• Title/Summary/Keyword: 최소 침습적

Search Result 176, Processing Time 0.024 seconds

Abstract Minimally Invasive Aort ic Valve Surgery -A Report of Two Cases (최소 침습성 대동맥 판막 수술 -2례 보고-)

  • 백완기;김현태
    • Journal of Chest Surgery
    • /
    • v.30 no.11
    • /
    • pp.1139-1141
    • /
    • 1997
  • Recently, minimally invasive approach via limited incision becomes one of the rapidly developing strategy in cardiac surgery as it gives less surgical trauma and is more satisfactory to the patients in respect to operative scar although the surgical technique is more demanding. Here, we report two cases of aortic valve replacement via limited transsternal incision. The methodology is described with review of the relevant literature.

  • PDF

A Study on Development of Technology System for MIS(Minimally Invasive Surgery) robot of S. Korea analysed by the Application of Scenario Planning (최소침습수술용 의료로봇 기술개발연구 - 시나리오플래닝을 적용하여 -)

  • Lee, Sang-Yun;Yoon, Hong-Joo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.1
    • /
    • pp.13-26
    • /
    • 2013
  • This study is about development of technology system for MIS(Minimally Invasive Surgery) robot of S. Korea analysed by the application of scenario planning. MIS robot industry receive attention as a new growth industry for national and international and is noticeable for the leading industry of future era in Korea. In this paper was examined the characteristics of an MIS robot technology and its components. It was investigated about the technology of an overseas MIS robot(especially U.S.A) and Korean domestic MIS robot and understood such as the country's policy propulsion issues then, was searched about development direction of the future. As a result, the future policy for MIS robot of S. Korea is to further spur the development of new MIS robot technology and more improvement of the technology level of MIS robot with AR(Augmented Reality) display.

Minimally Invasive Simultaneous Treatment for Congenital Cystic Adenomatoid Malformation associated with Pectus Excavatum - A case report - (누두흉과 선천성 낭종성 선종양 기형의 최소 침습적인 동시수술 -1예 보고-)

  • Cho, Deog-Gon;Jo, Min-Seop;Kim, Kyung-Soo;Wang, Young-Pil;Cho, Kyu-Do
    • Journal of Chest Surgery
    • /
    • v.39 no.2 s.259
    • /
    • pp.171-175
    • /
    • 2006
  • Minimally invasive thoracic surgery has been one of the most important surgical advances recently. Congenital cystic adenomatoid malformation of the lung is a relatively rare anomaly and is clearly associated with various congenital anomalies such as pectus excavatum, cardiac and pulmonary vascular lesions. We have experienced a case that was treated with minimal invasive methods for congenital cystic adenomatoid malformation involving in the right lower lobe and pectus excavatum in a 5-year-old boy. We simultaneously performed thoracoscopic right lower lobectomy and Nuss procedure of pectus excavatum using a substernal steel bar. Therefore, a minimally invasive surgical treatment for this diseases is feasible and cosmetically excellent.

노인성질환 치료를 위한 최소 침습 수술 기술

  • 최귀원
    • Journal of the KSME
    • /
    • v.44 no.1
    • /
    • pp.55-60
    • /
    • 2004
  • 이 글에서는 노인의 대표적인 질환인 심혈관계 질환, 관절계 질환, 비뇨기계 질환의 치료를 위한 외과적인 수술 기술로 현재 의료기관에서 널리 사용되고 있는 최소 침습수습 기술을 소개한다.

  • PDF

Use of Minimally Invasive Plate Osteosynthesis for Tibial Diaphyseal Fracture in Three Dogs (경골 골간 골절에서의 최소 침습적 금속판 고정술의 이용 3례)

  • Heo, Su-Young;Lee, Ki-Chang;Lee, Hae-Beom
    • Journal of Veterinary Clinics
    • /
    • v.29 no.4
    • /
    • pp.339-343
    • /
    • 2012
  • Three dogs were presented with diaphyseal fracture of the tibia following separate motor vehicle accidents. On physical and orthopedic examinations, the dogs were noted to have soft-tissue swelling and a closed fracture in these tibia sites. Radiographs revealed a simple, short oblique fracture (case 1), a comminuted, spiral fracture (case 2), and a simple, spiral fracture (case 3) in tibia. Minimally invasive percutaneous plate osteosynthesis (MIPO) using a veterinary cuttable plate or locking plate was applied for the treatment of these fractures. The surgery was successful, and the fractures healed without any complications by 7 weeks (case 1), 10 weeks (case 2) and 8 weeks (case 3) after surgery. Our patients showed fast bone healing times and early weight-bearing during the treatment of their tibia fractures. Therefore, MIPO was a useful procedure for diaphyseal fracture of the tibia in veterinary orthopedics.

