• Title/Summary/Keyword: 충격 저감

Search Result 256, Processing Time 0.028 seconds

Analysis of Reduction Effect of Inter-Floor Noise Using Active Noise Control (ANC) Technique (능동소음제어 기술을 이용한 층간소음 저감효과 분석)

  • Hojin, Kim;Joong-Kwan Kim;Junhwan Kim;Hyunsuk Kim;Hyuk Wee
    • Journal of Korean Society of Disaster and Security
    • /
    • v.16 no.3
    • /
    • pp.45-56
    • /
    • 2023
  • In this study, the application of ANC (Active Noise Control) technology to address inter-floor noise was explored. To achieve this, an ANC system was developed to manage the heavy impact sound within the frequency range of 40 to 500 Hz. The ANC system utilized an adaptive filter employing a feedforward approach based on the Fx-LMS algorithm. To set up the ANC system, a comprehensive analysis of various variables within the system was performed using computational simulations. This process enabled the identification of optimal filter settings and system configuration arrangements. In addition, the ANC system was implemented in the inter-floor noise test room at the Korea Conformity Laboratories (KCL). Through a certified standard testing procedure, it was confirmed that the ANC system led to a 4 dB reduction in inter-floor noise when the system was activated compared to when it was turned off. The results of this study indicate that the developed ANC system has an effect significant enough to elevate the rating criteria by one level for heavy impact sound.

Reduction of Floor Impact Noise and Impact Force for PVC Floor Covering and Floor Mat (PVC 바닥 마감재와 바닥 매트의 바닥충격음 및 충격력 저감)

  • Mun, Dae-Ho;Song, Guk-Gon;Lee, Cheol-Seung;Park, Hong-Gun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.7
    • /
    • pp.501-508
    • /
    • 2014
  • Floor finishing materials such as floor coverings and floor mats can reduce floor impact noise easily. When an impact was applied to the floor, its finishing material is deformed and the impact force that was applied to the concrete slab is changed. The softer finishing materials were, the more impact force decreased. An experimental study was performed using 14 PVC floor coverings and 16 floor mats to capture the characteristics of impact force and impact noise in the residential buildings. The test results show that the impact force spectrum and the floor impact noise spectrum have a linear relationship in the case of a bare concrete slab, and the characteristics of impact force reduction are the same as those of floor impact noise reduction.

An Analysis of High Speed Impulsive Noise of Rotating Blades Using Frequency Domain Method (주파수 영역 기법을 이용한 회전익의 고속 충격소음 해석)

  • 윤태석;이수갑
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1996.10a
    • /
    • pp.443-449
    • /
    • 1996
  • 헬리콥터, 팬, 프로펠러, 터이빈같이 회전익에서 유체역학적 소음이 발생하는 장치의 설계에 있어서는 공기 역학적 성능 분석과 함께 소음에 대한 해석이 절대적으로 필요하다. 근래에 들어와서 소음에 대한 관심이 급격히 증가하고 공항 주변에서의 국제적인 규약들은 낮은 소음 수준(low noise level)을 규정하고 있으며, 이에 따라서 소음을 감소시키려는 연구가 매우 활발히 진행되고 있는 실정이다. 더욱이 컴퓨터의 냉각 팬을 비롯한 공조기기 및 산업기기에 사용되는 회전기계에서 발생되는 소음의 저감은 보다 더 쾌적한 환경을 요구하는 사회적 요구에 부합하면서 공력소음의 연구 분야가 더 넓어지고 있다. 본 논문에서는 소음예측 방법중의 하나인 음향상사(acoustic analogy)를 주파수 영역 방법(frequency domain method)을 이용하여 헬리콥터 블레이드의 고속 충격소음(High Speed Impulsive Noise)을 해석한다. 고속 충격소음은 블레이드-와류 상호작용 소음과 더불어 헬리콥터의 지배적인 소음원으로서 깃끝 속도가 큰 전진 수평비행(forward level flight)또는 제자리 비행(hovering flight)시 발생하는 소음으로 블레이드의 깃끝 마하수(critical Mach number)보다 크거나 비슷할 경우 충격파의 교란에 의해서 일어나는 충격적인 소음을 말한다. 고속 충격소음은 고주파수 스펙트럼 성분과 큰 소음강도를 가지고 있기 때문에 날카로운 금속성의 소리를 내며 먼 거리까지 전파되는 특징을 가지고 있다.

