• Title/Summary/Keyword: 출구 유량

Search Result 262, Processing Time 0.042 seconds

CFD Analysis on the Flow Uniformity of a $CO_2$ Enrichment System (CFD를 이용한 온실 $CO_2$ 시비 시스템의 유량 균일성 해석)

  • Yim, Kyungjin;Kim, Hongjip;Lee, Sangmin;Park, Kyoung-Sub
    • Journal of Bio-Environment Control
    • /
    • v.22 no.2
    • /
    • pp.123-130
    • /
    • 2013
  • $CO_2$ enrichment systems have been recently used to shorten the growth period of plants and the improvement of harvest and its quality. To accomplish these goals, manifold should be designed to supply the same amount of $CO_2$. In this study, CFD approach has been used to understand the effects of geometric parameters, such as tube and hole diameters. An optimized geometry has been derived through pipe and tube part, respectively. As a result, the deviation of flow rate less than 0.1 g/s was expected at all holes of the $CO_2$ enrichment system.

Prediction Equation of Solar Collector Outlet Air Temperature (태양열(太陽熱) 집열기(集熱器) 출구온도(出口温度) 예측방정식(豫測方程式))

  • Moon, Soung Hong
    • Journal of Biosystems Engineering
    • /
    • v.10 no.1
    • /
    • pp.48-53
    • /
    • 1985
  • 농산물 건조를 위하여 평판형 태양열 집열기를 이용할 경우 가열된 출구공기는 각종 농산물건조적온보다 일반적으로 고온이므로 이의 조절을 위한 출구공기 온도의 예측이 중요시 된다. 본 연구에서는 차원해석법(dimensional analysis)을 이용하여 평판형 집열기의 출구에서 나오는 가열된 공기의 온도를 예측하는 방법이 제시되었으며, 이 방법을 이용하여 집열기의 출구공기온도 예측방정식들이 유량별로 유도되었다. 이 방정식들로부터 구한 출구온도들은 실측한 값들과 잘 일치하였으며($R^2$=0.917~0.957) 또한 집열기의 효율을 나타내는 이론식이 출구공기온도 예측방정식으로 부터 직접 유도되었다.

  • PDF

An Experimental Study on Flow Characteristics of Cavitation Venturi (캐비테이션 벤츄리의 유동 특성에 대한 실험적 연구)

  • Yoon, Wonjae;Ahn, Kyubok
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.19 no.4
    • /
    • pp.1-7
    • /
    • 2015
  • A cavitation venturi is a device that allows a liquid flow rate to be fixed or locked independent of a downstream pressure and has been successfully used in a liquid rocket engine system which requires a stable propellant flow rate. In the present research, four cavitation venturis which have same dimensions except for converging inlet angle and diverging outlet angle, were designed and manufactured. Flow rates through each venturi and upstream/downstream pressures were measured by changing the pressures. From the experimental data, the discharge coefficients and critical pressure ratios were calculated for each venturi. It was found that the inlet and outlet angles of the cavitation venturi affected the discharge coefficient, and the outlet angle influenced on the critical pressure ratio.

원자로 냉각재계통 RTD SCOOP내부 유속계산

  • 윤덕주;이창섭
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.42-47
    • /
    • 1996
  • 기존의 우회배관을 제거하고 원자로냉각재배관에 직접 RTD를 삽입하여 온도를 측정할 경우 취수부내의 유속이 기존에 비해 어떻게 변하는지 고찰하고자 한다. 이는 RTD응답시간 요건을 만족하기 위해서는 RTD SCOOP 내부유속이 3ft/sec이상이 되어야만 하기 때문에 중요하다. 이러한 유속을 계산하기 위해 취수부를 단순화하고 보수적인 가정에 의해 유체역학적으로 계산한 결과 이러한 요건을 만족하는 결과를 얻을 수 있었다. 또한 흡입구와 출구 Hole에서 차압의 대부분이 발생하므로 이부분의 부차계수가 유량계산에 절대적으로 영향을 미치고 있으며 아울러 원자로냉각재유량의 크기에 따라 미치는 영향을 계산한 결과 거의 비례적으로 증가하고 있으며 출구직경을 확대하므로 유량을 3.5 ft/sec까지 증가시킬 수 있다는 결과를 얻었다.

