• Title/Summary/Keyword: 측벽효과

Search Result 58, Processing Time 0.026 seconds

Bank Effect of a Ship Operating in a Shallow Water and Channel (천수 및 수로 운항 시 선박의 측벽효과)

  • Park, Dong-Woo;Choi, Hee-Jong;Pai, Kwang-Jun
    • Journal of Navigation and Port Research
    • /
    • v.38 no.1
    • /
    • pp.19-27
    • /
    • 2014
  • When a ship operates in a shallow water and channel, the hull sinkage and asymmetrical force generated around the ship by the influence of sea bottom and bank walls are caused collision with sea bottom, other ships or the bank itself. Especially, the shipping company and pilots navigating the area of Europe and North America with many channels are deal with it as a important matter to prevent collision. In this paper, hydrodynamic force generated between the ship and bank using the numerical analysis for the safe navigation of ship, that is, sway force and yaw moment should be presumed qualitatively. It makes a program for fluid analysis of the shallow water and bank effect. Analyses are carried out for three kind of parameter, that is, ship's speed, water depth and ship-bank distance for crude oil carriers. The numerical analysis results are compared with results of the experiments and the previous published papers.

Study on the Ejected Plume from Opening Regarding Side-wall Effect in Fire (측벽효과를 고려한 개구부 분출화염 거동 연구)

  • Jeong, Jae-Gun;Shin, Yi-Chul
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.219-220
    • /
    • 2016
  • The behavior of fire plumes has not yet been clearly identified for cases where sidewalls are installed near an opening in an unconfined space. In this research, we aim to quantitatively identify the effects on fire spread when sidewalls are located on both sides of an opening. Specifically, we focus on the effects on the fire plume of the relation between the location of sidewalls and the opening, and carry out a scale-model experiment to devise a flame height model and to evaluate the temperature distribution along the central axis of the flame.

  • PDF

Hydraulic Effect of Vertical-Strip Side Wall in Open Channel Flow (개수로 흐름에서 측벽 수직줄눈의 수리효과)

  • Park, Sang-Deog;Ji, Min-Gyu;Nam, A-Reum;Woo, Tae-Young;Yang, Eun-Ik
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.700-700
    • /
    • 2012
  • 산지유역은 하천을 따라서 도로가 발달되어 있어서 대부분의 도로가 홍수시 하천의 영향을 많이 받는다. 산지하천은 경사가 급하고 만곡수충부가 많이 발달되어 있기 때문에 홍수시 유속이 빠르고 만곡수충부의 편수위가 매우 크다. 이는 만곡부 호안 파괴와 도로 유실의 피해를 일으키는 경우가 많다. 따라서 대부분의 산지하천 만곡수충부에는 홍수피해 방지를 위해 콘크리트 옹벽호안으로 되어 있다. 그러나 콘크리트 옹벽은 조도가 작기 때문에 유속이 더 빠르게 되고 편수위를 한층 증대시킬 수 있다. 산지하천 만곡수충부의 편수위를 줄이기 위해서는 접근유속을 줄여야 하나 산지하천 특성으로 볼 때 접근유속 저감을 위한 공학적 방법은 제한적이다. 따라서 만곡수충부의 유속을 줄이는 방법으로 콘크리트 옹벽호안의 조도계수를 증대시키는 것이 효과적일 수 있다. 본 연구에서는 개수로 측벽에 수직돌출줄눈이 설치되었을 때 흐름에 미치는 수리효과를 개수로 수리실험으로 파악하고자 한 것이다. 실험결과 돌출줄눈의 간격이 수직돌출줄눈의 무차원 폭이 9일 때 평균유속이 가장 작게 나타났다. 이는 돌출줄눈의 간격이 개수로 내부흐름의 유속분포, 최대유속발생 위치, 유수단 면적의 크기에 영향이 미치기 때문이다. 따라서 개수로 측벽 수직돌출줄눈의 간격을 조절함으로써 개수로 유수저항의 크기를 조절할 수 있다.

