Waterhammer for the Intake Pumping Station with the Pump Control Valve (펌프제어밸브를 사용한 취수펌프장에서의 수격현상)

  • Kim, Kyung-Yup;Oh, Sang-Hyun
    • The KSFM Journal of Fluid Machinery
    • /
    • v.4 no.4 s.13
    • /
    • pp.16-21
    • /
    • 2001
  • The field tests on the waterhammer were carried out for PalDang intake pumping station of the metropolitan water supply 5th stage project. The pumping station was equipped with the pump control valve as the main surge suppression device and the surge relief valve as auxiliary. However, the pump control valve had not been early controlled in the planned closing mode, and the slamming occurred to the valve which abruptly closed during the large reverse flow. Because the pressure wave caused by the pump failure was superposed on the slam surge, the upsurge increased so extremely that the shaft of the valve was damaged. It was desirable that the surge relief valve was installed in the pumping station or near the pump exit for the delay of response. After reforming the oil dashpot of the pump control valve, the sliming disappeared and the measured pressure was in fairly good agreement with the results of simulation. In case of three pumps for ${\phi}2,600$ pipeline being simultaneously tripped, the pressure head in the pumping station increased to 95.6 m, and the upsurge caused by the emergency stop of four pumps for ${\phi}2,800$ pipeline was 89.6m. We concluded that the pumping station acquired the safety and reliability for the pressure surge.

  • PDF

Riverbank Filtration Well Development for Water Source Heat Pumps (시설원예 히트펌프 냉난방용 강변여과수 개발)

  • Cho, Yong;Lee, Nam-Young;Park, Jin-Hoon;Moon, Jong-Pil
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2010.05a
    • /
    • pp.1996-2000
    • /
    • 2010
  • 국내 시설원예 면적은 2005년 기준 52,022ha에 달하고 있으며 약 23%에 해당하는 12,000ha는 겨울철에 난방기를 가동하여 원예작물을 생산하고 있다. 농업용 난방기의 보급은 가온재배 면적의 증가와 더불어 급신장하고 있어 농업용 면세유 중 경유 공급액 약 9,260억원 중 62%에 해당하는 1,350,000톤이 시설원예 난방에 사용된 것으로 추산되고 있다. 지속적인 유가 상승으로 시설재배 농가의 경영이 악화되고 있어 최근 히트펌프를 이용한 냉난방시스템에 대한 연구가 수행되고 있다. 시설원예 냉난방에 사용되는 히트펌프의 열원은 다양하게 적용할 수 있으나 강변에 위치하고 있는 시설원예단지의 경우 연 중 풍부한 유량과 안정적인 수온을 얻을 수 있는 강변여과수는 매우 매력적인 열원이다. 본 연구에서는 시범지역으로 남강댐 하류에 위치하고 있는 진주지역의 시설원예단지와 낙동강 유역의 구미지역 시설원예단지의 두 곳에 대하여 1일 $1,000m^3$의 강변여과수 개발에 대한 조사를 수행하였다. 육안 및 현장여건에 대한 조사를 수행하고 인근 지하수 사용현황에 대한 조사를 실시하였다. 진주지역의 경우 일부 농가에서 지하수를 사용하고 있었으나 1일 8~10시간 취수에 최대 취수량은 약 $120m^3$ 정도였다. 반면, 구미지역의 경우 1999년 구미첨단원예농단 조성사업의 일환으로 양액재배에 농업용수를 공급할 목적으로 지하수 개발이 실시되었으며 최근 인근 국화축제를 개최하는 지역에서 신규로 지하수를 개발하여 사용 중이었다. 전기비저항 탐사를 실시한 결과 진주지역은 지하 약 6~17m 지점에 대수층이 존재하는 것으로 판단되었고, 구미지역은 지하 약 10~20m 지점에 대수층이 존재할 가능성이 있지만 지하 20m 지점부터는 대수층의 가능성이 높은 것으로 판단되었다. 두 지역에 각각 두 공을 시추하여 조사한 결과, 구미지역의 경우 수면높이가 지하 약 10m이고 각각 2.5m와 4.6m의 모래자갈층을 형성하고 있어 $1,000m^3$/일의 취수량 개발이 원활하지 않을 것으로 판단되었다. 한편, 진주지역은 수면높이가 지하 약 3m이고 각각 3.5m와 6.5m의 모래자갈층을 형성하고 있어 $1,000m^3$/일의 취수량 개발이 가능할 것으로 판단되었다. 현장 시추조사 및 기존관정 조사결과, 구미지역에 비하여 진주지역이 지하수 물량 확보가 상대적으로 용이하고 신규 굴착 가능지점이 다수 분포하고 있어 연구지점으로 활용하는데 유리할 것으로 판단되었다. 따라서 진주지역에 여과수열원 확보를 위해 2곳의 양수관정을 설치하고 히트펌프를 이용하여 시설원예의 냉난방을 실시할 예정이다.

