• Title/Summary/Keyword: 촬영조건

Search Result 643, Processing Time 0.034 seconds

Analysis of the ESD and DAP According to the Change of the Cine Imaging Condition of Coronary Angiography and Usefulness of SNR and CNR of the Images: Focusing on the Change of Tube Current (관상동맥 조영술(Coronary Angiography)의 씨네(cine) 촬영조건 변화에 따른 입사표면선량(ESD)과 흡수선량(DAP) 및 영상의 SNR·CNR 유용성 분석: 관전류 변화를 중점으로)

  • Seo, Young Hyun;Song, Jong Nam
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.371-379
    • /
    • 2019
  • The purpose of this study was to investigate the effect of the change in the X-ray condition on the entrance surface dose (ESD) and dose area product (DAP) in the cine imaging of coronary angiography (CAG), and to analyze the usefulness of the condition change on the dose relation and image quality by measuring and analyzing the Signal to Noise Radio (SNR) and Contrast to Nois Ratio (CNR) of the angiographic images taken by the Image J program. Data were collected from 33 patients (24 males and 9 females) who underwent CAG at this hospital from November 2017 to March 2018. In terms of imaging condition and data acquisition, the ESD and DAP of group A with a high tube current of 397.2 mA and group B with a low tube current of 370.7 mA were retrospectively obtained for comparison and analysis. For the SNR and CNR measurement and analysis via Image J, the result values were derived by substituting the obtained data into the formula. The correlations among ESD and DAP according to the change in the imaging condition, SNR, and CNR were analyzed by using the SPSS statistical analysis software. The relationships of groups A and B, having a difference in the imaging condition, mA, with ESD ($A:483.5{\pm}60.1$; $B: 464.4{\pm}39.9$) and DAP ($A:84.3{\pm}10.7$; $B:81.5{\pm}7$) were not statistically significant (p>0.05). In the relationships with SNR and CNR based on Image J, the SNR ($5.451{\pm}0.529$) and CNR ($0.411{\pm}0.0432$) of the images obtained via the left coronary artery (LCA) imaging of group B showed differences of $0.475{\pm}0.096$ and $-0.048{\pm}0.0$, respectively, from the SNR ($4.976{\pm}0.433$) and CNR ($0.459{\pm}0.0431$) of the LCA of group A. However, the differences were not statistically significant (p<0.05). In the SNR and CNR obtained via the right coronary artery (RCA) imaging, the SNR ($4.731{\pm}0.773$) and CNR ($0.354{\pm}0.083$) of group A showed increased values of $1.491{\pm}0.405$ and $0.188{\pm}0.005$, respectively, from the SNR ($3.24{\pm}0.368$) and CNR ($0.166{\pm}0.033$) of group B. Among these, CNR was statistically significant (p<0.05). In the correlation analysis, statistically significant results were shown in SNR (LCA) and CNR (LCA); SNR (RCA) and CNR (RCA); ESD and DAP; ESD and sec; DAP and CNR (RCA); and DAP and sec (p<0.05). As a result of the analyses on the image quality evaluation and usefulness of the dose change, the SNR and CNR were increased in the RCA images of the CAG obtained by increasing the mA. Based on the result that CNR showed a statistically significant difference, it is believed that the contrast in the image quality can be further improved by increasing the mA in RCA imaging.

Calculation of At-sensor radiance for KOMPSAT-2 image collection planning (KOMPSAT-2 촬영계획을 위한 At-sensor radiance 계산)

  • Lee, Dong-Han;Seo, Doo-Chun;Song, Jeong-Heon;Choi, Myung-Jin;Yang, Ji-Yeon;Jung, Ho-Ryung;Lim, Hyo-Suk
    • Proceedings of the KSRS Conference
    • /
    • 2009.03a
    • /
    • pp.18-21
    • /
    • 2009
  • 2006년 발사되어 현재 운영 중인 아리랑위성 2호의 활용도를 높이기 위해서는 촬영 지역의 radiance 값에 따라 아리랑위성 2호의 TDI와 Vp gain 값을 조절해야만, 10bit인 radiometric resolution을 넓게 사용할 수가 있다. 촬영하고자 하는 지역의 radiance 값을 미리 예측하기 위해서, 한 픽셀이 $250km\times250km$인 월별 전 세계 radiance 평균값을 기본으로 촬영 날짜, 촬영 시각, 촬영 지역의 기후 조건 및 아리랑위성 2호의 ON-to-Radiance 변화 계수 값들을 사용하여서 최종 At-sensor radiance 값을 계산하는 알고리즘을 개발하였다. 실제 아리랑위성 2호의 자료수집계획 작성 시에 참고 값으로 사용 중이고, 80%이상의 정확도가 있음을 확인하였다.

