• Title/Summary/Keyword: 최소침습성 직접 관상동맥우회술

Search Result 2, Processing Time 0.021 seconds

Axillocoronary Bypass as Coronary Reoperation via Minimally Invasive Procedure-A Report of One Case- (관상동맥 재수술로서의 최소 침습 수기를 통한 액와 -관상동맥 우회술 -1례 보고-)

  • 백완기;윤용한;김정택;김광호;임현경
    • Journal of Chest Surgery
    • /
    • v.34 no.5
    • /
    • pp.399-402
    • /
    • 2001
  • 최근 심폐기를 사용하지 않는 최소침습성 직접 관상동맥우회술(MIDCAB procedure)은 심장수술 분야에서 급속도로 발전을 거듭하고 있다. 금번 저자들은 전에 만들어 준 좌전하행지 이식편이 막혀 관상동맥 재수술을 필요로 하였으나 좌내 유동맥의 혈류량의 불충분하였다고 생각되었다. 1례에서 최소 침습 수기를 통한 액와-관상동맥 우회술을 시행하여 만족스러운 결과를 얻었기에 문헌고찰과 함께 보고하고자 한다.

  • PDF

The First 20 Cases of Cardiac Surgery Using the da $Vinci^{TM}$ Surgical System: A Single Center Experience (다빈치 수술로봇을 이용한 심장수술 20예 보고 - 단일 기관 보고 -)

  • Je, Hyoung-Gon;Lee, Yong-Jik;Jung, Sung-Ho;Jung, Jae-Seung;Kang, Pil-Je;Choo, Suk-Jung;Song, Hyun;Chung, Cheol-Hyun;Lee, Jae-Won
    • Journal of Chest Surgery
    • /
    • v.41 no.4
    • /
    • pp.423-429
    • /
    • 2008
  • Background: The interest in robotic cardiac surgery has recently grown but there has not been much clinical research reported on this. The aim of this study is to examine our initial experience, since August 2007, with robotic cardiac surgery using the da $Vince^{TM}$ surgical system and to evaluate the feasibility and safety of it. Material and Method: Between August and December 2007, a total of 20 patients underwent robotic cardiac surgery using the da Vinci surgical system. For mitral valve repair (n=11), tricuspid valve repair (n=1), and ASD repair (n=1), cannulation, antegrade cardioplegia and transthoracic aortic cross-clamping were conducted for the right femoral vessels and the right internal jugular vein. For minimally invasive direct CABG (MIDCAB) (n=7), the internal thoracic artery (ITA) was harvested with the da Vinci surgical system. Result: The mean age of the patients was 50.1 (range: $26{\sim}78$) years. Three concomitant Maze procedures and one tricuspid annuloplasty were combined with mitral valve repair. The mean cardiopulmonary bypass time was $208.0{\pm}61.3$ minutes and the aortic cross clamp time was $158.8{\pm}40.6$ minutes. No patients showed more than mild mitral regurgitation after repair and the median hospital stay was 4 days. The robotic-harvested ITA was used for either left ITA (n=6) or bilateral ITA (n=1). The mean harvest time was $43.2{\pm}12.0$ minutes. The harvested ITA showed good flow and it was anastomosed under direct vision after left anterolateral thoracotomy. The patency of all the grafts was 100% (18/18) in MIDCAB. Conclusion: Robotic cardiac surgery using the da Vinci surgical system was variously adapted to areas such as mitral and tricuspid valve repair, ASD repair and ITA harvest for MIDCAB. The early results of the robotic cardiac surgery showed its safety and feasibility. With this primary report, we anticipate that clinical applications and further studies on robotic cardiac surgery using the da Vinci surgical system will be actively conducted in Korea.