  • PDF

Analysis of a Novel Self-Aligned ESD MOSFET having Reduced Hot-Carrier Effects (Hot-Carrier 현상을 줄인 새로운 구조의 자기-정렬된 ESD MOSFET의 분석)

  • 김경환;장민우;최우영
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.5
    • /
    • pp.21-28
    • /
    • 1999
  • A new method of making high speed self-aligned ESD (Elevated Source/Drain) MOSFET is proposed. Different from the conventional LDD (Lightly-Doped Drain) structure, the proposed ESD structure needs only one ion implantation step for the source/drain junctions, and makes it possible to modify the depth of the recessed channel by use of dry etching process. This structure alleviates hot-carrier stress by use of removable nitride sidewall spacers. Furthermore, the inverted sidewall spacers are used as a self-aligning mask to solve the self-align problem. Simulation results show that the impact ionization rate ($I_{SUB}/I_{D}$) is reduced and DIBL (Drain Induced Barrier Lowering) characteristics are improved by proper design of the structure parameters such as channel depth and sidewall spacer width. In addition, the use of removable nitride sidewall spacers also enhances hot-carrier characteristics by reducing the peak lateral electric field in the channel.

  • PDF

Changes in Fire Characteristics according to the Distance Between the Fire Source and Sidewall in a Reduced-Scale Compartment (축소 구획실에서 화원과 측벽의 거리에 따른 화재특성 변화)

  • Yun, Hong-Seok;Hwang, Cheol-Hong
    • Fire Science and Engineering
    • /
    • v.33 no.1
    • /
    • pp.50-59
    • /
    • 2019
  • Experimental and numerical studies on the fire characteristics according to the distance between the fire source and sidewall under the over-ventilated fire conditions. A 1/3 reduced ISO 9705 room was constructed and spruce wood cribs were used as fuel. Fire Dynamics Simulator (FDS) was used for fire simulations to understand the phenomenon inside the compartment. As a result, the mass loss rate and heat release rate were increased due to the thermal feedback effect of the wall in the compartment fire compared to the open fire. As the distance between the fire source and sidewall was reduced, the major fire characteristics, such as maximum mass loss rate, heat release rate, fire growth rate, temperature, and heat flux, were increased despite the limitations of air entrainment into the flame. In particular, a significant change in these physical quantities was observed for the case of a fire source against the sidewall. In addition, the vertical distribution of temperature was changed considerably due to a change in the flow structure inside the compartment according to the distance between the fire source and sidewall.

Study on the Crack Control Effect of Moist Curing Equipment in Side Wall of Building (습윤양생 장치를 이용한 아파트 측벽 균열제어에 관한 연구)

  • Kim, Dae-Geon;Lee, Dong-Woon
    • Journal of the Korea Institute of Building Construction
    • /
    • v.17 no.2
    • /
    • pp.127-134
    • /
    • 2017
  • In this study, moist curing equipment was used in the exist gang-form system. By achieving sufficient spray curing, the quality of the concrete was improved and the cracking occurred in building's side wall was decreased. The following results could be made as the conclusion. For the compressive strength, all zones showed the similar results. Comparing with the zone without using moist curing equipment, the zone used moist curing equipment showed higher rebound hardness results. For the cracking, the zone utilized moist curing equipment showed the cracking averaged as 6.6 m and the zone without using moist curing equipment showed the cracking averaged as 10.3m. The effectof reducing cracking by utilizing moist curing equipment is about 36 %. Using moist curing equipment is considered as a good solution to reduce the cracking in the structure. Considering all the factors analysed, using moist curing equipment improved the quality of the concrete and decreased the cracking. When this equipment was used in the construction site, it is expected that the construction periodcan be shrunk and the ratio of defect caused by drying shrinkage can be decreased. In this research conditions, The 0.3mm sized moist curing equipment provided the most desirable results on concrete quality and preventing cracking.

