• Title/Summary/Keyword: 초음파 진단장치

Search Result 75, Processing Time 0.025 seconds

Design and Fabrication of Linear Array Transducer for Ultrasonic Medical Imaging System (초음파 의료 진단 장치용 선형 배열 변환기의 설계 및 제작)

  • Cho, Yeong-Hwan;Sung, Keong-Mo
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1990 no.05
    • /
    • pp.29-32
    • /
    • 1990
  • In this paper, we designed and fabricated linear array transducer for ultrasonic medical imaging system. Fabricated transducer is 85mm in length and has 64 elements. It shows good sensitivity and band width characteristics compared with commercial transducers.

  • PDF

The Development of the Contamination Prevention Module of an Optical Window Using Ultrasonic Waves (초음파를 이용한 광학창 오염방지 모듈 개발)

  • Lee, ChangHee;Jeon, KiMun;Shin, JaeSoo;Yun, JuYoung;Cho, Seonghyun;Kang, Sang-Woo
    • Journal of the Korean Vacuum Society
    • /
    • v.22 no.4
    • /
    • pp.175-180
    • /
    • 2013
  • We developed the contamination prevention module of an optical window for an In-Situ Particle Monitor (ISPM) system. the core part of the module is the generator of an ultrasonic wave and the module is to remove particles stuck to the window by the transfer of the wave force to the window surface. In order to enhance transfer efficiency of the waves the frequency of the ultrasonic wave was optimized and a low impedance material (plexiglass) and a soft sealing material (Si rubber) were used. The ISPM with the developed module was installed at the exhaust line of a BPSG CVD equipment and the effect of the module was verified.

A Study on the Structural Relation among Purchase Decision Factors of Medical Devices, Satisfaction and Repurchasing Intention : Focused on Ultrasound Imaging System (의료기기의 구매결정요인과 만족 및 재구매 의도의 구조적 관계에 관한 연구 : 초음파영상진단장치를 중심으로)

  • Jung, Tae-young;Seo, Geon-seok;Kim, Su-beom
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.5
    • /
    • pp.3308-3314
    • /
    • 2015
  • The purpose of this study is to investigate the casual relationships among purchase decision factors of medical devices, satisfaction and repurchasing intention. Data of this study is a 2012 survey on medical institutions using medical devices of MW(ministry of health and welfare) and We analyzed 116 medical institutions having ultrasound imaging system lager than general hospitals among data. For empirical analysis, we carried out confirmative factor analysis and path-analysis using AMOS 21.0 package. Main results of this study are as follows: First, brand has positive influence on satisfaction and satisfaction has positive impaction on repurchase intention. Second, although not statistically significant, performance and service have positive impaction on satisfaction and price has negative influence on satisfaction. The significance of this study is to provide empirical basis on establishment of efficient marketing strategy and enhancement of competitiveness for the medical device industry.

A Study on the Development of Ultrasonic Urine Volume Detection Sensor and the Correlation between Urine Volume and Bladder Interwall Distance (초음파 뇨량검출 센서의 제작 및 방광 벽간거리와 뇨량과의 상관관계에 관한 연구)

  • Choi, H.H.;Lee, E.H.
    • Journal of Sensor Science and Technology
    • /
    • v.9 no.4
    • /
    • pp.256-267
    • /
    • 2000
  • In this paper, we studied the ultrasonic urine volume sensor of urinary alarm system for home use to detect the time of urination as a assistive methodology for the incontinence patients and the correlation between urine volume and bladder interwall distance by using developed sensor. The developed sensor was designed to minimize the measurement error by using ultrasound with 2.25 MHz center frequency which provides higher resolution as well as longer penetration depth. To verify usefulness of the developed sensor, we performed a preliminary experiment of estimating bladder volume from the measured distance between interior and posterior wall of bladder. In the preliminary experiment, bladder volume estimated from the result using a commercial ultrasonography system. The experimental results show there exists god correlation between the actual urine volume and the measured interwall distance of the bladder. In conclusion, the developed ultrasound bladder volume sensor can be applied to an urine alarm system which provides patient the exact time of urination, it will be contribute in health care and welfare society.

  • PDF

The Application of Ultrasonic Spectroscopy System for Phase Transition of Liquid Crystal (액정의 상전이 측정에 대한 초음파 spectroscopy 시스템의 적용)

  • Kim, Jeong-Koo;Lim, Cheong-Hwan
    • Journal of radiological science and technology
    • /
    • v.27 no.4
    • /
    • pp.31-35
    • /
    • 2004
  • A new measuring system for ultrasonic spectroscopy was constructed, utilizing PVDF [poly(vinylidene fluoride)] polymer films as wideband transducers. In a test of its performance, this measuring system was successfully applied to study of the nematic-isotropic phase transition in MBBA(p-methoxybenzylidene-p-n-butylan iline) liquid crystal. We could be confirmed that the phase transition in MBBA is $47^{\circ}C$, which is agree with the exciting optical method. The dependence of frequency on the phase transition was not observed, and but Maximum ultrasonic amplitude is measured for the resonance frequency 2MHz in PVDF transducers, These results shows that the spectroscopy with PVDF transducers takes advantage of studying the transient phenomena. When our apparatus is applied in medical purposes, It will be possible diagnostic for sickle-cell anemia and arterial sclerosis.

