• Title/Summary/Keyword: 최대 철근 간격

Search Result 38, Processing Time 0.025 seconds

Indirect Crack Controling Method Affected by Variation of Material Characteristics in Reinforced Concrete Flexural Members (재료 특성 변화에 따른 철근콘크리트 휨부재의 간접균열제어 방법 연구)

  • Choi, Seung-Won;Kim, Woo
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.1
    • /
    • pp.87-98
    • /
    • 2011
  • Crack formations are inevitable in reinforced concrete structures. To estimate crack widths, empirical formulae are used widely and indirect crack controling methods of limiting bar spacing and bar diameter are also used due to their simplicity. In EC2, the characteristic crack width is calculated by multiplying maximum crack spacing and average strain. In this study, limit values of maximum bar spacing and bar diameter are examined as the material characteristics are varied. Two models of tension stiffening effect and maximum crack spacing and their effects are evaluated. The obtained results are compared with the values obtained using KCI method. The results showed that a significant difference is found when two tension stiffening effect are employed, and an under-estimation is found when 2nd order tension stiffening effect and maximum crack spacing limit from Part II were implemented. Therefore, a rational indirect crack control method attained using the tension stiffening effect of 2nd order form is needed. Also, a consistency in serviceabiliy analysis in flexural members needs to be secured. In order to achieve these goals, two crack controling models are suggested.

Crack Control in Reinforced Concrete Flexural Members (철근콘크리트 휨부재의 균열 제어에 관한 연구)

  • Choi, Seung-Won;Kim, Woo
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.4
    • /
    • pp.471-478
    • /
    • 2011
  • For a practical simplicity in designing of reinforced concrete structures, the indirect crack controlling method of limiting bar spacing is adopted in KCI structural design provisions. In addition, a direct method for evaluating crack width is also provided in the appendix of the code. But there may be some mismatched results between these two crack controlling methods. In this study, limit values of maximum bar spacing calculated from KCI provisions, KCI appendix, and Frosch's equation are examined as concrete strength, cross-section height, and concrete cover are varied, and the differences are analyzed. From the results, it becomes clear that the differences between maximum bar spacing calculated from KCI code text provisions and those from KCI code appendix provisions are too significant to be neglected. Therefore, rational crack models are suggested in order to get rid of the discrepancy between the direct and indirect control methods.

Crack Spacing in RC Tension Members Considering Cover Thickness and Concrete Compressive Strength (피복두께와 콘크리트 강도를 고려한 철근콘크리트 인장부재의 균열간격)

  • Kim, Woo;Lee, Ki-Yeol
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.38 no.2
    • /
    • pp.193-202
    • /
    • 2018
  • This paper proposed a crack spacing calculation formulation which is an important parameter for calculating the crack width, that is the main factor for verification of serviceability limit states and durability performance evaluation of reinforced concrete members. The basic equation of average crack spacing is derived by considering the bond characteristics which is the governing equation for the analysis of cracking behavior in reinforced concrete members. In order to consider the effect of the cover thickness and concrete compressive strength, the crack spacing measured in 124 direct tensile tests performed by several researchers was analyzed and each coefficient was proposed. And, correlation analysis was performed from 80 specimen data where the maximum and average crack spacing were simultaneously measured, and a correlation coefficient that can easily predict the maximum crack spacing from the average crack spacing was proposed. The results of the proposed average crack spacing equation and maximum crack spacing correlation were compared with those current design code specification. The comparisons of proposed equations and the Korean design codes show that the proposed formulation for the average crack spacing and the maximum crack spacing improves the accuracy and reliability of prediction compared to the corresponding provisions of the Korean Concrete Structural Design Code and Korean Highway Bridge Design Code (Limit States Design).

