• Title/Summary/Keyword: 측방이동

Search Result 80, Processing Time 0.031 seconds

Indirect palatal skeletal anchorage (PSA) for treatment of skeletal Class I bialveolar protrusion (Indirect palatal skeletal anchorage (PSA)를 이용한 골격성 I급 양악 치성 전돌 환자의 치험례)

  • Chae, Jong-Moon
    • The korean journal of orthodontics
    • /
    • v.34 no.5 s.106
    • /
    • pp.458-464
    • /
    • 2004
  • Anchorage plays an important role in orthodontic treatment especially in the maxillary arch. In spite of many efforts for anchorage control. it was difficult for clinicians to predict the result of treatment because most of the treatment necessitated an absolute compliance of patients, But recently, skeletal anchorage has been used widely because it does not necessitate patient compliance but produces absolute anchorage. In addition titanium miniscrews have several advantages such as ease of insertion and removal. possible immediate leading and use in limited implantation spaces. In this case, a skeletal Class I bialveolar protrusion Patient was treated with standard edgewise mechanics using indirect active P.S.A. (palatal skeletal anchorage). The miniscrews in the paramedian area of the hard palate provided anchorage for retraction of the upper anterior teeth and remained firm and stable throughout treatment This indicates that the PSA can be used to reinforce anchorage for orthodontic treatment in the maxillary arch Consequently, this new approach can help effective tooth movement without patient compliance, when used with various transpalatal arch systems.

ORTHODONTIC TREATMENT OF THE DISPLACED UNERUPTED MAXILLARY CANINE : CASE REPORT (변위된 미맹출 상악 견치의 교정 치험례)

  • Lim, Hye-Jeong;Choi, Nam-Ki;Kim, Seon-Mi;Yang, Kyu-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.3
    • /
    • pp.543-549
    • /
    • 2005
  • The maxillary canine is especially important as it has the longest root, provides guidance for lateral movement of the mandible and masticatory function and is a key in esthetics due to its position. Maxillary canine has the longest time to develop and a complex route from the place of formation to the site of eruption, and so it is prone to impaction more than other teeth. The clinician should consider the various treatment options : (a) No treatment and observation, (b) surgical exposure and orthodontic traction (c) autotransplantation (d) extraction. Surgical exposure of the canine and orthodontic treatment to bring the tooth into the line of occlusion is considered the most desirable approach. This case presents the results of treatment for impacted maxillary canine by surgical exposure and orthodontic tooth movement.

  • PDF

The laterally closed tunnel for the treatment of mandibular gingival recession in thin biotype patients: case report (얇은 치주 생체형 환자에서 교정 치료 후 발생한 하악 전치부 치은 퇴축에 대한 laterally closed tunnel procedure의 처치: 증례보고)

  • Kim, Hyun-Joo;Kwon, Eun-Young;Lee, Ju-Youn;Joo, Ji-Young
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.35 no.4
    • /
    • pp.253-259
    • /
    • 2019
  • In this case report, gingival recession of the mandibular anterior teeth was treated with a laterally closed tunnel technique. Two patients had altered the inclination of mandibular anterior tooth during past orthodontic treatment and had periodontal thin biotype. The recipient site was formed by tunneling method, and the connective tissue graft obtained from the palatal side was placed in the tunnel, and the margins of flap were gathered at the center of the root and sutured. Despite the thin periodontal biotype, the root coverage was successfully obtained, keratinized gingiva was increased, and aesthetics were achieved by harmonizing with surrounding tissues in terms of shape and color.

A 3-D finite element analysis on the mandibular movement pattern and stress distribution during symphyseal widening (하악 이부확장 시 하악골 이동 양상과 응력 분포에 관한 삼차원 유한요소법적 연구)

  • Lee, Do-Hoon;Hong, Hyun-Sil;Chae, Jong-Moon;Jo, Jin-Hyung;Kim, Sang-Cheol
    • The korean journal of orthodontics
    • /
    • v.38 no.1
    • /
    • pp.13-30
    • /
    • 2008
  • Objective: The objective of this study was to evaluate the displacement pattern and the stress distribution of the finite element model 3-D visualization during symphyseal widening according to the osteotomy position, osteotomy type, and distraction device. Methods: The kinds of distraction devices used were tooth-borne type, hybrid type, bone-borne type and tooth-borne type $30^{\circ}$ angulated, and the kinds of osteotomy design were vertical osteotomy line between the central incisors and step osteotomy line through the symphysis. Results: All reference points of the mandible including the condyles were displaced laterally irrespective of the osteotomy position, osteotomy method and distraction device. The anteroposterior or vertical displacements showed small differences between the groups. The widening pattern of the osteotomy line in the tooth-borne type of device was v shaped, and that of bone-borne type was a reverse v shape. However, the pattern in the hybrid type was parallel. The lateral displacement of the mandibular angle by the bone-borne device was more remarkable than the other types of devices. The displacement by the $30^{\circ}$ angulated tooth-borne type was different between the left and right sides in both the transverse and anteroposterior aspects. Conclusion: The design of the distraction devices and osteotomy line can influence the displacement pattern and the stress distribution during mandibular symphyseal distraction osteogenesis procedures.

