• Title/Summary/Keyword: 총괄에너지 이용효율

Search Result 11, Processing Time 0.025 seconds

Experiment on the Charging and Discharging Processes of a Closed Ice-Thermal-Energy-Storage System (밀폐식 빙축열시스템의 축열 및 방열과정에 관한 실험)

  • Kim, Kyung-Hwan;Yoon, Young-Hwan;Kim, Yeon-Kyu
    • Journal of Energy Engineering
    • /
    • v.16 no.4
    • /
    • pp.164-169
    • /
    • 2007
  • The decrease in the summer peak electric load in our country is very important. The government has arranged and implemented a lot of support policies and statutes to decrease the peak electric load. And the ice-thermal-energy-storage system is known as one of the alternatives. The purpose of this paper is to evaluate the performance and the total efficiency of its storage tank, conducting the charging operation, the parallel operation and the single operation of a storage tank. The thermal energy density stored and discharging efficiency of a storage tank and the efficiency of total energy utilization of system are $18.4\;USRT-h/m^3$, 96.2% and 2028.7 kcal/kWh under the operation of design condition. When the storage tank is supplied more ice thermal energy than design condition, it is estimated that the efficiency of system are lower than the design condition by the supercooled effect.

Study on the Performance Testing of the Closed Ice Thermal Energy Storage System using Screw Capsules (스크류 캡슐형 밀폐식 빙축열시스템의 성능시험에 관한 연구)

  • Kim, Kyung-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.26 no.4
    • /
    • pp.39-45
    • /
    • 2006
  • The decrease in the summer peak electric load in our country is very important. The government has arranged and implemented a lot of support policies and statutes to decrease the peak electric load. And the ice thermal energy storage system is known as one of the alternatives. The purpose of this paper is to evaluate the efficiency and thermal characteristics of the closed ice thermal energy storage system using screw capsules. The measured thermal energy storage density is about 18.4 USRT-h/m3 (=232.9 MJ/m3), which is higher than 13.0 USRT-h/m3 (=164.6 MJ/m3), a low criterion of normal performance. And The efficiency of the discharging process and the total energy utilization is 96.2% and 2028.4 kcal/kWh respectively.

Development of Continuous Dechlorination Process with High Efficiency for the Industrial Utilization of Waste Plastic Fuel (폐플라스틱 연료의 산업체 이용을 위한 연속식 고효율 탈염공정개발)

  • Chung, Soo-Hyun;Kim, Sang-Guk;Woo, Je-Kyung;Na, Jeong-Geol
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.11a
    • /
    • pp.423-435
    • /
    • 2005
  • 본 연구는 PVC를 포함한 혼합플라스틱을 연료화하는데 있어서 가장 큰 장애요인으로 되어있는 염소분을 효율적으로 제거하기 위한 목적으로 진행되었다. 염소성분을 원천적으로 제거하기 위해서는 PVC 내에 함유된 염소분을 제거하는 것이 관건이며 원천탈염을 통하여 제거하지 않으면 총괄 염소분의 변화가 없기 때문에 실제로 연료사용에는 한계가 있는 경우가 많다. 본 연구는 PVC중 56% 이상 함유되어 있는 염소성분을 연속식 스크루 반응기에 의하여 가열하여 제거하는 방식을 사용하였으며 각 공정의 변수별로 제거효율을 분석하여 최적조업조건에 대한 분석을 실시하였다. 일반적인 공정조업조건은 공급량, 혼합 플라스틱의 점도, 2차 반응기의 온도, 스크루 회전수 등이며 이 가운데 가장 결정적인 조건은 가열온도 변수이며 여타의 최적조업조건 하에서 $300^{\circ}C$ 이상인 경우에는 90% 이상의 탈염효율을 유지할 수 있음을 알 수 있었다.

