• Title/Summary/Keyword: 최대신호대잡음비

Search Result 165, Processing Time 0.026 seconds

Q-factor Estimation of Seismic Trace Including Random Noise using Peak Frequency-Shift Method (무작위 잡음이 포함된 탄성파 트레이스로부터 Peak Frequency-Shift 방법을 이용한 Q-factor 추정)

  • Kwon, Junseok;Chung, Wookeen;Ha, Jiho;Shin, Sungryul
    • Geophysics and Geophysical Exploration
    • /
    • v.21 no.1
    • /
    • pp.54-60
    • /
    • 2018
  • The data acquired from seismic exploration can be used to detect the existence of oil and gas resources through appropriate processing and interpretation. The seismic attributes indicating the existence of resources are extracted from amplitude information, where the Q-factor representing intrinsic attenuation plays an useful role of hydrocarbon indicator. So, the accuracy of Q-factor estimation is very important to investigate the existence of resources. In this study, we calculated the Q-factor and analyzed the error rate through a numerical example. To mimic real data, random noise was added to the synthetic data. With the noise-added data, the Q-factor was estimated and the error rate was analyzed by using the spectral ratio method (SRM) and peak frequency shift method (PFSM). Both methods provided a relatively accurate Q-factor when the signal-to-noise ratio was 90 dB. However, the peak frequency shift method (PFSM) produced better results than the spectral ratio method (SRM) as the level of random noise increased.

Dynamic Allocation of Downlink Power for WCDMA Systems (WCDM 시스템에서 하향 링크 전력의 동적 할당)

  • Kim, Yeong-Ju;Choi, In-Han;Kang, Sung-Ho;Lee, In-Sung
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.44 no.10
    • /
    • pp.1-7
    • /
    • 2007
  • In WCDMA systems the down-link power allocation directly affects the cell deployment capacity, coverage, and system performances. Down-link power should be controlled at minimum but still satisfy the mobile stations' required signal to noise ratio. This paper mathematically proves that the down-link power allocation depends on the number of active mobile stations accessed to the base station. Therefore this paper proposes the dynamic down-link power allocation should be implemented to the WCDMA cellular systems.

A Study on Improving the Correlation Characteristics of a Ternary Sequence (삼치 시퀀스의 상관함수 특성 개선 연군)

  • 권성재
    • Proceedings of the Korea Society of Information Technology Applications Conference
    • /
    • 2002.11a
    • /
    • pp.407-411
    • /
    • 2002
  • Ternary sequences are digital codes consisting of discrete values -1, 0, and 1 only. They are advantageous in that the correlation can be carried out using additions only. Also, they feature an ideal circular autocorrelation function, but in channel characterization tasks, the usual requirement is that the linear autocorrelation function be ideal, i.e., a Kronecker delta function. In this article, we consider two approaches to improving their linear autocorrelation or crosscorrelation properties: one is an inverse filtering method with thresholding, and the other is a singular value decomposition (SVD) method. Both methods are simulated under noisy circumstances. The inverse filtering method resulted in an improvement in peak sidelobe level of about 11 dB at an SNR of 30 dB, and the SVD method showed similar performances, albeit more sensitive to noise depending on the singular value selection strategy.

  • PDF

A Study on Improving the Correlation Characteristics of a Ternary Sequence (삼치 시퀀스의 상관함수 특성 개선 연구)

  • 권성재
    • Proceedings of the Korea Society for Industrial Systems Conference
    • /
    • 2002.11a
    • /
    • pp.407-411
    • /
    • 2002
  • Ternary sequences are digital codes consisting of discrete values -1, 0, and 1 only. They are advantageous in that the correlation can be carried out using additions only Also, they feature an ideal circular autocorrelation function, but in channel characterization tasks, the usual requirement is that the linear autocorrelation function be ideal, i.e., a Kronecker delta function. In this article, we consider two approaches to improving their linear autocorrelation or crosscorrelation properties: one is an inverse filtering method with theresholding and the other is a singular value decomposition (SVD) method. Both methods are simulated under noisy circumstances. The inverse filtering method resulted in an improvement in peak sidelobe level of about 1㏈ at an SNR of 30㏈, and the SVD method showed similar performances, albeit more sensitive to noise depending on the singular value selection strategy.