  • PDF

Diminution of birdge vibration for high-speed trains (고속철도 교량의 진동저감)

  • Choi Eun-Suk;Chin Won-Jong;Lee Jung-Woo;Kwark Jong-Won;Kang Jae-Yoon;Kim Byung-Suk
    • Journal of the Korean Society for Railway
    • /
    • v.9 no.1 s.32
    • /
    • pp.125-130
    • /
    • 2006
  • 고속철도 교량구간에 차량(KTS)이 주행할 경우 교량 바닥판에서는 큰 가속도 응답이 계측된다. 이러한 가속도의 원인으로는 큰 단면의 국부 진동, 일정한 간격의 침목의 충격 그리고 차량 자체의 진동 등 여러 가지 원인이 있다. BRDM(Bridge Design manual)에서는 이러한 동적 특성치들에 대한 제한치를 규정하고 있는데, 가속도인 경우는 0.35G이하고 규정하고 있다. 실교량 실험에 의해 계측된 가속도 응답은 규정한 제한치인 0.35G 보다는 작지만, 이러한 가속도 응답치들은 차량이 고속으로 주행할 경우 안전성에 문제를 일으킬 수 있다. 본 논문에서는 큰 단면에서 과도한 국부 진동을 지배하는 가속도 응답을 줄이기 위해서 진동저감 방법을 연구하였다. 비록 휨이나 비틀림 같은 전체 진동모드에는 효과가 작지만 일반적으로 매우 큰 단면을 가진 고속철도 프리스트레스트 상자형 교량의 국부진동인 날개짓 모드를 감소시키는데 진동저감 장치는 효과적이라고 판단된다. 실교량에서 진동저감장치의 실험은 추후 연구를 수행할 예정이다.

Vibration Reduction Effect and Structural Behavior Analysis for Column Member Reinforced with Vibration Non-transmissible Material (진동절연재로 보강된 기둥부재의 진동저감효과 및 구조적 거동분석)

  • Kim, Jin-Ho;Yi, Na-Hyun;Hur, Jin-Ho;Kim, Hee-Kyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.4
    • /
    • pp.94-103
    • /
    • 2016
  • For elevated railway station on which track is connected with superstructure of station, structural vibration level and structure-borne-noise level has exceeded the reference level due to structural characteristics which transmits vibration directly. Therefore, existing elevated railway station is in need of economical and effective vibration reduction method which enable train service without interruption. In this study, structural vibration non-transmissible system which is applied to vibroisolating material for column member is developed to reduce vibration. That system is cut covering material of the column section using water-jet method and is installed with vibroisolating material on cut section. To verify vibration reduction effect and structural performance for structural vibration non-transmissible system, impact hammer test and cyclic lateral load test are performed for 1/4 scale test specimens. It is observed that natural period which means vibration response characteristics is shifted, and damping ratio is increased about 15~30% which means that system is effective to reduce structural vibration through vibration test. Also load-displacement relation and stiffness change rate of the columns are examined, and it is shown that ductility and energy dissipation capacity is increased. From test results, it is found that vibration non-transmissible system which is applied to column member enable to maintains structural function.

Influence of Chemical composition of Ethylene-Vinyl Acetate Copolymers on Impact Noise Damping of Composites (에틸렌-초산비닐 공중합체의 공중합 조성이 복합체의 충격음 흡수성능에 미치는 영향)

  • 이현종
    • Journal of Korea Foresty Energy
    • /
    • v.18 no.2
    • /
    • pp.55-61
    • /
    • 1999
  • This study was carried out to investigate the influence of viscoelastic properties(or chemical composition) of a series of ethylen-viny1 acetate copolymers on impact noise and vibration damping of wood/polymer/wood sandwich composites. The impact noise and vibration damping of composites were very sensitive to the state of molecular motion of polymer. The noise and vibration damping of composites were maximum when the polymer was under the glass transition(vinylacetate 55~75%) at the test-temperature, and minimum rubbery state(vinyl-acetate 47~20%) or glassy state(vinylacetate 100~87%). The polymer under glass transition reduced the impact noise by 6~12 dB.