A THREE-DIMENSIONAL FEM COMPARISON STUDY ABOUT THE FORCE, DISPLACEMENT AND INITIAL STRESS DISTRIBUTION ON THE MAXILLARY FIRST MOLARS BY THE APPLICATION OF VAR10US ASYMMETRIC HEAD-GEAR (비대칭 헤드기어의 적용시 상악제 1 대구치에 나타나는힘과 변위 및 초기 응력분포에 관한 3차원 유한요소법적 연구)

  • Kim, Jong-Soo;Cha, Dyung-Suk;Ju, Jin-Won;Lee, Jin-Woo
    • The korean journal of orthodontics
    • /
    • v.31 no.1 s.84
    • /
    • pp.25-38
    • /
    • 2001
  • The purpose of this study was to compare the force, the displacement and the stress distribution on the maxillary first molars altered by the application of various asymmetric head-gear. For this study, the finite element models of unilateral Cl II maxillary dental arch was made. Also, the finite element models of asymmetric face-bow was made. Three types of asymmetric face-bow were made : each of the right side 15mm, 25mm and 35mm shorter than the left side. We compared the forces, the displacement and the distribution of stress that were generated by application of various asymmetric head-gear, The results were as follows. 1. The total forces that both maxillary first molars received were similar in all groups. But the forces that mesially positioned tooth received were increased as the length of the outer-bow shortened, and the forces that normally positioned tooth received were decreased as the length of the outer-bow shortened. 2. In lateral force comparison, the buccal forces that normally positioned tooth received were increased as the length of the outer-bow shortened, and the buccal fortes that mesially positioned tooth received were decreased as the length of the outer-bow shortened. Though the net lateral force moved to the buccal side of normally positioned tooth as the length of the outer-bow shortened, both maxillary first molars received the buccal force. That showed 'Avchiai Expansion Effect' 3. The distal forces, the extrusion forces and the magnitudes of the crown distal tipping that mesially positioned tooth received were increased as the length of the outer-bow shortened, and the forces that normally positioned tooth received were decreased as the length of the outer-bow was shortened. 4. The magnitude of the distal-in rotation that normally positioned tooth received were increased as the length of the outer-bow was shortened. But, mesially positioned tooth show two different results. For the outer-bow 15mm shortened, mesially positioned tooth showed the distal-in rotation, hut for the outer-bow 25mm and 35mn shortened, mesially positioned tooth showed the distal-out rotation. Thus, the turning point exists between 15mm and 25mm. 5. This study of the initial stress distribution of the periodontal ligament at slightly inferior of the furcation area revealed that the compressive stress in the distobuccal root of the normally positioned tooth moved from the palatal side to the distal side and the buccal side successively as the length of the outer-bow shortened. 6. This study of the initial stress distribution of the periodontal ligament at slightly inferior of the furcation area revealed that the magnitudes of stress were altered but the total stress distributions were not altered in the mesiobuccal root and the palatal root of normally positioned tooth, and also three roots of mesially positioned tooth as the length of the outer-bow shortened.

  • PDF

The Dosimetric Data of 10 MV Linear Accelerator Photon Beam for Total Body Irradiation (전신 방사선조사를 위한 10MV 선형가속기의 선량측정)

