• Title/Summary/Keyword: 측벽

Search Result 331, Processing Time 0.029 seconds

Study on the Ventilation System Applicability of High-rise Hog Building for Growing-fattening (고상식 육성비육돈사에 적합한 환기시스템에 관한 연구)

  • Yoo, Yong-Hee;Song, Jun-Ik;Choi, Dong-Yoon;Chung, Eui-Soo;Jeon, Kyoung-Ho;Lee, Poong-Yeon;Kim, Sang-Woo;Jeung, Jong-Won
    • Journal of Animal Environmental Science
    • /
    • v.16 no.1
    • /
    • pp.41-50
    • /
    • 2010
  • The goal of this study was to develop a suitable ventilation system for high-rise hog building (HRHB) for growing-fattening with combined slatted floor pen in second story and in situ manure management system in Korea. The HRHB was constructed as 29m long, 9m wide and 7.6m high for outer dimension with an indoor height of 3.1m and 2.4 for lower and upper floor, respectively. Ventilation systems for each treatment were installed in separated rooms of HRHB. The ventilation types installed in each room were following 3 types: ventilation type 1 (V1), where air was pulled through a circular duct inlet and exhausted by fans; ventilation type 2 (V2), where air was pulled through eave inlet (side ceiling inlet) and exhausted by fans; and ventilation type 3 (V3), where air was pulled through baffled ceiling inlet and exhausted by fans. For each ventilation system, investigated air velocity under minimum, medium and maximum ventilation ratio and air flow pattern inside. The results were as follows; For air flow pattern from top to bottom, V1 showed a homogeneous vertical type, V2 showed a bilateral symmetry type and V3 showed an vertical umbrella type. Under minimum ventilation ratio, air velocity in upper floor (80cm above the slated floor) was similar for V1, V2, and V3. Under maximum ventilation ratio, air velocity in upper floor was undeviating for V1 (0.10~0.26m/s) and varied for V2 (0.12~0.63m/s) while those for V3 was relatively slow and less varied (0.07~0.15m/s). In conclusion, Duct inlet type (V1) can be applied to the development of a new HRHB with additional evaluations such as field test hog feeding.

Analysis of Pretreatment Prognostic Factors in Locally Advanced Carcinoma of the Uterine Cervix (국소진행된 자궁경부암에 있어서의 예후인자 분석)

  • Oh, Do-Hoon;Ha, Sung-Whan;Lee, Moo-Song
    • Radiation Oncology Journal
    • /
    • v.10 no.1
    • /
    • pp.69-76
    • /
    • 1992
  • To identify pretreatment prognostic factors in locally advanced carcinoma of the uterine cervix, retrospective analysis was undertaken of 154 patients treated with curative radiation therapy at Seoul National University Hospital, from March 1979 through December 1986. According to FIGO classification, eight patients were stage IIIA, 134 were stage IIIB, and 12 were stage IVA. Five year locoregional control rate was $58\%$, $51\%$, and $27\%$ in stage IIIA, IIIB, and IVA, respectively. Five year disease free survival was $57\%$, $40\%$, and $25\%$ for each stage respectively. Five year overall survival was $67\%$, $51\%$, and $33\%$ in stage IIIA, IIIB, and IVA, respectively. In univariate analysis, fewer than or equal to four of pregnancies, initial hemoglobin of lower than $10\;g\%$, and pelvic sidewall invasion on CT were associated with poor locoregional control. Number of pregnancies, initial hemoglobin level, obstructive uropathy on intavenous pyelography (IVP), pelvic lymph node (LN) status on CT, and pelvic sidewall invasion on CT were significant factors in disease free survival. In terms of overall survival, pelvic sidewall invasion on CT and bladder invasion on CT were prognostically significant. In multivariate analysis, no factor was found to affect locoregional control and pelvic LN status was a sole significant factor affecting disease free survival. in terms of overall survival, the size.

