• Title/Summary/Keyword: 최대환기량

Search Result 83, Processing Time 0.022 seconds

Effects of Change in Heat Release Rate on Unsteady Fire Characteristics in a Semi-Closed Compartment (반밀폐된 구획에서 발열량 변화에 따른 비정상 화재특성)

  • Hwang, Cheol-Hong
    • Fire Science and Engineering
    • /
    • v.26 no.2
    • /
    • pp.75-83
    • /
    • 2012
  • An experimental study was conducted to investigate the effects of change in heat release rate on unsteady fire characteristics of under-ventilated fire in a semi-closed compartment. A standard doorway width of the full-scale ISO 9705 room was modified to 0.1 m and the flow rate of heptane fuel was increased linearly with time using a spray nozzle located at the center of enclosure. Temperature, heat flux, species concentrations and heat release rate were continuously measured and then global equivalence ratio (GER) concept was adopted to represent the unsteady thermal and chemical characteristics inside the compartment. It was observed that there was a significant difference in unsteady behavior between global and local combustion efficiency, and the GERs predicted by ideal and measured heat release rate were also shown different results in time. The unsteady behaviors of temperature, heat flux and species concentrations were represented well using the GER concept. It was important to note that CO concentration was gradually decreased with the increase in GER after reaching its maximum value in the range of 2.0~3.0 of global equivalence ratio. In addition, the experimental data on unsteady thermal and chemical behaviors obtained in a semi-closed compartment will be usefully used to validate a realistic fire simulation.

Elementary School in Gwangju Gwangsan Radon gas Density Measurement (광주광역시 광산구 소재 초등학교 라돈가스 농도 계측)

  • Ahn, Byungju;Oh, Jihoon
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.4
    • /
    • pp.211-216
    • /
    • 2014
  • Radium is rock or soil of crust or uranium of building materials after radioactivity collapse process are created colorless and odorless inert gas that accrue well in sealed space like basement. It inflow to lung circulate respiratory organ and caused lung cancer because of deposition of lung or bronchial tubes. In this study, the air in the elementary school classroom nongdoeul tonkatsu place of measured values were compared using the calculated annual internal radiation exposure. La tonkatsu exposure measured in primary school classroom at least five schools when you close the windows in the average floor 0.56mSv 2 floors ground floor windows when opened 0.384mSv 048mSv 3 floors, 2 floor levels of the same three layers 0.31mSv 0.296mSv the human exposure to radon and radiation on the first floor of 3 floors above ground in a lot of exposure was moderate. When you close the window from the first floor up 0.384mSv 056mSv 3 floors with a minimum annual radiation exposure due to natural radiation in the 16 to 23.3 percent minimum 2.4mSv accounted for. When I opened the window to the maximum annual radiation exposure 2.4mSv 0.296mSv 0.31mSv least a minimum of 12.3 to 12.91% accounted for Results suggest that more than five chodeunghakgyoeun La tonkatsu domestic radon measurements conducted below regulatory requirements and internal exposure has also fall within the normal range. People The less the radiation exposure to the human body because it reduces the impact in the classroom in elementary school vent windows often reduced to the maximum radon concentration in the air, if called tonkatsu be able to reduce radiation exposure for the immune system is weak and elementary will be helpful to experiment more in the future for the school authorities called tonkatsu investigation is done to him if the action to establish a more secure school building facilities is thought would be helpful.