The Treatment of Humerus Shaft Simple Fracture by MIPO Technique (상완골 간부 단순 골절에서 최소 침습적 금속판 골유합술을 이용한 치료)

  • Ko, Sang-Hun;Lee, Sun-Ho;Cho, Bum-Keun
    • Clinics in Shoulder and Elbow
    • /
    • v.16 no.1
    • /
    • pp.27-32
    • /
    • 2013
  • Purpose: The purpose of this study is to evaluate the clinical and radiological outcomes of treatment of humerus shaft simple fracture by minimally invasive percutaneous osteosynthesis (MIPO) technique using locking compression plate (LCP). Materials and Methods: Six patients who were operated for humerus shaft simple fracture from August 2010 to May 2011 were enrolled for this study. We checked the cause of injury and the accompanying injuries and evaluated the operation time, the clinical and radiological period of union, postoperative range of motion of the shoulder and elbow joint, pain, activities in daily living, radiologic alignment, and other complications. Results: The clinical period of bone union was 7.2 weeks on average, and the radiologic period of bone union was 8 weeks on average. Follow-up period was more than 12 months in all cases. The angulation through postoperative alignment was 2.8 degrees in AP view and 2 degrees in lateral view. The postoperative range of motion was 167 degrees in forward flexion, 50 degrees in external rotation, and thoracic vertebra 12 level in internal rotation. The average value of visual analogue scale (VAS) was 1.2 and that of KSS was 91.3. The American Shoulder and Elbow Surgeons' score (ASES) was 26.5 and the UCLA score was 31.5. Conclusion: MIPO technique for the humerus shaft simple fracture showed good functional and radiological outcomes and may be considered as one of the treatment options for humerus shaft simple fracture.

Double Valve Replacement via Ministernotomy -A Case Report- (소흉골절개술을 통한 이중판막치환술 -1례 보고-)

  • 백완기;김현태;심상석;조상록;박현희
    • Journal of Chest Surgery
    • /
    • v.31 no.1
    • /
    • pp.52-54
    • /
    • 1998
  • Recently, several versatile approaches via limited incision have been developed for minimally invasive cardiac surgery. As the incision is limited, it is often dfficult to get a satisfactory operative field, especially for the manipulation of two separate lesions such as simultaneous mitral and aortic valve disease with a single limited incision. Here, we describe a case of successful double valve replacement via ministernotomy, which was followed by two cases of minimally invasive aortic valve replacement via transsternal approach. The operative field was unexceptionally satisfactory and the postoperative patient's acceptance was high. The methodology is described with a review of the relevant literatures.

  • PDF

Minimally Invasive Arthroscopic-Assisted Reduction with TightRope® for Coxofemoral Luxation in a Korean Water Deer (Hydropotes inermis argyopus) (고라니에서 최소침습적 관절경과 TightRope®의 이용한 엉덩관절탈구 교정 증례)

  • Heo, Su-Young;Seol, Jae-won;Park, Ji-young;Jeong, Seong-mok;Lee, Hae-Beom
    • Journal of Veterinary Clinics
    • /
    • v.32 no.6
    • /
    • pp.540-543
    • /
    • 2015
  • A Korean water deer was rescued with non-weight-bearing lameness of the right hind limb. Clinical and radiographic examination revealed a craniodorsal coxofemoral luxation. The cause of the right coxofemoral luxation (CL) was unknown. We performed minimally invasive arthroscopic-assisted reduction with toggle pin fixation (mini TightRope$^{(R)}$). Craniodorsal CL in the water deer was reduced and stabilized successfully. At 60 days after admission, the water deer was successfully released back into the wild. This minimally invasive surgical technique can be used to correct coxofemoral luxation in wild animals.