• Title/Summary/Keyword: 최대 허용오차

Search Result 68, Processing Time 0.034 seconds

A Comprehensive Analysis of 3D Body Scanning vs. Manual Measurements in a Large-Scale Anthropometric Survey -Insights from the 8th Size Korea Project- (대규모 인체치수조사 사업에서 3차원 측정치와 직접측정치의 차이 분석 -제8차 사이즈코리아 사업을 중심으로-)

  • Sunmi Park
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.48 no.2
    • /
    • pp.233-253
    • /
    • 2024
  • This study analyzed differences between three-dimensional (3D) body scanning and manual measurements, aiming to assess whether 3D scanning can replace traditional anthropometric tools, such as tape measures and calipers. Data from 4,478 participants in the 8th Size Korea Project were analyzed, covering 43 measurement items. Since Given that the 3D and manual measurements were performed on the same subjects in the 8th Size Korea Project, it was possible to determine the correlation more accurately between the two measurement methods more accurately. Using Applying ISO 20685-1(2018) standards, 15 out of the 43 items fell within allowable error limits. When classified into six types, "small circumferences" and "segment lengths" showed averages of 3.35 mm and 3.10 mm, respectively, within acceptable range. "Body heights" and "body depths" slightly exceeded the limit, with averages of 5.28 mm and 6.58 mm. "Body widths" and "large circumferences" surpassed the limit, with means of 16.77 mm and 16.18 mm. The study offers an objective basis to for validate validating 3D measurements' measurements' reliability and accuracy, addressing various industries' needs for information on the human body's dimensions information.

고해상도 관측위성의 지상궤적 유지조정 알고리즘 연구

  • Park, Jae-Ik;Park, Sang-Yeong;Lee, Byeong-Seon;Hwang, Yu-Ra;Choe, Gyu-Hong
    • Bulletin of the Korean Space Science Society
    • /
    • 2009.10a
    • /
    • pp.39.4-40
    • /
    • 2009
  • 이 연구의 목적은 고해상도 합성개구레이더 센서를 탑재한 관측위성의 운용요구사항에 맞춰 임무기간 동안 관측 목표지역을 주기적으로 반복하고 지상궤적을 $\pm2km$ 범위 내에서 안정성을 갖도록 유지 조정하는 궤도제어 알고리즘 연구를 수행하는데 있다. 기존에 수행되어 왔던 지상궤적에 대한 오차를 해석적으로 계산하여 궤도를 유지 조정하는 방법이 아닌 기준궤도에 대하여 상대좌표계에서 표현된 위성의 실제 접촉궤도를 기준궤도와 직접적으로 비교하여 목표궤적을 유지 조정하는 알고리즘을 연구하였다. 이를 위해 첫째, 고해상도 관측위성의 운용요구사항을 만족하는 계획된 목표궤도인 기준궤도를 설계하였다. 기본적으로 기준궤도는 임무 설계 시 완전한 주기성이 고려된 최대한 실제에 가까운 궤도이기 때문에 지구중력장 모델만을 고려하여 간략하게 설계하였다. 둘째, 실제의 인공위성의 궤도는 계획된 기준궤도를 유지해야 하지만 시간에 따라 섭동력의 영향을 받아 계획된 궤도로부터 벗어나게 된다. 기준궤도로부터 실제궤도가 얼마나 벗어나는지에 대한 정량적 분석을 위해 지구 중력장, 달-태양 중력, 대기저항력, 태양복사압, 조석력 등과 같은 다양한 섭동력의 영향에 대한 분석을 수행하였다. 셋째, 반경방향(radial), 진행방향(along-track), 교차방향(cross-track)의 세 방향의 성분으로 구성된 우주공간오차(Space Error) 개념을 적용하여, 투영된 지상궤적에 상응하는 오차를 계산하는 것 보다 안정적으로 오차를 계산하였다. 또한 운용요구사항에 따라 허용된 범위 내에서 궤도를 유지하기 위해 GVE(Gauss Variation Equation)을 이용한 궤도조정을 수행하였다. 섭동력의 분석 결과로부터 지구대기저항력, 달-태양 중력으로 인해 가장 두드러지는 장반경과 궤도이심률의 변화를 조정하기 위해, 임무에 사용되는 추력기의 연료 효율을 고려하여 동결궤도가 유지될 수 있는 최적의 위도이각에서 In-plane에 대한 궤도조정만을 수행하여 장반경과 이심률을 동시에 조정하였다. 지구대기와 태양활동의 영향으로 시간에 따른 장반경의 변화율에 따라 궤도조정 주기를 가지는 것을 알 수 있었고, 이 변화율 때문에 생기는 우주공간오차의 증가를 보정하여 위성의 지상궤적을 목표범위 안에서 유지할 수 있었다.