  • PDF

Performance Analysis of a GPS Receiver under the Vacuum Environments (진공환경에서 GPS 수신기의 성능분석)

  • Moon, Ji-Hyeon;Kwon, Byung-Moon;Shin, Yong-Sul;Choi, Hyung-Don
    • Aerospace Engineering and Technology
    • /
    • v.8 no.1
    • /
    • pp.66-72
    • /
    • 2009
  • In order to verify the operability of a GPS receiver which is one of the KSLV-I onboard electrical equipments under the vacuum conditions, this paper describes the operation methods and performance results of the GPS receiver under the thermal-vacuum and vacuum environments. The damages and degradations of electrical parts of the GPS receiver caused by the pressure change and high-degree vacuum conditions are analyzed in terms of tracking and navigation capabilities through the signal-to-noise ratio and navigation error.

  • PDF

The characteristics of terahertz electromagnetic pulses by electrical and optical parameters. (전기적 광학적 변화가 테라헤르츠 전자기 펄스의 모양에 미치는 영향)

  • 전태인
    • Korean Journal of Optics and Photonics
    • /
    • v.12 no.6
    • /
    • pp.503-506
    • /
    • 2001
  • When DC voltages from 5 V up to 90 V are applied to a transmitter chip excited by an ultrafast lacer beam, the terahertz electromagnetic pulses and their spectra are changed. The spectrum shifts to the high frequency range when the high DC voltage is applied to the chip. At that time, the signal-to-noise ratio is increased from 250: 1 to 10,000: 1. The spectrum can expand up to 4 THz by optimal realignment of the THz system. Also, two terahertz electromagnetic pulses are generated from a receiver chip when the laser detection beam is reflected to the back side of the chip.

  • PDF

Development of Qualitative Evaluation of Medical Radiation Protective Apron (의료 방사선 방호용 앞치마의 정성적 평가법 개발)

  • Lim, Hui-Gyeom;Kim, Sang-Hyun;Kim, Tae-Hyung;So, Woon Young;Lee, Tae Hui;Kim, Seung Chul;Kim, Jin-Tae
    • Journal of radiological science and technology
    • /
    • v.40 no.3
    • /
    • pp.453-460
    • /
    • 2017
  • This study proposes effective quality control and maintenance method by developing a new qualitative evaluation method of apron for medical radiation protection. As an experimental material, one of 0.45 mm lead and 100 of 0.45 mm Pb aprons were used and irradiated under the conditions of a tube voltage of 75 kVp and a tube current of 12.5 mAs to obtain an image. and using the Image J program, PSNR values were compared and analyzed. The results showed that there were 40 aprons (less than 11dB), 55 aprons (less than 11dB, less than 30dB), and 5 aprons (30dB or more). In addition, the dose showed a normal distribution for the apron, and 5 aprons with PSNR less than 11dB and 30dB or more were selected and divided into 8 zones, and these groups were statistically significant.

Video Replay by Frame Receive Order Relocation Method in the Wire and Wireless Network (유무선 네트워크에서 프레임 수신 순서 재할당 방법을 사용한 동영상 재생)

  • Kang, Dong-Jin;Kim, Dong-Hoi
    • Journal of Digital Contents Society
    • /
    • v.17 no.3
    • /
    • pp.135-142
    • /
    • 2016
  • When video service is performed in simulation using NS-2(Network Simulation-2), the video replay is performed as the received frame order. In the existing video replay method based on the received frame order, as the frame orders of receiver and transmitter are different, the receiver buffer does not have the effect that the packets between the frames of transmitter buffer holds a regular size and packet dense and sparsity phenomenon in the receiver buffer is made by the irregular packet size due to the unpredictable reversed order of received partial frames. The above dense and sparsity phenomenon increases the probability of buffer overflow and underflow generation. To prevent these problems, the proposed frame receive order relocation method adds an extra replay buffer which rearranges the order of receive frame as the order of transmit frame, so it has the effect that the packets between the transmit frames keeps a regular size. Through the simulation using NS-2 and JSVM(Joint Scalable Video Model), the generation number of buffer overflow and underflow, and PSNR(Required Peak Signal to Noise Ratio) performance between the existing method and proposed method were compared. As a result, it was found that the proposed method would have better performance than the existing method.