  • PDF

Usability Evaluation of Gel Pad Materials for Superficial Structures used in Musculoskeletal Ultrasonography (근골격계 초음파검사에 사용되는 표재성 검사용 젤 패드 물질의 유용성 평가)

  • Han, Mi-Ran;Kwak, Jong-Gil;Song, Jong-Nam;Jang, Seong-Ju;Han, Jae-Bok
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.899-909
    • /
    • 2021
  • In Musculoskeletal ultrasound examination, a linear transducer (12-5 MHz) with a contact surface length of 6 cm, which is commonly distributed in medical institutions, does not contact with bent fingers and wrist depressions only by using a conventional liquid ultrasound gel, which causes image loss. In order to solve this image loss, the use of commercially available Water gel pad is increasing. However, it is a disposable medical product. Repeated use is prohibited and expensive. In this study, in order to reduce the economic burden caused by the use of the commercialized Water gel Pad, we searched for water-soluble food thickener powder that can be easily purchased around our lives and manufactured Gel pads. Among them, kappa-Carrageenan Gel Pad, iota-Carrageenan Gel Pad, and Agar-Agar Gel Pad satisfied the evaluation criteria without artifacts in image evaluation using the N-365 Multipurpose Phantom. Also, the price to purchase the food thickener powder was about 38 times cheaper than the existing commercialized Water gel pad. As a result, if you use the food thickener powder such as kappa-Carrageenan, iota-Carrageenan and Agar-Agar to make solidified elastic Gel pad without a cover instead of the commercially available expensive disposable Water gel pad, the convenience and usefulness of use are improved. It is judged that the manufactured Gel pads can contribute well to the role of efficient ultrasound propagation medium.

Cardiac Rupture Combined with Massive Right Hemothorax by Blunt Chest Trauma -A report of two cases- (흉부둔상환자에서 중증우측혈흉을 동반한 심장파열 -치험 2례-)

  • 정은규;이병욱;윤용한;백완기;김광호;류송현;김혜숙;김정택
    • Journal of Chest Surgery
    • /
    • v.34 no.2
    • /
    • pp.173-175
    • /
    • 2001
  • 흉부둔상에 의한 심장파열은 50% 이상의 치사율을 갖는 질환으로 응급실에 도착하기 전에 사망하는 경우가 대부분이다. 일반적으로 전형적인 심장압전을 동반하기 때문에 이학적 소견이나 심장초음파 또는 흉부전산화 단층촬영으로 진단이 가능하다. 그러나 저자의 경우와 같이 심장압전의 징후가 없이 중증 우측혈흉만 있는 경우 심장파열을 진단하는 것은 어렵다. 만약 고속의 자동차사고로 인한 흉부둔상을 받은 환자에서 늑골골절이 없이 우측에 중증의 혈흉이 있어 응급개흉술을 받아야 한다면 심장파열의 가능성을 염두에두고 수술을 계획하는 것이 필요하다고 생각한다. 본 인하대학교 흉부외과학 교실에서는 흉부둔상에 의한 중증우측 혈흉과 심낭파열을 동반한 심장파열 2례를 심패바이패스와 자가수혈 장치를 이용하여 효과적으로 치료하였기에 보고하는 바이다.

  • PDF

The Recovery of Time Limited Signal by the Extrapolation Matrix and its Application (외삽행렬을 이용한 시간제한신호의 재생과 그 응용)

  • 정종남;최종수
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.21 no.1
    • /
    • pp.25-31
    • /
    • 1984
  • An algorithm on time limited signal extrapolation technique is presented where the total extrapolation process of iteration method is achieved by a single matrix operation. The proposed technique and its implementation has many advantages over iteration method in terms of computational saving and accuracy of the results. As an examples in this paper, appling the proposed technique to ultrasonic diagnosis-device, we prove the excellence of the proposed technique.

  • PDF

Analysis of Propagation Characteristics of Transient Acoustic Fields in biological Media (생체 중 선형 배열 탐촉자의 과도음장 전파 특성 해석)

  • Park Eun-Ju;Ha Kang-Lyeol;Kim Moo-Joon;Kim Dong-Hyeon
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • autumn
    • /
    • pp.205-208
    • /
    • 2001
  • 기존 의료용 초음파 진단장치에 사용되고 있는 선형 배열 탐촉자를 대상으로, 과도음장의 전파특성을 해석하고, 음장 변화에 민감하게 영향을 미치는 구동 펄스의 형태 및 탐촉자의 요소의 크기(element width), 곡률반경(Radius of curvature), 초점길이(focal length) 등 구조적인 변화에 따른 과도음장 전파 특성의 변화 양상을 시뮬레이션을 통해 체계적으로 해석하였다. 나아가, 매질이 간, 근육, 지방 등의 생체 조직인 경우의 음장 변화 특성을 비교 분석하였다.

  • PDF

Pelvic Compression Belt Convergence Impact on the Thickness of Multifidus and Erector Spinae Muscles (골반압박벨트가 뭇갈래근과 척추세움근의 근두께에 융합적으로 미치는 영향)

  • Baek, In-Cheol;Shim, Jae-Hun
    • Journal of the Korea Convergence Society
    • /
    • v.7 no.5
    • /
    • pp.51-57
    • /
    • 2016
  • The purpose of this study was to determine the effectiveness of the pelvic compression belt on the thickness of the erector spinae and multifidus during hip extension on quadruped position. Thirty male university students volunteered to participate in this study. The pelvic compression belt was positioned below the anterior superior iliac spines with the stabilizing pressure using elastic compression bands. Subjects were instructed to perform hip extension in quadruped position with and without applying the pelvic compression belt. The thickness of the erector spinae and multifidus was measured ultrasound during prone position, quadruped position without applying pelvic compression belt and quadruped position applying pelvic compression belt. Data were analyzed using repeated ANOVA. Muscle thickness of multifidus was significantly higher applying the pelvic compression belt than without applying the pelvic compression belt (p<.05). Muscle thickness of elector spinae was significantly higher applying the pelvic compression belt than without applying the pelvic compression belt (p<.05). Therefore, the research can contribute to the prescription and application of quadruped position exercises in clinical practices.