• 제목/요약/키워드: 취출온도

검색결과 16건 처리시간 0.02초

교실 규모에 따른 난방 공조환경 평가에 관한 연구 -천장형 냉난방기의 취출온도를 중심으로 - (A Study on the Evaluation of Heating-Conditioned Environment with the Size of Classroom - Focused on Inlet Temperature of Ceiling Type Air-Conditioning System -)

  • 최정민;김용이;박효석
    • 설비공학논문집
    • /
    • 제15권12호
    • /
    • pp.1035-1042
    • /
    • 2003
  • As the desire for a better condition in classroom increases, the distribution rate of warming and cooling conditioners increases. But it is known that according to the way by which the equipments put and are operated the comfortableness felt by persons who are in classroom can make a difference. Therefore, proper equipments in accordance with the size of classroom should be considered as well as operational methods when ceiling warming and cooling conditioners put. This study makes conclusions as follows through a simulation to get improvements in accordance with the size of classroom and to improve the heating performance of ceiling warming and cooling conditioners in classroom.

교실에서의 천장형 냉난방기의 취출온도 및 취출각도에 따른 열환경 시뮬레이션 (Computer Simulation on the Thermal Environment by the Diffusion temperature and Diffusion Angle of Ceiling Type Air Conditioner in Classroom)

  • 박효순;박승익;이상혁;이감규
    • 교육녹색환경연구
    • /
    • 제4권4호
    • /
    • pp.1-18
    • /
    • 2004
  • Research has been carried out to study thermal environment in a classroom under three kinds of air diffusion temperature and six kinds of air diffusion direction for ceiling type air conditioner. The velocity and temperature distributions of air in the room calculated by 3-dimensional numerical method(PHOENICS), This present study was also conducted to calculate the Air Diffusion Performance Index(ADPI) for cooling conditions and Predicted Percentage of Dissatisfied(PPD) for heating conditions. This analysis shows that the optimum angle of ceiling type air conditioner's diffusion is $15{\sim}30^{\circ}$ for cooling mode and about $15{\sim}45^{\circ}$ for heating mode in these calculating conditions. And also analysis has been carried out to evaluate thermal comfort of vertical and horizontal cross section of classroom.

  • PDF

Desiccant 제습에 의한 냉방시스템 응용 (Application for air conditioning of cooling system using desiccant)

  • 최광환
    • 대한설비공학회지:설비저널
    • /
    • 제27권6호
    • /
    • pp.513-522
    • /
    • 1998
  • 우리나라의 여름 기후는 고온 다습한 특징을 갖고 있다. 고온 다습한 지역에서는 습도가 쾌적성을 결정하는데 중요한 요소가 되기 때문에, 습도가 높으면 온도가 그다지 높지 않더라도 쉽게 무더위를 느낀다. 이러한 계절적 특성을 없애 쾌적한 생활을 영위하기 위하여 생활의 질적 향상과 더불어 공조장치의 수요가 매년 두드러지게 증가하고 있다. 특히, 실내의 경우에는 공조장치 중 대표적인 에어컨(air conditioner)으로 냉방을 행함으로써 고온 다습한 여름철의 거주공간을 개선하고 있다. 그러나 고온 다습한 환경하에서의 과다한 에어컨 사용은 인체의 온열 환경적 측면에서 오히려 불리하다. 왜냐 하면, 에어컨에서는 여름철에 잠열(latent heat)을 고려해야 함에도 불구하고 단지 현열비(sensible heat factor)로 취출온도를 결정하고 있기 때문이다. 그 결과, 실내가 과다하게 냉각되어 재실자에게 불쾌감은 물론, 심지어 냉방병도 초래할 수가 있다.

  • PDF

바닥취출 공조공간에서 급기온도 및 급기풍속이 환기효율에 미치는 영향 (Effect of supply air temperature and airflow rate on ventilation effectiveness in an underfloor air conditioning space)

  • 정광섭;한화택;홍승재
    • 설비공학논문집
    • /
    • 제10권5호
    • /
    • pp.640-648
    • /
    • 1998
  • A numerical study has been conducted to investigate the effect of inflow supply air temperature and velocity on ventilation effectiveness in an underfloor air conditioning space. A low Reynolds number k-$\varepsilon$ model is implemented to calculate steady state turbulent velocity distributions. A step-down injection method is used to calculate local and room mean ages from transient concentrations based on the concept of the age of air. Results show that there is a significant effect of Archimedes number on ventilation effectiveness especially for cooling conditions. Reynolds number shows relatively minor effect on velocity distribution and ventilation effectiveness especially for isothermal and heating conditions. It can be concluded that underfloor air conditioning system provides good ventilation characteristics for cooling conditions because of temperature stratification in the space.