  • PDF

Real-time Underground Facility Map Production Using Drones (드론을 이용한 실시간 지하시설물도 작성)

  • NO, Hong-Suk;BAEK, Tae-Kyung
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.20 no.4
    • /
    • pp.39-54
    • /
    • 2017
  • Between 1998 and 2010, the computerization of underground facilities was completed in 84 cities. Since 2011, new pipelines have been laid or existing pipelines have been maintained, renovated, and renewed. To measure the exact location and depth of the exposure pipe, a map of underground facilities was created before filling the ground. This method is based on the time when the underground facilities of the National Geographic Information Institute Regulation No. 134 of the National Geographic Information Office revised in 2010 were drafted. The process of the drone taking the video is based on a theoretical basis of ground control points. The method works by removing all ground control points located outside of the error range and re-processing it for calculating the best result. Furthermore, using a drone-based spontaneous measuring method allows workers to obtain a high accuracy underground facilities map in error bound. The proposed method could be used as a new way to standardize the processing.

Experimental study for analysis of hydraulic characteristics around dams (댐 주변의 수리특성 분석을 위한 실험적 연구)

  • Baek, Donghae;Yoon, Jae-Seon;Lee, Byeong Wook;Jang, Eun Cheul;Song, Hyun-Gu
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.257-257
    • /
    • 2022
  • 댐 건설은 홍수 및 가뭄에 대응하기 위한 구조적 방법으로써 우리나라와 같이 지표수에 의존적인 지역에서는 가용 수자원을 확보하기 위한 확실한 수단으로 활용되어왔다. 신규 댐의 건설은 대상 하천의 수리학적 특성에 큰 변화를 야기할 수 있으며, 댐의 안정성 및 하천의 하도보호를 위해 댐 주변의 수리적 특성의 변화에 대해서도 사전에 인지하여 설계 시 반영할 필요가 있다. 수공구조물 신설에 따라 변화되는 수리학적 특성을 분석하는 방법으로는 그 수단에 따라 상사법칙을 적용한 수리모형실험과 수치기법을 활용한 수치모형실험으로 나눌 수 있다. 본 연구에서는 수리모형실험을 통한 실험적 방법을 이용하여 댐 상하류 구간의 수리학적 특성을 분석하였다. 해당 실험은 한국농어촌공사 농어촌연구원의 대형수리모형실험시설에서 수행되었다. 적용대상 댐의 제원은 높이 약 70m, 길이 약 230m이며, 폭 55m의 여수로를 포함하는 구조로 설정하였다. 수리모형은 Froude 상사법칙을 적용하여 1/30 규모로 축소하였으며, 콘크리트 및 아크릴 재료를 이용하여 제작되었다. 댐 모형이 설치되는 하천구간은 댐 구조물을 포함하여 실규모를 기준으로 흐름방향으로 약 800m, 하폭방향으로 약 450m의 범위를 포함하도록 설계되었으며, 하류구간에 사행하천이 존재하는 것이 특징이다. 본 실험에서 유량은 총 12개의 펌프를 이용하여 공급되었으며, 최대 4cms에 해당하는 유량공급이 가능하도록 설계하였다. 공급유량은 정교한 절차에 의해 보정된 전자식 유량계를 통해 통제되었으며, 사용된 유량계의 허용오차는 약 0.5% 수준인 것으로 나타났다. 수위 측정은 오차범위 0.05mm 수준의 초음파 수위측정기를 이용하였으며, 유속측정은 약 0.5cm/s의 정확도를 지닌 3차원 전자기 유속계를 이용한 접촉식 측정과 흐름구조 가시화를 위한 비접촉식 입자추적기법을 병행하였다. 실험조건은 실규모 기준으로 방류량 3,000~5,000cms에 대해 수행하였으며, 각 방류량별 댐 상하류의 흐름패턴에 대해 정량적으로 분석하였다.