  • PDF

Evaluation of Ventilation Systems in an Enclosed Growing Pig House (무창육성돈사의 환기시스템에 따른 환기효율 평가)

  • Song, J.I.;Choi, H.L.
    • Journal of Animal Science and Technology
    • /
    • v.44 no.1
    • /
    • pp.135-144
    • /
    • 2002
  • An experiment was conducted to evaluate a ventilation system, which was devised to encourage farmers to use the enclosed growing and finishing pig housing system. A roof-air-entry ventilation system in winter and a side-wall-air-entry system in summer were evaluated. Air flow rate on the floor level which is the low part of pen and the living area of pigs in the enclosed growing and finishing pig house during winter was measured at 0 to 0.19 m/s at the minimum ventilation efficiency of 1,440 $m^{3}/h$. During summer the air flow rate was detected at 0.07 to 0.42 m/s at the maximum ventilation efficiency of 24,000 $m^{3}/h$. Therefore, it is concluded that the side-wall ventilation system is suitable for growing and finishing pigs in the enclosed house during the days of mid-summer and the roof-ventilation system was suitable during the coldest days of mid-winter. In addition, although the enclosed pig house has the system in which air exhausts through only one side wall, air should enter through both-side walls for the better ventilation performance.

Flow Resistance of Vertical Rib Sidewall in Open Channel (개수로 측벽 세로돌출줄눈의 흐름저항)

  • Park, Sang Deog;Ji, Min Gyu;Nam, A Reum;Woo, Tae Young;Shin, Seung Sook
    • Journal of Korea Water Resources Association
    • /
    • v.46 no.9
    • /
    • pp.947-956
    • /
    • 2013
  • Most of flood protection walls built on the impingement in mountain rivers have been made of concrete. It may cause flood disasters because the smooth wall surface could increase flow velocity. In this study the hydraulic experiments was carried out to evaluate the effect of one side wall with rectangular vertical ribs on flow resistance in open channel. The ratio of the pitch between vertical ribs to its depth, ${\lambda}_{nv}$, was designed so that it include the so-called d type and k type roughness. The range of Froude number, $F_r$, based on hydraulic radius is 0.81~1.12. Flow resistance in the open channel with a rib sidewall depends on the interval length of each ribs and the flow discharge. Maximum flow resistance occurred when ${\lambda}_{nv}$ is 9. In the d type roughness which ${\lambda}_{nv}$ is less than 3, the flow resistance decreases with increase of flow discharge. In the k type roughness which ${\lambda}_{nv}$ is greater than 3, the flow resistance increases with increase of flow discharge. The increments of flow resistance are especially great when ${\lambda}_{nv}$ are 9 and 12. The resistance due to vertical rib is mostly by the shape resistance and the vertical rib on one sidewall of open channel affects on the flow resistance so that the equivalent roughness heights of vertical rib may occur in scale of flow depth. Therefore the vertical ribs may be used to reduce the flow velocity and to move the location of maximum flow velocity from the rib sidewall to the centerward in a cross section of channels.

A Study on the Vibration Characteristics of Subway Structure by Train Load (열차 하중에 의한 지하철 구조물의 진동 특성에 관한 연구)

  • Park, Sung Woo;Park, Seung Su;Hwang, In Baek
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.4
    • /
    • pp.107-115
    • /
    • 2011
  • In this study, the vibration analysis of the underground box structures induced train movement is studied. In order to perform these analysis, dynamic data, which was measured when subway is in service, are gained by attaching accelerometers on the structure such as lower beam, lateral wall and upper slab. Also, accelerometers are attached on the lower beams and side walls of the gravel ballast and concrete ballast sections in order to compare vibration due to ballast materials. The vibration results of upper slabs and lower beams reveal that the vibration on the upper slabs is greater than the lower beams. Also, the results of the crack gauge on the upper slab show that crack width dose not change due to vibration, These means that the effect of the vibration on the structure is very limited. In order to evaluate the vibration of the structure, acceleration unit is converted to velocity unit comparing with the existing velocity data gained from the platforms.