  • PDF

Development of an Integrated Traffic Object Detection Framework for Traffic Data Collection (교통 데이터 수집을 위한 객체 인식 통합 프레임워크 개발)

  • Yang, Inchul;Jeon, Woo Hoon;Lee, Joyoung;Park, Jihyun
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.18 no.6
    • /
    • pp.191-201
    • /
    • 2019
  • A fast and accurate integrated traffic object detection framework was proposed and developed, harnessing a computer-vision based deep-learning approach performing automatic object detections, a multi object tracking technology, and video pre-processing tools. The proposed method is capable of detecting traffic object such as autos, buses, trucks and vans from video recordings taken under a various kinds of external conditions such as stability of video, weather conditions, video angles, and counting the objects by tracking them on a real-time basis. By creating plausible experimental scenarios dealing with various conditions that likely affect video quality, it is discovered that the proposed method achieves outstanding performances except for the cases of rain and snow, thereby resulting in 98% ~ 100% of accuracy.

A Study on the Optimization of Image Quality and Dose in Chest PA Digital Radiography (디지털 흉부 방사선 검사의 화질과 선량의 최적화에 관한 연구)

  • Park, Han Sol;Kim, Myeong Seong;Jung, Hong-Moon;Lee, Jong Woong
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.1
    • /
    • pp.55-61
    • /
    • 2017
  • There are no recommended test conditions for digital photography in Chest PA examinations. However, each company recommends shooting examinations of the high voltage applied to the previous analog examination. The condition that satisfies the value of 200 ~ 800 which is the recommended Exposure Index value recommended by Philips was selected, and the dose was evaluated by Monte Carlo simulation, and the SNR and CNR were compared. As a result, it was possible to reduce the effective dose up to 77% by controlling the tube voltage, tube current, and additional filter, not the conventional high voltage imaging method. Although there were some differences according to the test conditions, the image evaluation results were similar to the images. We will compare the exposure dose according to changes in tube voltage, tube current, and additional filter at the digital chest radiograph and evaluate the image quality of the image to propose optimal conditions.

Image Evaluation for Optimization of Radiological Protection in CBCT during Image-Guided Radiation Therapy (영상유도 방사선 치료 시 CBCT에서 방사선 방호최적화를 위한 영상평가)

  • Min-Ho Choi;Kyung-Wan Kim;Dong-Yeon Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.305-314
    • /
    • 2023
  • With the development of medical technology and radiation treatment equipment, the frequency of high-precision radiation therapy such as intensity modulation radiation therapy has increased. Image-guided radiation therapy has become essential for radiation therapy in precise and complex treatment plans. In particular, with the introduction of imaging equipment for diagnosis in a linear accelerator, CBCT scanning became possible, which made it possible to calibrate and correct the patient's posture through 3D images. Although more precise reproduction of the patient's posture has become possible, the exposure dose delivered to the patient during the image acquisition process cannot be ignored. Radiation optimization is necessary in the field of radiation therapy, and efforts to reduce exposure are necessary. However, when acquiring 3D CBCT images by changing the imaging conditions to reduce exposure, there should be no image quality or artefacts that would make it impossible to align the patient's position. In this study, Rando phantom was used to scan and evaluate images for each shooting condition. The highest SNR was obtained at 100 kV 80 mA 25 ms F1 filter 180°. As the tube voltage and tube current increased, the noise decreased, and the bowtie filter showed the optimal effect at high tube current. Based on the actual scanned images, it was confirmed that patient alignment was possible under all imaging conditions, and that image-guided radiation therapy for patient alignment was possible under the condition of 70 kV 10 mA 20 ms F0 filter 180°, which showed the lowest SNR. In this study, image evaluation was conducted according to the imaging conditions, and low tube voltage, tube current, and small rotation angle scan are expected to be effective in reducing radiation exposure. Based on this, the patient's exposure dose should be kept as low as possible during CBCT imaging.

