• Title/Summary/Keyword: 축전지

Search Result 218, Processing Time 0.023 seconds

Characteristic of VSI Driven by Source Synchronous Type for the Utility Interactive using a Photovoltaic Generation for the LED Luminaire Emergency Exit Sign Operation (LED 비상 유도등 동작을 위한 태양광발전 계통연계 전원동기 방식의 전압형 인버터 구동 특성)

  • Hwang, Lark-Hoon;Na, Yong-Ju
    • Journal of Advanced Navigation Technology
    • /
    • v.22 no.5
    • /
    • pp.420-428
    • /
    • 2018
  • In this paper, represented uninterruptible power supply (UPS) equipment maintaining constant output voltage, the proposes a photovoltaic system constructed with a step up boosting chopper and single phase pulse width modulation (PWM) voltage source inverter. as power source disconnection, voltage variation and output current variation with load variation. This system is driven by being synchronized voltage fed inverter and AC source, and in the steady state of power source charge battery connected to DC side with solar cell using a Photovoltaic that it was so called constant voltage charge. It can be results of saving electric power, and through a normal operation of energy storage system (ESS), the system operated the LED a calling on signal changes at the airport in an efficient manner. In addition, better output waveform was generated because of PWM method, and it was proved to test by experiment maintained constant output voltage regardless of AC source disconnection, load variation, and voltage variation of AC power source.

A Study on the Performance Characteristics of an Energy Saving Unit in a Hydraulic Elevator (유압식 엘리베이터 에너지 저감장치의 성능특성에 관한 연구)

  • Cho, Ihn-Sung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.6
    • /
    • pp.2588-2595
    • /
    • 2013
  • In a traditional hydraulic elevator, elevator car is descended by down control valve, and the oil hydraulic energy must be lost during the descending stroke. In this paper, the performance characteristics of the hybrid type energy saving unit, is used to save the hydraulic energy which is lost during the descending stroke, for a hydraulic elevator are studied. The energy can be reused as the auxiliary power. The results show that the performance characteristics, such as the pressure, flow rate, output current and voltage, efficiency, and the energy recovery rate of the unit are stable and good as the energy recovery rate is 54%, and the energy saving unit is useful to reuse the saved energy during the descending stroke of elevator car. Also, it was confirmed that the energy saving unit can be deployed on a commercial scale.

A study on RFID Middleware protocol for management of sensor node and network implementation in Ubiquitous environment (유비쿼터스 환경에서 센서 노드의 관리와 망 구성을 위한 RFID 미들웨어 프로토콜에 관한 연구)

  • Choi, Yong-Sik;Kim, Sung-Sun;Shin, Seung-Ho
    • Journal of the Korea Society of Computer and Information
    • /
    • v.12 no.3
    • /
    • pp.155-163
    • /
    • 2007
  • In this paper, Though sensors of Ubiquitous Middle-ware System based on RFID/USN can usually be reacted from six mouths to two years, they can be exhausted their power of storage battery only one day by communication rates and ranges. That is, the lifetime of sensor node is depended on how much spending power under wireless communication that can communicate its sensing data to its destination. Therefore, it is necessary that each sensor should be designed the Routing path to its destination, in order to remote collecting data. But, in order to improve lifetime of sensor node and modify inner setting, it is opposite to simple searching path method of sensor node by entering external commands. accordingly, 1:n sensor arrangement of n form command and data send-receive that is possible simulation do without interference other sensors and research to different sensor data analysis and conversion ways to convert Sensing data that accept from sensors to actuality information.

  • PDF

Magnetic Induction Communication System for Electric Vehicle on Smart Grid (스마트 그리드 전기자동차를 위한 자기장 통신 시스템 구현 연구)

  • Lee, Jong-Min;Chang, Woo-Hyuk;Jung, Bang-Chul
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.9B
    • /
    • pp.1381-1389
    • /
    • 2010
  • The smart grid technology is expected to significantly improve energy efficiency by dynamic power supply. One of its application is the Vehicle-to-Grid(V2G) that utilizes an electric vehicle's battery as a household storage battery. Meanwhile, a lot of researches are recently investigated in the area of wireless energy transfer technology because of its convenience and safety in charging a battery. With the wireless energy transfer infrastructure a wireless magnetic induction communication technique can help the dynamic power supply of the smart grid more efficient. In this paper, we propose a wireless magnetic induction communication sion cowhich includes data transmission and location-aware functions. We expect the sion cohelp the smart grid to control power supply more efficiently. We also developed its test-bed and evaluated the performance.

Solar Power Emotional LED Lightening Street Lamps with Multiple Control Sun Tracker (다중 추적식 태양광 발전 감성형 LED 가로등)

  • Lee, Jae-Min;Kim, Yong;Bae, Cheol-Soo;Kwon, Dae-Sig
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.2
    • /
    • pp.920-926
    • /
    • 2011
  • In this paper, a solar power emotional LED lightening street lamps with multi control sun tracker is presented. The proposed system has a multiple control sun tracking function and high quality emotional LED lamps. The system is designed to absorb maximum sun lights by temperature sensor and humidity sensor of control circuits. A battery charge-discharge controller is developed for high efficient usage of battery charger for utilization of new and renewal energy. An interface circuit for remote monitoring and controlling is included in the developed system. The proposed multi tracking solar power emotional LED street lamps is better than conventional systems in aspect of tracking operation and energy efficiency, and expected to be a leading model for next generation solar power street lamp system, because it is a new technology combining sun tracking solar power system and emotional lightening system.