  • PDF

Optical coupling coefficients and packaging of optical transmitter module for optical subscriber (광가입자용 수동광정렬형 광송신 모듈에 대한 광결합 효율 및 패키징)

  • 김상곤;송민규
    • Korean Journal of Optics and Photonics
    • /
    • v.11 no.3
    • /
    • pp.179-186
    • /
    • 2000
  • Optical coupling coefficients and misalignment tolerance of 155 Mbps optical transmitter module of passive alignment technology, to be usable in ATM system, B-NT (Broadband Network Termination) system, and 10 G transmission system for information super-highway networks, were calculated, compaired with it's engineer samples, and discussed. These engineer samples of -4.5 dBm maximum output power were packaged in the method of butt coupling of flat-fiber and tested reliability evaluation. Hence the cheap packaging method of optical transmitter module was researched. rched.

  • PDF

An Experimental Analysis of Approximate Conversions for B-splines (B-spline에 대한 근사변환의 실험적 분석)

  • Kim Hyeock Jin
    • Journal of the Korea Society of Computer and Information
    • /
    • v.10 no.1 s.33
    • /
    • pp.35-44
    • /
    • 2005
  • The degree reduction of B-splines is necessary in exchanging parametric curves and surfaces of the different geometric modeling systems because some systems limit the supported maximal degree. In this paper, We provide an our experimental results in approximate conversion for B-splines apply to degree reduction. We utilize the existing Bezier degree reduction methods, and analyze the methods. Also, knot removal algorithm is used to reduce data in the degree reduction Process.

  • PDF

사용후 핵연료 금속저장체에 대한 핵임계 안전해석

  • 신희성;신명원;신영준;김익수;노성기;김명현
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.10a
    • /
    • pp.197-202
    • /
    • 1997
  • ORIGEN2코드의 검증계산을 통해 PWR 사용 후 핵연료 조성핵종의 핵종량에 대한 핵임계측면에서 보수성을 가지는 안전인자를 산출하였고, MCNP코드의 검증계산으로 95/95 신뢰구간에서의 계산오차를 구하였다. 이를 바탕으로 직경이 1.2567cm이고 길이가 380.5cm인 196 개 금속봉을 장전한 캐니스터 ( 금속저장체 )가 x-y 방향으로 무한히 배열된 경우에 대해 캐니스터의 두께, 간격 및 외부의 공기중 수분농도에 따른 핵임계 안전해석을 수행하였다. 그 결과, 캐니스터의 두께가 7mm일 때 공기중 수분농도가 0.30 g/㎤이고 캐니스터간의 간격이 6.0cm인 경우의 최종핵 임계도값은 0.94130로서 최대허용핵임계값 (0.942)보다 적은 값을 보였다.

  • PDF

Iris Detection for Face Recognition (얼굴인식을 위한 눈동자 검출)