The Study for Optimal Exposure Condition of Chest Examination of Digital Radiography System (디지털 방사선 촬영장치의 흉부촬영 최적 조사조건에 관한 연구)

  • Park, Ji-Koon;Jung, Bong-Jae;Park, Hyong-Hu;Noh, Si-Cheol;Kang, Sang-Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.2
    • /
    • pp.109-115
    • /
    • 2016
  • Despite of increasing the use of the digital imaging device in the radiology area, the setting on the optimal irradiation conditions are insufficient. In this study, the exposure dose and image quality by exposure condition of digital radiography device were compared. The exposure doses were obtained by adjusting the exposure condition as 5 steps respectively based on the exposure conditions that are currently used of CR and DR radiography devices. The acquired image has been assessed by 20 medical image professors using the assessment method of the Japanese Society for Tuberculosis Prevent. As a result, in the case of the CR system, the better image quality was obtained in the condition of 120 kVp and 1.5 mAs~2.4 mAs (quality score 91~95.5 points) than standard exposure condition(110 kVp, 3.2 mAs, 86 points). And exposure dose was evaluated as low with $61.3{\sim}98.4{\mu}Gy$ than standard condition($105.11{\mu}Gy$). In DR system, however, the image quality score was higher as 97~98.6 points in the lower tube voltage range (112 kVp, 2.4~3.2 mAs) condition than the standard exposure condition (125 kVp, 3.2 mAs, 91 points). In addition, the exposure dose was $61.5-77.2{\mu}Gy$ lower than standard condition($93{\mu}Gy$). In addition, the exposure dose was low as $61.5-77.2{\mu}Gy$ than standard condition($93{\mu}Gy$). With the results of this study, we confirmed that it is possible to reduce the patient exposure dose with the same image quality by adjusting the optimal exposure condition of digital device.

Design of Water Surface Hovering Drone for Underwater Stereo Photography (수중 입체촬영을 위한 수면호버링 드론 설계)

  • Kim, Hyeong-Gyun;Kim, Yong-Ho
    • Journal of Convergence for Information Technology
    • /
    • v.9 no.6
    • /
    • pp.7-12
    • /
    • 2019
  • In order to shoot underwater, the photographer must be equipped with shooting equipment and enter into the water. Since the photographer directly enters the water, safety accidents occur frequently due to various obstacles or deep water in the water. The proposed underwater stereo photography technique can solve the safety accident problem caused by the entry of the photographer into the water by using the drone for underwater photographing. In addition, this technique has the advantage of obtaining underwater images at low cost. In this study, the angle of the proposed cam for stereoscopic photography was analyzed and the condition that the proper stereoscopic image can be viewed was defined as the distance from the floor of 18cm to the floor distance of 41.4cm. This provision is proposed to be used to adjust the height of the shooting area descended by the elevation chain of the water surface hovering drones.

Accuracy Analysis on 3-D Coordinates According to the Variation of Photo Direction and of Convergent Angle in Close-Range Photogrammetry (근거리(近距離) 사진측량(寫眞測量)의 촬영방향(撮影方向)과 수렴각변화(收斂角變化)에 따른 3차원(三次元) 좌표결정(座標決定)의 정확도(正確度) 분석(分析))

  • Yeu, Bock Mo;Sohn, Duk Jae
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.9 no.4
    • /
    • pp.125-133
    • /
    • 1989
  • For convergent photos, which are now widely adopted for terrestrial facility survey, a number of experimental studies and theoretical studies on the developments of accuracy predictional model according to the convergent angle change have been accomplished. And such studies are basically depend on the symmetrical geometric configuration at the normal direction to the center of the object. However, in may cases of facility survey such as building facades, bridges, dam surfaces, relatively flat topography, etc., the object features are almost like planar, and frequently the surroundings do not allow the photo station at normal direction, and the sufficient convergent angle can be hardly achieved. Considering those points, in this study, the accuracy analysis on three dimensional coordinates according to the variations of photo direction and of convergent angle to the planar object were attempted, and the optimum geometric configurations at the normal, side-looking, and the most side-looking direction were investigated. The result through this study show that from normal direction to the side-looking direction angle ${\tau}=30^{\circ}$, the larger the convergent angle, the higher the accuracy, and in case that right photo is at the most side-looking direction, the better accuracy can be achieved according to the convergent angle increase up to $60^{\circ}$.