  • PDF

Flow Characteristics of Central-Driven Ejector with Design Parameters (중앙구동 이젝터의 설계변수에 따른 유동특성)

  • Park, Sang Kyoo;Yang, Hei Cheon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.8
    • /
    • pp.645-651
    • /
    • 2015
  • The objective of this study is to experimentally investigate the effect of design parameter on the mass ratio of a central-driven ejector. The design parameters are the primary nozzle area and distance ratios, diffuser exit-area ratio and mixing-tube length ratio. The experimental setup was an open-loop continuous circulation system which has a movable nozzle ejector, an electric motor-pump, a water tank, a control panel and high-speed camera unit. We calculated the mass ratio using the measured primary and suction-flow rates with the experimental parameter of primary water-flow rate or pressure. The results showed that the mass ratio increased with the primary nozzle distance ratio and mixing tube length ratio, while the mass ratio decreased with the primary nozzle-area ratio and diffuser exit-area ratio.

공기 유량의 시간 변화에 따른 $U_3O_8$ 타원입자에 대한 거동 특성 해석

  • Kim, Yeong-Hwan;Jeong, Jae-Hu;Lee, Hyo-Jik;Park, Byeong-Seok;Yun, Ji-Seop
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2007.11a
    • /
    • pp.305-306
    • /
    • 2007
  • ACP(Advanced Spent Fuel Conditioning Process)의 금속전환로에 $U_3O_8$을 공급하기 위하여 20 kgHM/batch의 $UO_2$ 펠릿(pellets)을 처리할 수 있는 건식분말화 장치가 개발되고있다. 건식분말화 장치는 500 $^{\circ}C$온도에서 공기를 공급하여 일정한 입도범위의 균질한 $U_3O_8$을 만든다. 이런 건식 분말화 장치의 효율을 높이기 위해서는 반웅로에 불어 넣어주는 공기의 유량을 증가시킬 필요가 있다. 하지만 공기와 반응하여 생성되는 $U_3O_8$ 입자는 그 크기가 최소 3 ${\mu}$m 정도로 매우 미세하여,반응로 출구를 통해 외부로 빠져나갈 가능성 이있다. 이를 방지하기 위해 분말화 장치 출구 바깥에는 필터가 설치되어 있으나 공기와 함께 $U_3O_8$ 입자가 계속해서 빠져 나갈 경우 입자로 인해 필터가 막혀 제 기능을 할 수 없게 된다. 따라서 건식 분말화 장치는 미세한 $U_3O_8$ 입자가 반응로 밖으로 빠져나가지 않도록 입구에서의 공기 유량을 일정 수준 이하로 조절해주는 것이 필요하다. 이 연구의 목적은 초기 유량으로부터 유량을 점점 증가시키면서 시간변화에 따른 입자 거동 특성을 해석하며, 결과로부터 주어진 크기의 타원입자에 대해 최대 허용 공기 유량을 결정하고자한다. 이 해석을 위해 유동과 입자를 동시에 해석할 수 있는 ANSYS-CFX 5.7.1과 ANSYS-CFX 10.0 두 가지의 소프트웨어가 사용되었다. 해석 결과를 바탕으로 좀더 정확한 유량 한계치 계산을 위해 추가로 수행되어야 할 해석에 대해 제안하였다.

  • PDF

Numerical Investigation of the Performance of a Heat Exchanger for the Inlet-outlet Area Ratio of Counter Flow Manifold (대향류 매니폴드 입-출구 면적비에 따른 열교환기의 성능특성에 관한 수치적 연구)

  • Kim, Sang-Jo;Chio, Byoung-Ik;Kim, Kui-Soon;Son, Chang-Min;Ha, Man-Young;Jeong, Ji-Hwan;Go, Jeong-Sang
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.269-273
    • /
    • 2011
  • In present paper focused on the influence of the inlet-outlet area ratio of counter flow manifold on the flow distribution and pressure drop characteristics of a tubular heat exchanger. The characteristics of flow distribution and pressure loss can be obtained depending on the inlet-outlet area ratio. In this paper, a tubular heat exchanger can be designed with minimum flow mal-distribution and better characteristic of pressure loss by choosing the optimum inlet-outlet area ratio.

