• Title/Summary/Keyword: 축교정

Search Result 98, Processing Time 0.028 seconds

$\Delta$-plan and spin in the golf swing (골프 스윙에서 $\Delta$-평면과 스핀)

  • Jo, Chang-Ho;Park, Jong-Dae;Lee, Kun-Chun
    • The Journal of Natural Sciences
    • /
    • v.14 no.2
    • /
    • pp.1-14
    • /
    • 2004
  • The observation of the various swing parameters and its effect on golfer swing are tatally analyzed. The golf ball impact and flies away, therefore it must be controlled bofore ball impact. The purpose of this paper is that the cause of hook and slice are found and the posture of swing is corrected. The trajectory after ball impact is on the $\Delta$-plane, which is consisted of the normal vector on club face and the swing velocity vector of club head including the initial celocity and the spin axis after ball imfact. In order to correct the miss shot in golf swing, this paper is is shown that the theoretical review and study is discussed to use the D-plane and $\Delta$-plane.

  • PDF

Changes of lateral cephalometric values according to the rotation of head (두부회전에 따른 측모두부방사선 계측치의 변화)

  • Kim, Kwang-Soo;Hwang, Mee-Sun;Choi, Eui-Hwan;Kim, Kwang-Won;Yoon, Young-Jooh
    • The korean journal of orthodontics
    • /
    • v.30 no.1 s.78
    • /
    • pp.53-66
    • /
    • 2000
  • This study was performed to find out the effect of projection errors on cephalometric linear and angular measurements according to head rotation during taking lateral cephalometric radiographs. Seventeen skulls with permanent dentition and no gross asymmetry were obtained from the Department of Anatomy, Medical School, Chosun University. Total 527 x-ray films were taken with $1^{\circ}$ interval from the reference position($0^{\circ}$) to ${\pm}15^{\circ}$ around the vertical axis (Z axis) which is perpendicular to the midpoint of the line connecting the center of two ear rods in submento-vertex direction. Statistical analysis was performed by paired t-test if there were statistically significant differences between the mean of the reference position($0^{\circ}$) and that of each rotation angle. The following results were obtained. 1. The projection errors of angular measurements were smaller than those of linear measurements. 2. The projection errors of angular measurements including midline landmarks were smaller than those including bilateral landmarks. 3. The horizontal linear measurements were gradually decreased when the stroll was rotated toward the film, but slightly increased and then decreased when the skull was rotated toward the focal spot. However, the changes were smaller in focal direction. 4. The projection errors of horizontal linear measurements were larger than those of vertical linear measurements. 5. The projection errors of vertical linear measurements were increased with increased distance from the rotation axis to vertical measurements. It is concluded that the use of angular measurements rather than linear measurements is recommended to minimize the projection errors.

  • PDF

Distortion of tooth axes on panoramic radiographs taken at various head positions (두부 위치 변화에 따른 파노라마 방사선사진상의 치축각도의 왜곡)

  • Jeon, Hyun-Sang;Choi, Gab-Lim;Lim, Sung-Hoon;Kim, Kwang-Won
    • The korean journal of orthodontics
    • /
    • v.38 no.4
    • /
    • pp.240-251
    • /
    • 2008
  • Objective: The purpose of this study was to evaluate the effect of head position changes on the root parallelism between adjacent teeth on panoramic radiographs. Methods: A model with normal occlusion was constructed in the SolidWorks program, then RP (rapid protyping) model was fabricated. The model was repeatedly imaged and repositioned five times at each of the following nine positions: ideal head position, $5^{\circ}$ up, $10^{\circ}$ up, $5^{\circ}$ down, $10^{\circ}$ down, $5^{\circ}$, right, $10^{\circ}$, up, and $5^{\circ}$ right rotation, $10^{\circ}$ right rotation. Panoramic radiographs were taken by Planmeca ProMax and the angle between the long axes of adjacent teeth was directly measured in the monitor. Results: Axes of adjacent teeth tended to converge toward the occlusal plane when the head tilted up and converged in the opposite direction to the occlusal plane when the head tilted down. Anterior teeth showed the most notable differences. When one side of the head tilted up $5^{\circ}$ and $10^{\circ}$ along the anteroposterior axis (Y axis), tooth axes of the same side tended to converge toward the occlusal plane and tooth axes of the opposite side tended to converge in the opposite direction to the occlusal plane. When the head rotated to one side along the vertical axis (Z axis), the canine and lateral incisor of the same side converged in the opposite direction to the occlusal plane and the canine and lateral incisor of the other side converged toward the occlusal plane. Conclusions: When assessing the root parallelism on panoramic radiographs, the occlusal plane cant (anteroposterior or lateral) or asymmetry of the dental arch should be considered because these can cause distortion of tooth axes on panoramic radiographs.

