesive method, and external prestressing method are used to perform the repair and retrofitting works in Korea. In order to consider a repair method using steel mesh reinforced cement mortar (SMCM), 3-point flexural member test was conducted considering repair area and layer number of SMCM. Five types of specimens including ordinary reinforced concrete (RC) specimen with dimensions of $1400{\times}500{\times}200$ (mm) were cast for testing the deflection measurement, a LVDT was installed at the top center of the specimens. Also, a steel strain gauge and a concrete strain gauge were placed at the center of the specimens. A steel strain gauge was also installed on the shear reinforcement. The 3 point flexural member test results showed that the maximum load of SMCM reinforced specimen was higher than that of basic RC specimen in all of the load-displacement curves. Also, the results showed that, when the whole lower part of the basic RC specimen was reinforced, the maximum load and strain were 1.18 and 1.37 times higher than that of the basic RC specimen, respectively. Each specimen showed a slightly different failure behavior where the difference of the results was caused by the difference in the adhesive level between SMCM and RC. Particularly, in SM-B1 specimen, SMCM spalled off during the experiment. This failure behavior showed that the adhesive performance for RC must be improved in order to utilize SMCM as repair and retrofitting material.

An Experimental Study on Development of the Opening Apparatus for Oil Boom (오일펜스 전개장치 개발에 관한 실험적 연구)

  • Jang Duck-Jong;Na Sun-Chol
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.9 no.1
    • /
    • pp.45-54
    • /
    • 2006
  • The study was to review methods by which a ship can unfold and tow an oil boom by attaching the opening apparatus to an oil boom through experiments. The shape and dimension of the opening apparatus were designed with the measurement value of the towing tension load of the oil boom and the dimension of winch drum of the oil boom installed in the ship considered. For the field experiment to identify the performance of the opening apparatus, opening apparatuses were prepared to have the dimension of $3.0m^2$ and $6.0m^2$ which is 91% and 75% of the calculation value for type B and C respectively. As a result, T(kg), the value of tension in type B oil boom according to the towing speed(v) change when two ships are towed together were proved to be $T=920v^{1.1}\;and\;T=500v^{0.9}$ in case the distance is 100 m and 50 m. Based on the result, the dimension of the opening apparatus for type B and C oil boom was calculated as $3.3m^2$ and $8.0m^2$ respectively. When unfolding and towing by attaching the opening apparatus and 200 m of towing line at both ends of type B and type C oil boom, the maximum width of the opening apparatus was shown as 114 m and 95 m in average(width of opening/total length of oil boom: 33% and 57%) in the towing speed of 1.5 kt. It was evaluated that the opening apparatus could concentrate the spilled oil in a good performance. However as far as the increase rate of oil boom opening width according to the length of the towing line is debatable, the increase rate is remarkably reduced when it is lengthened from 100 m to 150 m and to 200 m although it showed extreme increase of 31% and 40% when the length of the towing line was changed from 50 m to 100 m. Therefore, it is inferred that the towing line should be maintained more or less 100 m to get good spread efficiency of the opening apparatus. Additionally, if the towing speed is faster than 1.5 kt, the opening width was narrowed because of the reduced spread efficiency and the shape of the oil boom can be unstable because of the partial sinking of the oil boom, run over waves, or flap of skirt. Thus the reasonable towing speed can be within 1.5 kt for the operation of the opening apparatus.

  • PDF

A Study on Development of Alternative Non-aqueous Cleaning Agents to Ozone Depletion Substances and its Field Application (오존파괴물질 대체 비수계세정제 개발 및 현장 적용 연구)

  • Park, Yong-Bae;Bae, Jae-Heum;Lee, Min-Jae;Lee, Jong-Gi;Lee, Ho-Yeoul;Bae, Soo-Jung;Lee, Dong-Kee
    • Clean Technology
    • /
    • v.17 no.4
    • /
    • pp.306-313
    • /
    • 2011
  • Flux or solder is used in soldering process for manufacturing electronic parts such as printed circuit boards (PCB). After soldering process, residual flux and solder paste on the parts should be removed since their residuals could cause performance degradation or failure of parts due to their corrosion and electric leakage. Ozone depletion substances such as 1,1,1- trichloroethane (TCE) and HCFC-141b have widely been using for removal of residual flux and solder paste after soldering process In manufacturing of electronic parts until now. In this study, non-aqueous cleaning agents without flash point were developed and applied to industrial field for replacement of cleaning agents with ozone depletion. In order to develop non-aqueous cleaning agents without ethers, esters, fluoride- type solvents. And their physical properties and cleaning abilities were evaluated, and they were applied to industrial fields for cleaning of flux and solder on the PCB. And vacuum distillation apparatus were operated to determine their operating conditions and recycling yields for recycling of used cleaning agents formulated in this study. As a result of physical properties measurement of our formulated cleaning agents, they were expected to have good wetting and penetrating power since their surface tensions were relatively low as 18.0~20.4 dyne/$cm^2$ and their wetting indices are relatively large. And some cleaning agents holding fluoride-type solvents as their components did not have any flash point and they seemed to be safe in their handling and storage. The cleaning experimental results showed that some cleaning agents were better in their cleaning of flux and solder paste than 1,1,1-TCE and HCFC-141b. And industrial application results of the formulated cleaning agents for cleaning PCB indicated that they can be applicable to industry due to their good cleaning capability in comparison with HCFC-141b. The recycling experiments of the used formulated cleaning agents through a vacuum distillation apparatus also showed that their 91.9~97.5% could be recycled with its proper operating conditions.

Preparation and Characterization of $Cu/Ce_xZr_{1-x}O_2$ Catalysts for Preferential Oxidation of Carbon Monoxide (일산화탄소의 선택적 산화반응을 위한 $Cu/Ce_xZr_{1-x}O_2$ 촉매의 합성과 특성분석)

  • Lee, So-Yeon;Lee, Suk-Hee;Cheon, Jae-Kee;Woo, Hee-Chul
    • Clean Technology
    • /
    • v.13 no.1 s.36
    • /
    • pp.54-63
    • /
    • 2007
  • Even traces of CO in the hydrogen-rich feed gas to proton exchange membrane fuel cells (PEMFC) poison the platinum anode electrode and dramatically decrease the power output. In this work, a variety of catalytic materials consisting of $Cu/Ce_xZr_{1-x}O_2$, (x = 0.0-1.0) were synthesised, characterized and tested for CO oxidation and preferential oxidation of CO (PROX). These catalysts prepared by hydrothermal and deposition-precipitation methods. The catalysts were characterized by XRD, XRF, SEM, BET, $N_2O$ titration and oxygen storage capacity (OSC) measurement. The effects of composition of the support and degree of excess oxygen were investigated fur activity and $CO_2$ selectivity with different temperatures. The composition of the support markedly influenced the PROX activity. Among the various $Cu/Ce_xZr_{1-x}O_2$ catalysts having different composition, $Cu/Ce_{0.9}Zr_{0.1}O_2$ and $Cu/Ce_{0.7}Zr_{0.3}O_2$ showed the highest activities (>99%) and selectivities (ca.50%) in the temperature range of $150{\sim}160^{\circ}C$. It was found that by using of $Ce_xZr_{1-x}O_2$ mixed oxide support which possesses a high oxygen storage capacity, oxidation-reduction activity of Cu-based catalyst was improved, which resulted in the increase of catalytic activity and selectivity of CO oxidation in excess $H_2$ environments.

  • PDF