  • Han, Jun-Hee;Song, Yoon-Ho;Kang, In-Ha;Cheong, Ha-Young;Kang, Myung-Ku;Lee, Young-Sik;Bae, Cheol-Soo
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2005.05a
    • /
    • pp.823-826
    • /
    • 2005
  • 본 논문에서는 얼굴 영상으로부터 얼굴인식을 위한 눈동자를 검출하기 위한 방법을 제안하고자 한다. 제안된 방법은 분리 필터를 사용하여 홍채의 후보가 되는 영역을 구한 후 양자를 잇는 선분의 길이 및 기울기의 허용치 안에 있는 모든 영역에 대해 본 논문에서 제안한 방식으로 그 값을 계산한다. 이 값은 영역의 근방영역에서 홍채의 경계선에 대응하는 원을 허프변환으로 구했을 때 후보 영역의 원에서의 후보 영역과 인접하면서 분리된 영역 내의 평균 휘도 값 및 영역을 포함한 부분화상과 눈의 템프릿 사이의 정규화된 상관계수를 사용하여 계산된다. 그리고 그 값을 최소로 하는 영역들을 택하여 이것을 양눈의 홍채로 검출한다. 안경을 쓰지 않은 총 150장의 얼굴영상을 사용하여 실험한 결과 최대 97.3%, 최소 95.3%의 성공률을 얻을 수 있었으며, 약간의 오차를 허용한 경우에는 최대 99.3%, 최소 96.7%의 성공률을 얻을 수 있었다.

  • PDF

A Comparison of coincidence between the Light field & the Radiation field using film and BIS (필름과 BIS 영상장치를 이용한 광/방사선조사야 일치성 비교평가)

  • Bang, Dong-Wan;Seok, Jin-Yong;Jeong, Yun-Ju;Choi, Byeong-Don;Park, Jin-Hong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.2
    • /
    • pp.33-41
    • /
    • 2004
  • Purpose : Film has been the primary tool in coincidence testing between the light field and the radiation field, which constitutes the quality assurance list of a linear accelerator. But there is a great chance of errors being different among the observer when using film. Thus this study set out to use the BIS(Beam Image System) in addition to film in comparing and evaluating coincidence results between the two fields and in searching for the improvement measures. Materials & Methods : Photon beam of 6 and 15MV was exposed to film and the BIS using a linear accelerator. The light and radiation fields were each $50{\times}50,\;100{\times}100,\;and\;200{\times}200mm^2$. The gantry angle was $0^{\circ}$ when using film and $0^{\circ}\;and\;270^{\circ}$ when using the BIS. The devices adopted to test coincidence between the two fields were a ruler and film scanner when using film. With the BIS, the width of the scanned light and radiation fields was measured for errors with setting the X and Y axis. Results : The visual measurements of the observer with film resulted that the radiation field was bigger than the light field and that their maximum error was 1.9mm. The results were the same with the measurements using the film scanner except for the average error, which was less than 1.9mm. On the contrary, the measurements using the BIS showed that the light field was bigger than the radiation field at the gantry angle of $0^{\circ}\;and\;270^{\circ}$. The maximum error was 0.96mm, and the error range was $<{\pm}2mm$ both in the X and Y axis. The average error of ${\Delta}X$, Y was the smallest in the order of the visual film measurements, film scanner measurements, and BIS measurements Conclusion . This requires a careful measurement for accurate quality assurance since errors are much different according to each observer that tests coincidence between visual fields with film. And an observer needs to use another image device or develop a measuring device of his own if it seems necessary for accurate measurements.

  • PDF

Analysis of Variability Factors in Establishing Pesticide Residue Limits on Food Crops (농산물중 농약잔류 허용기준 설정시의 변이계수 분석)

  • Lee, Mi-Gyung;Lee, Su-Rae
    • Korean Journal of Food Science and Technology
    • /
    • v.37 no.3
    • /
    • pp.492-497
    • /
    • 2005
  • In establishing legal limits of pesticide residues, various default values are employed to compensate for unavoidable variability in data. Because permissible errors in residue analysis reach ${\pm}30-40%$ RSD, maximum residue limits (MRLs) follow geometric progression. According to 5-yr period JMPR reports, variability factor (ratio of highest to median values) in field residue trials was 3.8-fold in 486 crop-pesticide combinations and round-up effort from highest residue to MRL was 1.5-fold, whereas regulatory margin (ratio of MRL to highest residue) used in Korea was 4.8-fold in 822 crop-pesticide combinations; Korean MRLs will be set at higher levels as compared with Codex limits if these margins are employed. Validation studies to compare and harmonize Korean and Codex MRLs of pesticide residues on food crops should be undertaken.