• Title/Summary/Keyword: 최소차이추정량

Search Result 4, Processing Time 0.097 seconds

Robust Discriminant Analysis using Minimum Disparity Estimators

  • 조미정;홍종선;정동빈
    • Proceedings of the Korean Statistical Society Conference
    • /
    • 2004.11a
    • /
    • pp.135-140
    • /
    • 2004
  • Lindsay and Basu (1994)에 의해 소개된 최소차이추정량 (Minimum Disparity Estimators)들은 실제 자료 분석 도구로써 유용하다. 본 논문에서는 최소일반화음지수 차이추정량 (Minimum Generalized Negative Exponential Disparity Estimator, MGNEDE)이 최대가능도추정량 (Maximum Likelihood Estimator, MLE)와 최소가중 헬링거거리추정량 (Minimum Blended Weight Hellinger Distance Estimator, MBWHDE)에 비해 오염된 정규모형에서 효율적이고 로버스트하다는 것을 모의실험을 통하여 확인하였다. 또한 세 가지 추정량들에 의해 추정된 모수들을 이용하여 판별하였을 때 자 추정량득의 판별율을 비교함으로써 오염된 정규모형에서 MLE의 대안으로 MGNEDE와 MBWHDE를 사용할 수 있음을 보였다.

  • PDF

A Modi ed Entropy-Based Goodness-of-Fit Tes for Inverse Gaussian Distribution (역가우스분포에 대한 변형된 엔트로피 기반 적합도 검정)

  • Choi, Byung-Jin
    • The Korean Journal of Applied Statistics
    • /
    • v.24 no.2
    • /
    • pp.383-391
    • /
    • 2011
  • This paper presents a modified entropy-based test of fit for the inverse Gaussian distribution. The test is based on the entropy difference of the unknown data-generating distribution and the inverse Gaussian distribution. The entropy difference estimator used as the test statistic is obtained by employing Vasicek's sample entropy as an entropy estimator for the data-generating distribution and the uniformly minimum variance unbiased estimator as an entropy estimator for the inverse Gaussian distribution. The critical values of the test statistic empirically determined are provided in a tabular form. Monte Carlo simulations are performed to compare the proposed test with the previous entropy-based test in terms of power.

Identification of Uncertainty in Fitting Rating Curve with Bayesian Regression (베이지안 회귀분석을 이용한 수위-유량 관계곡선의 불확실성 분석)

  • Kim, Sang-Ug;Lee, Kil-Seong
    • Journal of Korea Water Resources Association
    • /
    • v.41 no.9
    • /
    • pp.943-958
    • /
    • 2008
  • This study employs Bayesian regression analysis for fitting discharge rating curves. The parameter estimates using the Bayesian regression analysis were compared to ordinary least square method using the t-distribution. In these comparisons, the mean values from the t-distribution and the Bayesian regression are not significantly different. However, the difference between upper and lower limits are remarkably reduced with the Bayesian regression. Therefore, from the point of view of uncertainty analysis, the Bayesian regression is more attractive than the conventional method based on a t-distribution because the data size at the site of interest is typically insufficient to estimate the parameters in rating curve. The merits and demerits of the two types of estimation methods are analyzed through the statistical simulation considering heteroscedasticity. The validation of the Bayesian regression is also performed using real stage-discharge data which were observed at 5 gauges on the Anyangcheon basin. Because the true parameters at 5 gauges are unknown, the quantitative accuracy of the Bayesian regression can not be assessed. However, it can be suggested that the uncertainty in rating curves at 5 gauges be reduced by Bayesian regression.

Dose Planning of Forward Intensity Modulated Radiation Therapy for Nasopharyngeal Cancer using Compensating Filters (보상여과판을 이용한 비인강암의 전방위 강도변조 방사선치료계획)

  • Chu Sung Sil;Lee Sang-wook;Suh Chang Ok;Kim Gwi Eon
    • Radiation Oncology Journal
    • /
    • v.19 no.1
    • /
    • pp.53-65
    • /
    • 2001
  • Purpose : To improve the local control of patients with nasopharyngeal cancer, we have implemented 3-D conformal radiotherapy and forward intensity modulated radiation therapy (IMRT) to used of compensating filters. Three dimension conformal radiotherapy with intensity modulation is a new modality for cancer treatments. We designed 3-D treatment planning with 3-D RTP (radiation treatment planning system) and evaluation dose distribution with tumor control probability (TCP) and normal tissue complication probability (NTCP). Material and Methods : We have developed a treatment plan consisting four intensity modulated photon fields that are delivered through the compensating tilters and block transmission for critical organs. We get a full size CT imaging including head and neck as 3 mm slices, and delineating PTV (planning target volume) and surrounding critical organs, and reconstructed 3D imaging on the computer windows. In the planning stage, the planner specifies the number of beams and their directions including non-coplanar, and the prescribed doses for the target volume and the permissible dose of normal organs and the overlap regions. We designed compensating filter according to tissue deficit and PTV volume shape also dose weighting for each field to obtain adequate dose distribution, and shielding blocks weighting for transmission. Therapeutic gains were evaluated by numerical equation of tumor control probability and normal tissue complication probability. The TCP and NTCP by DVH (dose volume histogram) were compared with the 3-D conformal radiotherapy and forward intensity modulated conformal radiotherapy by compensator and blocks weighting. Optimization for the weight distribution was peformed iteration with initial guess weight or the even weight distribution. The TCP and NTCP by DVH were compared with the 3-D conformal radiotherapy and intensitiy modulated conformal radiotherapy by compensator and blocks weighting. Results : Using a four field IMRT plan, we have customized dose distribution to conform and deliver sufficient dose to the PTV. In addition, in the overlap regions between the PTV and the normal organs (spinal cord, salivary grand, pituitary, optic nerves), the dose is kept within the tolerance of the respective organs. We evaluated to obtain sufficient TCP value and acceptable NTCP using compensating filters. Quality assurance checks show acceptable agreement between the planned and the implemented MLC(multi-leaf collimator). Conclusion : IMRT provides a powerful and efficient solution for complex planning problems where the surrounding normal tissues place severe constraints on the prescription dose. The intensity modulated fields can be efficaciously and accurately delivered using compensating filters.

  • PDF