Comparison of Forced Vital Capacity and Maximal Voluntary Ventilation Between Normal and Forward Head Posture (정상자세와 머리전방자세 사이의 강제폐활량과 최대 수의적 환기량 비교)

  • Han, Jin-Tae;Go, Min-Ji;Kim, Yeong-Ju
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.10 no.1
    • /
    • pp.83-89
    • /
    • 2015
  • PURPOSE: The purpose of this study was to investigate the vital capacity and maximal voluntary ventilationin subjects with forward head posture (FHP). METHODS: Twenty-eight subjects participated in this study (normal 14, FHP 14) and were resident in B city. The mean age, height and weight of subjects was 22.80yrs, 169.36cm and 62.79kg. Subjects were asked to breath maximally for FVC and repeatedly for MVV during 12 seconds. The variables of data were collected as follows: Forced Vital Capacity(FVC), Forced Expiratory Volume in One Second($FEV_1$), $FEV_1$/FVC, Maximal Voluntary Ventilation(MVV). Each trial was performed by 3 times and we used the means to analyze the data. The mann-whitney U test and independent t-test were used to compare the vital capacity between normal and FHP subjects. All statistical analyses were performed using SPSS 21.0 for window versionand p-values less than 0.05 were used to identify significant differences. RESULTS: The FVC, $FEV_1$, $FEV_1$/FVC and MVV of FHP subjects were decreased more than that of normal subjects and the difference was statistically significant between two groups. CONCLUSION: The vital capacity of subjects with FHP was generally lower than normal subjects. This study shows that the vital capacityof subjectswith FHP could be decreased due to the bad neck posture that weakens the respiratory accessory muscles of neck.

Changes in Fire Characteristics according to the Distance Between the Fire Source and Sidewall in a Reduced-Scale Compartment (축소 구획실에서 화원과 측벽의 거리에 따른 화재특성 변화)

  • Yun, Hong-Seok;Hwang, Cheol-Hong
    • Fire Science and Engineering
    • /
    • v.33 no.1
    • /
    • pp.50-59
    • /
    • 2019
  • Experimental and numerical studies on the fire characteristics according to the distance between the fire source and sidewall under the over-ventilated fire conditions. A 1/3 reduced ISO 9705 room was constructed and spruce wood cribs were used as fuel. Fire Dynamics Simulator (FDS) was used for fire simulations to understand the phenomenon inside the compartment. As a result, the mass loss rate and heat release rate were increased due to the thermal feedback effect of the wall in the compartment fire compared to the open fire. As the distance between the fire source and sidewall was reduced, the major fire characteristics, such as maximum mass loss rate, heat release rate, fire growth rate, temperature, and heat flux, were increased despite the limitations of air entrainment into the flame. In particular, a significant change in these physical quantities was observed for the case of a fire source against the sidewall. In addition, the vertical distribution of temperature was changed considerably due to a change in the flow structure inside the compartment according to the distance between the fire source and sidewall.

A Comparative Study on the Effects of Maximum Voluntary Ventilation and Abdominal Muscle Thickness through Two Kegel Exercise Postures (두 가지 케겔 운동 자세를 통한 최대 수의 환기량과 배 근육 두께의 효과 비교 연구)

  • Park, Hankyu
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.8 no.4
    • /
    • pp.39-47
    • /
    • 2020
  • Purpose : The purpose of this study was to investigate a comparative study on the effects of maximum voluntary ventilation (MVV) and thickness of the abdominal muscles through two Kegel exercise postures. Methods : Twenty eight (male= 7, female= 21) subjects participated in this experiment. They performed Kegel exercise in sitting and hooklying. The order of exercise was conducted in the order chosen by the subjects to exclude the learning effect. The MVV was measured using a spirometer. The thickness of the abdominal muscles were measured by ultrasound. The MVV and thickness of the abdominal muscles were measured according to the manual in a sitting and hooklying position before the experiment. After each exercise, the MVV and thickness of the abdominal muscles were also measured in the same way. A one way repeated measures analysis of variance (ANOVA) was used to compare the MVV and thickness of the abdominal muscles according to two postures and post hoc analysis, Bonferroni was used. Results : As a result of this study, significant differences in the MVV were observed after exercise than before exercise (p<.05). However, as a result of post hoc analysis, there was no difference in the MVV according to the postures (p>.05). Significant differences in thickness of the abdominal muscles were observed after exercise than before exercise (p<.05). However, as a result of post hoc analysis, there was no difference in thickness of the abdominal muscles according to the postures (p>.05). Conclusion : Based on the results of this study, the MVV and the thickness of the abdominal muscles were confirmed in the sitting and hooklying posture after Kegel exercise. However, further studies on vital capacity and abdominal muscles according to Kegel exercise postures should be conducted.

