• Title/Summary/Keyword: 최대환기량

Search Result 83, Processing Time 0.021 seconds

Study on Ventilation Efficiency of a Mechanically Ventilated Broiler House­(I)Summer Season (강제환기식 육계사내의 환기효율성 조사연구­(I)하절기)

  • 이인복;정문성;유병기;전종기;김경원;이승기
    • Journal of Animal Environmental Science
    • /
    • v.9 no.2
    • /
    • pp.103-112
    • /
    • 2003
  • In this study, the distributions of internal climates such as air temperature, humidity, dust, ammonia gas, and air velocity were systematically measured at a mechanically ventilated broiler houses during summer season, with local weather data. The analysis was focused on the suitability, stability, and uniformity of internal climate, resulting in serious stress on chickens and decrease of productivity In the mechanically ventilated broiler house, the difference between measured and recommended air temperatures(suitability) was 10.4C in maximum during the summer time. The difference of air temperature in the house between day and night was $8.7^{\circ}C$ in maximum. And maximal hourly range of internal air temperature at 0.4m height from the floor was $3.7^{\circ}C$ suggesting it maintained thermal uniformity in the broiler house. The $NH_3$ and dust concentrations were pretty low because ventilation was fully performed. The air speed at chicken location was measured 2.2m/s and 1.7m/s, respectively without and with chicken existence.

  • PDF

사용후핵연료 중간저장 시설의 사고시 피복관의 산화 거동 연구

  • 유길성;김건식;민덕기;노성기;김은가
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.05b
    • /
    • pp.721-726
    • /
    • 1995
  • 사용후핵연료 중간저장 시설의 누수사고시 예상되는 SFLFL 컴퓨터 코드 분석 결과에 따른 실제 피복관의 산화시험 결과 저장용기 밑바닥 세가지 구멍은 크긴 조건들에 대히 환기회수가 시간당 0회인 경우는 사고후 48시간 경과시 매우 심각한 산화가 예상되며, 나머지 조건의 경우에는 48시간 산화 후 최대 산화량이 90mg/dm$^2$으로 시설의 누수사고시 산화막에 의한 영향은 거의 무시 할 수 있는 것으로 나타난다. 9가지의 시험조건중 안전성은 구멍의 크기가 7.62cm, 환기수가 시간당 2회인 경우가 가장 놓으며. 두번째는 구멍의 크기가 5.08cm, 시간당 환기수 2회의 경우였다. 같은 환기회수의 경우 구멍의 크기가 5.08과 7.62cm인 경우는 비슷하게 나타나지만 2.54와 5.08cm의 경우는 큰 차이를 보인다. 여기에서 수행된 시험은 미조사, 미전처리 시편을 사용한 것이므로 실제로 조사 및 로내 산화막이 입혀진 시편에 대한 추후 시험이 요구된다.

  • PDF

A numerical Study for Improvement of Indoor Air Quality of Apartment House (공동주택 단지의 실내 공기질 향상을 위한 수치 해석적 연구)

  • Shin, Mi-Soo;Kim, Hey-Suk;Hong, Ji-Eun;Jang, Dong-Soon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.7
    • /
    • pp.521-530
    • /
    • 2009
  • This study has been made to execute a research in order to lead the improvement of indoor air quality, examining the indoor ventilation characteristics by using a numerical analysis method. To this end an extensive parametric investigation are made according to various external flow variables such as main wind direction and wind speed by season, building layout design, and location of ventilators, etc. in Daedeok Techno Valley, one of large-scaled apartment in Daejeon. It is observed there was a significant difference of main wind direction between summer and winter. The main wind direction in summer was a south wind, and on the contrary the direction in winter is northnorthwest, which is similar to the average main wind direction for 10 years. One of the important calculation results is that the change of wind direction causes a significant effect on the apartment ventilation by the change of pressure difference around each complex of apartment. In case of favorable area of ventilation, the indoor ventilation rate can meet 0.7 ACH from the standard value only with natural ventilation. On the contrary, in other area the value was much lower than the standard value. If the calculation result applies to the design of layout apartment or placement of ventilators, it will be greatly helpful to the energy saving because it can be parallel with the natural ventilation to help securing ventilation rate, not much depending on the mechanical ventilation.

