• Title/Summary/Keyword: 축산폐수

Search Result 317, Processing Time 0.03 seconds

Initial Study on Behavior of Microorganisms in livestock Wastewater (축산폐수 미생물의 초기적 동정 연구)

  • 김태진;서종원;김진경;김종철;정태훈
    • KSBB Journal
    • /
    • v.16 no.4
    • /
    • pp.430-434
    • /
    • 2001
  • Microorganisms of livestock wastewater were microscopically examined to identify bacillus types with optimal absorbance at 630 nm. Growth cuties of microorganisms at various levels of livestock wastewater (5, 10, 20, 30, 40, 50%) and different temperatures (20$\^{C}$ , 37$\^{C}$) were prepared to determine dilution at which microorganisms did not grow within 1 hour of inoculation, regardless of levels and temperatures. Heat treatment of livestock wastewater at 10 0$\^{C}$ for 2 minutes was good enough to inhibit the growth of microorganisms at 20$\^{C}$ and 37$\^{C}$. A good linear relationship was obtained between levels of livestock wastewater and absorbance at 630 nm (R=98.88%) and dry cell weight (98.98%). The dry cell weight of microorganisms in livestock wastewater was 0.375 g/L.

  • PDF

Surface Characterization of Photocatalyst TiO$_2$ (증발법을 이용한 축산분뇨의 고농도 폐수처리 기술의 개발)

  • 이영신
    • Proceedings of the KAIS Fall Conference
    • /
    • 2000.10a
    • /
    • pp.69-73
    • /
    • 2000
  • 본 연구에서는 오염부하량 측면에서 매우 심각한 영향을 미치고 있는 축산폐수에 대하여 기존의 문제점 등을 분석하고 기존의 처리 방법들이 처리를 제대로 하고 있지 못하는 원인을 분석하며, 이러한 기존의 방법 이외의 대안으로서 증발법을 이용하여 축산 폐수를 처리하고자 하였으며, 이를 폐수처리라는 차원보다는 폐기물의 재활용이라는 측면에서 퇴비화를 함으로서 오염도를 줄임과 동시에 재활용율을 고양시키고자 하였다.

축산폐수에서 분리된 질소 산화균에 의한 축산 폐수의 질산화

  • 권윤미;박재림
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2003.11b
    • /
    • pp.245-247
    • /
    • 2003
  • 축산폐수에서 분리된 세균 S. sp1(S. capitis)와 S. sp2(3. xylosus)를 이용한 축산폐수 중 질소화합물 분해정도를 파악한 결과 1) 증식에 알맞은 조건은 LB broth, $27^{\circ}C$, pH7로 나타났다. 2) S. sp1은 배양 7일 초기 농도의 90.3%, 7일째 32.9%로 감소되어 14일까지 다소 증가하면서 유지되었다. 3) S. sp1과 S. sp2를 혼합배양한 결과 S. sp1과 S. sp2 단독배양보다 분해 효율이 높고 기간도 2일정도 단축되었다.

  • PDF

Applicability of electrochemical treatment using BDD electrode (BDD 전극을 이용한 전기 화학적 처리의 적용 가능성)

  • Yu, Mi-Yeong;Kim, Seo-Han;Song, Pung-Geun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.51-51
    • /
    • 2018
  • 산업의 발달 및 인구 증가에 따라 발생되는 폐수의 종류는 다양해지고 있으며, 폐수의 처리를 위해서는 주로 생물학적 처리를 먼저 검토하게 된다. 하지만 최근 폐수의 성분은 생물학적으로 처리하기 어려운 난분해성 요인(고농도의 염분, 독성 유기용매, 중금속 등)이 존재 할 뿐 아니라, 생물학적 처리 후 존재하는 잔류 유기물은 환경부에서 제시하는 방류수 기준을 만족시키기에 어려움이 있다. 이러한 난분해성 요인을 제거하기 위해서 전기 화학적 처리의 필요성이 대두되고 있으며, 다양한 고도산화기술들이 제시되고 있다. 그 중 처리시간의 단축으로 인한 처리비용 절감과 산화제 발생에 따른 높은 처리 효율로 인해 전기화학적 폐수산화처리에 대한 연구가 활발히 진행되고 있는 실정이다. 본 연구에서는 기존에 사용되어 지고 있는 전기화학적 폐수산화처리를 위한 불용성 전극을 BDD 전극으로 대체하여 다양한 폐수에 전기분해 처리 적용 가능성을 검토하고자 기존 BDD 전극의 기판 모재로 이용되던 Si, Nb 대신에 Ti 기판 위에 BDD 형성시켜 전극을 제작하였고, 폐수의 전기분해 적용 가능성을 확인하기 위하여 축산폐수, 해양폐수, 질산염폐수 등 실제 폐수를 채수하여 폐수 내 유기물의 전기분해 처리 효율을 분석하였다. 이에 Ti 모재 기판에 증착된 BDD 전극을 이용하여 폐수 내 유기물의 전기분해 처리효율을 분석 한 결과, 축산폐수의 경우 처리시간 150분에 95% 이상 처리효율을 나타냈으며, 해양폐수의 경우 처리시간 60분에 98% 이상의 유기물 제거 효결과가 나타남에 따라 축산폐수와 선박 평형수, 양식장폐수 등 다양한 폐수에 적용이 가능할 것으로 판단되며, 기존에 적용되어 지고 있는 고도산화처리 기술을 BDD 전극을 이용한 전기화학적 처리로 대체 할 수 있을 것으로 기대할 수 있다.