Influence of Concrete Strength and Lateral Ties on Behavior of High-Strength Concrete Columns Subjected to Eccentric Compressive Load (편심 압축력을 받는 고강도 콘크리트 기둥의 거동에 미치는 띠철근 및 콘크리트 강도의 영향)

  • Lee, Young Ho;Chung, Heon Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.3
    • /
    • pp.95-104
    • /
    • 2007
  • This study was focused on the effect of concrete strength and lateral ties of concrete columns subjected to eccentric compressive loads. The twenty-four concrete columns with $200mm{\times}200mm$ square cross-section were tested. The main variables were concrete strength, spacing and configuration of lateral ties, and eccentricity ratios. From the experiment, the followings were investigated ; 1) In all cases, it was observed that the increase of concrete compressive strength led to the decrease of ductility. Also, as the eccentricity ratios increased, the effect of ductility enhancement by lateral ties decreased. 2) As the ties spacing decreased from 100mm to 30mm, the magnitude of axial load acting on the concrete column showed an enhancement of 1.1~1.2 times and the descending curve after a peak moment presented a smooth decline. 3) The high-strength concrete columns required a design of lateral ties to increase the volumetric ratios and density of tie spacing to sustain a proper strength and ductility. Accordingly, regardless of concrete strength, the current AIK design code to specify the maximum tie spacing of concrete columns was proven to lead to the poor strength and ductility for seismic design. Therefore, it is necessary to develop a new seismic design code that connects volumetric ratios and tie spacing of concrete columns with concrete strength.

Experiments and Analysis of Concrete Columns Confined with Lateral Reinforcements (횡구속된 콘크리트 기둥의 실험 및 해석)

  • 송하원;최동휴;변근주;김기수
    • Magazine of the Korea Concrete Institute
    • /
    • v.10 no.2
    • /
    • pp.167-178
    • /
    • 1998
  • 횡방향철근에 의하여 적절히 구속된 콘크리트 기둥은 강도증가 및 연성의 확보면에서 유리하다. 본 연구의 목적은 횡방향철근에 의하여 구속된 코아콘크리트의 크기,횡방향철근의 간격비 및 체적철근비 등의 변화에 따른 콘크리트 기둥의 극한강도를 포함한 최대하중 이전의 거동 및 최대하중 이후의 거동을 실험적, 해석적으로 고찰함으로써 콘크리트 기둥의 구속효과정도를 규명하려는데 있다. 본 연구에서는 횡구속된 콘크리트 기둥모형의 압축재하실험을 수행하였으며, 최대하중 이전의 거동에 대하여 연속체적 파괴와 소성을 고려한 3차원 모델링을 통한유한요소해석을 실시하였다. 또한 횡구속된 콘크리트 기둥의 변형률국소화 모델에 의한 파괴해석을 통하여 구속된 콘크리트 기둥의 최대하중 이후의 거동을 재현하였다. 해석결과는 압축재하실험의 결과와 비교, 분석되었으며, 이에 따른 구속효과를 규명하였다.

A Steel Spacing for Crack Control in RC Flexural Members with an Effective Modulus of Elastic (유효탄성계수를 반영한 철근콘크리트 휨부재의 균열제어를 위한 철근 간격)

  • Choi, Seung-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.5
    • /
    • pp.98-105
    • /
    • 2018
  • Cracks in RC members occurred as a result of material and structural factors. The crack width and a crack location are very difficult to examine. A direct crack control method and indirect crack control method to control a crack are presented in the KHBDC (LSD) and KSCDC (2012). In the KSCDC text, cracks are controlled by steel spacing indirectly under a service load. On the other hand, in the KSCDC appendix, cracks are controlled by a crack width directly under a sustained load. In particular, the loading state considered is different. On the other hand, cracks are controlled under a combination of service load and an effective elastic modulus is used in KHBDC. Therefore, in this study, an effective elastic modulus that can reflect the ratio of the sustained load and live load was applied, and a maximum steel spacing was calculated through a design crack width. A variable interpretation was carried out, and a rational crack control method was assessed. As a result, a steel spacing through the design crack width in the KSCDC was smaller than that from the design crack width in the KHBDC, which leads to a conservative design. In addition, the maximum steel spacing suggested in this study has a consistency eliminating the difference between direct crack control and indirect crack control.