  • PDF

컴퓨터실의 열취득과 재실자 온열 쾌적감 연구 (Heat Gains and Occupant′s Thermal Comfort in Computer Room)

  • 김원태
    • 감성과학
    • /
    • 제3권2호
    • /
    • pp.1-8
    • /
    • 2000
  • 본 연구에서는 기존의 공조방식 및 본 연구에 제안된 개별환경제어시스템(PEM)으로부터 재실자가 거주하여 사용하고 있는 컴퓨터룸(CR)에 대해 기하학적으로 3차원 시뮬레이션을 수행하여 CR의 열취득과 재실자 온열 쾌적감을 감성공학적 측면에서 분석하였다. 본 연구로부터 바닥으로부터 공기를 유입하여 천정으로 유출하는 바닥취출공조(TAM)방식이 실내 환경 개선에 유리하고 디퓨저만을 통하여 공기가 유입되어 천정과 바닥으로 공가가 유출되는 개별공조(PEM) 방식은 열적 냉각 성능은 좋으나 컴퓨터와 재실자 주변에 강력한 ㅐ순환 유동을 유인하여 실내 환경의 쾌적감 측면에서는 불리하다. 그러나 PEM과 TAM방식의 결합이 감성공학적 온열특성 분포로부터 CR의 재실자 주변온도 분포에 최적임을 알 수 있다.

  • PDF

저온공조용 취출구의 선정 (Selection of Diffuser for Lower Temperature Air Distribution System)

  • 박성규;유호준;최명신
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.484-492
    • /
    • 2008
  • Air Discharge pattern and even temperature distribution is critical for a successful lower temperature air distribution system, which would supply lower temperature air than normal HAVC system. Selection of appropriate diffuser is the most critical element in completing lower temperature system.

  • PDF

대규모 실내경기장의 동계 온열환경 특성 실측조사 - 인체부하 미고려 조건 - (A Study on the Indoor Thermal Environment of the Large Gymnasium Space in Winter - Without Heat Loads from Occupancy -)

  • 최동호;정성진;석호태
    • 한국공간구조학회논문집
    • /
    • 제7권3호
    • /
    • pp.67-77
    • /
    • 2007
  • 본 연구에서는 기존 대공간의 난방시에 발생될 수 있는 분포상의 문제점을 실측실험을 통해 확인하여, 궁극적으로는 대공간의 열환경 개선과 효율적인 난방설계를 위한 기초데이터를 제시하고자 하였다. 본 연구에서는 인체부하 미고려시의 동절기 대공간의 실내온열환경 실측실험을 비난방시와 난방시로 구분하여 실시하였으며 공간내 수평 및 상하온도분포특성, 취출기류의 거동특성, 실내쾌적온열환경 특성, 환기량 평가 등 대공간의 실내열환경을 포괄적으로 검토하였다.

  • PDF

개별공조에 의한 CR에서의 Heat Gain과 재실자 온열성 연구 (Occupant's Thermal Comfort and Heat Gains in CR by PEM)

  • 김원태
    • 한국감성과학회:학술대회논문집
    • /
    • 한국감성과학회 1999년도 추계학술대회 논문집
    • /
    • pp.13-18
    • /
    • 1999
  • 기존의 공조방식 및 본 연구에서 제안한 개별환경제어시스템(PEM)으로부터 열유체 유동 헤석용 PHOENICS 프로그램을 이용하여 3차원 시뮬레이션을 수행하여 재실자가 거주하고 있는 CR(컴퓨터실)에서의 Heat Gain과 재실자 온열성 특성을 감성공학적 측면에서 분석하였다. 본 연구로부터 바닥으로부터 공기를 유입하여 천정으로 유출하는 바닥취출공조방식이 실내 환경 개선에 유리하고 diffuser만을 통하여 공기가 유입되어 천정과 바닥으로 공기가 유출되는 PEM 방식은 열적 냉각 성능은 좋으나 PC와 재실자 주변에 강력한 재순환 유동이 발생되어 실내 환경의 쾌적성 측면에서는 불리하나 PEM과 TAM방식의 결합이 감성공학적 온열특성 분포로부터 CR실의 재실자 주변 온도 분포에 최적임을 알 수 있다.

  • PDF

대공간내 인체발열 미고려시의 하계 온열환경 조사 (A Study on the Indoor Thermal Environment of the Large Enclosure Without Cooling Loads from Occupancy in Summer)

  • 정성진;최동호;양정훈;석호태
    • 한국공간구조학회:학술대회논문집
    • /
    • 한국공간구조학회 2008년도 춘계 학술발표회 논문집
    • /
    • pp.3-8
    • /
    • 2008
  • 본 연구에서는 기존 대공간의 냉방시에 발생될 수 있는 분포상의 문제점을 실측실험을 통해 확인하여, 궁극적으로는 대공간의 열환경 개선과 효율적인 냉방설계를 위한 기초데이터를 제시하고자 하였다. 본 연구에서는 인체부하 미고려시의 하계 대공간의 실내온열환경 실측실험을 실시하여 공간내 수평 및 상하온도분포특성, 취출기류의 거동특성, 실내쾌적온열환경 특성, 환기량 평가 등 대공간의 하계 실내온열환경을 포괄적으로 검토하였다.

  • PDF