Comparison of Acoustic Performance Depending on the Location of Sound Absorptive and Diffuser in Small Auditoriums Using 1/10 Scale Models (1/10 축소모형을 이용한 소공연장의 흡음재와 확산체의 적용위치에 따른 음향성능 비교)

  • Kim, Tae-Hee;Park, Chan-Jae;Park, Ji-Hoon;Haan, Chan-Hoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.34 no.2
    • /
    • pp.146-156
    • /
    • 2015
  • This study investigated how the location of sound absorptive materials and sound diffusers affects the acoustic performance of small auditoriums. It was conducted for a standard model established with the averaged dimension of 36 auditoriums which had opened since 2000 in Daehak-ro, Seoul. In this study, the installation area of finishing materials was calculated upon a back wall which had the smallest installation effective area of finishing materials. To analyze the changes of acoustic performance according to installation location of finishing materials, experiments were carried out using the 1/10 down scale models for 8 cases which were made by classifying the installation location of ceiling and side wall into the front, middle and rear part.The used acoustic parameters were reverberation time (RT), early decay time (EDT), clarity (C80), definition (D50) and speech transmission index (STI). In result, the index related to the amount of reverberant sound (RT, EDT) showed the great changes when evaluating it through just noticeable difference (JND), but the one related to clarity (C80, D50, STI) hardly indicated the changes. In case to obtain short reverberation time, it was most effective to control reverberation time through the side walls when installing sound absorptive and diffusive materials, and side wall front was the location which could get the shortest reverberation time.

MEDICI와 SUPREM4를 이용한 폴리 실리콘 게이트의 벽면 기울기에 따른 NMOS 소자의 전기적 특성 분석

  • No, Ho-Seop;Kim, Jin-Su;Sin, Ju-Yong;Song, Han-Jeong;Lee, Je-Won
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2009.05a
    • /
    • pp.20.1-20.1
    • /
    • 2009
  • 반도체 소자 제조 공정 프로그램인 T-suprem4와 MEDICI를 이용하여 NMOS구조를 설계 하였다. MOS 소자 시뮬레이션을 통해 식각 공정에서 생기는 언더컷에 의한 전기적 특성을 I-V 곡선으로 비교하여 분석하였다. NMOS 구조는 반도체 소자 제조 공정 프로그램 T-suprem4를 이용하여 기본 소자 구조를 설계하였다. 실험의 변수로는 첫째, 소자 공정 중 폴리 실리콘의 언더컷 식각의 각도를 $70^{\circ}C$부터 $110^{\circ}C$까지 $10^{\circ}C$의 차이로 설계하였다. 또한, 언더컷에 의한 드레인-소스사이의 전류($I_{DS}$) 손실이 없는 유효한 각도를 확인하기 위해 $80^{\circ}C$부터 $100^{\circ}C$까지는 $2^{\circ}C$ 크기로 설계 하였다. 둘째, 게이트 크기를 축소하고 역시 언더컷 식각의 각도를 다양하게 설계하였다. 설계된 소자를 반도체 소자 특성 분석 프로그램 MEDICI를 이용하여 소자의 전기적 특성을 측정하였다. 우선 NMOS소자 게이트에 2V의 전압을 인가하였다. 그리고 드레인 부분에 전압을 인가하여 그에 따른 드레인의 전류를 측정 하였다. 드레인 전압은 0V 부터 변화시키며 인가하였다. 측정된 전류 값으로 I-V 곡선을 나타내었다. I-V 곡선의 분석을 통해 식각 후 언더컷의 각도가 $70^{\circ}C$, $80^{\circ}C$, $110^{\circ}C$ 일 때 $4\times10^{-8}A/{\mu}$의 전류가 흐르고, $90^{\circ}C$, $100^{\circ}C$ 일 때는 $1.8\times10^{-7}A/{\mu}$의 전류가 흐르는 것을 확인 하였다. $80^{\circ}C$에서 $100^{\circ}C$까지는 $2^{\circ}C$ 크기로 측정한 결과 $88^{\circ}C$에서 $100^{\circ}C$ 사이 일 때 $90^{\circ}C$ 각도의 경우와 같이 $1.8\times10^{-7}A/{\mu}$의 전류가 측정 되었다. 즉, 식각 중 수직 측벽 도에 언더컷이 $10^{\circ}C$이상 발생하면 $I_{DS}$ 전류 값이 약 22%로 감소하였다. 또한 일반적으로 $90^{\circ}C$의 수직측벽을 가지는 공정이 중요하다고만 생각 되었지만, 이번 연구를 통하여 식각 후 측벽의 각도가 $88^{\circ}C$에서 $92^{\circ}C$ 사이에 있을 때 $I_{DS}$ 값이 가장 최대가 되는 것을 확인 할 수 있었다.