An Experimental Study on Suppression of Cavity Development by Enlargement of Base Plate of Box-Culvert Installed at River Levee (하천제방 배수통문의 저판확폭을 통한 공동발생 억제기법 연구)

  • Kim, Jin-Man;Choi, Bong-Hyuck;Lee, Dae-Young;Jin, Young-Ji
    • Journal of the Korean Geotechnical Society
    • /
    • v.27 no.3
    • /
    • pp.55-61
    • /
    • 2011
  • Generally, the Box-Culvert in levee is destroyed by various reasons. Especially when Box-Culvert is installed over the pile foundation in soft ground, the failure occurrs for 1) the weakness of compaction in Box-Culvert side by the differential settlement between outer ground and inner soil prism, 2) hydraulic fracturing and disturbance of Box-Culvert side soil by the repeated acting of seepage pressure at flood time. Also the side of Box-Culvert is difficult to compact and the shear resistance is reduced by more than 1/3 for the reduction of friction caused by the difference of material property. In this study, a series of model tests are conducted for the analysis of the development mechanism of outer ground and inner soil prism by the differential settlement using the pile foundation in soft ground, and cavity suppressed technique is suggested by the analysis of base plate enlargement effect.

The Effect of Vantilation System Renovation from Winch Style to Non-window Style for Swine Barn (개방돈사의 무창돈사형 환기시설 개선 효과)

  • Song, J.I.;Jean, J.H.;Park, H.K.;Kang, H.S.;Choi, D.Y.;Kim, D.H.;Park, K.H.
    • Journal of Animal Environmental Science
    • /
    • v.16 no.2
    • /
    • pp.109-114
    • /
    • 2010
  • In South Korea, mora than 90% of swine barns had open-style side wall by winch operation, and less than 5% of swine barns were semi-windowless or windowless style. The aisle ventilation system of the barn was changed to roof-wall ventilation system, and the width and the length of barns were 10~12 m and 30~50 m, respectively. The width of aisle satisfying energy save was 2~3 m. The re-modeled barns inhaled air through duct which was opened to aisle and exhaled through forced ventilation fans on the windowless wall which was accomplished by installing planks on the open wall. After remodelling, the culling ratio and energy cost were decreased from 11% (47 heads) to 3% (12 heads) and from 1,550,000 won to 730,000 won, respectively. Hence, re-modeled swine barns raising 400 heads could save 2,835,680 won during winter (from December to March).

Fabrication of electrodes on mcirochannel side wall using shadow evaporation effect (샤도우 증착 효과를 이용한 마이크로 채널내 측벽 전극 제작)

  • 강길환;김규만
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.1462-1465
    • /
    • 2004
  • A new method to fabricate metal electrodes on side wall of the microchannel is presented. Coulter counter allows to count the number of cell passing through the microchannel by detecting impedance variation between two electrodes. The relative position of two electrodes is important for sensitivity of impedance measurement. 100nm thick Al electrodes are deposited on the channel side wall by means of shadow evaporation.

  • PDF

A Case Study on the Improvement of the Beauty of Photovoltaic Generator : Focusing on the case of installation on the vertical side wall of a building (태양광 발전기의 심미성 향상을 위한 사례분석 연구 : 건물 수직 측벽에 설치되는 사례를 중심으로)

  • Lee, Jae-Hyun;Park, Ji-Hoon;Nam, Won-Suk;Jang, Jung-Sik
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.12
    • /
    • pp.97-103
    • /
    • 2020
  • This study sets the solar power system installed and applied to the vertical side wall among the photovoltaic systems in the building as the scope of the research. The theoretical background was considered through literature research as a research method, and the current status, trends and characteristics of solar generator design installed and applied to domestic and foreign vertical side walls were then investigated and analyzed cases. As a result, the importance and necessity of photovoltaic generators, potential for power generation and growth were identified, and positive factors and directions were found for improving aestheticity. Based on this point, we would like to propose expected effects that can be applied to photovoltaic system design installed and applied to vertical side walls in the future, and confirm the direction and significance of the improvement of aesthetic quality of the proposal for development of thin film solar cell design technology using green facade design.