• Title/Summary/Keyword: 초음파 지향성

Search Result 27, Processing Time 0.02 seconds

The Directivity Measurement of Angle Probe by Photoelastic Visualization Method (광탄성가시화법에 의한 사각탐촉자의 지향성 평가에 관한 연구)

  • Nam, Y.H.;Date, K.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.14 no.2
    • /
    • pp.83-89
    • /
    • 1994
  • It is important for an ultrasonic testing to know the sound pressure field and the directivity of ultrasonic waves propagating in a solid. The directivity of ultrasonic wave is closely related to the sensitivity, the scanning pitch, the arrangement of angle probe, and the defect kind in ultrasonic testing. This paper describes on the directivity measurement of ultrasonic wave using ultrasonic wave visualization method. The directivity of the shear wave emitted from the angle probes were constant during propagation. The difference of directivity was existed between 2MHz and 4MHz angle probes. The centers of directivity were located backward from the incident poing and inside of the angle probe and were not changed during the wave propagation.

  • PDF

Directivity Analysis of Ultrasonic Wave Reflected from the Artificial Defect in Simulated Butt Welded Joint (가상 용접부내의 결함으로부터 반사된 초음파의 지향성 해석)

  • Nam, Young-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.15 no.2
    • /
    • pp.378-385
    • /
    • 1995
  • The ultrasonic non-destructive testing uses the directivity of the ultrasonic pulse wave which propagates in one direction. The directivity is expressed as the relationship between the propagate direction and its sound pressure. The directivity of ultrasonic wave is closely related to determination of probe arrangement, testing sensitivity, scanning pitch and defect location and characterization. The paper measured the directivity of shear wave, which reflected from artificial defect located in weld metal zone in butt welded joint similar model made of pyrex glass by using visualization method. 2 MHz and 4 MHz angle probes were used to measure the directivity of reflection wave at the artificial defect. The directivity of shear waves reflected from the defect was different according to the probe position and the shape of butt welded joint. The difference of directivity of reflection wave was existed between 2 MHz and 4 MHz angle probes. The angle of reflection wave became equal to angle of incidence as increase of the height of excess metal.

  • PDF

Directivity Synthesis Simulation of Ultrasonic Transducer Using Gauss Elimination Method (GAUSS 소거법을 이용한 초음파 트랜스듀서의 지향성합성 SIMULATION)

  • 이정남;조기량;이진선;이문수
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.6 no.4
    • /
    • pp.20-27
    • /
    • 1995
  • A numerical simulation is carried out on the directivity synthesis of ultrasonic transducers by point source array. Gauss elimination method is practiced by means of a directive method to realize the desired directivity. Desired directivity is chosen to be that of a directivity of line source, a beam width and a direction arbitrary specified. On the numerical result, Gauss elimination method is showed high speed ca- lculative simulation and stability of system more than iterative method(LMS, DFP). Numerical simulations are carried out by PC(CPU:80486 DX2, RAM 16Mbyte).

  • PDF

Numerical Simulation of Directivity for Probe and Surface Defect (탐촉자와 표면 결함에 대한 지향성의 수치 실험에 관한 연구)

  • Nam, Young-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.15 no.1
    • /
    • pp.291-298
    • /
    • 1995
  • An ultrasonic testing uses the directivity of the ultrasonic wave which propagates in one direction. The directivity is expressed as the relationship between the propagate direction and its sound pressure. This paper studied the directivity of shear waves emitted from angle probes and scattered from surface defects by using visualization method. These experimental results were compared with the theory which was based on the continuous wave. The applicability of continuous wave theory was discussed in terms of the parameter $d/{\lambda}$; where d is transducer or defect size and ${\lambda}$ is the wavelength. In the case of angle probes, the experimental results show good agreement with theoretical directivity on the principal lobe. When defect size was smaller than the wavelengths, clear directivity in the reflected wave was observed. In the case of the same ratio of defect size to wavelength, the directivity of reflected waves from the defect show almost the same directivity in spite of frequency differences. When the $d/{\lambda}$ is greater than 1.5, measured directivities almost agreed with the theoretical one.

  • PDF

Comparison of Gradient Calculation Methods for Directivity Optimization of Adaptive Ultrasonic Transducers (적응형 초음파 트랜스듀서의 지향성 최적화를 위한 구배계산법의 비교)

  • ;Takao Tsuchiya;Yukio Kagawa
    • The Journal of the Acoustical Society of Korea
    • /
    • v.20 no.5
    • /
    • pp.61-68
    • /
    • 2001
  • In this paper, an analytical method and a difference approximation method to calculate the gradient of an objective function have been applied to the directivity optimization in an adaptive ultrasonic transducer which is combined with a point source array and an optimization algorithm (DFP method). To compare these two methods, quasi-ideal .beam with a beam width and direction specified are chosen as the desired directivity. As the numerical results, the difference approximation method shows better suppressive capacity of side lobe level, good stability in the convergence processing, faster convergence speed and excellent adaptability compared with the analytical method.