Mid to Long Term Outcomes of Surgical Treatment for Isolated Coarctation of Aorta (단순 대동맥 축착의 외과적 치료 후 중.장기 결과)

  • Lee, Seung-Cheol;Yoon, Tae-Jin;Park, Jeong-Jun;Song, Meong-Gun;Kim, Young-Hwee;Ko, Jae-Kon;Park, In-Sook;Seo, Dong-Man
    • Journal of Chest Surgery
    • /
    • v.40 no.2 s.271
    • /
    • pp.83-89
    • /
    • 2007
  • Background: The surgical repair of an isolated coarctation of the aorta, without complex cardiac anomalies, has improved, with very good results. However, despite the success of surgical repair, many long-term complications, such as hypertension, re-coarctation and an aortic aneurysm, still exist. Material and Method: Between 1991 and 2006, 50 patients diagnosed with an isolated coarctation of the aorta were reviewed retrospectively. The incidence of re-coarctation and hypertension were compared with respect to age and surgical methods. Result: There were no early & late mortality, or post operative aortic aneurysms. Hypertension developed in 11 patients (22%). A greater number of patients in the child/adult group had hypertension (52.4%) than in the neonate/infant group (0%). With respect to the surgical methods, the patients in the graft interposition group suffered more hypertension (88.9%) than those in the EEEA (extended end to end anastomosis) group (5.3%). Post operative re-coarctation developed in 2 out of the 29 patients (6.9%) in the neonate/infant group and 2 out of the 21 patients (9.5%) in the child/adult group, but without any statistical difference. There were no statistical differences between the operative type-related groups. Conclusion: Even though the surgical outcomes have greatly improved, an isolated coarctation of the aorta still has many long-term problems, such as hypertension and re-coarctation. An isolated coarctation is accepted as a systemic vascular dysfunction, and often progresses to other cardiovascular diseases. Therefore, patients with a coarctation of the aorta have to be carefully followed-up, and aggressive management must be given when required.

Development of the Balance Chair for Improving Postural Control Ability & Pelvic Correction (골반교정 및 자세균형능력 증진을 위한 균형의자 개발)

  • Oh, Seung-Yong;Shin, Sun-Hye;Kang, Seung-Rok;Hong, Chul-Un;Kwon, Tae-Kyu
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.11 no.3
    • /
    • pp.271-277
    • /
    • 2017
  • The purpose of this study was to develop a balance chair for improving pelvic correction and postural balance through postural balance training using tactile feedback by a vibration motor provided in real time according to the user's attitude. We built a body frame using mono cast(MC) Nylon, Touch thin film transistor(TFT) for user interface, a main control module using Arduino, a 9-axis acceleration sensor for user's posture determination, and a vibration module for tactile feedback. The prototype of the Balance Chair which surrounds the outside was made with cushion for sitting conformability. In order to verify the effectiveness of the postural balance training system using the built prototype, the muscle activity (% MVIC) of the left and right iliocostalis lumborum those are the main muscles of the spinal movement was measured with ten female subjects. And the balance ability before and after training was measured using Spine Balance 3D, a posture balance ability evaluation device. The muscular activities of the left and right iliocostalis lumborum showed the balance activation according to vibration feedback during exercise protocol and postural balance improved after balance exercise training using balance chair. This study could be apply to use the fundamental research for developing the various postural balance product.

RCCA End-Tip Examination by ECT (원자로 제어봉 End-Tip 원주방향균열 와전류검사)

  • Lee, H.J.;Nam, M.W.;Jung, G.J.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.18 no.6
    • /
    • pp.455-463
    • /
    • 1998
  • RCCA(rod cluster control assembly) End-Tip suffers from neutron irradiation and constant vibration due to high-speed internal flow of primary coolant during plant operation. Such operating conditions cause the RCCA end-tip crackings around tile circumferential weldment of the end-tip, and in some cases, the defective end-tips were completly broken loose. However, no reliable inspection techniques for end-tip crackings were developed in the past, although some techniques exist for inspecting RCCA control rod wears. Therefore, NDE group at KEPRI has developed an ECT technique for the detection and the sizing of the end-tip crackings. The technique uses a specially designed surface-riding probe that can detect size of circumferential crackings with an accuracy of ${\pm}5.31%$ RMS error. This paper describes the ECT instrumentation including the ECT probes, calibration bars, as well as technical approaches.