Cracking Behavior of RC Tension Members Reinforced with Amorphous Steel Fibers (비정질 강섬유로 보강된 철근콘크리트 인장부재의 균열거동)

  • Park, Kyoung-Woo;Lee, Jun-Seok;Kim, Woo;Kim, Dae-Joong;Lee, Gi-Yeol
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.4
    • /
    • pp.475-482
    • /
    • 2014
  • This paper presents the experimental results concentrically reinforced concrete tension members and compares cracking behavior of amorphous steel fiber and normal steel fiber reinforced concrete members. Two kind of steel fibers were included as a major experimental parameter together with the six cover thickness to bar diameter ratio ($c/d_b$). The presence of amorphous steel fibers effectively controlled the splitting cracks initation and propagation. In the amorphous steel fiber reinforced specimens, no splitting cracks were observed that becomes higher with cover thickness to bar diameter ratio is 2.0. Crack spacing of the each specimens reinforced with amorphous steel fibers and normal steel fibers becomes larger with the increase in cover thickness, and also measured maximum and average crack spacing are significantly smaller than current design code provision. Based on the measured crack spacings, a relationships for predicting the crack spacing is proposed using the measured average crack spacing in amorphous steel fiber reinforced concrete tension members.

A Study on the Improvement of Durability Design of Underground RC Structures (RC 지하구조물의 내구성설계 개선에 관한 연구)

  • Im, Jung-Soon;Bahng, Yun-Suk
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.7 no.4
    • /
    • pp.13-18
    • /
    • 2007
  • The research was performed to review the design factors which affect the durability of structures. For the study, domestic and foreign literature review were performed on various design criteria. Based on Korean standard specifications, the results showed that the durability of structure as the diameter of reinforcing steel bar becomes smaller and the distance between reinforcing bar is closer than the normal gap. The results were also presented that the minimum required bar cover is 6.6cm to obtain the durability index value. In addition, the maximum limited bar cover was 12cm considering the durability index and the change of increasing value of durability index. In case that there is no specified regulation for the bar cover thickness change, the durability life by neutralization is proportional to the thickness of bar cover.

A FEA Study on the Bond Property according to the Rib-Shape of Reinforcement (철근 마디형상에 따른 부착특성에 관한 해석적 연구)

  • Mihn, Joon-Soo;Hong, Geon-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.2
    • /
    • pp.38-46
    • /
    • 2014
  • Effects of various parameters on bond property between reinforcing bar and concrete are investigated in many researchers, and various study is on going to improve the bond strength. Properties of interface between reinforcement and concrete is important role in bond property. This study analyzed the interfacial bond mechanism between deformed bar and concrete by finite element analysis (FEA) to evaluate the effect of rib shape. The FEA model in this study is simplified 2D plane stress model. The variables of analysis are selected by rib angle, rib height, rib spacing and relative rib area. From the results of analysis, reinforcing bars with rib angle $30{\sim}60^{\circ}$ showed better bond strength than the others. Bond strength ratio following to the rib height is proportionally increased up to the $0.12d_b$, but rib spacing has little effect on bond strength. The results also indicated that relative rib area can be efficiently represented the properties of deformed shape in reinforcing bars, and zigzagged rib height shape showed excellent bond strength increase.

The Investigation on Bond characteristics of Reinforced Concrete (철근콘크리트의 부착특성에 관한 연구)

  • 신성우;최종수;이광수
    • Magazine of the Korea Concrete Institute
    • /
    • v.7 no.1
    • /
    • pp.117-125
    • /
    • 1995
  • Bond test was carried out to assess the effect of several variables on bond characteristics between reinforcing bar and concrete. Key variables are concrete compressive strength($f_c$'=340, 460, 6513, 904kg/$cm^2$), concrete cover (25, 38, 51, 105, IlOmm), and bar diameter(Dl3 and D22). Confining effect and bar spacing are not taken into account. Thirty-two specimens subjected to uniaxial tension were tested under hypothesis uniform bond stress distribution along the reinforcing bar embeded in concrete. Failure mode was examined and local bond stress versus slip relationship diagrams were represented to show effect of the above variables, also test results(u1timate bond stress) were compared with bond and development provisions of the ACI Building Code(AC1 318-89) and proposed equations from previous research. According to analysis, borld stress and ultimate bond stress increased although compressive strength increased beyond the ACI Building Code upper limit. Therefore in calculating development length. compressive strength effect(exceeding 700kg /$cm^2$) should be accounted.