• Title/Summary/Keyword: 초음파 발생원

Search Result 166, Processing Time 0.032 seconds

A Design of Acoustic Vector channel Simulator. long-won (다 채널 수중 초음파 전달 시뮬레이터 설계)

  • 박종원;임용곤;최영철
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2000.10a
    • /
    • pp.468-472
    • /
    • 2000
  • This paper discusses the development of a acoustic vector channel simulator for the performance analysis of a acoustic digital communication system. The channel simulator consists of transmission module, acoustic channel model, receiver, beamformer, and adaptive equalizer. QPSK source signal is generated by the parameters specified by a user and transmitted. The transmitted signal generate multipath signals which have a different delay, amplitude, and dopper Sequency. The multipath signals with the acoustic noises is the received signal. We can analysis the communication system performance according to the antenna structure, beamforming algorithm, and equalization algorithm.

  • PDF

Analysis of Correlation for Uterine Myoma and Stress by Ultrasonography (초음파 검사에 의한 자궁근종과 스트레스의 상관성 분석)

  • Choi, Ji-Hyun;Kim, Jeong-Koo
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.1
    • /
    • pp.277-283
    • /
    • 2011
  • We investigated correlation between myoma and stress using korean version of BEPSI survey in 374 women more than 19 years age. Diagnosis method made use of ultrasonography for a case-control group because it is low cost, convenient and safety. Prevalence of myoma was 29.7% and according to resulting of cross-tabulations analysis for the correlation between myoma and stress using BEPSI-K survey, the high group of stress showed a high prevalence of myoma and statistical significance (p<0.05). Statistical significance for correlation between myoma and stress will be a help to prevention of myoma.

An Acoustic Vector channel Simulator Design (다 채널 수중 초음파 전달 시뮬레이터 설계)

  • 박종원;임용곤;최영철
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.4 no.4
    • /
    • pp.861-868
    • /
    • 2000
  • This paper discusses the development of an acoustic vector channel simulator for the performance analysis of an acoustic digital communication system. The channel simulator consists of transmission module, acoustic channel model, receiver, beamformer, and adaptive equalizer. QPSK source signal is generated by the parameters specified by a user. The transmitted signal generates multipath signals which have a different delay, amplitude, and dopper frequency. The multipath singnals with the acoustic noises are the received signal. This paper presents the performance analysis of an acoustic digital communication system according to the antenna structure and the various baseband signal processing techniques.

  • PDF

Carotid Artery Disease in Duplex Sonography: 3 Cases (이중초음파에서 관찰된 목동맥 질환: 3례)

  • Han, Minho;Choi, Junghye;Seo, Gang Sik;Nam, Hyo Suk
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.51 no.1
    • /
    • pp.114-118
    • /
    • 2019
  • Duplex sonography has been used to non-invasively diagnose carotid artery disease and to follow up patients with this disease. In carotid artery disease, carotid mobile thrombus and dissection are rarely detected by duplex sonography in patients with cerebrovascular events. In particular, carotid dissection occurs when a small tear forms in the tunica intima and makes 2 lumens in the carotid artery, including true and false lumens. This study reports 3 rare cases of carotid mobile thrombus, spontaneous carotid dissection, and carotid dissection in Takayasu arteritis.

Cell-cultivable ultrasonic transducer integrated on glass-coverslip (세포 배양 가능한 커버슬립형 초음파 변환자)