  • PDF

Estimation of Natural Flow in Han river basin (한강유역의 자연유량 산정)

  • Kim, Nam-Won;Lee, Jeong-Eun;Won, Yoo-Seung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.799-803
    • /
    • 2006
  • 국내 유량자료는 아직 장기간의 유출량 자료가 확보되어 있지 못하며, 미계측 유역에서의 유출량에 대한 해결책이 마련되어 있지 못한 실정이다. 따라서 국가 수자원 계획이나 효율적인 물관리를 위한 장기유출해석을 위해 유출모형이 사용되고 있다. 본 연구에서는 한국건설기술연구원에서 개발한 SWAT-K 모형을 이용하여 팔당댐 지점을 최종출구점으로 하는 한강유역의 자연유출량을 산정하고자 하였다. 여기에서는 유역내 인위적인 저류시설물인 댐이 없는 상태를 자연유량이 가정하고 팔당댐 지점에서의 자연유량을 산정하여 그 결과를 검토하였다. 대상유역으로 선정된 한강유역(팔당댐 상류유역)의 경우, 유역내 다목적댐, 용수전용댐, 발전전용댐 등 다수의 댐이 위치하고 있다. 기존 사용되어 오고 있는 집중형 모형으로는 대상유역 내의 댐을 고려할 수 없으며, 유역출구점에서의 유출량만을 모의할 수 있다. 그러나, SWAT-K 모형은 유역내 댐고려가 가능한 저수지 모듈을 포함하고 있으며, 유역내 사용자가 원하는 지점에서의 유출량을 모의할 수 있다. 먼저 자연유량을 산정하기 앞서, 댐이 위치하고 있는 대상유역에 대하여 모형에서 고려할 수 있는 댐운영 방법별로 모의유량과 관측유량을 이용하여 댐운영 모의능력을 검증하였다. 또한, 대상유역의 최종출구점인 팔당댐 지점과 유역내에 위치하고 있는 댐지점에 대하여 각각 관측유량과 모의유량을 비교 검토하여 모형의 적용성을 확인할 수 있었다. 따라서, 최종적으로 보정된 매개변수를 이용하여 댐이 없는 상태의 한강유역에 대하여 자연유량을 산정하여, 팔당댐 지점을 중심으로 댐의 유무에 따른 유량의 변화를 고찰하였다. 시범수행에서는 10개의 트렌치를 설치하여 그 효과를 분석하였다. 9번 소유역 145번 지점의 유황을 분석한 결과 저수량$(Q_{275})$$0.0177m^3/s$에서 $0.0190m^3/s$로, 갈수량$(Q_{355})$$0.0176m^3/s$에서 $0.0189m^3/s$로 약 7%가 증가하는 것으로 분석되었다. 결과로부터 침투 트렌치는 저수량 및 갈수량을 증가시키는 보조수단이 될 수 있다.해 보았다. 뿐만 아니라 이와 관련된 수문요소기술을 확보할 수 있을 것이다.역의 물순환 과정을 보다 명확히 규명하고자 노력하였다.으로 추정되었다.면으로의 월류량을 산정하고 유입된 지표유량에 대해서 배수시스템에서의 흐름해석을 수행하였다. 그리고, 침수해석을 위해서는 2차원 침수해석을 위한 DEM기반 침수해석모형을 개발하였고, 건물의 영향을 고려할 수 있도록 구성하였다. 본 연구결과 지표류 유출 해석의 물리적 특성을 잘 반영하며, 도시지역의 복잡한 배수시스템 해석모형과 지표범람 모형을 통합한 모형 개발로 인해 더욱 정교한 도시지역에서의 홍수 범람 해석을 실시할 수 있을 것으로 판단된다. 본 모형의 개발로 침수상황의 시간별 진행과정을 분석함으로써 도시홍수에 대한 침수위험 지점 파악 및 주민대피지도 구축 등에 활용될 수 있을 것으로 판단된다. 있을 것으로 판단되었다.4일간의 기상변화가 자발성 기흉 발생에 영향을 미친다고 추론할 수 있었다. 향후 본 연구에서 추론된 기상변화와 기흉 발생과의 인과관계를 확인하고 좀 더