  • PDF

Behavior analysis using pressure fluctuations in a pressurized fluidized bed (가압유동층에서 압력변동을 이용한 거동해석)

  • Kang, Suk-Hwan;Han, Keun-Hee;Yi, Chang-Keun;Jin, Gyoung-Tae;Son, Jae-Ek;Kang. Yung
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2002.05a
    • /
    • pp.179-183
    • /
    • 2002
  • 가압유동층은 복합발전이 가능하며, 총괄열효율이 높을 뿐만 아니라 가압에 의한 장치의 소형화 및 탈황효율의 증대 그리고 배가스 중의 NOx 농도를 줄일 수 있기 때문에 공해 배출 물질의 감소 등 상압유동층 연소에 비하여 많은 장점들을 가지고 있어 선진 국가들에서도 이미 상당한 진전을 보이고 있으며, 중국이나 일본에서도 차세대 연소기술로 이에 대한 연구가 활발히 진행되고 있다.(중략)

  • PDF

수처리용 역삼투막 제조 및 System 설계

  • 김권일
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1997.04a
    • /
    • pp.63-84
    • /
    • 1997
  • 산업발전에 따라 발생하는 각종 오염물질에 의한 양질의 물 부족현간을 해결하거나 산업적으로 특정물질을 분리하기 위하여 새로운 분리기술이 개발되고 있으며 앞으로 인류에 대한 가장 절실한 기술로 떠오를 것이다. 이러한 측면에서 분리막은 가장 효율적인 분리기술로 여겨져 지난 30년간 눈부신 발전을 해왔고 최근 국내에서도 소재개발과 함께 이를 응용한 분리막 System개발이 활발히 이루어지고 있다. 분리막에 의한 공정은 상변화가 없는 분리공정이므로 에너지 측면에서 효율적이며 공정자체가 간단하여 점차 보편적인 기술로 자리를 잡아가고 그 기본원료가 부직포, 종공사나 장,단섬유이므로 주로 화섬회사위주로 소재개발이 주로 되고 있다. 본 발표에서는 최근에 국내에서 생산되기 시작한 역삼투막의 제조방법과 이를 이용한 System설계기술에 대하여 총괄적으로 소개하고자 한다.

  • PDF

A Study on the Effects of Etching Surface Characteristics on Condensation Heat Transfer in Pre-heating Exchanger (급기 예열 열교환기에서 에칭 표면 특성이 응축 열전달에 미치는 영향에 관한 연구)

  • Seok, Sungchul;Hwang, Seung Sik;Choi, Gyu Hong;Shin, Donghoon;Chung, Tae Yong
    • Journal of Energy Engineering
    • /
    • v.23 no.2
    • /
    • pp.217-222
    • /
    • 2014
  • In order to improve the heat efficiency of the general residential boiler, we performed an experiment of condensation heat transfer to air pre-heating exchanger adhered to the condensing boiler. In this study, surface roughness was imposed on the surface of stainless steel by etching. And in order to evaluate the heat transfer performance on each plate, the counter flow heat exchanger fabricated with polycarbonate in used. As a result, on etching treated plate's overall heat transfer coefficient is higher than the original plate. And etching treated plate during 60 seconds with etchant is the to average 15% compared to bare stainless steel. And we studied the heat transfer enhancement factor through the analysis of surface characteristics using AFM.

Economic Analysis for a Tidal Power Plant Project using RETScreen - Focused on the Tidal Power Plant in Asan Bay (RETScreen을 활용한 조력발전 개발사업 경제성 분석 - 아산만 조력발전소 사례를 중심으로 -)

  • Kim, Min-Ock;Jeong, Keun-Chae
    • Korean Journal of Construction Engineering and Management
    • /
    • v.14 no.4
    • /
    • pp.152-163
    • /
    • 2013
  • In this research, we analyse the economic feasibility of a tidal power plant project which can efficiently generate mass, permanent, predictable, and homogeneous electric power. For the economic feasibility analysis, we used the RETScreen that is developed at the CANMET Energy Technology Center in Natural Resources Canada and widely utilized for analysing the economic feasibility and sensitivity of clean energy projects. Results from the feasibility and sensitivity analysis showd that the tidal power plant project in Korea has a enough economic feasibility, and its feasibility increases more as certified emission reductions price and electricity unit price increase. Based on the results from the feasibility study, we can solve the energy problems to be come in near future by constructing the tidal power plants in Korea more aggressively.