Study on Performance and Analysis of PF Heat Exchanger for Heat Pump Dryer (히트펌프 건조기용 PF 열교환기 성능 및 해석 연구)

  • Kim, Ki-Young;Lee, Seok-Hyun;Kwon, Young-Chul;Chun, Chong-Keun;Park, Sam-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.4
    • /
    • pp.1576-1581
    • /
    • 2013
  • In the present study, the performance of a PF heat exchanger for heat pump dryer was investigated. Capacity and dehumidification amount of the PF heat exchangers(PF1, PF2, PF3) by different inclination angles($0^{\circ}$, $30^{\circ}$, $60^{\circ}$) were studied. Experimental conditions were an air velocity crossing to the heat exchanger(0.5m/s), an air dry-bulb temperature($60^{\circ}C$) and relative humidity(70%). The experimental results have shown that the performance of the inclined PF heat exchangers was better than that of the vertically installed one. PF3 showed better performance compared to PF1 and PF2 due to the large pin pitch which are leading to more draining for dehumidified water. But, capacity and dehumidification amount of the PF heat exchanger at the inclination angles of $60^{\circ}$ was decreased due to pressure drop. Also, to predict the experimental data of the PF heat exchanger, the performance program was developed for the inclination angles of $0^{\circ}$. PF heat exchanger performance between experiment data and calculation data was satisfied within the maximum 2% for capacity and 3% for dehumidification amount.

Effects of Sports Drink Including the Extract from Prunus mume on the Changes of Respiratory Variables, Heart Rate, and Blood Lactate Concentration in Submaximal Exercise (매실함유 음료섭취가 장시간 운동시 심박수, 호흡가스 변인 및 혈중 젖산농도 변화에 미치는 영향)

  • 김기진;배지현
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.9 no.2
    • /
    • pp.177-187
    • /
    • 1999
  • This study was designed to investigate the effects of sports drink including the extract from Prunus mume on the changes of oxygen uptake, minute ventilaton, heart rate, and blood lactate concentration during 1 hour treadmill running exercise corresponding to 75%VO$_2$max. Subjects were 16 male athletes(long distance runners and tennis players). The changing patterns of oxygen uptake and minute ventilation showed no significnat difference among all types of sports drink, but the minute vetilation of the placebo group showed a higher value than type I group during submaximal exercise. Although the changing patterns of heart rate and blood lactate concentration showed no significnat difference among all types of sports drink, but type E group showed a lower heart rate compared to Placebo group. And blood lactate concentration of placebo group showed a higher value compared to the value corresponding to lactate threshold during submaimal exercise. but the other types of sports drink showed a lower value of blood lactate concentration. Especially blood lactate threshold of type D and E groups showed a lower value (range from 1.44 to 2.00mM) during submaximal exercise. In these results, the sports drink including the extract from Prunus mume showed no significant effects to the changes of oxygen uptake, minute ventilaton, heart rate, and blood lactate concentration during 1 hour treadmill runnuing exercise corresponding to 75%VO$_2$max. But it could be suggested the positive effects of the intake of sports drink including the extract from Prunus mume on the inhibition of exercise-induced fatigue during submaximal exercise, because of the lower changing Patterns of heart rate, blood lactate concentration, and ventilation efficiency in this results.

  • PDF

Analysis of the efficiency of natural ventilation in a multi-span greenhouse using CFD simulation (CFD 시뮬레이션을 이용한 연동형 온실 내 자연환기의 효율성 분석)

  • Short, Ted H.
    • Journal of Bio-Environment Control
    • /
    • v.8 no.1
    • /
    • pp.9-18
    • /
    • 1999
  • Natural ventilation in a four and one-half span, double polyethylene commercial greenhouse was investigated with actual data collected at Quailcrest Farm near Wooster, Ohio. Moreover, a computational fluid dynamics (CFD) numerical technique, FLUENT V4.3, was used to predict natural ventilation rates, thermal conditions, and airflow distributions in the greenhouse. The collected climate data showed that the multi-span greenhouse was well ventilated by the natural ventilation system during the typical summer weather conditions. The maximum recorded air temperature difference between inside and outside the greenhouse was 3.5$^{\circ}C$ during the hottest (34.7$^{\circ}C$) recorded sunny day; the air temperatures in the greenhouse were very uniform with the maximum temperature difference between six widely dispersed locations being only 1.7$^{\circ}C$. The CFD models predicted that air exchange rates were as high as 0.9 volume per minute (A.C. .min$^{-1}$ ) with 2.5m.s$^{-1}$ winds from the west as designed.