  • PDF

The Formation of Missing Data through Heavy Rain Damage of the Hydrological Gauging Instrument (수문관측기기 호우피해에 따른 결측자료의 생성)

  • Kim, Dong-Phil;Lee, Dong-Ryul
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.305-309
    • /
    • 2012
  • 한국건설기술연구원의 주요사업인 "산지하천 유역의 홍수예측을 위한 수문조사(2011~2015년)"의 Test-bed 유역중의 하나인 설마천 유역(경기도 파주시 적성면)의 중류부에 위치한 사방교 수위관측소는 2011년 7월 중부지방의 집중호우에 의해 수위관측소가 유실되는 초유의 사태가 발생한 바 있다. 이에 따라 수위관측기기와 부대시설물이 모두 피해를 입었으며, 그 이후 수위관측소 운영이 중단되었다. 다만 유역출구인 전적비교 수위관측소는 일부분 피해가 있었으나, 정상적인 기능을 유지하여 결측이 없는 운영이 이루어졌다. 2011년 사방교 수위관측소의 수위관측 자료는 호우피해 발생 이전 관측자료 수집이 이루어진 2011년 7월 8일 13:30분까지 자료가 있으며, 그 이후는 호우피해에 의한 관측기기의 유실로 모두 결측이다. 따라서 본 연구는 2011년 7월 8일 13:30분 이후 관측이 이루어지지 못한 사방교 수위관측소의 유량자료를 모의 생성한 후 유역출구인 전적비교 수위관측소의 유량자료와 상 하류 유량 및 유출률 검토를 통하여 미관측기간의 결측자료를 최종 생성하였다. 최종 모의 생성된 유량자료는 2011년 이전의 유역의 수문학적 특성과 매우 유사한 경향을 보이므로 모의 생성된 결과는 매우 양호한 것으로 판단된다. 이러한 결과는 설마천 유역의 지속적인 운영과 아울러 6개 우량관측소의 우량자료와(2011년 7월 집중호우에 의해 1개 우량관측소 유실 발생), 유역출구인 전적비교 수위관측소의 신뢰성 높은 수위, 유량자료가 있었기에 가능한 일이다. 설마천 유역 수문자료는 홈페이지(http://seolmacheon.kict.re.kr)와 동시에 운영되는 '설마천-차탄천 수문정보시스템'을 통해 유역정보 및 자료를 저장하고 있으며, 제공을 통해 자료를 공유하고 있다.

  • PDF

Experimental Study on the Energy Separation of the Vortex Tube for EGR Cooler (EGR Cooler 대체용 Vortex Tube의 에너지 분리 현상에 관한 실험적 연구)

  • Kim, Chang-Su;Park, Sung-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.1
    • /
    • pp.55-60
    • /
    • 2010
  • Vortex tube is the device that can separate small particles from the compressed gas, as well as compressed gas into hot and cold flow. Due to energy separation ability, a vortex tube can substitute for an EGR cooler of the automotive engine. In this study, experimental approach has been performed to analyze the energy separation characteristics of the vortex tube. Energy separation characteristics of the vortex tube has been tested for supply pressure, cold-out pressure, and hot-out pressure. As increasing supply pressure, energy separation effect increased. Maximum temperature exists about 0.85 of the cold-out-flow-ratio, and minimum exists about 0.35. Hot-out temperature of the vortex tube is affected by the hot-out and cold-out pressure. However, for the given conditions, cold-out temperature is independent of exit pressure change. The results from this study can be used for the basic design parameter of the EGR cooler substitute of an automotive engine.