  • PDF

Evaluation of Near/Far Field and Directivity of Ultrasonic Transducer for Turbine Rotor Disc (터빈 로타 디스크의 초음파탐상을 위한 초음파탐촉자의 지향성 및 탐상범위)

  • Won, S.H.;Chang, H.K.;Cho, K.S.;Lee, J.O.;Lee, J.K.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.18 no.3
    • /
    • pp.163-171
    • /
    • 1998
  • Near/far field length and directivity of transducers were investigated for the improvement and evaluation of the detectability of flaws in a disc. The reference block is fabricated for the disc of stage 6 in Yonggwang unit 1. The near/far field and directivity of an ultrasonic transducer with the center frequency of 5MHz were calculated for the inspection of the disc. These values showed good agreements with the experimental results. In the system composed of a wedge and a disc, those are evaluated theoretically and experimentally for the specimen with the artificial flaws of the size 2mm and 4mm and an ultrasonic transducer with the center frequency 5MHz and diameter 0.5inch. The detectability of keyway-flaw and detectable region for inspection were evaluated by using both tangential $45^{\circ}$ and $90^{\circ}$ transducers located at the distance of 53mm and 75mm from the disc hub, respectively.

  • PDF

Atomization Technology of Liquid Fuels (액체연료의 미립화 기술(2))

  • 류정인
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.15 no.5
    • /
    • pp.31-41
    • /
    • 1993
  • 7. 음파의 흡수와 분산. 8. 초음파의 지향성. 9. 고유진동과 공명,공진. 9.1 고유진동. 9.2 공진,공명. 9.3 공진주파수. 10. 캐비테이션. 10.1 현상. 10.2 거동. 11. 초음파. 11.1 초음파의 발생기구.

  • PDF

Improvement of sound transfer effect of Parametric Array Speaker using HRTF preprocessing (HRTF를 이용한 파라메트릭 어레이 스피커 전달감 개선에 관한 연구)

  • Seo, Bo-Kug;Seo, Joung-Kook;Cha, Hyung-Tai
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2019.05a
    • /
    • pp.577-578
    • /
    • 2019
  • 지향성 스피커는 초음파를 이용하여 소리에 직진성을 부여하여 특정 방향으로만 소리를 전달할 수 있다. 이러한 지향성 스피커는 초음파의 직진성 때문에 소리를 청취함에 있어 일반 스피커와 달리 전달감이 풍부하지 못하다는 단점이 있다. 본 논문에서는 청취자에게 음원이 전달되는 과정을 모델링한 머리전달함수를 사용한다. 지향성 스피커를 통하여 방사되는 음원에 머리전달함수를 전처리하여 전달감을 개선한다.

Fabrication of an Ultrasonic Speaker with Piezoelectric Ceramics (압전 세라믹을 이용한 초음파 스피커의 제작)

  • 문창호;안도현;노용래
    • The Journal of the Acoustical Society of Korea
    • /
    • v.18 no.2
    • /
    • pp.18-24
    • /
    • 1999
  • In this paper, we have investigated on the development of ultrasonic speakers that have higher directivity and much wider bandwidth than those of conventional loudspeakers. For optimal structure of speaker, we have analyzed material properties and dimension of the piezoelectric element and the vibrating metal plate, and their support type as well as the housing case. Based on the design, we have fabricated ultrasonic speaker prototypes, measured their performance, and verified validity of the design theory. For higher sound pressure level, the ultrasonic array speaker prototype has been fabricated in the form of an array. The design and fabrication method worked in this paper can be utilized in development of various ultrasonic speakers with higher directivity and broader bandwidth.

  • PDF

Optimal Directivity Synthesis of Ultrasonic Transducers Using a Combined Algorithm (조합 알고리즘에 의한 초음파 트랜스듀서의 최적 지향성합성)

  • ;Takao Tsuchiya;Yukio Kagawa
    • The Journal of the Acoustical Society of Korea
    • /
    • v.19 no.1
    • /
    • pp.25-31
    • /
    • 2000
  • In this paper, we proposed an algorithm that used a direct method to set an initial value of Broydon-Fletcher-Goldfarb-Shanno(BFGS) method and, accordingly, conducted an experiment in optimal directivity synthesis of adaptive ultrasonic transducer by point source array. To certify the efficiency of this method, quasi-ideal beam with arbitrary beam width, rotating beam, and multi beam, all with the limited side lobe level -30dB, were chosen to check the problem of directivity synthesis that was formed by point source array in the second dimensional sound field. The numerical calculation results showed that the proposed method performed the directivity synthesis faster than the BFGS method did. In addition, the proposed method showed a good error correction for directivity synthesis, and did not demand the choice of initial value. Finally, it is also shown that the proposed method can be used for the adaptive control that was not possible with the direct method alone.

  • PDF