  • Ahn Sung Ja;Kang Wee-Saing;Park Seung Jin;Nam Taek Keun;Chung Woong Ki;Nah Byung Sik
    • Radiation Oncology Journal
    • /
    • v.12 no.2
    • /
    • pp.225-232
    • /
    • 1994
  • Purpose : This study was to obtain the basic dosimetric data using the 10 MV X-ray for the total body irradiation. Materials and Methods : A linear accelerator photon beam is planned to be used as a radiation source for total body irradiation (TBI) in Chonnam University Hospital. The planned distance from the target to the midplane of a patient is 360cm and the maximum geometric field size is 144cm x 144cm. Polystyrene phantom sized $30{\times}30{\times}30.2cm^3$ and consisted of several sheets with various thickness, and a parallel plate ionization chamber were used to measure surface dose and percent depth dose (PDD) at 345cm SSD, and dose profiles. To evaluate whether a beam modifier is necessary for TBI, dosimetry in build up region was made first with no modifier and next with an 1cm thick acryl plate 20cm far from the polystyrene phantom surface. For a fixed sourec-chamber distance, output factors were measured for various depth. Results : As any beam modifier was not on the way of radiation of 10MV X-ray, the $d_{max}$ and surface dose was 1.8cm and $61\%$, respectively, for 345cm SSD. When an 1cm thick acryl plate was put 20cm far from polystyrene phantom for the SSD, the $d_{max}$ and surface dose were 0.8cm and $94\%$, respectively. With acryl as a beam spoiler, the PDD at 10cm depth was $78.4\%$ and exit dose was a little higher than expected dose at interface of exit surface. For two-opposing fields for a 30cm phantom thick phantom, the surface dose and maximum dose relative to mid-depth dose in our experiments were $102.5\%$ and $106.3\%$, respectively. The off-axis distance of that point of $95\%$ of beam axis dose were 70cm on principal axis and 80cm on diagonal axis. Conclusion: 1. To increase surface dose for TBI by 10MV X-ray at 360cm SAD, 1cm thick acrylic spoiler was sufficient when distance from phantom surface to spoiler was 20cm. 2. At 345cm SSD, 10MV X-ray beam of full field produced a satisfiable dose uniformity for TBI within $7\%$ in the phantom of 30cm thickness by two-opposing irradiation technique. 3. The uniform dose distribution region was 67cm on principal axis of the beam and 80cm on diagonal axis from beam axis. 4. The output factors at mid-point of various thickness revealed linear relation with depth, and it could be applicable to practical TBI.

  • PDF

RELATIONSHIPS BETWEEN MANDIBULAR LATERAL DEVIATION AND MORPHOLOGY OF THE CRANIAL VAULIT (안면비대칭 환자에서 하악의 측방변위와 두개관형태 사이의 연관성)

  • Shin, Shang-Wook;Jang, Hyun-Jung;Lee, Sang-Han
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.18 no.4
    • /
    • pp.594-606
    • /
    • 1996
  • This study was intended to perform the relationships between mandibualr lateral deviation in facial asymmetry patients and morphology of the cranial vault. In 30 patients(males 14, female 16) using submento-vertical cephalograms that were taken in the pre-operaticve state and posteroanterioir cephalograms that were taken in centric occlusion before, immediate and long term after surgery. 1. Mean mandibular deviation was about $-3.12^{\circ}$and mean of absolute measurement was about $2.50^{\circ}$on the submento-vertical cephalograms. 2. On the submento-vertical cephalograms, there was no significant difference between non-deviation and deviation side but it had tendency that deviation side was larger than non-deviation side on the frontal portion of cranium(Y10 to Y6) and deviation side was smaller than non-deviation on the temporal portion of cranium(Y5, Y-1 to Y-5). 3. Mean mandibular deviation was about $1.40^{\circ}$and mean of absolute measurement was about $3.95^{\circ}$on the posteroanterioir cephalograms. 4. There was statistical significance on the influence of surgical change(PT2A-PT1A) to the relapse(PTLA-PT2A)(p<0.05). The more increasing of the change, the more relapse on the posteroanterioir cephalograms. 5. There was no statistical significance on the influence of degree of mandibular deviation to morphology of the cranium on the submento-vertical cephalograms. But it had tendency that the more mandibular deviation, the larger the non-deviation side on the anterior cranium and deviation side on the posterior cranium(p>0.05). 6. There was statistical significance on the influence of the degree of mandibular deviation on the posteroanterioir cephalograms to the difference between non-deviation and deviation side. The more increasing of mandibular deviation, the larger the non-deviation side on the Y4 to Y-6(p<0.05). 7. There was no statistical significance on the influence of difference between non-deviation and deviation side to the relapse on the posteroanterioir cephalograms. But it had tendency that the more increasing of the differece between non-deviation and deviation side, the more increasing the relapse on temporal of cranium.

  • PDF

Minimization of Small Bowel Volume within Treatment Fields Using Customized Small Bowel Displacement System(SBDS) (골반부 방사선 조사야 내의 소장 용적을 줄이기 위한 Small Bowel Displacement System(SBDS)의 사용)