  • PDF

Ammonia Emission Characteristics of the Naturally Ventilated Growing-finishing Pig Building in Winter (자연환기식 육성${\cdot}$비육돈사와 동절기 암모니아 발생특성)

  • Lee, S. H.;Cho, H. K.;Kim, K. W.;Lee, I. B.;Choi, K. J.;Oh, K. Y.;Yu, B. K.
    • Journal of Animal Environmental Science
    • /
    • v.11 no.2
    • /
    • pp.103-110
    • /
    • 2005
  • The study was carried out to develop the real time measuring technique of ammonia and carbon dioxide concentration emitted from growing-finishing pig house in winter and estimate ammonia emission rate emitted from the pig house. As the study was carried out, environmental management technique for the pig house and odor abatement skill could be properly developed to reduce the residence's annoyance. The room temperature of the growing-finishing pig house was $10^{\circ}C$ higher than outdoor air temperature in spite of additional heating, because of heat emitted from body temperature of the pigs. The daily variation pattern of room temperature in the pig house shows the similar tendency with outdoor air temperature. The daily mean ventilation rate per head was $16\;m^3/h$ and ranged from $12\;m^3/h$ to $22.4\;m^3/h$. The difference of day and night for ventilation rate was about 2 times. The ammonia emission rate was $208{\pm}28\;mg/h{\cdot}pig$ per daily basics calculated with ventilation rate and ammonia concentration.

  • PDF

Analysis on the Ventilation Performance of Single-span Tomato Greenhouse with Roof Windows (천창을 설치한 토마토 재배 단동 온실의 환기성능 분석)

  • Nam, Sang-Woon;Kim, Young-Shik;Both, Arend-Jan
    • Journal of Bio-Environment Control
    • /
    • v.20 no.2
    • /
    • pp.78-82
    • /
    • 2011
  • Ventilation rates, inside and outside weather data were measured in a arch-shape single-span plastic greenhouse growing tomatoes. On the roof of the experimental greenhouse, round windows which have a diameter of 0.6 m were installed at intervals of 8m. It showed that the number of air changes in this greenhouse were average 0.17 volumes per minute and in the range of 0.02 to 0.32 volumes per minute. These air changes are insufficient to meet the recommended ventilation rate for commercial greenhouses, and it is estimated that interval of 6 m is appropriate for spring or fall season. For summer season, it is necessary to narrow the space or to enlarge the open area of roof windows. Using the heat balance model, the evapotranspiration coefficients of greenhouse tomatoes were estimated from experimental ventilation data, overall heat transfer and solar radiation. It showed that the evapotranspiration coefficients were average 0.62 and in the 0.39 to 0.85 range. We suggest applying 0.6 as the evapotranspiration coefficient in design of ventilation for the single-span tomato greenhouses.

A Study on the Airflow Distribution in the Diagonal Ventilation Circuit for the Design of a High Level Radioactive Waste Repository (고준위 방사성 폐기물 처분장 설계를 위한 Diagonal 환기 회로 내 공기량 분배에 관한 연구)

  • Hwang, In-Phil;Choi, Heui-Joo;Roh, Jang-Hoon;Kim, Jin
    • Tunnel and Underground Space
    • /
    • v.22 no.3
    • /
    • pp.173-180
    • /
    • 2012
  • In this study, diagonal ventilation circuits that are advantageous in air flow direction control were studied. Based on the results of the study, it could be seen that air volumes in diagonal ventilation circuits could also be calculated using numerical formulas or programs if the air volumes and air flow directions to be infused into diagonal branches are determined in advance as with other serial/parallel circuits. To apply the results, design plans for high level radioactive waste repositories applied with diagonal ventilation circuits and parallel ventilation circuits. To compared the each design plans and obtain expected operation results, ventilation network simulations were conducted through the Ventsim program which is a ventilation networking program. Based on the results, in the case of diagonal repositories that was expected to cause great increases in resistance, fan pressure was 1570 pa, total flux was 84 $m^3/s$, fan efficiency was 76.4%, fan power consumption was 181.2 kW and annual fan operating costs were 178,710,838 and thus maximum around 8% differences were shown in pressure and flux values and a difference of around 1.5% was shown in terms of operating costs.

The effect of heat exchanger type for exhaust heat recovery system on diesel engine performance (배기 열 회수 열교환기 형식이 디젤 엔진 성능에 미치는 영향)

  • Kim, Cheol-Jeong;Choi, Byung-Chul;Park, Kweon-Ha
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.6
    • /
    • pp.639-647
    • /
    • 2014
  • Due to global warming and depletion of fossil fuels, technologies reducing $CO_2$ emission and increasing fuel efficiency simultaneously are required. An exhaust gas heat recovery system is a technology to satisfy both issues. This study analyses three types of heat exchanger installed on an exhaust pipe. In case of plate type heat exchanger, back pressure rapidly increased and maximum cylinder pressure reduced in high speed and maximum load, and back pressure increased over twice and specific fuel consumption also increased up to 2% which were the highest increasing rate. In case of fin tube type, the amounts of exhaust emissions and specific fuel consumption rate were less than the other two types. The effect of shell and tube was in the middle. Making a decision by only the effect on engine performance, a fin tube type is the best for exhaust heat recovery systems.