  • PDF

Numerical Investigations of Vorticity Generation in Fully Vegetated Open-Channel Flows (수치모의를 이용한 전단면 식생 수로에서의 와도 생성 분석)

  • Kang, Hyeongsik
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.2B
    • /
    • pp.179-189
    • /
    • 2010
  • This paper presents a numerical investigation of vorticity generation in fully vegetated open-channel flows. The Reynolds stress model is used for the turbulence closure. Open-channel flows with rough bed-smooth sidewalls and smooth bed-rough sidewalls are simulated. The computed vectors show that in channel flows with rough bed and rough sidewalls, the free-surface secondary currents become relatively smaller and larger, respectively, compared with that of plain channel flows. Also, open-channel flows over vegetation are simulated. The computed bottom vortex occupies the entire water depth, while the free-surface vortex is reduced. The contours of turbulent anisotropy and Reynolds stress are presented with different density of vegetation. The budget analysis of vorticity equation is carried out to investigate the generation mechanism of secondary currents. The results of the budget analysis show that in plain open-channel flow, the production by anisotropy is important in the vicinity of the wall and free-surface boundaries, and the production by Reynolds stress is important in the region away from the boundaries. However, this rule is not effective in vegetated channel flows. Also, in plain channel flows, the vorticity is generated mainly in the vicinity of the free-surface and the bottom, while in vegetated channel flows, the regions of the bottom and vegetation height are important to generate the vorticity.

Fabrication of electrodes on mcirochannel side wall using shadow evaporation effect (샤도우 증착 효과를 이용한 마이크로 채널내 측벽 전극 제작)

  • 강길환;김규만
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.1462-1465
    • /
    • 2004
  • A new method to fabricate metal electrodes on side wall of the microchannel is presented. Coulter counter allows to count the number of cell passing through the microchannel by detecting impedance variation between two electrodes. The relative position of two electrodes is important for sensitivity of impedance measurement. 100nm thick Al electrodes are deposited on the channel side wall by means of shadow evaporation.

  • PDF

Analysis of Structural Characteristic of Small Scale Vinyl House by Region (지역별 소형비닐하우스의 구조특성 분석)

  • 이종원;이석건;이현우
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 2002.11a
    • /
    • pp.306-315
    • /
    • 2002
  • 본 연구는 지역별로 단동비닐하우스의 설치현황, 단면형상, 폭, 지붕높이, 측고, 측벽기울기, 골조재의 규격, 서까래간격, 가로대의 설치위치 및 개수, 내용년수 등을 현장조사를 통하여 비닐하우스의 구조실태를 파악하였다. 설치지역별에 따른 단동비닐하우스의 구조특성을 조사ㆍ분석한 본 연구결과는 관행적으로 시공되고 있는 소형비닐하우스의 구조표준화를 위한 기초자료로 활용할 수 있으며 매년 반복되고 있는 강풍과 폭설로 인한 소형비닐하우스의 피해를 줄일 수 있는 안전모델 개발의 기초자료로 활용할 수 있을 것으로 판단된다.

  • PDF