A Comparative Study of the Effects of Stair Exercise and Kegel Combined Exercise on the Maximum Voluntary Ventilation and Limits of Stability (계단 운동과 케겔 복합 운동이 최대 자발적 환기량과 안정성의 한계에 미치는 비교 연구)

  • Park, Kang-Hui;Park, Han-Kyu
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.9 no.3
    • /
    • pp.69-78
    • /
    • 2021
  • Purpose : The purpose of this study was to investigate the effect of stair exercise and Kegel combined exercise on the maximum voluntary ventilation (MVV) and limits of stability (LOS). Methods : 23 female students participated in this experiment. MVV was measured with a spirometer. The LOS was measured with a Biorescue. Subjects were randomly assigned to two groups. 12 subjects were assigned to the experimental group and 11 subjects were assigned to the control group. The experimental group performed 5 minutes of stair exercise and 5 minutes of Kegel exercise. The control group performed 10 minutes of stair exercise. After 5 minutes of exercise, 1 minute of rest was provided. Both groups exercised for 5 minutes according to the metronome beat 130 during the stair exercise. After 5 minutes of rest after exercise, MVV and LOS were measured again in the same way. The measurement sequence was also randomly alternated. Results : Significant differences were found within and between groups in the experimental group in MVV (p<.05). In LOS, significant differences were confirmed in left, right, forward, backward, and total LOS in the experimental group (p<.05). In the control group, there were significant differences in left, forward, and total LOS (p<.05). However, there was no significant difference between groups (p>.05). Conclusion : Based on the results of this study, it was confirmed that the stairs and Kegel combined exercise had a positive effect on MVV and LOS. However, in the short term, it was found that the stair and Kegel combined exercise was insufficient in time and the threshold of exercise to show the difference between groups in LOS. Therefore, additional research should be conducted by modifying the limitations of this study.

A Preliminary Study of the Effect of Kegel Exercise Using a Pressure Biofeedback Unit on Maximum Voluntary Ventilation and Abdominal Muscle Thickness (압력 생체되먹임 기구를 이용한 케겔 운동이 최대 수의적 환기량과 배 근육 두께에 미치는 사전 연구)

  • Lee, Kyung-Soon;Park, Kang-Hui;Park, Han-Kyu
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.10 no.1
    • /
    • pp.81-89
    • /
    • 2022
  • Purpose : Kegel exercises reported that it is effective in managing stress-related or complex urinary incontinence through contraction and relaxation of the pelvic floor muscles. In many previous studies, it was confirmed that Kegel exercise is involved in respiration as well as urinary system diseases. However, there is a lack of research on the effect of pelvic setting when performing Kegel exercises. Therefore, this study was conducted to investigate the effect on maximum voluntary ventilation (MVV) and abdominal muscle thickness through Kegel exercise after lumbar-pelvic motor control using pressure biofeedback unit (PBU). Methods : The subjects of this study were 10 healthy female students in their 20s. Subjects measured MVV with a spirometer. In hooklying, external oblique, internal oblique, and transverse abdominis of the dominant hand were measured using ultrasound. The measured value was an average of three times. After one week of intervention, measurements were made in the same manner. Before Kegel exercise, pelvic setting training was performed using PBU. In hooklying, PBU was placed in the waist and set to 40 mmHg, and it was adjusted to 60 mmHg through pelvic muscle contraction. For Kegel exercise, the pelvis was first set using PBU, and then the pelvic floor muscles were contracted for 8 seconds and relaxed for 8 seconds, 10 times, 1 set, and 3 sets. Results : In MVV, a significant difference was confirmed after exercise than before exercise (p<.05). There was also a significant difference in abdominal muscle thickness before and after exercise (p<.05). Conclusion : Based on the results of this study, Kegel exercise using PBU had an effect on MVV and abdominal muscle thickness. However, since this study was conducted without a control group as a preliminary study, additional research should be conducted to supplement this.