  • Lim Do Hoon;Huh Seung Jae;Ahn Yong Chan;Kim Dae Yong;Wu Hong Gyun;Kim Moon Kyung;Choi Dong Rak;Shin Kyung Hwan
    • Radiation Oncology Journal
    • /
    • v.15 no.3
    • /
    • pp.263-268
    • /
    • 1997
  • Purpose : Authors designed a customized Small Bowel Displacement System (SBDS) to displace the small bowel from the Pelvic radiation fields and minimize treatment-related bowel morbidities. Materials and Methods : From August 1995 to Mar 1996. 55 consecutive patients who received pelvic radiation therapy with the SBDS were included in this study. The SBDS consists of a customized styrofoam compression device which can displace the small bowel from the radiation fields and an individualized immobilization abdominal board for easy daily setup in prone position After opacifying the small bowel with Barium3, the patients were laid Prone and posterior-anterior (PA) and lateral (LAT) simulation films were taken with and without the SBDS. The areas of the small bowel included in the radiation fields with and without the SBDS were compared. Results : Using the SBDS, the mean small bowel area was reduced by $59\%;on\;PA\;and\;51\%$ on LAT films (P=0.0001). In six Patients (6/55. $11\%$), it was Possible that no small bowel was included within the treatment fields. The mean upward displacement of the most caudal small bowel was 4.8 cm using the SBDS. Only $15\%$ (8/55) of patients treated with the SBDS manifested diarrhea requiring medication. Conclusion : The SBDS is a novel method that can be used to displace the small bowel away from the treatment portal effectively and reduce the radiation therapy morbidities. Compliance with setup is excellent when the SBDS is used.

  • PDF

Development of Dose Planning System for Brachytherapy with High Dose Rate Using Ir-192 Source (고선량률 강내조사선원을 이용한 근접조사선량계획전산화 개발)

  • Choi Tae Jin;Yei Ji Won;Kim Jin Hee;Kim OK;Lee Ho Joon;Han Hyun Soo
    • Radiation Oncology Journal
    • /
    • v.20 no.3
    • /
    • pp.283-293
    • /
    • 2002
  • Purpose : A PC based brachytherapy planning system was developed to display dose distributions on simulation images by 2D isodose curve including the dose profiles, dose-volume histogram and 30 dose distributions. Materials and Methods : Brachytherapy dose planning software was developed especially for the Ir-192 source, which had been developed by KAERI as a substitute for the Co-60 source. The dose computation was achieved by searching for a pre-computed dose matrix which was tabulated as a function of radial and axial distance from a source. In the computation process, the effects of the tissue scattering correction factor and anisotropic dose distributions were included. The computed dose distributions were displayed in 2D film image including the profile dose, 3D isodose curves with wire frame forms and dosevolume histogram. Results : The brachytherapy dose plan was initiated by obtaining source positions on the principal plane of the source axis. The dose distributions in tissue were computed on a $200\times200\;(mm^2)$ plane on which the source axis was located at the center of the plane. The point doses along the longitudinal axis of the source were $4.5\~9.0\%$ smaller than those on the radial axis of the plane, due to the anisotropy created by the cylindrical shape of the source. When compared to manual calculation, the point doses showed $1\~5\%$ discrepancies from the benchmarking plan. The 2D dose distributions of different planes were matched to the same administered isodose level in order to analyze the shape of the optimized dose level. The accumulated dose-volume histogram, displayed as a function of the percentage volume of administered minimum dose level, was used to guide the volume analysis. Conclusion : This study evaluated the developed computerized dose planning system of brachytherapy. The dose distribution was displayed on the coronal, sagittal and axial planes with the dose histogram. The accumulated DVH and 3D dose distributions provided by the developed system may be useful tools for dose analysis in comparison with orthogonal dose planning.

Prosthetic rehabilitation of partially edentulous patient after hemimandiblectomy: Case report (하악골 부분절제술 시행한 부분 무치악 환자에서 보철 수복 증례)

  • Lee, Dong-Hun;Yoo, Dong-Soo;Lee, Jong-Hyuk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.1
    • /
    • pp.39-45
    • /
    • 2015
  • Loss of continuity of the mandible destroys the balance and symmetry of mandibular function, leading to altered mandibular movements and deviation of the residual fragment towards the resected side. Apart from deviation, other dysfunctions include difficulty in swallowing, speech, mandibular movements, mastication, and respiration are accompanied. In general, surgical reconstruction is considered first then proceeds to the prosthetic restorations. However, patients with systemic disease such as BRONJ (Bisphosphonate related osteonecrosis of the Jaw), surgical reconstruction may be limited. Thus, the prosthetic restoration remains as the only resort. Numerous prosthetic methods are employed to minimize deviation and to improve masticatory efficiency, function and esthetics. If a removable partial denture is the selected treatment modality, maximum stability of the partial denture base may be accomplished with a functional impression procedure by means of eliminating lateral and horizontal forces caused by the functional movements of the lips, cheeks and tongue. Also, Twin occlusion is used to obtain a favorable occlusal relationship and check support for esthetics. The purpose of this case report is to demonstrate how neutral zone impression technique and twin occlusion scheme were applied to restore a hemi-mandiblectomy patient with BRONJ syndrome to achieve satisfactory results in functional and esthetic aspects.