Comparative Evaluation of 18F-FDG Brain PET/CT AI Images Obtained Using Generative Adversarial Network (생성적 적대 신경망(Generative Adversarial Network)을 이용하여 획득한 18F-FDG Brain PET/CT 인공지능 영상의 비교평가)

  • Kim, Jong-Wan;Kim, Jung-Yul;Lim, Han-sang;Kim, Jae-sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.24 no.1
    • /
    • pp.15-19
    • /
    • 2020
  • Purpose Generative Adversarial Network(GAN) is one of deep learning technologies. This is a way to create a real fake image after learning the real image. In this study, after acquiring artificial intelligence images through GAN, We were compared and evaluated with real scan time images. We want to see if these technologies are potentially useful. Materials and Methods 30 patients who underwent 18F-FDG Brain PET/CT scanning at Severance Hospital, were acquired in 15-minute List mode and reconstructed into 1,2,3,4,5 and 15minute images, respectively. 25 out of 30 patients were used as learning images for learning of GAN and 5 patients used as verification images for confirming the learning model. The program was implemented using the Python and Tensorflow frameworks. After learning using the Pix2Pix model of GAN technology, this learning model generated artificial intelligence images. The artificial intelligence image generated in this way were evaluated as Mean Square Error(MSE), Peak Signal to Noise Ratio(PSNR), and Structural Similarity Index(SSIM) with real scan time image. Results The trained model was evaluated with the verification image. As a result, The 15-minute image created by the 5-minute image rather than 1-minute after the start of the scan showed a smaller MSE, and the PSNR and SSIM increased. Conclusion Through this study, it was confirmed that AI imaging technology is applicable. In the future, if these artificial intelligence imaging technologies are applied to nuclear medicine imaging, it will be possible to acquire images even with a short scan time, which can be expected to reduce artifacts caused by patient movement and increase the efficiency of the scanning room.

Evaluation of Combined Contrast Agent using N-(p-maleimidophenyl) Isocyanate Linker-mediated Synthesis for Simultaneous PET-MRI (동시 PET-MRI를 위한 N-(p-maleimidophenyl) isocyanate linker-매개 합성을 이용한 복합 조영제의 평가)

  • Lee, Gil-Jae;Lee, Hwun-Jae;Lee, Tae-Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.2
    • /
    • pp.103-113
    • /
    • 2022
  • In this paper, a combined 18F-FDG(fluorodeoxyglucose) and MNP(magnetic nanoparticles) contrast agent was synthesized using N-(p-maleimidophenyl) isocyanate as the crosslinker for use in simultaneous PET-MRI scans. PET-MRI images were acquired and evaluated before and after injection of the combined contrast imaging agent (18F-FDG labeled MNP) from a glioma stem cell mouse model. After setting the region of interest (ROI) on each acquired image, the area of the lesion was calculated by segmentation. As a result, the PET image was larger than the MRI. In particular, the simultaneous PET-MRI images showed accurate lesions along with the surrounding soft tissue. The mean and standard deviation values were higher in the MRI images alone than in the PET images or the simultaneous PET-MRI images, regardless of whether the contrast agent was injected. In addition, the simultaneous PET-MRI image values were higher than for the PET images. For PSNR experiments, the original image was PET Image using 18F-FDG, MRI using MNPs, and MRI without contrast medium, and the target image was simultaneous PET-MRI image using 18F-FDG labeled MNPs contrast medium. As a result, all of them appeared significantly, suggesting that the 18F-FDG labeled MNPs contrast medium is useful. Future research is needed to develop an agent that can simultaneously diagnose and treat through SPECT-MRI imaging research that can use various nuclides.