PBFiltering: An Energy Efficient Skyline Query Processing Method using Priority-based Bottom-up Filtering in Wireless Sensor Networks (PBFiltering: 무선 센서 네트워크에서 우선순위 기반 상향식 필터링을 이용한 에너지 효율적인 스카이라인 질의 처리 기법)

  • Seong, Dong-Ook;Park, Jun-Ho;Kim, Hak-Sin;Park, Hyoung-Soon;Roh, Kyu-Jong;Yeo, Myung-Ho;Yoo, Jae-Soo
    • Journal of KIISE:Databases
    • /
    • v.36 no.6
    • /
    • pp.476-485
    • /
    • 2009
  • In sensor networks, many methods have been proposed to process in-network aggregation effectively. Unlike general aggregation queries, skyline query processing compares multi-dimensional data for the result. Therefore, it is very difficult to process the skyline queries in sensor networks. It is important to filter unnecessary data for energy-efficient skyline query processing. Existing approach like MFTAC restricts unnecessary data transitions by deploying filters to whole sensors. However, network lifetime is reduced by energy consumption for many false positive data and filters transmission. In this paper, we propose a bottom up filtering-based skyline query processing algorithm of in-network for reducing energy consumption by filters transmission and a PBFiltering technique for improving performance of filtering. The proposed algorithm creates the skyline filter table (SFT) in the data gathering process which sends from sensor nodes to the base station and filters out unnecessary transmissions using it. The experimental results show that our algorithm reduces false positives and improves the network lifetime over the existing method.

A Study of Closed OTEC Power Plants (폐쇄형 해양온도차발전 사이클에 관한 연구)

  • Shin, Sang-Ho;Jung, Dong-Soo;Kim, Chong-Bo;Seo, Tae-Beom;Chun, Won-Gee;Auh, P. Chung-Moo
    • Solar Energy
    • /
    • v.17 no.4
    • /
    • pp.23-33
    • /
    • 1997
  • In this paper, performance of various working fluids is evaluated for the closed Ocean Thermal Energy Conversion(OTEC) power plant operating on Rankine cycle. The evaporator and condenser are modeled via UA and LMTD method while turbine and pump are modeled by specifying isentropic efficiencies. R22, Propane, Propylene, R134a, R125, R143a, R32, R410A and Ammonia are used as working fluids. Results show that newly developed fluids such as R410A and R32 that do not cause stratospheric ozone layer depletion perform as well as R22 and ammonia. The superheat at the evaporator exit and subcooling at the condenser exit do not affect the performance of the simple OTEC power cycle. Turbine efficiency and heat exchanger size influence greatly the performance of the Rankine cycle. Finally, it was shown that closed OTEC power plants can practically generate electricity when the difference in warm and cold sea water inlet temperatures is greater than $20^{\circ}C$.

  • PDF

Heat Transfer Enhancement by Fins in a Latent Heat Storage System Using Phase Change Material (상변화물질을 이용한 축열시스템에서 핀에 의한 열전달 촉진 연구)

  • 한승구;한귀영
    • Journal of Energy Engineering
    • /
    • v.5 no.2
    • /
    • pp.115-122
    • /
    • 1996
  • Heat transfer characteristics of low temperature latent heat storage systems have been examined for the circular finned and unfinned tubes using Na$_2$B$_4$O$\_$7/10H$_2$O as a phase change material. In order to reduce the supercooling of PCM, 3 wt% of Na$_2$B$_4$O$\_$7/10H$_2$O was added as the nucleating agent and 2.2 wt% of acrylic acid sodium sulfate was used as the thickener. The heat storage vessel has dimension of 530 mm height, 74 mm 1.D. and inner heat transfer tube is 480 mm height and 13.5 mm O.D. Water was employed as the heat transfer fluid. During the heat recovery experiment, the heat recovery rate was affected by the flow rates and inlet temperature of heat transfer fluid. The enhancement of heat transfer by fins over the unfinned tube system was found to be negligible in the thin finned tube systems, whereas the heat transfer coefficient in the thick finned tube system is approximately 60% higher than that in the unfinned lobe system. The experimentally determined heat transfer coefficient for the unfinned tube and thick finned tube systems are 150-260 W/㎡$^{\circ}C$ and 230-530 W/㎡$^{\circ}C$, respectively. The fin efficiency based on the heat transfer coefficient and area increased by fins was found to be 0.05 and 0.26 for the thin and the thick finned tube systems.

  • PDF