• 제목/요약/키워드: 총괄체적열전달계수

검색결과 4건 처리시간 0.018초

직접접촉식 열교환기내에서 물과 배기가스의 직접접촉에 의한 열 및 물질전달 (Heat and Mass Transfer between Hot Waste Gas and Cold Water in a Direct Contact Heat Exchanger)

  • 이금배
    • 대한기계학회논문집
    • /
    • 제16권6호
    • /
    • pp.1171-1178
    • /
    • 1992
  • 본 연구에서는 직접접촉식 열교환기를 이용한 실험을 통하여 열교환기 설계에 가장 중요한 열교환기 단위 체적당 총괄 열전달 계수를 시스템의 작동조건에 따라 구 하여 실제 설계자료로 이용하는 데 그 목적이 있다.

밀폐형 냉각탑의 열성능 특성에 관한 실험적 연구 (Thermal Performance Characteristics of Closed-Wet Cooling Tower)

  • ;김은필;문춘근;윤정인
    • 동력기계공학회지
    • /
    • 제9권2호
    • /
    • pp.88-92
    • /
    • 2005
  • The experiment of thermal performance about closed-wet cooling tower was conducted in this study. A closed cooling tower is a device similar to a general cooling tower, but with cooling tower replaced by a heat exchanger. The test section for this experiment has the process that the cooling water flows from the top of the heat exchanger to the bottom side in the inner part of the tube, and spray water flows in the gravitational direction in the outer side. Air comes in direct contact with the spray water at the outer side of the tube while passing from the lower the upper part having a counterflow to the spray water. The heat transfer pipe used in this experiment is a bare-type tube having an outer diameter of 15.88mm. The heat exchanger is consisted of seven rows and fifteen columns. In this experiment, thermal performance of the cooling tower is derived from overall heat transfer coefficients between the process fluid and sprayed water and volumetric overall mass transfer coefficient between sprayed water and air.

  • PDF

이중관 내부 나노유체의 유동방향 영향에 관한 연구 (A Study on the Effect of Nanofluids Flow Direction in Double Pipe)

  • 최훈기;임윤승
    • 한국기계가공학회지
    • /
    • 제20권6호
    • /
    • pp.82-91
    • /
    • 2021
  • We compared the heat transfer characteristics of the parallel and the counterflow flow in the concentric double tube of the Al2O3/water nanofluids using numerical methods. The high- and low-temperature fluids flow through the inner circular tube and the annular tube, respectively. The heat transfer characteristics according to the flow direction were compared by changing the volume flow rate and the volume concentration of the nanoparticles. The results showed that the heat transfer rate and overall heat transfer coefficient improved compared to those of basic fluid with increasing the volume and flow rate of nanoparticles. When the inflow rate was small, the heat transfer performance of the counterflow was about 22% better than the parallel flow. As the inflow rate was increased, the parallel flow and the counterflow had similar heat transfer rates. In addition, the effectiveness of the counterflow increased from 10% to 22% rather than the parallel flow. However, we verified that the increment in the friction factor of the counterflow is not large compared to the increment in the heat transfer rate.

액화석유가스 용기의 자연 증발량에 관한 연구 (A Study on the Natural Evaporation Capacity of LPG Container)

  • 조영도;김지윤
    • 한국가스학회지
    • /
    • 제5권2호
    • /
    • pp.22-29
    • /
    • 2001
  • 체적거래제에 의하여 소규모 공동주택에 가스를 공급하기 위하여 적절한 용기설치수의 결정 및 용기교체시기에 대한 검토가 필요하다. 그러나 지금까지 국내에 축적된 자료가 없을 뿐만 아니라 용기 설치수의 결정과 용기수 및 가스사용 형태에 따라 용기교체시 남아 있는 액화석유가스 양에 대한 이론적 검토가 없었다. 따라서 본 연구에서는 자연기화능력, 잔량, 용기의 온도, 용기내부 압력 등을 시뮬레이션으로 살펴보았다. 용기표면으로부터 액화석유가스 용기의 총괄 열전달계수의 변화에 따른 자연기화량 변화는 크지 않으며, 실험으로부터 구한 값은 약 $9{\~}13 kcal/m^2{\cdot}hr{\cdot}^{\circ}C$이었다. 그리고 액화석유가스 용기내부의 압력이 압력조정기의 압력조정 하한계에 도달하였을 때 가스방출 유량은 공기로부터 전달되는 열량과 균형을 이루는 일정한 값으로 급격히 감소하였다. LP가스용기의 자연기화능력은 외기온도 및 프로판의 조성에 따라 증가하였고, 연속사용시간에 따라 초기 급격히 감소하여 일정한 값으로 수렴하였다. 한 가구당 용기수는 자동절체기 사용에 의하여 감소시킬 수 있는 것을 알 수 있다.

  • PDF