  • Keunhyung Lee;Jinhyoung Park
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.5
    • /
    • pp.412-421
    • /
    • 2023
  • Ultrasound brain stimulation is spot-lighted by its capability of inducing brain cell activation in a localized deep brain region and ultimately treating impaired brain function while the efficiency and directivity of neural modulation are highly dependent on types of stimulus waveforms. Therefore, to optimize the types of stimulation parameters, we propose a cell-cultivable ultrasonic transducer having a series stack of a spin-coated polymer piezoelectric element (Poly-vinylidene fluoride-trifluorethylene, PVDF-TrFE) and a parylene insulating layer enhancing output acoustic pressure on a glass-coverslip which is commonly used in culturing cells. Due to the uniformity and high accuracy of stimulus waveform, tens of neuronal cell responses located on the transducer surface can be recorded simultaneously with fluorescence microscopy. By averaging the cell response traces from tens of cells, small changes to the low intensity ultrasound stimulations can be identified. In addition, the reduction of stimulus distortions made by standing wave generated from reflections between the transducers and other strong reflectors can be achieved by placing acoustic absorbers. Through the proposed ultrasound transducer, we could successfully observe the calcium responses induced by low-intensity ultrasound stimulation of 6 MHz, 0.2 MPa in astrocytes cultured on the transducer surface.

Study on Characteristics of Solubilization for Sewage Sludge Using Electronic Field and Ultrasonification (전기장과 초음파를 이용한 하수슬러지의 가용화 특성 연구)

  • Seo, Jang-Won;Han, Ji-Sun;Ahn, Chang-Min;Min, Dong-Hee;Yoo, Yeon-Sun;Yoon, Soon-Uk;Lee, Jong-Gyu;Lee, Jong-Yeon;Kim, Chang-Gyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.9
    • /
    • pp.636-643
    • /
    • 2011
  • Sludge solubilization using sonification has been increasingly used for sludge volume reduction along with enhancing digestion efficiency during anaerobic biogas production. In this study, either electric field or ultrasonification or in combination with were investigated using three types of sludge (return, excess and mixed at G sewage treatment facility) for the most efficient solubilization. As a the closed loop, 200 L of sludge was continuously passing through the solubilization system at an average flow rate of $0.7m^3/h$, which is equivalent to 3.5 times treated per hour for up to 84 times (24 h). Only implying electric field showed no variation for sCOD/tCOD before and after treatment on sludge solubilization regardless of types of sludge. However, employing the ultrasonic or combined system could both increasingly solubilize sludge with regard to the number of passing-through, which more enhanced by the combined. In addition, VSS/TSS was lowered to in the range of 2 and 6% while its particle size, diameter (0.9) and diameter (0.5) were more minimized than that of raw sludge. For return sludge, ultrasonification was more efficiently facilitated for solubilization, whereas electric field-ultrasonification was more preferably applied for excess and mixed sludge. It is concluded that depending on types of sludge, solubilization system must be selectively applied for the most efficient break-up of them.

High Resolution Borehole Acoustic Scanner (Televiewer) (고분해능 텔레뷰어 검층기법의 기능)

  • ;Schepers,R
    • The Journal of Engineering Geology
    • /
    • v.5 no.3
    • /
    • pp.277-288
    • /
    • 1995
  • Fracture detection has always been very attractive to the log, because it is important in many of our prospecting activities, e.g. in understanding the underground rock formation and also the fluid flow as a high permeability path. This paper demonstrates the use of high resolution borehole acoustic scanner for the detection of fractures. The tool, known as Televiewer, is the first acoustic borehole imaging system to use a focussed beam. The acoustic beams generated by a single transducer are sent toward the borehole wall, scanning the wall in a tight helix as the tool moves along the borehole. The amplitudes and travel times of the reflected signals are then measured, which produces the corresponding images. The highly resolved amplitude image allows to recognize various size of fractures and in addition to derive the rock strength from the image. Meanwhile, the travel time image itself can be directly converted to a precise caliper image, providing detailed information of deviations of the borehole shape. It also allows correction of and explanations for amplitude variations. Field measurements were carried Out at the Cheongyang study sites in Korea to illustrate the efficiency of the televiewer log.