Development of Hybrid BMS(Battery Management System) Algorithm for Lead-acid and Lithium-ion battery (연축전지와 리튬이온전지용 하이브리드 BMS 알고리즘 개발)

  • Oh, Seung-Taek;Kim, Byung-Ki;Park, Jae-Beom;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.5
    • /
    • pp.3391-3398
    • /
    • 2015
  • Recently, the large scaled lead-acid battery is widely introduced to efficient operation of the photovoltaic system in many islands. but the demand of lithium-ion battery is getting increased by the operation of wind power and replacement of the lead-acid battery. And also, under the renewable portfolio standard(RPS) and energy efficiency resource standard(EERS) policy of Korea government, the introduction of energy storage system(ESS) has been actively increased. Therefore, this paper presents the operation algorithm of hybrid battery management system(BMS) using the lead-acid and lithium-ion batteries, in order to maximize advantage of each battery. In other words, this paper proposed the algorithm of state of charge(SOC) and hybrid operation algorithm to calculate the optimal composition rate considering the fixed cost and operation cost of each battery. From the simulation results, it is confirmed that the proposed algorithms are an effective tool to evaluate SOC and to optimally operate hybrid ESS.

Characteristic PCS of Inverter by Boost Converter of PV Generation (태양광 발전 부스트 컨버터를 이용한 인버터 PCS 특성)

  • Hwang, Lark-Hoon;Na, Seung-kwon;Oh, Sang-hak
    • Journal of Advanced Navigation Technology
    • /
    • v.22 no.6
    • /
    • pp.654-664
    • /
    • 2018
  • In this paper, this system is operated by PCS that is driven by being synchronized voltage fed inverter and AC source, and in the steady state of power source charge battery connected to DC side with solar cell using a photovoltaic (PV) that it was so called constant voltage charge. it can cause the effect of energy saving of electric power, from 10 to 20%. and through a normal operation of electric energy storage system (EESS). In addition, better output waveform was generated because of pulse width modulation (PWM) method, and it was Proved to test by experiment maintained constant output voltage regardless of AC source disconnection, load variation, and voltage variation of AC power source.

Attractiveness of Festivals Affect Satisfaction and Images of the Region -Focused on Anseong Namsadang Baudeogi Festival- (축제 매력성이 만족과 지역이미지에 미치는 영향 연구 -안성 바우덕이 축제를 중심으로-)

  • Chun, Min-Ho
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.12
    • /
    • pp.1017-1025
    • /
    • 2013
  • As various types of regional festivals are contributing to the growth of local economy, promoting the culture, and enhancing the region's images, representative festivals are getting more important for local governments. This study analyzed the correlation between satisfaction on festivals' attractiveness and images of the region, based on an actual field study taken with respondants who visited 2012 Anseong World's Folkloriada Festivals. Among various facets that affect festivals' attractiveness, 4 factors such as services aside from transportation and promotional guides, programs, convenient facilities, and food significantly affected tourists' satisfaction level. Tourists' satisfaction level was found to have significant impact on the enhancement of local images. Based on these findings, this paper suggests implications and limitation of the research as well as future directions for the study.

Studies on the Active Materials of Alkaline Storage Battery. On Cadmium Electrode (알칼리 축전지의 활물질에 관한 연구. 카드뮴 전극에 관하여)

  • Ju Seong Lee;Choong Yeoul Joo;Park, Su Gil
    • Journal of the Korean Chemical Society
    • /
    • v.25 no.5
    • /
    • pp.325-330
    • /
    • 1981
  • The electrochemical behavior of cadmium electrode for the nickel-cadmium battery system has been studied by cyclic voltammetry, controlled potential electrolysis and X-ray diffraction method. Cathodic polarization curve for cadmium hydroxide electrode prepared by electrochemical pretreatment of metallic cadmium showed two peaks. It has been found that cadmium hydroxide was reduced to cadmium metal at the first peak potential, whereas very activated metal of cadmium which was strongly oriented (002) rather than (101) was formed at the second peak potential. It was also found that the cadmium formed at the second peak potential reacted rapidly with oxygen. Therefore, it could be presumed that the cadmium recombination reaction with the oxygen was chemical, and could be represented as $2Cd + O_2 + 2H_2O\;{\longrightarrow}\;2Cd(OH)_2$.

  • PDF

Analysis of Battery Performance Test for DC Power System in Nuclear Power Plant (원자력발전소 직류전원계통용 축전지 성능시험 분석)

  • Kim, Daesik;Cha, Hanju
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.2
    • /
    • pp.61-68
    • /
    • 2014
  • Function of battery bank stores energy for DC load in general, and DC power system of the nuclear power plant is used to supply DC loads for safety- featured instrumentation and control such as inverter, class 1E power system control and indication, and station annunciation. Class 1E DC power system must provide a power for the design basis accident conditions, and adequate capacity must be available during loss of AC power and subsequent safe shutdown of the plant. In present, batteries of Class 1E DC power system of the nuclear power plant uses lead-acid batteries. Class 1E batteries of nuclear power plants in Korea are summarized in terms of specification, such as capacity, discharge rate, bank configuration and discharge end voltage, etc. This paper summarizes standards of determining battery size for the nuclear power plant, and analyzes duty cycle for the class 1E DC power system of nuclear power plant. Then, battery cell size is calculated as 2613Ah according to the standard. In addition, this paper analyzes performance test results during past 13 years and shows performance degradation in the battery bank. Performance tests in 2001 and 2005 represent that entire battery cells do not reach the discharge-end voltage. Howeyer, the discharge-end voltage is reached in 14.7% of channel A (17 EA), 13.8% of channel B (16 EA), 5.2% of channel C (6 EA) and 16.4% of channel D (19 EA) at 2011 performance test. Based on the performance test results analysis and size calculation, battery capacity and degradation by age in Korearn nuclear power plant is discussed and would be used for new design.