  • PDF

Expectation of Astigmatism by Spherical Equivalent Visual Acuity (등가구면 시력으로부터 난시량의 예측)

  • Kim, Sang-Yoeb;Moon, Byeong-Yeon;Cho, Hyun Gug
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.2
    • /
    • pp.167-170
    • /
    • 2011
  • Purpose: This study was tried whether expectation of astigmatism from spherical equivalent visual acuity was possible. Methods: For 54 men and women (108 eyes) corrected to emmetropia, average age of 23.3, changes of visual acuity (5m) were measured with an increasing the powers at every ${\pm}$0.25D when the (-) axis of cross cylinder is $180^{\circ}$, $90^{\circ}$, and $45^{\circ}$, respectively. Results: As the power of cross cylinder was increased, visual acuity was decreased. When the powers of cross cylinder were ${\pm}$2.50D ($180^{\circ}$ and $90^{\circ}$) and ${\pm}$2.25D ($45^{\circ}$), visual acuity was 0.05 which is the minimum measurement possible. Conclusions: The diagram on astigmatism dealing with each spherical equivalent visual acuity was able to tabulate.

THE BEAM POINTING OF COMMUNICATIN SATELLITE IN GEOSYNCHRONOUS INCLINED ORBIT (궤도경사각을 가진 통신위성의 빔 포인팅에 대한 연구)

  • 김방엽;최규홍
    • Journal of Astronomy and Space Sciences
    • /
    • v.12 no.1
    • /
    • pp.112-122
    • /
    • 1995
  • We assume that the KOREASAT fails the entry of the geostationary orbit due to the error at the apogee kick motor firing. A simulation is done for the satellite that has a geosynochronous orbit with a non-zero degree inclination angle due to the failure at the apogee kick motor firing caused by the unbalance of the fuel storage and the spin of the thrust vector, etc. We analyzed the evolution of the orbit using the perturbation theory and calculated the changes of the eccentricity and the inclination. WHen a communication satellite has the figure eight trajectory, the beam point also traces the satellite. In this paper, We develope an algorithm to attack the above problem by stabilizing the beam point using the adjustment of the roll angle of the satellite. The spin action on the polarization plane that occurs when a satellite passes the ascending node and descending node affects the efficiency of the communication a lot, so we did another simulation for the better yaw angle adjustment for the KOREASAT to reduce the spin actino on the polarization plane.

  • PDF

Evaluation on Mechanical Properties of a Smart Composite Using the finite Element Method and the Acoustic Emission Technique (FEM과 AE를 이용한 지적복합재료의 기계적특성 평가)

  • Park, Young-Chul;Lee, Jin-Kyung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.3
    • /
    • pp.233-239
    • /
    • 2004
  • Smart material is used in various applications such as for glass frame, for medical instruments and for a part of sensors. Smart composite materials ran be applied to a part of aircraft and to the on-line monitoring system for industrial structures, using the shape memory effect. However, it is very difficult to simulate and analyze the shape memory effect in smart composites. In this paper, a two dimensional axisymmetric model was proposed to analyze the smart composite of one fiber and matrix using the finite element method(FEM). The finite element analysis was carried out in two renditions of the room temperature(293K) and a higher temperature (363K). The results we.e compared with the experimental results to confirm the validity of the analysis. In addition, the acoustic emission(AE) technique was used to study the microscopic damage behavior and the effect of pre-strains on TiNi/A16061 shape memory alloy composite.

Effect of Tibial Cut Planes and Hinge Axes on Medial Opening Wedge High Tibial Osteotomy (내측개방형 근위경골절골술의 경골절단면 및 경골개방축의 설정에 따른 영향)

  • Park, Byoung-Keon;Lee, Ho-Sang;Kim, Jay-Jung;Kim, Cheol-Woong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.8
    • /
    • pp.835-846
    • /
    • 2011
  • In medial opening wedge high tibial osteotomy (OWHTO), researchers have reported critical problems caused by unexpected changes in the tibial posterior-slope angle. This unexpected change can be analyzed, but there is no general solution for cases with an oblique hinge axis and cut plane. We propose a general analysis model for OWHTO. We first evaluate the effects according to variation in the hinge axis and tibial cut plane and then define an ideal correction axis. This ideal axis, called the virtual tibial correction axis, is not on the tibial cut plane in general. In this paper, we also present an evaluation of feasibility of the proposed analysis model.