The Effect of Pelvic Floor Muscle Exercise Using a Smartphone Application on Abdominal Muscle Thickness and Maximum Voluntary Ventilation (스마트폰 애플리케이션을 이용한 골반바닥근육 운동이 배 근육 두께와 최대 자발적 환기량에 미치는 영향)

  • Han-Kyu Park;Dong-Kyu Lee;Jae-Cheol Park
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.11 no.3
    • /
    • pp.1-10
    • /
    • 2023
  • Purpose : This study was conducted to determine the effect of intervention using a smartphone application on abdominal muscle thickness and maximum voluntary ventilation when conducting pelvic floor muscle exercise (PFME). Methods : This study was performed on 14 subjects. They were divided into two groups; PFME using smartphone application (n=7), common PFME (n=7). Both of group executed the exercise 5 times a week for 1 weeks. Abdominal muscle thickness was measured using ultrasound. Maximum voluntary ventilation was measured using a spirometer. The smartphone application used the paid version of Kegel trainer. This material was analyzed by the paired t-test to compare differences on each group and the independent t-test to compare between the two groups. Results : The PFME group using the smartphone application showed a significant increase in the transverse abdominis and internal oblique muscles (p<.05). The common PFME group showed a significant increase in the internal oblique muscle (p<.05). There was no significant difference in variation of the muscle thickness between the two groups (p>.05). The PFME group using the smartphone application showed a significant increase in the maximal voluntary ventilation (p<.05). There was no significant difference in variation of the maximal voluntary ventilation between the two groups (p>.05). Conclusion : As a results of this study, PFME using a smartphone application seems to induce voluntary participation of subjects and maintain continuity against time constraints. As a result, it is thought that using a smartphone application when performing PFME is efficient and convenient in terms of research method. However, this study is difficult to generalize due to the small number of subjects and short intervention period. Therefore, additional research should be conducted by modifying and supplementing these limitations.

Assessment of Effect of Pulmonary Rehabilitation on Skeletal Muscle Metabolism by $^{31}P$ Magnetic Resonance Spectroscopy (호흡재활치료 전후 $^{31}P$ 자기공명분석법을 이용한 골격근대사의 변화에 관한 연구)

  • Cho, Won-Kyung;Kim, Dong-Soon;Choe, Kang-Hyeon;Park, Young-Joo;Lim, Tae-Hwan;Shim, Tae-Sun;Lim, Chae-Man;Lee, Sang-Do;Koh, Youn-Suck;Kim, Woo-Sung;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.5
    • /
    • pp.1040-1050
    • /
    • 1997
  • Pulmonary rehabilitation has been known to improve dyspnea and exercise tolerance in patients with chronic lung disease, although it does not improve pulmonary function. The mechanism of this improvement is not clearly explained till now; however some authors suggested that the improvement in the skeletal muscle metabolism after the rehabilitation could be a possible mechanism. The metabolc changes in skeletal muscle in patients with COPD are characterized by impaired oxidative phosphorylation which causes early activation of anaerobic glycolysis and excess lactate production with exercise. In order to evaluate the change in the skeletal muscle metabolism as a possible cause of the improvement in the exercise tolerance after the rehabilitation, noninvasive $^{31}P$ magnetic resonance spectroscopy(MRS) of the forearm flexor muscle was performed before and after the exercise training in nine patients with chronic lung disease who have undertaken intensive pulmonary rehabilitation for 6 weeks. 31p MRS was studied during the sustained isometric contraction of the dominant forearm flexor muscles up to the exhaustion state and the recovery period. Maximal voluntary contraction(MVC) force of the muscle was measured before the isometric exercise, and then 30% of MVC force was constantly loaded to each patient during the isometric exercise. After the exercise training, exercise endurance of upper and lower extremities and 6 minute walking distance were significantly increased(p<0.05). There were no differences of baseline intracellular pH (pHi) and inorganic phosphate/phosphocreatine(Pi/PCr). After rehabilitation pHi at the exercise and the exhaustion state showed a significant increase($6.91{\pm}0.1$ to $6.99{\pm}0.1$ and $6.76{\pm}0.2$ to $6.84{\pm}0.2$ respectively, p<0.05). Pi/PCr at the exercise and the recovery rate of pHi and Pi/PCr did not show significant differences. These results suggest that the delayed intracellular acidosis of skeletal muscle may contribute to the improvement of exercise endurance after pulmonary rehabilitation.