  • PDF

Design and manufacture of supersonic waves system that there is no invasion that there is no stimulation of embedded base for crush bone fracture patient's treatment (II) (파쇄 골절환자의 치료를 위한 임베디드 기반의 무자극, 무침습 초음파 시스템의 설계 및 제작(II))

  • Kim, Whi-Young
    • Journal of the Korea Computer Industry Society
    • /
    • v.7 no.5
    • /
    • pp.583-590
    • /
    • 2006
  • BT technology, medical treatment engineering technology is offering important role and grow by creative technology. Specially, bone fracture treatment can achieve very important role in research of bone, physiology and dynamics of bone is very useful patient's diagnostic and treatment in presence at a sickbed. <중략>Furthermore embedded base of in administration aspect as well as if supersonic waves curer is treatment innocuously and without invasion very efficient tell. If apply supersonic waves in bone fracture treatment, can reduce curer about 40%. Operation frequency through bone fracture treatment supersonic waves curer of embedded base designs and manufactured 1m Hz, 1.2mHz, 1.3mHz, 1.4mHz, supersonic waves origination that have 1.5mHz's tranducer, and embodied protocol in PDA base in this research, and did so that is interfaced to general PC. If is using but supplement research water that see clinically by diagnosis in city, is seen to become convenient medical treatment assistance mounting to bone fracture patient's treatment and courtesy call. Specially, tried to approach basic form after modeling processing if may be applied variously to physiotherapy, orthopaedics patient who gouge late, and study standardization special quality little more.

  • PDF

Development of a cylindrical ultrasound applicator for Intracavitary Hyperthermia (강내온열 치료를 위한 원통형 초음파 치료기 개발)

  • Lee, Rena J.;Hyunsuk Suh
    • Progress in Medical Physics
    • /
    • v.13 no.2
    • /
    • pp.79-84
    • /
    • 2002
  • In this study, a cylindrical ultrasound applicator is developed for the treatment of vagina and rectum in combination with high dose rate brachytherapy. A cylindrical transducer (PZT-8, 1=1.5 cm, thickness=1.5mm OD=2.5 cm) was used as an energy source for induction of hyperthermia. Three single-element applicators were constructed to examine the performance of the PZT material. Vector impedance was measured to determine driving frequency. The efficiencies of the elements were determined using a radiation force technique to evaluate the feasibility of using the applicator as a hyperthermia source. A multi-element ultrasound applicator was designed using the PZT-8 material for the treatment of vagina. Results from the vector impedance measurements showed maximum magnitude at 1.78, 1.77, and 1.77 MHz for applicator 1,2, and 3, respectively. The radiation force measurements showed that the acoustic power of 40 watts was obtained in all three elements. The average efficiencies of the elements were 61.4, 65.2, and 54.0% for element 1, 2, and 3, respectively. The designed ultrasound hyperthermia applicator could be used in combination with high dose rate brachytherapy for the treatment of vagina and rectum. The use of this applicator with intracavitary brachytherapy could offer improved tumor control by increasing radiosensitiyity of the tumor.

  • PDF

Ultrasound-guided Exact Focusing of Extracorporeal Shock Wave Therapy for the Calcific Tendinitis of Gluteus Medius - A Case Report - (중둔건 석회화 건염의 초음파 유도하 정확한 조준에 의한 체외충격파치료 -증례 보고-)

  • Moon, Sang Ho;Lee, Song;Kim, Kwang Hai;Jeong, Jongpil;Hong, Seong Won
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.5 no.2
    • /
    • pp.94-98
    • /
    • 2012
  • Calcific tendinitis is characterized by inflammation around calcium hydroxyapatite crystal deposits. Minimally invasive extracorporeal shock wave therapy (ESWT) has been postulated to be an effective treatment option for treating calcific tendinitis. In clinical practice, shock waves usually are aimed at the painful area after palpation and not focused. It has been known that exact fluoroscopic focusing of ESWT at the calcific deposit for treatment of calcifying tendinopathy is highly effective. Ultrasound is a simple, inexpensive and radiation-free diagnostic tool that has been used to demonstrate tendinopathy including calcific tendinitis. However, focusing of shock wave under ultrasound is less well established. We present a patient in whom large calcific tendinitis of gluteus medius was completely resolved by exact focusing of ESWT by ultrasound with literature review.

  • PDF