  • PDF

Damage estimations of the real water distribution system based on reliability analysis (신뢰성해석을 통한 실제 상수도관망의 피해 분석)

  • Kwon, Hyuk Jae;Kim, Hyeong Gi
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.290-290
    • /
    • 2018
  • 본 연구에서는 수충격으로 발생할 수 있는 실제 상수도관망의 피해율을 신뢰성해석을 통해 정량적으로 비교분석하였다. 이를 위해서 먼저 실제 상수관망에 대한 수충격해석을 수행하였는데 기존의 가압장 운영조건을 적용하였고 가압장의 선택운영조건을 변경하여 수충격해석을 수행하였다. 이 결과물을 토대로 신뢰성해석을 수행하였고 두 조건에 대하여 정량적인 파괴확률을 산정할 수 있었다. 본 연구에서 사용된 실제 상수관망은 가압장의 운영조건으로 24시간 75m 수두를 유지하고 있으며 관말단부의 수용가에 충분한 유량이 전달되고 있다. 가압장의 고압유지는 관말부에는 적정할 수 있으나 상수도관망에서 누수와 시설물에 대한 많은 피해를 유발할 수 있다. 따라서 본 연구에서는 가압장의 펌프압력수두를 75m와 65m로 선택적 운영을 가정하였다. 이로 인한 관말부의 압력이 수도압력으로 충분한 15m를 계속 유지하는 것을 확인하였으며 수돗물 사용량이 적은 야간에는 가압장의 수두를 낮추는 방법으로 선택적 운영조건을 사용하였다. 기존 가압장의 운영조건과 선택적 운영조건을 사용하여 수충격해석을 수행하였고 신뢰성 해석모형을 사용하여 파괴확률을 정량적으로 산정할 수 있었다. 가압장의 운영조건을 최적화하여 효율은 증대하고 피해율을 저감할 수 있는 방법을 찾을 수 있었다, 이를 위해서 가압장의 인버터 설치는 물론이고 펌프의 최적운영을 위한 프로그램을 장착하여 가압장을 운영한다면 보다 경제적인 운영이 될 수 있을 뿐만 아니라 실제 상수관망에서 발생할 수 있는 여러 가지 피해를 최소화할 수 있을 것으로 판단된다.

  • PDF

The Effects of Energy Price Increase on Automobile Industry (에너지가격 상승이 자동차산업에 미치는 영향)

  • Kim, Younduk;Han, Hyun-Ok
    • Journal of Environmental Policy
    • /
    • v.11 no.3
    • /
    • pp.97-122
    • /
    • 2012
  • This article analyzes the effects of energy price increase induced by GHGs mitigation policy on automobile industry empirically. An increase in energy price due to GHGs mitigation policy does not have a significant effect on the production and the value-added in automobile industry. Electricity price has a negative effect on the production and the value-added in automobile industry, but it is not significant. However, employment is significantly affected by a change in electricity price. Export is also affected negatively, but the effect is insignificant. These results imply that GHGs mitigation policy such as carbon tax might affect adversely the employment in automobile industry. Especially, their effects on employment are significant. Therefore, some moderating measures to relieve the adverse effects on employment in automobile industry should be called upon with the implementation of GHGs mitigation policy.

  • PDF

A Study on Floor Impact Sound due to Resilient Materials in Apartment Buildings (공동주택의 소음 저감재 설치로 인한 바닥 충격음에 관한 연구)

  • 김병길;김수련;곽규성;오상근
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2004.05a
    • /
    • pp.5-10
    • /
    • 2004
  • Apartment Buildings have particularity to cluster together, especially, floor is close to resident, it is subject to dissatisfaction about impact noise between up and down floors. However, we require standard for counterplan to reduce the impact noise of floor. In point of fact, it difficult to objective evaluate for performance sound insulation that not physical sound volume but orignal form, means and effect of sound caused to complex noise in apartment house. Unique type of dwelling and structure pattern cause to noise of floor impact which is established by law for standard regulation. It is object to analysis and compare the result of performance sound insulation of upper floor impact and sample construct the subject resilient material of sound insulator

  • PDF

Modeling impact force and transfer function for reducing relay impact noise (릴레이 충격 소음 저감을 위한 충격력과 전달함수 모델링)

  • Kim, Koo-Hwan;Kim, Yang-Hann
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.646-649
    • /
    • 2008
  • This study deals with mechanism of relay operation and modeling of transfer function between impact force and sound pressure due to the impact force in order to reduce relay noise. A collision between a moving-contact and fix-contact produces impact noise. Therefore impact noise of relay is determined by not only excitation force but also transfer function from impact force to noise. In this study, we find mechanism of relay operation, make impact force model and measure characteristic of relay noise. And also we find transfer function of relay noise.

  • PDF