  • PDF

Estimation of Hydraulic Status on Intake Structure at Gunsan Combined Cycle Power Plant by Numerical and Physical Model Test (수치모의와 수리모형실험에 의한 군산복합화력발전소 냉각수 취수부 수리현상 검토)

  • Park, Byong-Jun;Song, Hyun-Ku;Hur, Young-Hwoe;Kang, Shin-Wook;Park, Young-Jin
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.1884-1888
    • /
    • 2009
  • 군산복합화력발전소의 냉각수 취수부는 부지 여건상 수로의 길이가 짧고, 좌안이 좁아진 후 단차가 있는 형태에 직각으로 흐름방향이 전환되면서 CWP로 유입되는 구조로 설계되었기 때문에 CWP 운영에 불리한 수리현상이 예상되어 수치모의와 수리모형실험을 통한 사전검증이 필요하였다. 이에 $FLOW-3D^(R)$를 이용한 3차원 수치모의와 축척 1/10의 수리모형실험을 통하여 면밀히 검토한 결과 CWP 진입부의 깊은 수심이 흐름을 감세하여 0.3m/s 이하의 유속분포를 나타내 균등취수에 문제가 없는 것으로 확인되었다.

  • PDF

Numerical Study on the Waterhammer of PalDang Intake Pumping Station (팔당 취수펌프장의 수격현상에 관한 수치해석적 연구)

  • Kim, Kyung-Yup;Yu, Teak-In
    • The KSFM Journal of Fluid Machinery
    • /
    • v.3 no.4 s.9
    • /
    • pp.52-58
    • /
    • 2000
  • The numerical study on the waterhammer was carried out for the intake pumping station of the metropolitan water supply 6th stage project. Because the waterhammer problems as a result of the pump power failure were the most important, these situations were carefully investigated. The surge tank and the stand pipes effectively protected the tunnels md the downstream region of pipeline from the pressure surge. In case the moment of inertia of the pump and motor was above $5080\;kg{\cdot}m^2$, the column separation did not occur in the pipeline between the pumping station and the inlet of 1st tunnel. As the moment of inertia increased, the pressure surges decreased in the pipeline conveying raw water. The pump control valve was chosen as the main surge suppression device for the intake pumping station. After power failure, the valve disc should be rapidly closed in 2.5 seconds and controlled the final closure to 15 seconds by the oil dashpot. If the slamming happened to the pump control valve, there was some danger of this system damaging. As the reverse flow through the valve increased, the upsurge extremely increased.

  • PDF

Draw-down Characteristics of Bank Filtration by Using the Horizontal Collector Well (방사형집수정에 의한 강변여과수 수위하강 특성)

  • Chung Ji Hoon;Park Jae Hyun;Park Chang Kun;Yang Jung Suk
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.240-244
    • /
    • 2005
  • 현재 강변여과수 개발은 수직정 위주로 개발되어졌으나, 수직정을 이용한 취수 방식은 산출량에 대한 한계를 가지고 있어 대용량 취수를 위해서 많은 취수정 착정이 불가피하다. 취수정 증가와 더불어 유지관리상의 문제점을 가지고 있으며 실제 운영에서 문제점이 나타나고 있는 실정이다. 이러한 수직정 취수정의 문제점을 해결하기 위해 방사형 집수정을 이용한 강변여과수 개발이 시도 되고 있다. 현재 창원시 대산면 일대에서 국내최초로 방사형집수정을 이용한 강변여과수 개발이 진행되고 있으며, 현재 방사형 취수정 1기가 시공 완료되어 시험 가동 중에 있다. 방사형 집수정에 의한 강변여과수 개발은 대용량 취수를 목적으로 설치되기 때문에 산출량뿐만 아니라 집수정 인근의 수위하강에 특성이 중요한 요소 중에 하나이다. 본 연구에서는 창원시 대산면 일대에서 진행되고 있는 방사형 집수정 설치에 따른 강변여과수 산출시 집수정 인근 수위하강 특성 파악을 위한 모니터링을 목적으로 실시하였다. 수위하강 특성 관측을 위해 양수실험을 위해 대용량 양수펌프 설치, 유량검증을 위한 대형 웨어 설치, 수위변화 측정을 위해 집수정 30m 반경에 8개의 관측정을 착정하여. 디지털 수위측정기를 설치하여 수위하강 특성을 모니터링 하였다. 수위 모니터링 결과 취수정의 수위하강 특성과 유사하게 수평정의 수위하강 경향 나타났으며, 강변에 가까운 수평정의 수위하강은 약 $30\% 감소하였으며, 집수정 양수량에 변화에 따라 민감하게 반응하지 않는 특성을 나타냈다.

  • PDF

A study of method to refrain from the winding temperature rising of three-phase induction motor (고압전동기 권선온도 냉각설비 개선 사례 연구)

  • Choi, In-Seok;Hong, Jeong-Jo;Lee, Eun-Chun;Hong, Young-Jae;Hong, Hyun-Pyo
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.831-832
    • /
    • 2015
  • K-water에서는 대청댐 하류의 용수를 취수하여 대청광역 계통에 1일 98만㎥을 공급할수 있는 현도취수장을 운영하고 있다. 취수장에는 고압전동기 10대가 운영되고 있으며, 장시간 연속운전 및 하절기 주위온도 상승 등으로 권선온도가 상승되어 설비의 안전성 문제가 제기되어 왔다. 취수펌프동 실내온도 및 고압전동기 권선온도 저감을 위해 펌프동 배기시스템 운영시간 변경 및 고압전동기 냉각 흡기덕트 설치 등의 개선 노력으로 권선온도 저감은 물론 에너지절감 및 기기의 수명연장 등 설비 운영의 안전성을 확보한 연구결과이다.