  • PDF

The Effect of Pulmonary Rehabilitation in Patients with Chronic Lung Disease (만성 폐질환 환자에서의 호흡재활치료의 효과)

  • Choe, Kang Hyeon;Park, Young Joo;Cho, Won Kyung;Lim, Chae Man;Lee, Sang Do;Koh, Youn Suck;Kim, Woo Sung;Kim, Dong Soon;Kim, Won Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.5
    • /
    • pp.736-745
    • /
    • 1996
  • Background : It is known that pulmonary rehabilitation improves dyspnea and exercise tolerance in patient with chronic lung disease, although it does not improve pulmonary function. But there is a controversy whether this improvement after pulmonary rehabilitation is due to increased aerobic exercise capacity. We performed this study to evaluate the effect of pulmonary rehabilitation for 6 weeks on the pulmonary function, gas exchange, exercise tolerance and aerobic exercise capacity in patients with chronic lung disease. Methods : Pulmonary rehabilitations including education, muscle strengthening exercise and symptom-Umited aerobic exercise for six weeks, were performed in fourteen patients with chronic lung disease (COPD 11, bronchiectasis 1, IPF 1, sarcoidosis 1 ; mean age $57{\pm}4$ years; male 12, female 2). Pre- and post-rehabilitaion pulmonary function and exercise capacity were compared. Results: 1) Before the rehabilitation, FVC, $FEV_1$ and $FEF_{25-75%}$ of the patients were $71.5{\pm}6.4%$. $40.6{\pm}3.4%$ and $19.3{\pm}3.8%$ of predicted value respectively. TLC, FRC and RV were $130.3{\pm}9.3%$, $157.3{\pm}13.2%$ and $211.1{\pm}23.9%$ predicted respectively. Diffusing capacity and MVV were $59.1{\pm}1.1%$ and $48.6{\pm}6.2%$. These pulmonary functions did not change after pulmonary rehabilitation. 2) In the incremental exercise test using bicycle ergometer, maximum work rale ($57.7{\pm}4.9$) watts vs. $64.8{\pm}6.0$ watts, P=0.036), maximum oxygen consumption ($0.81{\pm}0.07$ L/min vs. $0.96{\mu}0.08$ L/min, P=0.009) and anaerobic threshold ($0.60{\pm}0.06$ L/min vs. $0.76{\mu}0.06$ L/min, P=0.009) were significantly increased after pulmonary rehabilitation. There was no improvement in gas exchange after rehabilitation. 3) Exercise endurances of upper ($4.5{\pm}0.7$ joule vs. $14.8{\pm}2.4$ joule, P<0.001) and lower extremity ($25.4{\pm}5.7$ joule vs. $42.6{\pm}7.7$ joule, P<0.001), and 6 minute walking distance ($392{\pm}35$ meter vs. $459{\pm}33$ meter, P<0.001) were significantly increased after rehabilitation. Maximum inspiratory pressure was also increased after rehabilitation ($68.5{\pm}5.4$ $CmH_2O$ VS. $80.4{\pm}6.4$ $CmH_2O$, P<0.001). Conclusion: The pulmonary rehabilitation for 6 weeks can improve exercise performance in patients with chronic lung disease.

  • PDF