  • PDF

Development of Effective Treatment Technology of Livestock wastewater (축산폐수의 효율적 처리기술 개발)

  • 조웅현;원찬희;송경선
    • Proceedings of the Korean Society of Coastal and Ocean Engineers Conference
    • /
    • 2000.09a
    • /
    • pp.77-83
    • /
    • 2000
  • 가축 사육시설에서 배출되는 축산폐수는 도시하수와 달리 발생량에 비해 오염부하량이 대단히 크므로 수질오염의 주범일 뿐만 아니라 처리에도 어려움이 많아 축산폐수를 수거하여 전문적으로 처리하는 공동처리장에서도 현재 만족 할만한 처리효과를 기대하기 힘든 처지에 있다. (중략)

  • PDF

Growth Response and Absorption Capacity of Poplars on Livestock Waste Water (축산폐수(畜産廢水) 처리(處理)에 따른 포플러류(類)의 생육반응(生育反應) 및 축산폐수(畜産廢水) 흡수능력(吸收能力))

  • Yeo, Jin Kie;Koo, Yeong Bon;Son, Doo Sik
    • Journal of Korean Society of Forest Science
    • /
    • v.90 no.6
    • /
    • pp.734-741
    • /
    • 2001
  • The two-month-old rooted-cuttings of Populus alba ${\times}$ glandulosa, P. euramericana and P. nigra ${\times}$ maximowiczii clones were exposed to livestock waste water - one of major water pollutants, and ground water in order to determine the effects of livestock waste water on growth response and absorption capacity of the species. For this purpose, 5 clones of each species were used. In all the species, the height growth of rooted-cuttings was better in livestock waste water treatment than in ground water. Of all the poplar species compared, the height growth was best in P. alba ${\times}$ glandulosa. In the cases of P. euramericana and P. nigra ${\times}$ maximowiczii, the height growth in the livestock waste water treatment was statistically different among clones, whereas there was no significant difference among P. alba ${\times}$ glandulosa clones. Aboveground biomass such as leaf and shoot dry weight of all the species increased in the livestock waste water treatment, while root dry weight decreased. In addition, chlorophyll contents in leaf of all the poplar species increased in the livestock waste water treatment. All the poplar trees showed temporal variation in the absorption amount of livestock waste water during the experimental period. In all the poplar species, the absorption amount of livestock waste water was less than that of ground water. Of 3 poplar species, P. alba ${\times}$ glandulosa was best in the absorption capacity of livestock waste water. Of all 15 poplar clones compared in this study, the 72-16 clone of P. alba ${\times}$ glandulosa showed the best absorption capacity.

  • PDF

A study on The Effect of Antibiotics Usage too The Efficiency of Biological Piggery Wastewater Treatment (축산물에 사용되는 항생제가 축산폐수의 처리효율에 미치는 영향)

  • Cho, Mi Kyeong;Tran, Hung Thuan;Kim, Dae Hee;Jia, Yu Hong;Oh, Se Jin;Ann, Dae Hee
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.15 no.1
    • /
    • pp.123-133
    • /
    • 2007
  • The presence of antibiotics in the wastewater from livestock farm due to its over-application should be concerned because they could change microbial ecology, increase the proliferation of antibiotic resistant pathogens, provoke toxic effect on aquatic species. In addition, these antibiotics can cause negative effect on the performance of biological wastewater treatment due to its antibacterial properties. In this study, our aim is to evaluate the effect of some common used antibiotic in Korea piggery farm such as oxytetracycline (OTC) to nitrification efficiency as well as organic compounds removal rate in biological system for treating piggery wastwater. The experiment was conducted in aeration batch reactor and lab-scale $A_2/O$(Anoxic-Anoxic-Oxic) system. From this study, it would be suggested that the piggery wastewater characterization should be examined in order to assess the fraction of common used antibiotics. The alternative treatment processes for piggery wastewater having high-strength antibiotics might be suggested in the future work.

  • PDF

방사선조사에 의한 축산폐수의 질산화 효율 향상

  • Kim, Tak-Hyeon;Kim, Tae-Hun;Lee, Jae-Gwang;Yu, Seung-Ho;Lee, Myeon-Ju
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2006.05a
    • /
    • pp.358-360
    • /
    • 2006
  • 축산폐수내의 질소 성분의 효율적인 처리를 위하여 생물학적 질산화반응과 방사선조사기술을 결합시키는 연구를 수행하였다. 축산폐수에 방사선을 조사하여 줌으로써 생성되는 라디칼들에 의하여 폐수내 난분해성 유기물들의 생분해도가 향상되어 짧은 HRT에도 불구하고 완전한 NH$_4^+$-N의 산화가 이루어졌다.

  • PDF

A Study on Inorganic Chemical Treatment Method of Animal Wastes Using by Electroflotation for Recycle (전해부상 장치를 이용한 축산폐수의 유기질비료와 용수 재활용에 관한 연구)

  • Sung Ki-chun;Kim Yong-Ryul;Kim Ki-Jun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.5 no.6
    • /
    • pp.588-591
    • /
    • 2004
  • There is an increasing interest in the use of electrochemical methods for the animal waste treatment The technologies using the electrochemical method provide ideal tools for approaching industrial and animal wastes problems. Unlike other chemical treatments, the electrochemical systems do not make the volume of the secondary waste increase. The electrochemical methods can be operated with electrochemical apparatus and inorganic agent allow selective separation and recovery and even quieter than others. This study concerns design factors, electrode construction and wastewater treatment process of the electrochemical apparatus. The experiment of color, COD and BOD removal is much effective in using electrochemical method with ultrasonication and ozonation.

  • PDF