  • PDF

Estimation of streamflow depletion due to groundwater pumping using analytical solution and empirical formula (해석해와 경험공식을 이용한 하천 인근 지하수 양수에 따른 하천수 감소율 분석)

  • Lee, Jeongwoo;Kim, Nam Won;Chung, Il-Moon;Hong, Sung Hun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.220-220
    • /
    • 2019
  • 천부대수층-심부대수층-하천-양수정 시스템에 대해 개발된 Ward & Lough 해석해와 국내 시험유역을 대상으로 개발된 양수량 대비 하천수 감소량 산정공식 (한강홍수통제소, 2018)을 광주천인근에 실제로 위치한 지하수 관정에 적용하여 지하수 취수로 인해 하천의 수량에 미치는 영향을 분석하였다. 분석 대상관정은 하천에서 약 67 m 떨어진 공업용수 공급을 위한 지하수개발 이용시설로서 착정심도 100 m, 착정구경 150 mm, 취수계획량 $200m^3$/일, 수중펌프 5 Hp 등의 시설제원을 가진다. 해석해 및 경험공식 적용을 위한 기본 입력자료로 투수량계수, 저류계수 등의 수리상수값은 해당 관정의 지하수개발 이용 영향조사서에서 발췌하였고, 측정되지 않은 일부 입력값은 문헌조사를 통해 적절한 값을 가정하여 사용하였다. 하천의 수량에 미치는 지하수 양수 영향을 예측한 결과 지하수 허가기간 5년동안 취수계획량의 약 80 %를 넘는 하천수 감소율이 발생하는 것으로 분석되었다. 연구 대상관정과 같이 하천에 매우 근접한 지역에서 지하수를 이용할 경우 하천수 취수에 준하는 영향을 보일 수 있기 때문에 수자원의 효율적인 이용을 위해서는 하천수와 하천 인근 지하수의 통합적 관리가 필요할 것이다.

  • PDF

Groundwater Intake System Using Wind Energy in Jeju Island (제주지역의 풍력에너지를 이용한 지하수 취수시스템)

  • Kim, Seong-Beom;Go, Jin-Seok;Yeo, Un-Gi;Lee, Seung-Yun;Ji, Hong-Gi
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.1885-1889
    • /
    • 2006
  • 제주지역은 대륙과 해양을 연결하는 요충지로서 한라산을 중심으로 동서사면은 $3{\sim}5^{\circ}$의 완만한 경사를 이루고 있다. 연평균 강우량은 1,975mm로서 국내 최다우 지역이나 제주도의 지질 특성상 도내 대부분의 지역이 투수성이 높은 다공질 현무암으로 구성되어 있는 관계로 지표수의 발달이 미약한 반면 지하수가 풍부하게 부존되어 있으며 기저지하수, 준 기저지하수, 상위지하수, 기반암지하수로 이루어져 있다. 최근 우리나라의 교토의정서 비준으로 인한 온실가스 감축이 불가피함에 따라 대체 재생가능한 에너지를 이용한 풍력발전시대가 도래하고 있으며, 제주 행원풍력발전단지에 설치된 총 15기 발전장치의 현실성과 경제성 입증을 통해 제주지역의 풍력에너지를 이용한 지하수 취수시스템을 제안하였다. 본 연구는 제주, 고산, 서귀포, 성산포지역에 대한 제주지방기상청 연평균 풍속자료$(2004{\sim}2005)$를 통하여 대상지역내 적용 가능한 로터(Roter), 나셀(Nacelle), 타워(Tower), 발전기를 포함한 발전장치를 선정하였으며, 공기역학적(Aerodynamic)특성에서 전기에너지로 변환한 풍력에너지를 지하수 취수시스템으로 적용하기까지의 전력공급절차를 도출하였다. 또한 생산되어진 풍력에너지 용량에 적용 가능한 수중.육상모터펌프를 산정하여 '제주도 지하수개발.이용시설 설치 및 관리기준(2004)'에서 제시한 구조도를 바탕으로 대상지역내 지하수위를 고려한 지하수 취수시스템을 도시하였다. 제주도는 지형 및 지질적인 특성상 수자원을 지하수에 의존할 수밖에 없는 특수한 지역이므로 2002년말 통계를 살펴보면 생활용, 공업용, 농업용으로 각각 57만$m^2$, 11만$m^2$, 56만$m^2$를 포함한 1일 최대 124만$m^2$의 지하수를 사용하고 있다. 따라서 풍력에너지를 이용한 지하수 취수시스템을 도입하여 재생가능한 에너지이용 효과와 세계인이 공감하는 청정한 관광자원으로 활용 가능할 것이라 판단된다.

  • PDF