  • PDF

Doses of Pediatric and X-ray Examination Assistants according to Changes in Pediatric X-ray Exposure Conditions (소아 X선 촬영조건 변화에 따른 소아 및 촬영보조자 선량)

  • Beom-Jin Jang;Ha-Yun Nam;Hye-Min Shin;Dong-Min Yun;Seung-Kook Lee;In-Hwa Jang;Sungchul Kim
    • Journal of radiological science and technology
    • /
    • v.46 no.5
    • /
    • pp.409-415
    • /
    • 2023
  • Although pediatric X-ray examinations are continuously increasing, there are not many studies on the radiation exposure to children and X-ray examination assistants according to X-ray Exposure conditions. Accordingly, we measured the radiation exposure dose of pediatric and X-ray examination assistants according to the standard guidelines and clinical average X-ray Exposure conditions when X-ray examination 10-year-old children. The effective dose and organ dose to pediatric were measured using an Dose area production meter and Monte Carlo-based PCXMC program, and the exposure dose of X-ray examination assistants was measured using an ion-chamber. When performing abdominal supine AP projection, the effective dose to children was up to 2.38 times higher under clinical average X-ray Exposure conditions than the standard guidelines. In addition, during abdominal supine AP projection, the radiation exposure dose to the X-ray examination assistants was highest on the hands at 0.0148 ~ 0.0709 mSv, and exposure dose could be reduced by up to 35% when wearing protective gloves. In conclusion, because the X-ray Exposure conditions used in clinical are unnecessarily high, unnecessary medical radiation exposure could be reduced if appropriate X-ray Exposure conditions and the radiation field area were minimized and the assistant wore shielding gloves.

저궤도 관측용 다중 카메라 성능 및 활용 분석

  • Sin, Sang-Yun;Yong, Sang-Sun
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.225.2-225.2
    • /
    • 2012
  • 저궤도 관측용 다중 카메라를 통해 고해상도 위성을 제공할 수 있으며, 지도 제작이나 환경, 농업, 해양 지역 모니터링 등의 목적으로 사용될 수 있다. 특히 항공촬영 및 지구 관측을 통해 수치표고모델(DEM) 추출을 함으로써 촬영지역의 고도정보를 포함하는 입체영상을 얻는데 유용하다. 또한, 달 관측을 위한 관측위성에 장착할 경우 달 표면의 지형을 정밀하게 얻어내어 달표면 고도 지형 지도제작 및 향후 달 탐사선을 통한 달 탐사 시 탐사지역 선정에 필요한 정보를 제공할 수 있다. 다중 카메라를 포함한 탑재체 시스템은 크게 광학부와 카메라 전자부로 구성된다. 광학부에서는 입체촬영 및 줌인이 가능한 광학계를 제공하며, 카메라 전자부에서는 광학계를 통해 검출기로 입사되는 빛에너지를 전자신호로 변환하고, 이를 카메라 전자부 영상출력 형식으로 변환하게 된다. 특히, 다중카메라를 각각 제어하기 위한 정밀제어로직, 다양한 촬영 지원 모드, 다중카메라 영상자료 및 영상처리를 위한 추가적인 영상정보를 제공한다. 본 논문에서는 저궤도 관측용 다중 카메라를 이용한 다양한 활용에 따른 각 모드별 성능분석방법을 제안한다. 이를 위해 각 촬영조건에 따라 필요한 파라미터를 분석하고 실제 활용시 예상되는 성능을 분석해 본다. 또한 다중카메라를 통해 얻어진 영상을 처리하는데 필요한 처리 과정 및 처리된 영상을 활용하는 방법을 제시한다. 특히 다중 카메라 촬영을 통해 얻어진 영상데이터의 특성을 알아보고, 이를 보정 및 처리하기 위해 필요한 추가 적인 정보, 영상파라미터, 처리 단계 및 최종결과물을 검증하는 방법을 제시한다.

  • PDF